Messages Reference Guide

92 Storage Management Message Reference
2057 Virtual disk
degraded
Warning /
Non-
critical
Cause 1: This alert message
occurs when a physical disk
included in a redundant
virtual disk fails. Because
the virtual disk is redundant
(uses mirrored or parity
information) and only one
physical disk has failed, the
virtual disk can be rebuilt.
Action 1: Configure a hot
spare for the virtual disk if
one is not already
configured. Rebuild the
virtual disk. When using an
Expandable RAID
Controller (PERC) PERC
3/SC, 3/DCL, 3/DC, 3/QC,
4/SC, 4/DC, 4e/DC, 4/Di,
CERC ATA100/4ch, PERC
5/E, PERC 5/i or a Serial
Attache SCSI (SAS) 5/iR
Clear Alert
Number:
None.
Related Alert
Number: 2048,
2049, 2050,
2076, 2079,
2081, 2123,
2129, 2346
LRA Number:
2080
1203
Cause 2: A physical disk in
the disk group has been
removed.
Action 2: If a physical disk
was removed from the disk
group, either replace the
disk or restore the original
disk. You can identify
which disk has been
removed by locating the
disk that has a red “X” for
its status. Perform a rescan
after replacing the disk.
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP