Messages Reference Guide

96 Storage Management Message Reference
2070 Virtual disk
initialization
cancelled
OK/
Normal
Cause: The virtual disk
initialization cancelled
because a physical disk
included in the virtual disk
has failed or because a user
cancelled the virtual disk
initialization.
Action: If a physical disk
failed, then replace the
physical disk. You can
identify which disk has
failed by locating the disk
that has a red “X” for its
status. Perform a rescan
after replacing the disk.
Restart the format physical
disk operation. Restart the
virtual disk initialization.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1201
2074 Physical disk
rebuild
cancelled
OK/
Normal
Cause: A user has cancelled
the rebuild operation.
Action: Restart the rebuild
operation.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
901
2075 Copy of data
completed
on physical
disk %2 from
physical disk
%1
OK/
Normal/
Informa-
tional
Cause: This alert is
provided for informational
purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number: 2060.
LRA Number:
None
1201
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers