Messages Reference Guide

98 Storage Management Message Reference
2079 Virtual disk
initialization
failed
Critical /
Failure /
Error
Cause: A physical disk
included in the virtual disk
has failed or a user has
cancelled the initialization.
Action: If a physical disk
has failed, then replace the
physical disk.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2081
1204
2080 Physical disk
initialize
failed
Critical /
Failure /
Error
Cause: The physical disk
has failed or is corrupt.
Action: Replace the failed
or corrupt disk. You can
identify a disk that has
failed by locating the disk
that has a red “X” for its
status. Restart the
initialization.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2071
904
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers