Messages Reference Guide

Storage Management Message Reference 99
2081 Virtual disk
reconfigurati
on failed
Critical /
Failure /
Error
Cause: A physical disk
included in the virtual disk
has failed or is corrupt. A
user may also have
cancelled
the reconfiguration.
Action: Replace the failed
or corrupt disk. You can
identify a disk that has
failed by locating the disk
that has a red “X” for its
status.
If the physical disk is part
of a redundant array, then
rebuild the physical disk.
When finished, restart
the reconfiguration.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2081
1204
2082 Virtual disk
rebuild
failed
Critical /
Failure /
Error
Cause: A physical disk
included in the virtual disk
has failed or is corrupt. A
user may also have
cancelled the rebuild.
Action: Replace the failed
or corrupt disk. You can
identify a disk that has
failed by locating the disk
that has a red “X” for its
status. Restart the virtual
disk rebuild.
Clear Alert
Number:
None.
Related Alert
Number: 2048
LRA Number:
2081
1204
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap