User's Manual

104 omconfig: Managing Components Using the Instrumentation Service
Components and Events for Which You Can Set Alert Actions
Table 4-21 lists the components and the events for which you can set alert
actions. Components are listed in alphabetical order, except that warning events
always precede failure events for a component.
execappath=<string> Sets the fully qualified path and file name of the application you
want to execute in case of an event for the component described
in this window.
NOTE: On Linux systems, user/user groups upgraded to
administrator/administrator groups cannot configure this alert
action setting.
execapp=false Disables the executable application.
Table 4-21. Events for Which You Can Set Alert Actions
Event Name Description
event=batterywarn Sets actions when a battery probe detects a warning value.
event=batteryfail Sets actions when a battery probe detects a failure value.
event=fanwarn Sets actions when a fan probe detects a warning value.
event=fanfail Sets actions when a fan probe detects a failure value.
event=hardwarelogwarn Sets actions when a hardware log detects a warning value.
event=hardwarelogfull Sets actions when a hardware log is full.
event=intrusion Sets actions when a chassis intrusion event is detected.
event=memprefail Sets actions when a memory probe detects a prefailure value.
event=memfail Sets actions when a memory probe detects a failure value.
event=systempowerwarn Sets actions when a power consumption probe detects a warning
value.
event=systempowerfail Sets actions when a power consumption probe detects a failure
value.
event=powersupply Sets actions when a power supply probe detects a failure value.
event=powersupplywarn Sets actions when a power supply probe detects a warning value.
event=processorwarn Sets actions when a processor probe detects a warning value.
event=processorfail Sets actions when a processor probe detects a failure value.
event=redundegrad Sets actions when a redundant component becomes inoperative,
resulting in less than full redundancy for that component.
event=redunlost Sets actions when one or more redundant components become
inoperative, resulting in a lost or a "no redundant components
working" condition for that component.
event=tempwarn Sets actions when a temperature probe detects a warning value.
Table 4-20. Alert Actions You Can Set for Warning and Failure Events
(continued)
Alert Action Setting Description