omconfig: Managing Components Using the Instrumentation Service 115
Table 4-30 shows the valid parameters for the command.
Example Thermal Shutdown Commands
To trigger a thermal shutdown when a temperature probe detects a failure
event, type:
omconfig system thrmshutdown severity=failure
or
omconfig servermodule thrmshutdown severity=
failure
To disable thermal shutdown so that an administrator has to initiate an
omconfig system shutdown, type:
omconfig system thrmshutdown severity=disabled
or
omconfig servermodule thrmshutdown severity=
disabled
Table 4-30. Thermal Shutdown Parameters
name=value
pair
Description
severity=
disabled |
warning |
failure
disabled: Disable thermal shutdown. An administrator must intervene.
warning: Perform a shutdown when a temperature warning event is detected.
A warning event occurs when any temperature probe inside a chassis reads a
temperature (in degrees Celsius) that exceeds the maximum temperature
warning threshold value.
failure: Perform a shutdown when a temperature failure event is detected.
A failure event occurs when any temperature probe inside a chassis reads a
temperature (in degrees Celsius) that exceeds the maximum temperature
failure threshold value.