User's Manual

Using the Storage Management Service 147
omconfig Rescan Controller
Use the following omconfig command syntax to rescan a controller. See
Dell OpenManage Online Help for more information about Rescan
Controller.
Complete Syntax
omconfig storage controller action=rescan
controller=id
where id is the controller ID as reported by the omreport storage controller
command.
Example Syntax
To rescan controller 1, enter:
omconfig storage controller action=rescan
controller=1
NOTE: The rescan controller is not supported on non–RAID SCSI and SAS
controllers. Reboot the system for the configuration changes on non-RAID SCSI
controllers to be visible.
omconfig Enable Controller Alarm
Use the following omconfig command syntax to enable the controller alarm.
See the Dell OpenManage Online Help for more information about Enable
Controller Alarm.
action=setchangecontrollerproperties controller=<id>
abortcheckconsistencyonerror=<enabled/disabled>
allowreplacemember=<enabled/disabled> loadbalance=
<auto/disabled> autoreplacememberonpredictivefailure=
<enabled/disabled> bgirate=<rate> reconstructrate=<rate>
rebuildrate=<rate> checkconsistencyrate=<rate>
clearredundantpath=disabled
action=discardpinnedcache controller=id force=e|d
omconfig storage
vdisk
action=replacememberdisk controller=id vdisk=id source=<PDISKID>
destination=<PDISKID>
Table 6-16. omconfig Controller Commands
(continued)
Required Command
Levels (1, 2, 3)
Optional name=value pairs