User's Manual

Using the Storage Management Service 195
Example for SCSI, SATA, and ATA Controllers
To specify the asset name to encl43 for the enclosure attached to connector 2
on controller 1, enter:
omconfig storage enclosure action=setassetname
controller=1 enclosure=2 assetname=encl43
Example for SAS Controllers
To specify the asset name to encl43 for enclosure 2 attached to connector 1
on controller 1, enter:
omconfig storage enclosure action=setassetname
controller=1 enclosure=1:2 assetname=encl43
omconfig Set Temperature Probe Thresholds
Use the following omconfig command syntax to set the minimum and
maximum warning temperature thresholds for a specified temperature probe.
NOTE: This command is not supported on SAS controllers.
Complete Syntax
omconfig storage enclosure action=settempprobes
controller=id enclosure=<ENCLOSUREID> index=id
minwarn=n maxwarn=n
where id is the controller ID and the temperature probe ID. The
<ENCLOSUREID> variable specifies the enclosure.
In this syntax, “n” is a user-specified value for the temperature in Celsius.
Example Syntax
For example, you may want to specify the minimum and maximum warning
thresholds for temperature probe 3 to 10 and 40° Celsius.