User's Manual

80 omconfig: Managing Components Using the Instrumentation Service
Valid Parameters for Fan Warning Thresholds
Table 4-4 shows the valid parameters for setting fan warning thresholds:
Default Minimum and Maximum Warning Thresholds
NOTE: Systems that contain ESM3, ESM4, and BMC capabilities do not allow you to
set warning threshold values to default values.
If you want to set both the upper and lower fan warning threshold values to
the recommended default value, type:
omconfig chassis fans index=0 warnthresh=default
or
omconfig mainsystem fans index=0 warnthresh=
default
You cannot default one value and set another. In other words, if you default
the minimum warning threshold value, you are also selecting the default
value for the maximum warning threshold value.
Specifying a Value for Minimum and Maximum Warning Thresholds
If you prefer to specify values for the fan probe warning thresholds, you must
specify the number of the probe you are configuring and the minimum and/or
maximum warning threshold values. In the following example, the probe that
is being configured is probe 0. The first command sets only the minimum
threshold; the second sets minimum and maximum thresholds:
omconfig chassis fans index=0 minwarnthresh=4580
or
omconfig mainsystem fans index=0 minwarnthresh=
4580
Table 4-4. omconfig chassis fans/omconfig chassis fans
name=value pair Description
index=<n> Number of the probe or probe index (must be specified).
warnthresh=default Sets minimum and maximum warning thresholds to default.
minwarnthresh=<n> Minimum warning threshold.
maxwarnthresh=<n> Maximum warning threshold.