User's Manual

omconfig: Managing Components Using the Instrumentation Service 81
omconfig chassis fans index=0 minwarnthresh=4580
maxwarnthresh=9160
or
omconfig mainsystem fans index=0 minwarnthresh=
4580 maxwarnthresh=9160
When you issue the command and the system sets the values you specify, the
following message appears:
Fan probe warning threshold(s) set successfully.
NOTE: Minimum and maximum warning thresholds for the fan probe cannot be set
on PowerEdge
x
8xx and x9xx systems.
omconfig chassis fancontrol/omconfig mainsystem fancontrol
Use the omconfig chassis fancontrol or omconfig mainsystem fancontrol
command to set the fan speed. You can optimize speed for cooling or for
quiet operation. Table 4-5 shows the valid parameters for the command.
omconfig chassis frontpanel/omconfig mainsystem frontpanel
Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel
command to configure the Power button and the Nonmasking Interrupt
(NMI) button and to specify and configure the LCD line number.
NOTE: The Power and NMI buttons can be configured only if present on the
system.
Table 4-6 shows the valid parameters for the command.
Table 4-5. omconfig chassis fancontrol/omconfig mainsystem fancontrol
name=value pair Description
speed=quiet Sets fan speed for quiet operation.
speed=maxcool Sets fan speed for maximum cooling.
Table 4-6. omconfig chassis frontpanel/omconfig mainsystem frontpanel
name=value pair 1 name=value pair 2 Description
lcdindex=<index> NA Specifies the LCD line number.
config=none |
default | custom
NA none: Sets the LCD text to none.
default: Sets the LCD text to default.
custom: Sets the LCD text to custom.