User's Manual

82 omconfig: Managing Components Using the Instrumentation Service
omconfig chassis info/omconfig mainsystem info
Use the omconfig chassis info or omconfig mainsystem info command to
enter an asset tag name for your system and a chassis name for your system.
If your system is a modular one, you can enter asset tag names for modular
components as well. Table 4-7 shows the valid parameters for the command.
In the following example, the asset tag for the main system chassis is being set
to buildsys:
omconfig chassis info index=0 tag=buildsys
or
omconfig mainsystem info index=0 tag=buildsys
Index 0 always defaults to the main system chassis. The following command
omits index=n, but accomplishes the same thing:
omconfig chassis info tag=buildsys
or
omconfig mainsystem info tag=buildsys
An acceptable command, when executed, results in the following message:
Chassis info set successfully.
text=<custom text> NA Sets the custom text for LCD when config=
custom.
nmibutton enable=true | false true: Enables the NMI button on the system.
false: Disables the NMI button on the system.
powerbutton enable=true | false true: Enables the Power button on the system.
false: Disables the Power button on the system.
Table 4-7. omconfig chassis info/omconfig mainsystem info
name=value pair Description
index=<n> Number of the chassis whose asset tag or name you are setting.
tag=<text> Asset tag in the form of alphanumeric text. Letters or numbers
cannot exceed 10 characters.
name=<text> Name of the chassis.
Table 4-6. omconfig chassis frontpanel/omconfig mainsystem frontpanel
(continued)
name=value pair 1 name=value pair 2 Description