Users Guide

126 Working with BMC/iDRAC
NOTE: System Power Probe Warning and System Power Probe Failure are
not supported on Dell systems without PMBus support though OMSA allows
you to configure.
NOTE: On Dell PowerEdge 1900 systems, the PS/VRM/D2D Warning,
PS/VRM/D2D Failure, and Power Supply Absent Platform Event Filters are not
supported even though Server Administrator allows you to configure these
Event Filters.
4
Choose the platform event for which you want to take shutdown actions or
generate alerts for selected actions and click
Set Platform Events
.
The
Set Platform Events
window allows you to specify the actions to be
taken if the system is to be shut down in response to a platform event.
5
Select one of the following actions:
None
Takes no action when the operating system is hung or has crashed.
Reboot System
Shuts down the operating system and initiates system startup,
performing BIOS checks and reloading the operating system.
Power Cycle System
Turns the electrical power to the system off, pauses, turns the power
on, and reboots the system. Power cycling is useful when you want to
reinitialize system components such as hard drives.
Power Off System
Turns off the electrical power to the system.
Power Reduction
Degrades the performance of the system.
NOTICE: If you select a Platform Event shutdown action other than None or
Power Reduction, your system will shut down forcefully when the specified
event occurs. This shutdown is initiated by firmware and is done without first
shutting down the operating system or any running applications.
6
Select the
Generate Alert
check box for the alerts to be sent.
NOTE: To generate an alert, you must select both Generate Alert and the
Enable Platform Events Alerts settings.
7
Click
Apply Changes
.
8
Click
Go Back to Platform Events Page
to go back to the
Platform Event
Filters
window.
book.book Page 126 Monday, July 7, 2008 2:59 PM