Using the Storage Management Service 179
omconfig Global Enable Smart Thermal Shutdown
By default, the operating system and server shut down when the PV220S and
PV221S enclosures reach a critical temperature of 0 or 50° Celsius. However,
if you have implemented
connector redundancy on the PV220S and PV221S
enclosures you can specify that only the enclosure and not the operating
system and server be shut down when the enclosure reaches a critical
temperature of 0 or 50° Celsius. Specifying that only the enclosure be shut
down during excessive temperatures is known as Smart Thermal Shutdown.
See the Dell OpenManage Online Help for more information about Smart
Thermal Shutdown.
Use the following omconfig command syntax to enable smart thermal
shutdown.
Complete Syntax
omconfig storage globalinfo action=enablests
Example Syntax
The omconfig command syntax for enabling thermal shutdown does not
require that you specify a controller or enclosure ID. To enable thermal
shutdown, enter the following:
omconfig storage globalinfo action=enablests
NOTE: You can use the omreport storage globalinfo command to determine
whether smart thermal shutdown is currently enabled or disabled. The status of
smart thermal shutdown is also displayed by the Server Administrator graphical
user interface (GUI). To locate this status, select the Storage object and the
Information/Configuration tab.
omconfig Global Disable Smart Thermal Shutdown
If you have previously enabled smart thermal shutdown using the omconfig
command, you can disable smart thermal shutdown and return the system to
its default setting. When smart thermal shutdown is disabled, the operating
system and the server shuts down when the PV220S and PV221S enclosures
reach a critical temperature of 0 or 50
° Celsius.
Use the following omconfig command syntax to disable smart thermal
shutdown for all controllers.