Dell™ OpenManage™ Server Administrator Version 6.
Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. ____________________ Information in this document is subject to change without notice. © 2003–2009 Dell Inc. All rights reserved. Reproduction of these whatsoever without the written permission of Dell Inc. is strictly forbidden.
Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 19 Audience . . . . . . . . . . . . . . . . . . . . . . 19 What’s New in this Release . . . . . . . . . . . . . . . Supported SNMP Versions . . . . . . . . . . . . What's New in System State Group 19 . . . . . . . . . . . 20 . . . . . . . . . . . . . . . . 21 What's New in Power Group . . . . . . . . . . . Introduction to the SNMP Reference Guide General Content 19 . . . . . . . .
Other Documents You May Need . . . . . . . . . Introduction to the Server Administrator SNMP Subagent . . . . . . . . . . . . . . . . . . . . . 38 . . . . . . . . . . . . . . . . . . 40 . . . . . . . . . . . . . . . . . . . 41 SNMP MIB OIDs SNMP Security . . . . . . . . . . . . . . . 42 . . . . . . . . . . . . . . . . . . . . 42 Management Actions SNMP Traps 2 Instrumentation MIB Version Group . . . . 43 MIB Major Version Number . . . . . . . . . . . . . . .
Systems Management Software Language Name . . . . . . . . . . . . . . . . . . 48 Systems Management Software Global Version Name . . . . . . . . . . . . . . . . 48 Systems Management Software Feature Flags . . . . . . . . . . . . . . . . . . . . 48 Systems Management Software SNMP Agent Feature Flags . . . . . . . . . . . . 49 Systems Management Software Manufacturer Name . . . . . . . . . . . . . . . . 49 Systems Management Software Variable Values 4 . . . 49 System State Group . . . .
Operating System Memory Table . 7 System Resource Group . . . . . . . . . . . . . . . . . . . . . System Resource Group Tables . . . . . . . . . . . . . System Resource Map Table . . . . . . . . . . . . System Resource Owner Table . . . . . . . . . . . System Resource Input/Output (I/O) Port Table . . . . . . . . . . . . . . 129 . . . . . . . . . . 135 System Resource Interrupt Table . . . . . . . . . 138 System Resource Direct Memory Access (DMA) Table . . . . . . . . . . . . . . . .
Cooling Device Table . User Security Table 215 . . . . . . . . . . . . . . . . 215 Remote Flash BIOS Group Table Remote Flash BIOS Table . . . . . . . . . . 219 . . . . . . . . . . . . . 219 225 225 . . . . . . . . . . . . . . . . . . . . Pointing Port Table 231 . . . . . . . . . . . . . . . Memory Device Port Table . . . . . . . . . . . . . 234 . . . . . . . . . . . . . . . . . 237 Small Computer System Interface (SCSI) Port Table . . . . . . . . . . . . . . . . . . . . . . 240 . . .
Pointing Device Table . . . . . . . . . . . . . . . 260 Keyboard Device Table . . . . . . . . . . . . . . . 262 . . . . . . . . . . . . . . 265 Processor Device Table Processor Device Status Table Cache Device Table . . . . . . . . . . 273 . . . . . . . . . . . . . . . . 275 . . . . . . . . . . . . . . . 281 Memory Device Table Memory Device Mapped Address Table . . . . . . 289 . . . . . . . . . . . . . . . 292 . . . . . . . . . . . . . . . . . . 295 Generic Device Table .
16 BIOS Setup Control Group BIOS Group Tables . . . . . . . . . . 383 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383 . . . . . . . . . . . . . . . . . 394 BIOS Setup Control Table SCSI Control Table Parallel Port Control Table . . . . . . . . . . . . . 396 . . . . . . . . . . . . . . 398 . . . . . . . . . . . . . . . . . 400 . . . . . . . . . . . . . . . . . . 402 Serial Port Control Table USB Control Table IDE Control Table Diskette Control Table 404 . . . . . . . .
COO Support Information Table COO Trouble Ticket Table . . . . . . . . . . . 454 . . . . . . . . . . . . . 456 Cost of Ownership Variable Values 19 Remote Access Group . DRAC 4 and DRAC 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 461 . . . . . . . . . . . . . . . . . . . . . . . . . 467 . . . . . . . . . . . . . . . Remote User Administration Table Remote Dial-Up Table . . . . . . . . . 477 485 . . . . . . . . . . . . . . .
Baseboard Management Controller Group Variable Values . . . . . . . 22 Field Replaceable Unit Group Field Replaceable Unit Group Tables . . . . . . . . . . . . . . . . . . 537 537 . . . . . . . . . . . . . . . 541 23 Storage Management Group . Storage Management Group . . . . . . . . 543 . . . . . . . 545 . . . . . . . . . . . . . . . . . . . 546 Physical Devices Group Controller Table Channel Table 543 . . . . . . . . . . . . . . Storage Management Information Group . Global Data Group .
Logical Devices Group Virtual Disk Table . . . . . . . . . . . . . . . . . 641 . . . . . . . . . . . . . . . . . . 641 Array Disk Logical Connection Table . Storage Management Event Group . . . . . . . 650 . . . . . . . . . . . 653 24 Change Management Group Inventory Group Device Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 657 . . . . . . . . . . . . . . . . . . . . . . 658 . . . . . . . . . . . . . . . . 658 . . . . . . . . . . . . . . . . . . . .
DRsFirmwareVersion . Chassis Status . . . . . . . . . . . . . . . . 671 . . . . . . . . . . . . . . . . . . . . . 671 DRsGlobalSystemStatus DRsGlobalCurrStatus . DRsIOMCurrStatus . . . . . . . . . . . . . . . 671 672 . . . . . . . . . . . . . . . . 672 . . . . . . . . . . . . . . . . . 672 DRsPowerCurrStatus DRsFanCurrStatus 671 . . . . . . . . . . . . . . . . . DRsKVMCurrStatus DRsRedCurrStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673 . . . . . . . . . . . . . . . .
DRsCMC PSUTable . . . . . . . . . . . . . . . . . DRsCMC PSUTableEntry 681 . . . . . . . . . . . . . . . . . 681 . . . . . . . . . . . . . . . . . . 681 CMC Power Information DRsChassisIndex DRsPotentialPower . DRsIdlePower . . . . . . . . . . . . . . . . 681 . . . . . . . . . . . . . . . . . . . 682 DRsMaxPowerSpecification DRsPowerSurplus . . . . . . . . . . . . 682 . . . . . . . . . . . . . . . . . 682 . . . . . . . . . . . . . . . . 683 DRsKWhCumulative DRsKWhCumulativeTime . . .
DRsAlertSystem DRsAlertMessage . . . . . . . . . . . . . . 689 . . . . . . . . . . . . . . . . . 689 DRsAlertCurrentStatus . . . . . . . . . . . . . . . 690 DRsAlertPreviousStatus . . . . . . . . . . . . . . 690 . . . . . . . . . . . . . . . . . . . 690 DRsAlertData . 26 Traps 689 . . . . . . . . . . . . . . . . . . DRsAlertTableIndexOID . . . . . . . . . . . . . . . . . . . . . . . . . . . Trap Variables System . . . . . . . . . . . . . . . . . . . . . . 692 . . . . . . . . . . . . .
Pluggable Device Traps Battery Traps . . . . . . . . . . . . . . 721 . . . . . . . . . . . . . . . . . . . . 722 . . . . . . . . . . . . . . . 724 RAC Traps . . . . . . . . . . . . . . . . . . . . . . . . 725 BMC Traps . . . . . . . . . . . . . . . . . . . . . . . . 731 SD Card Device Traps 27 Storage Management Alert Reference 737 Alert Monitoring and Logging Viewing Alerts . . . . . . . . . . . . . . 737 . . . . . . . . . . . . . . . . . . . . . 738 Alert Severity Levels . . . . . .
B SNMP Sample Output Index . . . . . . . . . . . . . . 749 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents
1 Introduction This introduction is divided into two sections. The first section, "Introduction to the SNMP Reference Guide," explains the SNMP Reference Guide design. All essential Simple Network Management Protocol (SNMP) terms are defined in this section. Some of the vocabulary may seem complex and unfamiliar to system administrators who are using SNMP for the first time. SNMP experts can skim this section, and beginners can read the section more carefully.
What's New in Device Group • • • Added the following MIB objects to the Secure Digital (SD) Card Unit table: • sdCardUnitTable • sdCardUnitTableEntry • sdCardUnitChassisIndex • sdCardUnitIndex • sdCardUnitStateCapabilities • sdCardUnitStateSettings • sdCardUnitRedundancyStatus • sdCardUnitCountForRedundancy • sdCardUnitName • sdCardUnitStatus Added the following MIB objects to the SD Card Device table: • sdCardDeviceTable • sdCardDeviceTableEntry • sdCardDeviceChassisIndex • sd
• DellSDCardDeviceConfigCapabilities • DellSDCardDeviceConfigSettings • DellSDCardDeviceCardState What's New in Traps Added the following instrumentation trap: • alertSDCardDeviceFailure (1754) What's New in Power Group • Added the following MIB object to the Power Supply table: • • • powerSupplyRatedInputWattage Added the following MIB objects to the Power Usage table: • powerUsageIdlePower • powerUsageMaxPotentialPower • powerUsagePowerCapCapabilities • powerUsagePowerCapSetting • po
• • powerProfileCustomFanMgmtCapabilities • powerProfileCustomFanMgmtSetting Added the following Power Group variable values: • DellPowerCapSetting • DellPowerCapCapabilities • DellPowerProfileType • DellCPUPowerPerformanceManagementType • DellMemoryPowerPerformanceManagementType • DellFanPowerPerformanceManagementType Introduction to the SNMP Reference Guide This reference guide provides a formatted version of the Server Administrator Instrumentation MIB (filename 10892.
General Content Table 1-1 describes the sections that provide general information about the MIBs documented in this guide. Table 1-1. General Content Sections in This Guide Section Topics MIB Group Number 1 Introduction to SNMP basics and to the MIBs that support Server Administrator services NA 26 Traps — describes in-band traps defined in the Server 5000 Administrator Instrumentation MIB and out-of-band traps sent by the Remote Access Controller (RAC) and Baseboard Management Controller (BMC).
and lists the MIB group number assigned to the MIB group. The Server Administrator Instrumentation MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1., where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1-2.
Table 1-2.
The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table 1-3 describes each Server Administrator Remote Access MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Remote Access MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1. where is the MIB group number assigned to the MIB group.
is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1-4.
Server Administrator Change Management MIB The Server Administrator Change Management MIB (filename dellcm.mib) provides management data that allows you to monitor the inventory of devices and applications with SNMP management applications. Table 1-6 describes each Server Administrator Change Management MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Change Management MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.
Table 1-7. Dell RAC Out-of-Band MIB Section Topics 25 MIB Group Number The Dell RAC Out-of-Band MIB consists of information for 2 the following groups: • Product Information • Chassis Status • Chassis Power • CMC Power Information • CMC PSU Information • Chassis Alerts • Legacy Alerting How This Guide Defines Technical Terms The following table provides information about where to find definitions for technical terms in this reference guide. Table 1-8.
SNMP Basic Terminology It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the Glossary available on the Dell Support website at support.dell.com/manuals. SNMP Master Agent Typically, the SNMP agent on a managed system consists of one SNMP master agent and zero or more SNMP extension agents.
The Server Administrator SNMP subagent is an SNMP extension agent. Managed Object A managed object is any item in a computer system that can be singled out for discovery, monitoring, or user intervention and correction. NOTE: Not all managed objects described in this guide are supported by all systems. MIB A MIB acts as a structured road map for managed objects. As an Application Programming Interface (API), a MIB allows systems management tools to retrieve data maintained by an agent.
• Variable names start with a lowercase letter. • Spaces are not allowed between words in the variable name. • Acronyms are in uppercase letters, except when an acronym is the first word in the variable name. • With the exception of the first letter of the variable name and acronyms, all other words in the variable name start with capital letters.
Frequently Used Terms in Variable Names The following terms are frequently used in the name of a MIB variable: Capability refers to the actions an object can perform, or to actions that can be taken by the object. Hot-pluggable is an example of a capability. If a card is hot-pluggable, it can be replaced while a system is running. Capability settings refer to the capabilities of the object that the user can select from and activate if desired.
The following table is an example of an SNMP table. The table contains variables that must occur in a definite sequence. In the example table the defined variables are UUID Chassis Index, UUID Index, UUID Type, and UUID Value. Example SNMP Table UUID Table These objects comprise the Server Administrator definitions for the UUID. Name uUIDTable Object ID 1.3.6.1.4.1.674.10892.1.300.20 Description Defines the UUID table.
UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
Reference Guide Content Tables NOTE: Variable values are defined for any variable that is Server Administrator-specific. Industry-standard variable definitions are documented in "Standard Data Type Definitions." Some of the tables in this guide have no technical significance in SNMP. These tables are designed to show information in a readable form. The following table, for example, defines the Server Administrator-specific variable, DellFanControlCapabilities.
contains definitions for any Server Administrator-specific variables that are used in the section. The following example shows the typical content of these four sections: 1 BIOS Setup Control Group This section explains the purpose of the MIB group and summarizes the major features of the component groups. 2 BIOS Group Tables If there is more than one SNMP table for a group, this section lists all of the tables. For this BIOS group example, there are eight tables listed.
Other Documents You May Need In addition to this Server Administrator SNMP Reference Guide, you can find the following guides on the Dell Support website at support.dell.com/manuals. To access these documents, go to support.dell.
Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF). Structure of Management Information (SMI) is a standard that specifies the rules for defining the structure and type of managed objects and events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155. The Server Administrator MIB conforms to the SMIv1 standard. SNMP is a systems management standard originally designed for network management. SNMP manages much more than networks.
SNMP MIB OIDs Each data class within an MIB is defined by an OID. OIDs are unique across all MIBs. An OID consists of a series of digits separated by periods. The OID functions in a similar fashion to a phone number. The phone number 011-512-471-0000 uniquely identifies a single phone. The phone number can be broken down into a number of components to uniquely identify a phone. The first component, 011, is the country code for the United States.
In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674. The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values. SNMP Security SNMP version 1 has a very limited security mechanism. SNMP agents support the use of a community string, which is configured at each SNMP agent and is passed as a part of all SNMP request messages.
Management Actions Management actions can be performed using the SNMP Set command. These actions can consist of configuring a phone number for the system’s owner, rebooting a system, or changing the asset tag of the system. See the previous section, "SNMP Security," for limitations on Set operations. SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on.
2 Instrumentation MIB Version Group The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software. The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table. MIB Major Version Number Name mIBMajorVersionNumber Object ID 1.3.6.1.4.1.
MIB Minor Version Number Name mIBMinorVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.2.0 Description Defines the minor version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the minor version number is 2. A minor revision provides additional support for new objects as well as problem fixes. Syntax DellUnsigned8BitRange Access Read-only MIB Maintenance Version Number Name mIBMaintenanceVersionNumber Object ID 1.3.6.1.
Systems Management Software Group 3 The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports.
Systems Management Software The following objects describe the fields for server administrator systems management information. The systems management software variables are scalar objects, meaning that they are not related to other management information base (MIB) objects and are thus not placed in a table. Systems Management Software Name Name systemManagementSoftwareName Object ID 1.3.6.1.4.1.674.10892.1.100.1 Description Defines the systems management software product name.
Systems Management Software Description Name Name systemManagementSoftwareDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.100.4 Description Defines the description of the systems management software. Syntax DellString Access Read-only Systems Management Software Supported Protocol Name systemManagementSoftwareSupportedProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.5 Description Defines the systems management standards (SNMP or CIM) supported by the systems management software.
Systems Management Software URL Name Name systemManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10892.1.100.8 Description Defines the universal resource locator (URL) of the systems management software. Syntax DisplayString (SIZE (0..1024)) Access Read-only Systems Management Software Language Name Name systemManagementSoftwareLanguageName Object ID 1.3.6.1.4.1.674.10892.1.100.9 Description Defines the language of the systems management software. Syntax DisplayString (SIZE (0..
Systems Management Software SNMP Agent Feature Flags Name systemManagementSoftwareSNMPAgentFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.100.12 Description Defines the features of the SNMP agent software provided by the operating system. Syntax SMSSNMPAgentFeatureFlags (See Table 3-3) Access Read-only Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.
Table 3-2. Systems Management Software Feature Flags Variable Name: SMSFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value none(0) The Systems Management Software features are not enabled. webOneToOneManagementPreferred(1) The web 1:1 management preferred feature is enabled. Table 3-3.
4 System State Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes. System State Group Table The System State Group defines objects in the System State MIB table.
System State Chassis Index Name systemStatechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System State Global System Status Name systemStateGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.2 Description Defines the global system status of all chassis being monitored by this instrumentation instance.
System State Power Unit State Details Name systemStatePowerUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5 Description Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power unit. The first byte returned represents the state of the first power unit, the second byte returned represents the state of the second power unit, and so on.
System State Power Supply State Details Name systemStatePowerSupplyStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.8 Description Defines the state of all power supplies in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power supply. The first byte returned represents the state of the first power supply, the second byte returned represents the state of the second power supply, and so on.
System State Voltage State Details Name systemStateVoltageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11 Description Defines the state of all voltage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific voltage probe. The first byte returned represents the status of the first voltage probe, the second byte returned represents the status of the second voltage probe, and so on.
System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14 Description Defines the state of all current probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific current probe. The first byte returned represents the state of the first current probe, the second byte returned represents the state of the second current probe, and so on.
System State Cooling Unit State Details Name statesystemStateCoolingUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit. The first byte returned represents the state of the first cooling unit, the second byte returned represents the state of the second cooling unit, and so on.
System State Cooling Device State Details Name systemStateCoolingDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20 Description Defines the state of all cooling devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling device. The first byte returned represents the state of the first cooling device, the second byte returned represents the state of the second cooling device, and so on.
System State Temperature State Details Name systemStateTemperatureStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.23 Description Defines the state of all temperature probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific temperature probe. The first byte returned represents the state of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on.
System State Memory Device State Details Name systemStateMemoryDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26 Description Defines the state of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of the specific memory device. The first byte returned represents the state of the first memory device, the second byte returned represents the status of the second memory device, and so on.
System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device.
System State AC Power Switch State Details Name systemStateACPowerSwitchStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.32 Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on. Syntax OCTET STRING (SIZE(1..
System State AC Power Cord State Details Name systemStateACPowerCordStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.35 Description Defines the individual state of all AC power cords for any AC power switches in this chassis. The first byte returned represents the state of the first AC power cord, the second byte returned represents the state of the second AC power cord, and so on. Syntax OCTET STRING (SIZE(1..
System State Redundant Memory Unit State Details Name systemStateRedundantMemoryUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38 Description Defines the state of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the state of the specific object. The first byte returned represents the state of the first object, and so on. The bytes have the same definition type as DellStateSettings.
System State Event Log Status Name systemStateEventLogStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41 Description Defines the overall status of this chassis (ESM) event log. Syntax DellStatus Access Read-only System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42 Description Defines the combined status of all power units of this chassis.
System State Cooling Unit Status Combined Name systemStateCoolingUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.44 Description Defines the combined status of all cooling units of this chassis. Syntax DellStatus Access Read-only System State Cooling Unit Status List Name systemStateCoolingUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.45 Description Lists the status of each cooling unit of this chassis.
System State AC Power Switch Status List Name systemStateACPowerSwitchStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.47 Description Lists the status of each AC power switch of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of an AC power switch. The first byte returned represents the status of the first AC power switch, and so on. The bytes have the same definition type as DellStatus. Syntax OCTET STRING (SIZE(1..
System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50 Description Defines the combined status of all processor devices of this chassis. Syntax DellStatus Access Read-only System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.51 Description Lists the status of each processor device of this chassis.
Name systemStateBatteryStatusList Description Lists the status of each battery of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a battery. The first byte returned represents the status of the first battery, and so on. The bytes have the same definition type as DellStatus. Syntax OCTET STRING (SIZE(1..128)) Access Read-only System State SD Card Unit Status Combined Name systemStateSDCardUnitStatusCombined Object ID 1.3.
Name systemStateSDCardDeviceStatusCombined Syntax DellStatus Access Read-only System State SD Card Device Status List Name systemStateSDCardDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.57 Description Lists the status of each SD Card device of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a SD Card device. The first byte returned represents the status of the first SD Card device, and so on.
Chassis Information Group 5 The Chassis Information Group provides information about the type or types of chassis in your system, as well as information about the light-emitting diode (LED) indicators and settings for devices on each chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS), and so on.
Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.10.1 Description Defines the chassis information table entry. Syntax ChassisInformationTableEntry Access Not accessible Index chassisIndexChassisInformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1 Description Defines the index (one-based) of this chassis. The first chassis will be numbered one.
Chassis Status Name chassisStatus Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the status of the chassis. Syntax DellStatus Access Read-only Chassis Parent Index Reference Name chassisparentIndexReference Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the index (one-based) of the parent chassis of this chassis, if any. A zero (0) means that this chassis is the parent of all other chassis managed by the Server Administrator.
Chassis Manufacturer Name Name chassisManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8 Description Defines the manufacturer’s name for this chassis. Syntax DellString Access Read-only Chassis Model Name Name chassisModelName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.9 Description Defines the system model type for this chassis. Syntax DellString Access Read-only Chassis Asset Tag Name Name chassisAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis ID Name chassisID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.12 Description Defines the asset tag name for this chassis. Syntax DellUnsigned8BitRange Access Read-only Chassis ID Extension Name chassisIDExtension Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.13 Description Defines the SMBIOS machine ID of this chassis. Syntax DellUnsigned16BitRange Access Read-only Chassis System Class Name chassisSystemClass Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defines the boot time of this system. Syntax DellDateName Access Read-only Chassis System Date Name Name chassisSystemDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.17 Description Defines the current time on this system. Syntax DellDateName Access Read-only Chassis System Location Name Name chassisSystemLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.21 Description Defines the status of the connection from the system chassis to an expansion chassis.
Chassis LED Control Capabilities Unique Name chassisLEDControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.24 Description Defines the capabilities of the LED control function in the chassis. Syntax DellLEDControlCapabilities (See Table 5-5.) Access Read-only Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25 Description Defines the readings and settings of the LED control hardware in the chassis.
Chassis Identify Flash Control Capabilities Name chassisIdentifyFlashControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28 Description Specifies whether the chassis front-panel LED can be set to flash. Syntax DellChassisIdentifyControlCapabilities (See Table 5-9.) Access Read-only Chassis Identify Flash Control Settings Name chassisIdentifyFlashControlSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.29 Description Causes the chassis front-panel LED to flash.
Chassis Host Control Settings Unique Name chassishostControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.32 Description Defines the current settings of the host control object. Syntax DellHostControlSettings (See Table 5-12.) Access Read-write Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.33 Description Defines the capabilities of the watchdog timer object.
Chassis Watchdog Control Expiry Time Name chassiswatchDogControlExpiryTime Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.36 Description Defines the current reading and allows setting of the nonrecoverable watchdog expiry timer object. Syntax DellUnsigned16BitRange Access Read-write Chassis Allow Set Commands From SNMP Name chassisallowSETCommandsfromSNMP Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis Power Button Control Settings Unique Name chassisPowerButtonControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.39 Description Defines the current reading and allows setting of the power button control hardware. Syntax DellPowerButtonControlSettings (See Table 5-17) Access Read-write Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40 Description Defines the name of the chassis reseller. Syntax DisplayString (SIZE (0..
Chassis Reseller System ID Name chassisResellerSystemID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.43 Description Defines the chassis reseller system ID. Syntax DellUnsigned16BitRange Access Read-only Chassis NMI Button Control Capabilities Unique Name chassisNMIButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44 Description Defines the capabilities of the NMI button control function.
Chassis System Revision Number Name chassisSystemRevisionNumber Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.47 Description Defines the revision number of the system where zero indicates the original version of the system. The revision number is not available on all systems. Syntax DellUnsigned8BitRange Access Read-only Chassis System Revision Name Name chassisSystemRevisionName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.48 Description Defines the revision name of the system, if applicable.
UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex, uUIDchassisIndex UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax OCTET STRING (SIZE(16)) Access Read-only POST Log Table This section defines attributes for the power-on self-test (POST) log. When you turn on your computer, the POST checks various system components before the operating system loads. The POST tests the random-access memory (RAM), the hard drives, and the keyboard, for example.
POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only POST Log Record Index Name postLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.2 Description Defines the record number (one-based) of the POST log. Syntax DellUnsigned32BitRange Access Read-only POST Log State Capabilities Unique Name postLogStateCapabilitiesUnique Object ID 1.3.6.1.4.
POST Log Record Name postLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines the data for the specified chassis and record index in the POST log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines format of the POST log. Syntax DellLogFormat (See Table 5-1.) Access Read-only Event Log Table Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.
Event Log Chassis Index Name eventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Event Log Record Index Name eventLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.2 Description Defines the record index of the event log. Syntax DellUnsigned32BitRange Access Read-only Event Log State Capabilities Unique Name eventLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.
Event Log Record Name eventLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.5 Description Defines the data for the specified chassis and log record index in the event log being returned. Syntax DisplayString (SIZE (0..1024)) Access Read-only Event Log Format Name eventLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.6 Description Defines the format of the event log. Syntax DellLogFormat (See Table 5-1.
System BIOS Table This table lists objects that define the system’s basic input/output system (BIOS). Name systemBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.300.50 Description Defines the System BIOS Table. Syntax SEQUENCE OF SystemBIOSTableEntry Access Not accessible System BIOS Table Entry Name systemBIOSTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.50.1 Description Defines the System BIOS Table entry.
System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.3 Description Defines the capabilities of the system BIOS of this object. Syntax DellStateCapabilities Access Read-only System BIOS State Settings Name systemBIOSStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.4 Description Defines the state of the system BIOS of this object. Syntax DellStateSettings Access Read-write System BIOS Status Name systemBIOSStatus Object ID 1.
System BIOS Release Date Name Name systemBIOSReleaseDateName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.7 Description Defines the release date of the system BIOS. Syntax DellDateName Access Read-only System BIOS Version Name Name systemBIOSVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.8 Description Defines the version name of the system BIOS. Syntax DellString Access Read-only System BIOS Starting Address Name systemBIOSStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.
System BIOS Manufacturer Name Name systemBIOSManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.11 Description Defines the system BIOS manufacturer’s name. Syntax DellString Access Read-only System BIOS Characteristics Name systemBIOSCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.12 Description Defines characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Name systemBIOSCharacteristics Description Bit Position Meaning if Set -------------- -----------------Bit 16Selectable Boot is supported Bit 17BIOS ROM is socketed Bit 18Boot From PC Card (PCMCIA) is supported Bit 19EDD (Enhanced Disk Drive) Specification is supported Bit 20Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is supported Bit 21Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in, 360 RPM) is supported Bit 22Int 13h - 5.
System BIOS Characteristics Ext 1 Name systemBIOSCharacteristicsExt1 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.13 Description Defines additional characteristics of the system basic input/output system (BIOS). This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Firmware Table Name firmwareTable Object ID 1.3.6.1.4.1.674.10892.1.300.60 Description Defines the Firmware Table. Syntax SEQUENCE OF FirmwareTableEntry Access Not accessible Firmware Table Entry Name firmwareTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.60.1 Description Defines the Firmware Table entry. Syntax FirmwareTableEntry Access Not accessible Index firmwarechassisIndex, firmwareIndex Firmware Chassis Index Name firmwarechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.
Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.3 Description Defines the capabilities of the firmware states. Syntax DellStateCapabilities Access Read-only Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.4 Description Defines the state of the firmware and allows for the setting of the firmware.
Firmware Type Name firmwareType Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7 Description Defines the type of the firmware. Syntax DellFirmwareType Access Read-only Firmware Type Name Name firmwareTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8 Description Defines the name of firmware type. Syntax DellString Access Read-only Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
Firmware Version Name Name firmwareVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11 Description Defines the version name of the firmware. Syntax DellString Access Read-only Intrusion Table The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of a computer is removed. Name intrusionTable Object ID 1.3.6.1.4.1.674.10892.1.300.70 Description Defines the Intrusion Table.
Intrusion Index Name intrusionIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.2 Description Defines the index of the intrusion objects in this subgroup. Syntax DellObjectRange Access Read-only Intrusion State Capabilities Name intrusionStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.3 Description Defines the capabilities of the intrusion object. Syntax DellStateCapabilities Access Read-only Intrusion State Settings Name intrusionStateSettings Object ID 1.3.6.1.4.1.674.
Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.6 Description Defines the reading of the intrusion object. Syntax DellIntrusionReading Access Read-only Intrusion Type Name intrusionType Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.7 Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Intrusion Location Name Name intrusionLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.
Baseboard Table Entry Name baseBoardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.80.1 Description Defines the Baseboard Table entry. Syntax BaseBoardTableEntry Access Not accessible Index baseBoardChassisIndex, baseBoardIndex Baseboard Chassis Index Name baseBoardChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Baseboard Index Name baseBoardIndex Object ID 1.3.6.
Baseboard State Settings Name baseBoardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.4 Description Defines the state settings of the baseboard. Syntax DellStateSettings Access Read-write Baseboard Status Name baseBoardStatus Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.5 Description Defines the status of the baseboard. Syntax DellStatus Access Read-only Baseboard Feature Flags Name baseBoardFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.
Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8 Description Defines the name of the type of baseboard. Syntax DellString Access Read-only Baseboard Location Name Name baseBoardLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.9 Description Defines the location name of the baseboard. Syntax DellString Access Read-only Baseboard Manufacturer Name Name baseBoardManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.
Baseboard Version Name Name baseBoardVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.12 Description Defines the baseboard version name. Syntax DellString Access Read-only Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13 Description Defines the baseboard service tag name. Syntax DellString Access Read-only Baseboard Piece Part ID (PPID) Name Name baseBoardPiecePartIDName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.
Chassis Information Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 5-1. Log Format Variable Name: DellLogFormat Data Type: Integer Possible Data Values Meaning of Data Value raw(1) The log is in the format received from the firmware. ascii(2) The log is in ASCII format. uniCode(3) The log is in Unicode format. Table 5-2.
Table 5-2. Chassis Type (continued) Variable Name: DellChassisType Data Type: Integer Possible Data Values Meaning of Data Value subNoteBook(14) The chassis type is a subnotebook. spaceSaving(15) The chassis type is a spacesaver. lunchBox(16) The chassis type is a lunch box. mainSystemChassis(17) The chassis type is the main system chassis. expansionChassis(18) The chassis type is an expansion chassis. subChassis(19) The chassis type is a subchassis.
Table 5-4. Fan Control Capabilities Variable Name: DellFanControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The fan’s capabilities are unknown. lowSpeedCapable(2) The fan can be set to low speed. highSpeedCapable(4) The fan can be set to high speed. lowOrHighSpeedCapable(6) The fan can be set to low or high speed. Table 5-5.
Table 5-7. Hard-Drive Fault LED Control Capabilities Variable Name: DellHDFaultLEDControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The hard drive has no fault LED capabilities. unknownCapabilities(1) The hard-drive fault LED capabilities are unknown. enableCapable(2) The hard-drive fault LED can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The hard-drive fault LED can indicate not ready.
Table 5-9. Chassis Identification Control Capabilities Variable Name: DellChassisIdentifyControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LEDs do not have any chassis identification capabilities. unknownCapabilities(1) The chassis identification control’s capabilities are unknown. enableCapable(2) The chassis identification controls can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
Table 5-10. Chassis Identification Control Settings (continued) Variable Name: DellChassisIdentifyControlSettings Data Type: Integer Possible Data Values Meaning of Data Value identifyChassis(8) The chassis identification control’s LEDs may be returned to (normal) 0, or (identify chassis) 1. identifyChassisAndEnable The chassis identification control’s (10) LEDs may be returned to normal (a binary 0 value), or identify chassis and enabled (a binary 1 value). Table 5-11.
Table 5-11. Host Control Capabilities (continued) Variable Name: DellHostControlCapabilities NOTE: An operator can manually enable these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualRebootWithoutOSShut The operator can reboot without downCapable(32) operating system shutdown. manualPowerOffWithOSShutd The operator can power off with operating ownCapable(64) system shutdown.
Table 5-12. Host Control Settings (continued) Variable Name: DellHostControlSettings NOTE: An operator can manually cause these actions using SNMP. Data Type: Integer Possible Data Values Meaning of Data Value manualOperatingSystemShutdownThe The operator can shut down the nPowerOFF(10) operating system on the host then power off machine. manualOperatingSystemShutdownThe The operator can shut down the nPowerCycle(12) operating system on the host then power cycle machine. Table 5-13.
Table 5-14. Watchdog Control Settings Variable Name: DellWatchControlSettings NOTE: The watchdog timer is the mechanism used by a chassis to determine if the operating system has stopped responding. Data Type: Integer Possible Data Values Meaning of Data Value automaticRebootEnabled(1) Automatic reboot is enabled for this host. automaticPowerCycleEnabled(2) Automatic power cycleable is enabled for this host. automaticNotificationEnabled(4) Automatic notification is enabled for this host.
Table 5-16. Power Button Control Capabilities Variable Name: DellPowerButtonControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The power button has no capabilities. unknownCapabilities(1) The power button capabilities are unknown. enableCapable(2) Table 5-17. The power button can be enabled (online) or disabled (offline).
Table 5-19. NMI Button Control Settings Variable Name: DellNMIButtonControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The NMI button has no settings capabilities. unknown(1) The NMI button settings are unknown. enabled(2) The NMI button state is enabled. disabled(4) The NMI button state is disabled. Table 5-20. System Properties Variable Name: DellSystemProperties NOTE: These values are bit masks, so combination values are possible.
Table 5-22. Firmware Type Variable Name: DellFirmwareType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The firmware type is other than following values. unknown(2) The firmware type is unknown. systemBIOS(3) The firmware type is System BIOS embeddedSystemManagementContro The firmware type is Embedded ller(4) System Management Controller. powerSupplyParallelingBoard(5) The firmware type is Power Supply Paralleling Board.
Table 5-22. Firmware Type (continued) Variable Name: DellFirmwareType Data Type: Integer Possible Data Values Meaning of Data Value rac(16) The firmware type is Remote Access Controller. iDRAC(17) The firmware type is Integrated Dell Remote Access Controller. Table 5-23. Baseboard Type Variable Name: DellBaseBoardType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The baseboard type is unknown. other(2) The baseboard type is not one of the following types.
Table 5-24. Baseboard Feature Flags Variable Name: DellBaseBoardFeatureFlags Data Type: Integer Possible Data Values Meaning of Data Value NOTE: These values are bit fields, so combination values are possible. no features(0) This baseboard has no feature flags. boardIsHostingBoard(1) This baseboard is a hosting board. boardRequiresDaughterBoard This baseboard requires at least one (2) daughter board or auxiliary card. boardIsRemovable(4) This baseboard is removable.
Operating System Group 6 The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, service pack, and patch level of the installed operating system.
Operating System Chassis Index Name operatingSystemchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Operating System State Capabilities Name operatingSystemStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.2 Description Defines the capabilities of the operating system.
Operating System Is Primary Name operatingSystemIsPrimary Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.5 Description Specifies whether this operating system is the primary operating system. Syntax DellBoolean Access Read-only Operating System Name Name operatingSystemOperatingSystemName Object ID 1.3.6.1.4.1.674.10892.1.400.10.1.6 Description Defines the name of the operating system running on the system. Syntax DisplayString (SIZE (0..
Operating System Memory Table Entry Name operatingSystemTableEntry Object ID 1.3.6.1.4.1.674.10892.1.400.20.1 Description Defines the Operating System Memory Table entry. Syntax OperatingSystemMemoryTableEntry Access Not accessible Index operatingSystemMemorychassisIndex Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.1 Description Defines the index (one-based) of this chassis.
Operating System Memory Status Name operatingSystemMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.4 Description Defines the status of the operating system memory. Syntax DellStatus Access Read-only Operating System Memory Total Physical Size Name operatingSystemMemoryTotalPhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.5 Description Defines the total physical memory size in kilobytes.
Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8 Description Defines the available page file memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.9 Description Defines the total virtual memory size in kilobytes.
System Resource Group 7 The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes System Resource Group Tables that track variables such as the owner, ports, system memory, interrupts, and direct memory access.
System Resource Map Table Entry Name systemResourceMapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.10.1 Description Defines the System Resource Map Table entry. Syntax SystemResourceMapTableEntry Access Not accessible Index systemResourceMapchassisIndex, systemResourceMapIndex System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1 Description Defines the index (one-based) of this chassis.
System Resource Map State Settings Name systemResourceMapStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.4 Description Defines the state and allows the setting of this system map. Syntax DellStateSettings Access Read-write System Resource Map Status Name systemResourceMapStatus Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.5 Description Defines the status of this system map. Syntax DellStatus Access Read-only System Resource Map Type Name systemResourceMapType Object ID 1.3.6.1.
System Resource Owner Table Entry Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20.1 Description Defines the System Resource Owner Table entry. Variables in this group reference the System Resource Map index. Syntax SystemResourceOwnerTableEntry Access Not accessible Index systemResourceOwnerchassisIndex, systemResourceOwnerIndex System Resource Owner Chassis Index Name systemResourceOwnerchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.
System Resource Owner State Settings Name systemResourceOwnerStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4 Description Defines the state settings of this system resource owner. Syntax DellStateSettings Access Read-write System Resource Owner Status Name systemResourceOwnerStatus Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.5 Description Defines the status of this system resource owner.
System Resource Owner Description Name Name systemResourceOwnerDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.8 Description Defines the description name of the system resource owner. Syntax DellString Access Read-only System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.9 Description Defines the associated system resource owner interface instance in this chassis.
System Resource I/O Port Chassis Index Name systemResourceIOPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2 Description Defines the index (one-based) of the system resource I/O ports in this chassis.
System Resource I/O Port Status Name systemResourceIOPortStatus Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.5 Description Defines the status of the system resource I/O port. Syntax DellStateSettings Access Read-only System Resource I/O Port Owner Index Reference Name systemResourceIOPortOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.6 Description Defines the index to the associated system resource owner in this chassis.
System Resource I/O Port Ending Address Name systemResourceIOPortEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.9 Description Defines the 64 bits of the ending address of the system resource I/O port. Syntax DellUnsigned64BitRange Access Read-only System Resource Memory Table Name systemResourceMemoryTable Object ID 1.3.6.1.4.1.674.10892.1.500.40 Description Defines the System Resource Memory Table.
System Resource Memory Index Name systemResourceMemoryIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2 Description Defines the index of system resource memory in this chassis. Syntax DellObjectRange Access Read-only System Resource Memory State Capabilities Name systemResourceMemoryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.3 Description Defines the capabilities of this system resource memory.
System Resource Memory Owner Index Reference Name systemResourceMemoryOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.7 Description Defines the share disposition of the system resource memory.
System Resource Memory Flags Name systemResourceMemoryFlags Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.10 Description Defines the permission flags for the system resource memory. Syntax DellResourceMemoryFlags (See Table 7-4.) Access Read-only System Resource Interrupt Table Name systemResourceInterruptTable Object ID 1.3.6.1.4.1.674.10892.1.500.50 Description Defines the System Resource Interrupt Table.
System Resource Interrupt Index Name systemResourceInterruptIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.2 Description Defines the index (one-based) of this interrupt resource. Syntax DellObjectRange Access Read-only System Resource Interrupt State Capabilities Name systemResourceInterruptStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.3 Description Defines the capabilities of this system resource interrupt.
System Resource Interrupt Owner Index Reference Name systemResourceInterruptOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.6 Description Defines the index for the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource Interrupt Owner Share Disposition Name systemResourceInterruptShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.7 Description Defines the share disposition of the system resource interrupt.
System Resource Interrupt Trigger Name systemResourceInterruptTrigger Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10 Description Defines the interrupt trigger of the system resource interrupt. Syntax DellResourceInterruptTrigger (See Table 7-6.) Access Read-only System Resource Direct Memory Access (DMA) Table Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.60 Description Defines the System Resource DMA Table.
System Resource DMA Index Name systemResourceDMAIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.2 Description Defines the index of system resource DMAs in this chassis. Syntax DellObjectRange Access Read-only System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA.
System Resource DMA Owner Index Reference Name systemResourceDMAOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only System Resource DMA Share Disposition Name systemResourceDMAShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.7 Description Defines the share disposition of the system resource DMA.
System Resource DMA Bus Master Name systemResourceDMABusMaster Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.10 Description Defines the bus mastering capabilities of the system resource DMA. Syntax DellResourceDMABusMaster (See Table 7-7.) Access Read-only System Resource Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 7-1.
Table 7-2. Resource Owner Interface Type (continued) Variable Name: DellResourceOwnerInterfaceType Data Type: Integer Possible Data Values Meaning of Data Value typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus. typeIsMCA(6) The interface type is a microchannel architecture (MCA) bus. typeIsTurboChannel(7) The interface type is a turbo-channel bus. Table 7-3.
Table 7-5. Resource Interrupt Type Variable Name: DellResourceInterruptType Data Type: Integer Possible Data Values Meaning of Data Value interruptIsLevelSensitive(1) The interrupt type is level sensitive. The interrupt type is latched. interruptIsLatched(2) Table 7-6. Resource Interrupt Trigger Variable Name: DellResourceInterruptTrigger Data Type: Integer Possible Data Values Meaning of Data Value interruptIsActiveWhenLow(1) The interrupt trigger is active on a low signal.
Table 7-8. Resource DMA Transfer Width Variable Name: DellResourceDMATransferWidth Data Type: Integer Possible Data Values Meaning of Data Value dmaTransferWidthIsOther(1) The DMA transfer width is not one of the following: dmaTransferWidthIsunknown(2) The DMA transfer width is unknown. dmaTransferWidthIs8Bits(3) The DMA transfer width is 8 bits. dmaTransferWidthIs16Bits(4) The DMA transfer width is 16 bits. dmaTransferWidthIs32Bits(5) The DMA transfer width is 32 bits.
System Resource Group
8 Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes.
Power Unit Table Entry Name powerUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.10.1 Description Defines the Power Unit Table entry. Syntax DellObjectRange Access Read-only Index powerUnitchassisIndex, powerUnitIndex Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Power Unit Index Name powerUnitIndex Object ID 1.3.6.1.4.1.674.
Power Unit State Settings Name powerUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.4 Description Defines the state and settings of the power unit. Syntax DellStateSettings Access Read-write Power Unit Redundancy Status Name powerUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.5 Description Defines the redundancy status of the power unit.
Power Unit Status Name powerUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.8 Description Defines the status of the power unit in this chassis. Syntax DellStatus Access Read-only Power Supply Table Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10892.1.600.12 Description Defines the Power Supply Table. Syntax PowerSupplyTableEntry Access Not accessible Power Supply Table Entry Name powerSupplyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.12.
Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.3 Description Defines the capabilities of the power supply. Syntax DellPowerSupplyStateCapabilitiesUnique (See Table 8-1.
Power Supply Output Watts Name powerSupplyOutputWatts Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.6 Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerSupplyType (See Table 8-3.
Power Supply Power Unit Index Reference Name powerSupplypowerUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.10 Description Defines the index to the associated system power unit in this chassis. Syntax DellObjectRange Access Read-only Power Supply Sensor State Name powerSupplySensorState Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.11 Description Defines the state reported by the power supply sensor, and supplements the state and settings of the power supply.
Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14 Description Defines the rated input wattage of the power supply (in tenths of Watts.) Syntax DellSigned32BitRange Access Read-only Voltage Probe Table Name voltageProbeTable Object ID 1.3.6.1.4.1.674.10892.1.600.20 Description Defines the Voltage Probe Table.
Voltage Probe Index Name voltageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.2 Description Defines the index of voltage probes in this chassis. Syntax DellObjectRange Access Read-only Voltage Probe State Capabilities Name voltageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.3 Description Defines the capabilities of the voltage probe. Syntax DellStateCapabilities Access Read-only Voltage Probe State Settings Name voltageProbeStateSettings Object ID 1.3.6.1.
Voltage Probe Reading Name voltageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6 Description Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Voltage Probe Type Name voltageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
Name voltageProbeUpperNonRecoverableThreshold Access Read-only Voltage Probe Upper Critical Threshold Name voltageProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.10 Description Defines the value of the voltage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
Voltage Probe Lower Critical Threshold Name voltageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.13 Description Defines the value of the voltage probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Voltage Probe Lower Nonrecoverable Threshold Name voltageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.14 Description Defines the value of the voltage probe’s lower nonrecoverable threshold.
Voltage Probe Discrete Reading Name voltageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.16 Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.
Amperage Probe Chassis Index Name amperageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Amperage Probe Index Name amperageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.2 Description Defines the index of amperage probes in this chassis. Syntax DellObjectRange Access Read-only Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.
Amperage Probe Status Name amperageProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.5 Description Defines the status of the amperage probe. Syntax DellSigned32BitRange Access Read-only Amperage Probe Reading Name amperageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.6 Description Defines the reading for an amperage probe of type other than amperageProbeTypeIsDiscrete.
Amperage Probe Type Name amperageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.7 Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.8 Description Defines the location name of the amperage probe in this chassis.
Amperage Probe Upper Noncritical Threshold Name amperageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.11 Description Defines the user-assigned value of the amperage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-write Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
Amperage Probe Lower Nonrecoverable Threshold Name amperageProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.14 Description Defines the value of the amperage probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Amperage Probe Probe Capabilities Name amperageProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.15 Description Defines the probe capabilities of the amperage probe.
AC Power Switch Table Name aCPowerSwitchTable Object ID 1.3.6.1.4.1.674.10892.1.600.40 Description Defines the AC Power Switch Table. Syntax SEQUENCE OF ACPowerSwitchTableEntry Access Not accessible AC Power Switch Table Entry Name aCPowerSwitchTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.40.1 Description Defines the AC Power Switch Table entry.
AC Power Switch Capabilities Name aCPowerSwitchCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.3 Description Defines the capabilities of this AC power switch. Syntax DellACPowerSwitchCapabilities Access Read-only AC Power Switch Settings Name aCPowerSwitchSettings Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.4 Description Defines the settings of this AC power switch.
AC Power Switch Name Name aCPowerSwitchName Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.7 Description Defines the name of this AC power switch. Syntax DellString Access Read-only AC Power Switch Redundancy Mode Name aCPowerSwitchRedundancyMode Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.8 Description Defines the redundancy mode of this AC power switch. Syntax DellACPowerSwitchRedundancyMode Access Read-write AC Power Switch Status Name aCPowerSwitchStatus Object ID 1.3.6.1.4.1.674.
AC Power Cord Table Entry Name aCPowerCordTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.42.1 Description Defines the AC Power Cord Table entry. Syntax ACPowerCordTableEntry Access Not accessible Index aCPowerCordchassisIndex, aCPowerCordIndex AC Power Cord Chassis Index Name aCPowerCordChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.1 Description Defines the index (one-based) of the chassis containing this AC power cord.
AC Power Cord State Settings Name aCPowerCordStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.4 Description Defines the settings of this AC power cord. Syntax DellACPowerCordStateSettings Access Read-write AC Power Cord Status Name aCPowerCordStatus Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.5 Description Defines the status of this AC power cord.
Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.1 Description Defines the Battery Table Entry. Syntax BatteryTableEntry Access Not accessible Index batteryChassisIndex, batteryIndex Battery Chassis Index Name batteryChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.
Battery State Capabilities Name batteryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.3 Description Defines the state capabilities of the battery. Syntax DellStateCapabilities Access Read-only Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-write Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.
Battery Location Name Name batteryLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.7 Description Defines the location of the battery. Syntax DellString Access Read-only Power Usage Table Name powerUsageTable Object ID 1.3.6.1.4.1.674.10892.1.600.60 Description Defines the Power Usage Table. Syntax SEQUENCE OF PowerUsageTableEntry Access Not accessible Power Usage Table Entry Name powerUsageTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.60.
Power Usage Index Name powerUsageIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.2 Description Defines the index (one-based) of the power usage information. Syntax DellObjectRange Access Read-only Power Usage State Capabilities Name powerUsageStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.3 Description Defines the state capabilities of the power usage information.
Power Usage Entity Name Name powerUsageEntityName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.6 Description Defines the name of the entity associated with this power usage information. Syntax DellString Access Read-only Power Usage Cumulative Wattage Name powerUsageCumulativeWattage Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.7 Description Defines the total wattage used (in Watt-hours) by this entity since the date and time specified by the powerUsageCumulativeWattageStartDateName attribute.
Name powerUsagePeakWatts Description Defines the peak wattage reading (in Watts) for this entity since the date and time specified by the powerUsagePeakWattsStartDateName attribute. Syntax DellUnsigned32BitRange Access Read-only Power Usage Peak Watts Start Date Name Name powerUsagePeakWattsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.10 Description Defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute.
Power Usage Peak Watts Reading Date Name Name powerUsagePeakWattsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.11 Description Defines the date and time at which the value reported by the powerUsagePeakWatts attribute was measured. Syntax DellDateName Access Read-only Power Usage Peak Amps Name powerUsagePeakAmps Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Name powerUsagePeakAmpsReadingDateName Syntax DellDateName Access Read-only Power Usage Idle Power Name powerUsageIdlePower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.15 Description Defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only Power Usage Max Potential Power Name powerUsageMaxPotentialPower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Power Usage Power Cap Setting Name powerUsagePowerCapSetting Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.18 Description Defines the system power cap setting. Syntax DellPowerCapSetting Access Read-only Power Usage Power Cap Value Name powerUsagePowerCapValue Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.19 Description Defines the system power cap value (in Watts).
Name powerUsagePeakHeadroom Access Read-only Power Profile Table Name powerProfileTable Object ID 1.3.6.1.4.1.674.10892.1.600.70 Description Defines the Power Profile Table. Syntax SEQUENCE OF PowerProfileTableEntry Access Not accessible Power Profile Table Entry Name powerProfileTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.70.1 Description Defines the Power Profile Table Entry.
Name powerProfileIndex Syntax DellObjectRange Access Read-only Power Profile Supported Profiles Name powerProfileSupportedProfiles Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.3 Description Defines the supported power profiles. Syntax DellPowerProfileType Access Read-only Power Profile Setting Name powerProfileSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.4 Description Defines the power profile setting.
Name powerProfileCustomCPUMgmtSetting Description Defines the custom CPU power and performance management setting for the Custom power profile. Syntax DellCPUPowerPerformanceManagementType Access Read-only Power Profile Custom Memory Mgmt Capabilities Name powerProfileCustomMemoryMgmtCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.7 Description Defines the custom memory power and performance management capabilities that are available for the Custom power profile.
Power Profile Custom Fan Mgmt Setting Name powerProfileCustomFanMgmtSetting Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.10 Description Defines the custom fan power and performance management setting for the Custom power profile. Syntax DellFanPowerPerformanceManagementType Access Read-only Power Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 8-1.
Table 8-2. Power Supply State Settings Unique (continued) Variable Name: DellPowerSupplyStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value onlineAndFanFailure(10) The power supply is online and indicating that its fan is not working. powerSupplyIsON(16) The power supply is indicating that it is on. powerSupplyIsOk(32) The power supply is indicating that it is OK. acSwitchIsON(64) The power supply is indicating that the AC power switch is on.
Table 8-3. Power Supply Type Definitions (continued) Variable Name: DellPowerSupplyType Data Type: Integer Possible Data Values Meaning of Data Value powerSupplyTypeIsSwitching(4) The power supply type is a switching power supply. powerSupplyTypeIsBattery(5) The power supply type is a battery. powerSupplyTypeIsUPS(6) The power supply type is an uninterruptable power supply. powerSupplyTypeIsConverter(7) The power supply type is a power converter power supply.
Table 8-4. Power Supply Sensor State (continued) Variable Name: DellPowerSupplySensorState Data Type: Integer Possible Data Values Meaning of Data Value acOutOfRangeButPresent(32) The power supply’s AC power is present, but it is out of range. configurationError(64) The power supply sensor detects a configuration error. Table 8-5.
Table 8-6. Voltage Probe Type (continued) Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIs3Point3Volt The voltage probe type is a 3.3-V probe. (4) voltageProbeTypeIs5Volt(5) The voltage probe type is a 5-V probe. voltageProbeTypeIsMinus5Volt The voltage probe type is a –5-V probe. (6) voltageProbeTypeIs12Volt(7) The voltage probe type is a 12-V probe. voltageProbeTypeIsMinus12Volt The voltage probe type is a –12-V probe.
Table 8-7. Voltage Probe Discrete Reading Variable Name: DellVoltageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value voltageIsGood(1) The voltage probe discrete reading is good. voltageIsBad(2) The voltage probe discrete reading is bad. Table 8-8.
Table 8-8. Amperage Probe Definitions (continued) Variable Name: DellAmperageType Data Type: Integer Possible Data Values Meaning of Data Value amperageProbeTypeIsFLEA(11) The amperage probe type is a FLEA (standby) amperage probe. amperageProbeTypeIsBattery(12) The amperage probe type is a battery amperage probe. amperageProbeTypeIsTerminator(13) The amperage probe type is a Small Computer System Interface (SCSI) termination amperage probe.
Table 8-9. Amperage Probe Discrete Reading Variable Name: DellAmperageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value amperageIsGood(1) The amperage probe discrete reading is good. amperageIsBad(2) The amperage probe discrete reading is bad. Table 8-10. AC Power Switch Capabilities Variable Name: DellACPowerSwitchCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknownCapabilities(1) The AC power switch’s capabilities are unknown.
Table 8-11. AC Power Switch Settings (continued) Variable Name: DellACPowerSwitchSettings Data Type: Integer Possible Data Values Meaning of Data Value inputSourceCord1Return(4) Input source is AC power cord 1, with return. inputSourceCord2NoReturn(8) Input source is AC power cord 2, with no return. inputSourceCord2Return(16) Input source is AC power cord 2, with return. inputSourceShared(32) Input source is shared. Table 8-12.
Table 8-14. AC Power Cord State Settings Variable Name: DellACPowerCordStateSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power cord’s state is unknown. online(2) The AC power cord’s state is disabled (offline) 0 or enabled (online) 1. notReady(4) The AC power cord’s state is not ready. acPowerCordHasPower The AC power cord has power. (8) acPowerCordIsActive The AC power cord is the active source of Source(16) AC power. Table 8-15.
Table 8-16. Power Cap Capabilities Variable Name: DellPowerCapCapabilities Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value disable(2) Power cap can be disabled. Table 8-17. Power Cap Setting Variable Name: DellPowerCapSetting Data Type: Integer Possible Data Values Meaning of Data Value disabled(0) Power cap is disabled. enabled(1) Power cap is enabled. Table 8-18.
Table 8-19. CPU Power Performance Management Type Variable Name: DellCPUPowerPerformanceManagementType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) CPU power and performance management type is Maximum Performance. minPower(2) CPU power and performance management type is Minimum Power. osDBPM(4) CPU power and performance management type is OS Demand Based Power Management.
Table 8-21. Fan Power Performance Management Type Variable Name: DellFanPowerPerformanceManagementType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Fan power and performance management type is Maximum Performance. minPower(2) Fan power and performance management type is Minimum Power.
9 Thermal Group The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes.
Cooling Unit Chassis Index Name coolingUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.1 Description Defines the index (one-based) of this chassis. Syntax TableEntry Access Read-only Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units. Syntax DellObjectRange Access Read-only Cooling Unit State Capabilities Name coolingUnitStateCapabilties Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.
Cooling Unit Redundancy Status Name coolingUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.5 Description Defines the redundancy status of the cooling unit. Syntax DellStatusRedundancy Access Read-only Cooling Device Count For Redundancy Name coolingDeviceCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.6 Description Defines the total number of cooling devices required for this cooling unit to have redundancy.
Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.700.12 Description Defines the Cooling Device Table. Syntax CoolingDeviceTableEntry Access Not accessible Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.12.1 Description Defines the Cooling Device Table entry.
Cooling Device State Capabilities Name coolingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.3 Description Defines the capabilities of the cooling device. Syntax DellStateCapabilities Access Read-only Cooling Device State Settings Name coolingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.4 Description Defines the state and settings of the cooling device.
Cooling Device Reading Name coolingDeviceReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.6 Description Defines either the cooling device’s speed in revolutions per minute (RPM), or the off/on value of the fan. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the speed in RPM or the OFF/ON value of the cooling device.
Cooling Device Upper Nonrecoverable Threshold Name coolingDeviceUppernonrecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.9 Description Defines the value of the fan’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.10 Description Defines the value of the fan’s upper critical threshold.
Cooling Device Lower Critical Threshold Name coolingDeviceLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.13 Description Defines the value of the fan’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Cooling Device Lower Nonrecoverable Threshold Name coolingDeviceLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.14 Description Defines the value of the fan’s lower nonrecoverable threshold.
Cooling Device Probe Capabilities Name coolingDeviceProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.17 Description Defines the probe capabilities of the cooling device. Syntax DellProbeCapabilities Access Read-only Cooling Device Discrete Reading Name coolingDeviceDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.18 Description Defines the reading for a voltage probe of type coolingDeviceSubTypeIsDiscrete.
Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.20.1 Description Defines the Temperature Probe Table entry. Syntax TemperatureProbeTableEntry Access Not accessible Index temperatureProbechassisIndex, temperatureProbeIndex Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.1 Description Defines the index (one-based) of this chassis.
Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-write Temperature Probe Status Name temperatureProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.5 Description Defines the status of the temperature probe in tenths of degrees Celsius.
Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.7 Description Defines the temperature probe type. Syntax DellTemperatureProbeType (See Table 9-4.) Access Read-only Temperature Probe Location Name Name temperatureProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.8 Description Defines the location of the temperature probe in this chassis.
Temperature Probe Upper Noncritical Threshold Name temperatureProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.11 Description Defines the user-assigned value of the temperature probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Temperature Probe Probe Capabilities Name temperatureProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.15 Description Defines the probe capabilities of the temperature probe. Syntax DellProbeCapabilities Access Read-only Temperature Probe Discrete Reading Name temperatureProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.16 Description Defines the reading for a temperature probe of type temperatureProbeTypeIsDiscrete.
Thermal Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 9-1. Cooling Device Type Variable Name: DellCoolingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther(1) The cooling device type is not one of the following: coolingDeviceTypeIsUnknown(2) The cooling device type is unknown (not known or not monitored). coolingDeviceTypeIsAFan(3) The cooling device type is a fan.
Table 9-2. Cooling Device Subtype Variable Name: DellCoolingDeviceSubType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceSubTypeIsOther(1) The cooling device subtype is not one of the following: coolingDeviceSubTypeIsUnknown(2) The cooling device subtype is unknown (not known or not monitored). coolingDeviceSubTypeIsAFanThatReads The cooling device subtype is a InRPM(3) fan that reads in RPMs.
Table 9-4. Temperature Probe Type Variable Name: DellTemperatureProbeType Data Type: Integer Possible Data Values Meaning of Data Value temperatureProbeTypeIsOther(1) The temperature probe subtype is not one of the following: temperatureProbeTypeIsUnknown(2) The temperature probe subtype is unknown (not known or not monitored). temperatureProbeTypeIsAmbientESM(3) The temperature probe is for ambient Embedded Systems Management (ESM).
Thermal Group
10 User Security Group The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems. User Security Group Table The User Security Group defines objects in the User Security MIB table. User Security Table The following object sets up the User Security Table: Name userSecurityTable Object ID 1.3.6.1.4.1.674.10892.1.
User Security Chassis Index Name userSecuritychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.1 Description Defines the user security index (one-based) of this chassis. Syntax DellObjectRange Access Read-only User Security Index Name userSecurityIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.2 Description Defines the user security index. Syntax DellObjectRange Access Read-only User Security User Name Name userSecurityUserName Object ID 1.3.6.1.4.1.674.10892.1.800.1.
User Security Request Name Name userSecurityRequestName Object ID 1.3.6.1.4.1.674.10892.1.800.1.5 Description Defines a request name used for creating, deleting, and editing users.
User Security Group
Remote Flash BIOS Group 11 The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates on the system. Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table. Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table: Name remoteFlashBIOSTable Object ID 1.3.6.1.4.1.674.10892.1.900.
Remote Flash BIOS Chassis Index Name remoteFlashBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system.
Remote Flash BIOS Status Name remoteFlashBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.5 Description Defines the status of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateStatus Access Read-only Remote Flash BIOS Last BIOS Date Name Name remoteFlashBIOSLastBIOSDateName Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.6 Description Defines the date of the last BIOS update.
Remote Flash BIOS Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 11-1. Remote Flash BIOS State Capabilities Unique Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The remote flash BIOS’s capabilities are unknown. enableCapable(2) The remote flash BIOS can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
Table 11-3. Remote Flash BIOS Completion Code Variable Name: DellRemoteFlashBIOSCompletionCode Data Type: Integer Possible Data Values Meaning of Data Value completionCodeIsOther(1) The completion code status is not one of the following: completionCodeIsUnknown(2) The completion code is unknown (not known or not monitored). completionCodeIsOK(3) This completion code completed successfully. completionCodeIsBadImage(4) This completion code is a bad flash BIOS image.
Remote Flash BIOS Group
12 Port Group The Port Group provides information about the different types of ports that may be present in your system. This management information base (MIB) group also provides information about the capabilities, states, and settings that are possible for each port.
Pointing Port Table Entry Name pointingPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1 Description Defines the Pointing Port Table entry. Syntax PointingPortTableEntry Access Not accessible Index pointingPortchassisIndex, pointingPortIndex Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis.
Pointing Port State Settings Name pointingPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.10.4 Description Defines the state and settings of the pointing port. Syntax DellStateSettings Access Read-write Pointing Port Status Name pointingPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.10.5 Description Defines the status of the pointing port. Syntax DellStatus Access Read-only Pointing Port Security State Name pointingPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.
Pointing Port Name Name pointingPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.10.8 Description Defines the name of the pointing port. Syntax DellString Access Read-only Pointing Port BIOS Connector Type Name pointingPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.9 Description Defines the basic input/output system (BIOS) connector type of the pointing port. Syntax DellGenericPortConnectorType Access Read-only Keyboard Port Table Name keyboardPortTable Object ID 1.3.
Keyboard Port Chassis Index Name keyboardPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Keyboard Port Index Name keyboardPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.2 Description Defines the index of the keyboard ports in this chassis. Syntax DellObjectRange Access Read-only Keyboard Port State Capabilities Name keyboardPortStateCapabilities Object ID 1.3.6.1.4.
Keyboard Port Status Name keyboardPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.5 Description Defines the status of the keyboard port. Syntax DellStatus Access Read-only Keyboard Port Security State Name keyboardPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.6 Description Defines the security settings of the keyboard port. Syntax DellPortSecurityState Access Read-only Keyboard Port Connector Type Name keyboardPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.
Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Name processorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.30 Description Defines the Processor Port Table.
Processor Port Index Name processorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2 Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port.
Processor Port Security State Name processorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.6 Description Defines the security settings of the processor port. Syntax DellPortSecurityState Access Read-only Processor Port Connector Type Name processorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.7 Description Defines the connector type of the processor port. Syntax DellProcessorPortConnectorType (See Table 12-3.
Memory Device Port Table Name memoryDevicePortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.40 Description Defines the Memory Device Port Table. Syntax IntegerMemoryDevicePortTableEntry Access Not accessible Memory Device Port Table Entry Name memoryDevicePortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1 Description Defines the Memory Device Port Table entry.
Memory Device Port State Capabilities Name memoryDevicePortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.3 Description Defines the capabilities of the memory device port. Syntax DellStateCapabilities Access Read-only Memory Device Port State Settings Name memoryDevicePortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.4 Description Defines the state and settings of the memory device port.
Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7 Description Defines the connector type of the memory device port. Syntax DellMemoryDevicePortConnectorType (See Table 12-4.) Access Read-only Memory Device Port Name Name memoryDevicePortName Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.8 Description Defines the name of the memory device port.
Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any). Syntax DellUnsigned32BitRange Access Read-only Monitor Port Table Name monitorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.
Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port. Syntax DellStateCapabilities Access Read-only Monitor Port State Settings Name monitorPortStateSettings Object ID 1.3.6.1.4.
Monitor Port Security State Name monitorPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.6 Description Defines the security settings of the monitor port. Syntax DellPortSecurityState Access Read-only Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port. Syntax DellMonitorPortConnectorTypes (See Table 12-5.
Small Computer System Interface (SCSI) Port Table Name sCSIPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.60 Description Defines the SCSI Port Table. Syntax IntegerSCSIPortTableEntry Access Not accessible SCSI Port Table Entry Name sCSIPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1 Description Defines the SCSI Port Table entry.
SCSI Port State Capabilities Name sCSIPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.3 Description Defines the capabilities of the SCSI port. Syntax DellStateCapabilities Access Read-only SCSI Port State Settings Name DellStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.4 Description Defines the state and settings of the SCSI port. Syntax DellStatus Access Read-write SCSI Port Status Name sCSIPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.
SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7 Description Defines the connector type of the SCSI port. Syntax DellSCSIPortConnectorType (See Table 12-6.) Access Read-only SCSI Port Name Name sCSIPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.8 Description Defines the name of the SCSI port. Syntax DellString Access Read-only SCSI Port BIOS Connector Type Name sCSIPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.
Parallel Port Table Entry Name parallelPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1 Description Defines the Parallel Port Table entry. Syntax ParallelPortTableEntry Access Not accessible Index parallelPortchassisIndex, parallelPortIndex Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.1 Description Defines the index (one-based) of this chassis.
Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-write Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5 Description Defines the status of the parallel port. Syntax DellStatus Access Read-only Parallel Port Security State Name DellPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.
Parallel Port Name Name parallelPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.8 Description Defines the name of the parallel port. Syntax DellString Access Read-only Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9 Description Defines the pinout of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Parallel Port Capabilities Unique Name parallelPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.
Parallel Port IRQ Level Name parallelPortIRQLevel Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.12 Description Defines the Interrupt Request Level (IRQ) of the parallel port. Syntax DellUnsigned8BitRange Access Read-only Parallel Port DMA Support Name parallelPortDMASupport Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.13 Description Defines if direct memory access (DMA) is supported by the parallel port.
Serial Port Chassis Index Name serialPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Serial Port Index Name serialPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.2 Description Defines the index of the serial ports in this chassis. Syntax DellObjectRange Access Read-only Serial Port State Capabilities Name serialPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.
Serial Port Status Name serialPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Security State Name serialPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.6 Description Defines the security settings of the serial port. Syntax DellPortSecurityState Access Read-only Serial Port Connector Type Name serialPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.
Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description Defines the maximum speed the serial interface can support in bits per second (bps). Syntax DellUnsigned32BitRange Access Read-only Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.10 Description Defines additional capabilities of the serial port.
Universal Serial Bus (USB) Port Table Name uSBPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.90 Description Defines the USB Port Table. Syntax IntegerUSBPortTableEntry Access Not accessible USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry. Syntax USBPortTableEntry Access Not accessible Index uSBPortchassisIndex, uSBPortIndex USB Port Chassis Index Name uSBPortchassisIndex Object ID 1.3.6.1.4.1.674.
USB Port State Capabilities Name uSBPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.3 Description Defines the capabilities of the USB port. Syntax DellStateCapabilities Access Read-only USB Port State Settings Name uSBPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4 Description Defines the state and settings of the USB port. Syntax DellStateSettings Access Read-write USB Port Status Name uSBPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.
USB Port Connector Type Name uSBPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.7 Description Defines the connector type of the USB port. Syntax DellUSBPortConnectorType Access Read-only USB Port Name Name uSBPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.8 Description Defines the name of the USB port. Syntax DellString Access Read-only USB Port BIOS Connector Type Name uSBPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.
Port Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 12-1. Pointing Port Connector Type Variable Name: DellPointingPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The pointing port connector type is not one of the following: connectorPortTypeIsUnknown(2) The pointing port connector type is unknown.
Table 12-2. Keyboard Port Connector Types Variable Name: DellKeyboardPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The keyboard port connector type is not one of the following: connectorPortTypeIsUnknown(2) The keyboard port connector type is unknown. connectorPortTypeIsMiniDIN(3) The keyboard port connector type is a mini DIN. connectorPortTypeIsMicroDIN(4) The keyboard port connector type is a MicroDIN.
Table 12-3. Processor Port Connector Types Variable Name: DellProcessorPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The processor port connector type is not one of the following: connectorPortTypeIsUnknown(2) The processor port connector type is unknown. connectorPortTypeIsDaughterdBoard(3) The processor port connector type is a daughter board.
Table 12-4. Memory Device Port Connector Types Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsOther(1) The memory device port connector type is not one of the following: connectorPortTypeIsUnknown(2) The memory device port connector type is unknown. connectorPortTypeIsSIMM(3) The memory device port connector type is a single in-line memory module (SIMM).
Table 12-4. Memory Device Port Connector Types (continued) Variable Name: DellMemoryDevicePortConnectorType Data Type: Integer Possible Data Value Meaning of Data Value connectorPortTypeIsRIMM(12) The memory device port connector type is a Rambus Inline Memory Module (RIMM). connectorPortTypeIsSODIMM(13) The memory device port connector type is a small outline, dual in-line memory module (SODIMM). connectorPortTypeIsSRIMM(14) The memory device port connector type is a SRIMM. Table 12-5.
Table 12-6. SCSI Port Connector Types Variable Name: DellSCSIPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The SCSI port connector type is not one of the following: connectorPortTypeIsUnknown(2) The SCSI port connector type is unknown. connectorPortTypeIsDIN25pin(3) The SCSI port connector type is a DIN 25-pin. connectorPortTypeIsDIN50pin(4) The SCSI port connector type is a DIN 50-pin.
Device Group 13 The Device Group provides information about different types of pointing, keyboard, processor, cache, memory, and peripheral component interconnect (PCI) devices. Variables in this group cover information about type, settings, configuration, manufacturer, address or location, and if applicable, the speed of the device.
Pointing Device Table Name pointingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.10 Description Defines the Pointing Device Table. This group of objects references the Pointing Port Index (See Section 12). Syntax SEQUENCE OF PointingDeviceTableEntry Access Not accessible Pointing Device Table Entry Name pointingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1 Description Defines the Pointing Device Table entry.
Pointing Device State Capabilities Name pointingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.3 Description Defines the capabilities of the pointing device. Syntax DellStateCapabilities Access Read-only Pointing Device State Settings Name pointingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.4 Description Defines the state of the pointing device.
Pointing Device Type Name pointingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.7 Description Defines the type of the pointing device. Syntax DellPointingDeviceType (See Table 13-1.) Access Read-only Pointing Device Number of Buttons Name pointingDeviceNumberofButtons Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.8 Description Defines the number of buttons on the pointing device.
Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Keyboard Device Index Name keyboardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2 Description Defines the index of the keyboard device for this chassis.
Keyboard Device Status Name keyboardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.5 Description Defines the status of the keyboard device. Syntax DellStatus Access Read-only Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis. Syntax DellStatus Access Read-only Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1.3.6.1.4.1.
Processor Device Table Name processorDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.30 Description Defines the Processor Device Table. Syntax SEQUENCE OF ProcessorDeviceTableEntry Access Not accessible Processor Device Table Entry Name processorDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1 Description Defines the Processor Device Table entry.
Processor Device State Capabilities Name processorDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.3 Description Defines the capabilities of the processor device. Syntax DellStateCapabilities Access Read-only Processor Device State Settings Name processorDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.4 Description Defines the state of the processor device.
Processor Device Type Name processorDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7 Description Defines the type of processor device. Syntax DellProcessorDeviceType (See Table 13-4) Access Read-only Processor Device Manufacturer Name Name processorDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.8 Description Defines the name of manufacturer of the processor device.
Processor Device Maximum Speed Name processorDeviceMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.11 Description Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.12 Description Defines the current speed of the processor device in MHz.
Processor Device Voltage Name processorDeviceVoltage Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.14 Description Defines the voltage powering the processor device in millivolts. A zero (0) indicates the speed is unknown. Syntax DellSigned32BitRange Access Read-only Processor Device Upgrade Information Name processorDeviceUpgradeInformation Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.15 Description Defines the processor upgrade information for the processor device.
Processor Device Core Count Name processorDeviceCoreCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17 Description Defines the number of processor cores detected for the processor device. Syntax DellUnsigned32BitRange Access Read-only Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.18 Description Defines the number of processor cores enabled for the processor device.
Processor Device Characteristics Name processorDeviceCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.20 Description This attribute defines characteristics of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one). NOTE: Bits 2-15 need to be examined in the context of bit 1. If bit 1 is set, the processor characteristics are unknown and bits 2-15 cannot be used to determine if the functions associated with the bits are supported.
Processor Device Extended Settings Name processorDeviceExtendedSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.22 Description This attribute defines extended settings of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Processor Device Stepping Name Name processorDeviceSteppingName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.25 Description Defines the stepping of the processor device. Syntax DellString Access Read-only Processor Device Status Table Name processorDeviceStatusTable Object ID 1.3.6.1.4.1.674.10892.1.1100.32 Description Defines the Processor Device Status Table.
Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe. Syntax DellObjectRange Access Read-only Processor Device Status State Capabilities Name processorDeviceStatusStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3 Description Defines the state capabilities of the processor device status probe.
Processor Device Status Reading Name processorDeviceStatusReading Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.6 Description Defines the reading of the processor device status probe. Syntax DellProcessorDeviceStatusReading Access Read-only Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe.
Cache Device Table Entry Name cacheDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1 Description Defines the Cache Device Table entry. Syntax CacheDeviceTableEntry Access Not accessible Index cacheDevicechassisIndex, cacheDeviceIndex Cache Device Chassis Index Name cacheDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.1 Description Defines the index (one-based) of this chassis.
Cache Device State Settings Name cacheDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.4 Description Defines the state of the cache device. Syntax DellStateSettings Access Read-write Cache Device Status Name cacheDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.5 Description Defines the status of the cache device. Syntax DellStatus Access Read-only Cache Device Processor Device Index Reference Name cacheDeviceprocessorDeviceIndexReference Object ID 1.3.6.1.4.1.
Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Table 13-13.) Access Read-only Cache Device Status State Name cacheDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.9 Description Defines the status state of the cache device. Syntax DellCacheDeviceStatusState (See Table 13-10.
Cache Device Maximum Size Name cacheDeviceMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.12 Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Defines the current size of the cache device in KB. A zero (0) indicates that the size is unknown.
Cache Device Is Socketed Name cacheDeviceIsSocketed Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.16 Description Defines if the cache device is socketed. Syntax DellBoolean Access Read-only Cache Device Error Checking and Correction (ECC) Type Name cacheDeviceECCType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.17 Description Defines the type of error correction in use by the cache device. Syntax DellCacheDeviceECCType (See Table 13-11.
Cache Device Current Type Name cacheDeviceCurrentType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.20 Description Defines the current type of SRAM for the cache device. Syntax DellCacheDeviceSRAMType (See Table 13-14.) Access Read-only Memory Device Table Name memoryDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.50 Description Defines the Memory Device Table.
Memory Device Index Name memoryDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.2 Description Defines the index of the memory device in this chassis. Syntax DellObjectRange Access Read-only Memory Device State Capabilities Name memoryDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.3 Description Defines the capabilities of the memory device. Syntax DellStateCapabilities Access Read-only Memory Device State Settings Name memoryDeviceStateSettings Object ID 1.
Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-only Memory Device Type Name memoryDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7 Description Defines the type of the memory device. Syntax DellMemoryDeviceType (See Table 13-16.
Memory Device Error Count NOTE: Memory Device Failure Modes has now replaced this attribute. Memory Device Error Count should no longer be used. If you use the Memory Device Error Count attribute, the value returned is always zero, and using the attribute will have no effect. Name memoryDeviceErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.9 Description Defines the total number of Error Checking and Correction (ECC) errors detected by the memory device.
Memory Device Form Factor Name memoryDeviceFormFactor Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.12 Description Defines the form factor of the memory device. Syntax DellMemoryDeviceFormFactor (See Table 13-15.) Access Read-only Memory Device Set Name memoryDeviceSet Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.13 Description Defines if the memory device is a part of a set. A zero (0) indicates that this device is not part of a set.
Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16 Description Defines the total number of bits, including ECC, used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Memory Device Total Data Bus Width Name memoryDeviceTotalDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.17 Description Defines the total number of data bits used by the memory device.
Memory Device Uncorrectable Memory Event Count NOTE: Memory Device Failure Modes has now replaced this attribute. Memory Device Uncorrectable Memory Event Count should no longer be used. If you use the Memory Device Uncorrectable Memory Event Count attribute, the value returned is always zero, and using the attribute will have no effect. Name memoryDeviceMultiBitErrorCount Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
Memory Device Part Number Name Name memoryDevicePartNumberName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.22 Description Defines the manufacturer's part number for the memory device. Syntax DellString Access Read-only Memory Device Serial Number Name Name memoryDeviceSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.23 Description Defines the serial number of the memory device.
Memory Device Mapped Address Table Name memoryDeviceMappedAddressTable Object ID 1.3.6.1.4.1.674.10892.1.1100.60 Description Defines the Memory Device Mapped Address Table. Syntax SEQUENCE OF MemoryDeviceMappedAddressTableEntry Access Not accessible Memory Device Mapped Address Table Entry Name memoryDeviceMappedAddressTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1 Description Defines the Memory Device Mapped Address Table entry.
Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.2 Description Defines the index (one-based) of the memory device mapped address in this chassis. Syntax DellObjectRange Access Read-only Memory Device Mapped Address State Capabilities Name memoryDeviceMappedAddressStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.3 Description Defines the capabilities of the memory device mapped address.
Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address. Syntax DellObjectRange Access Read-only Memory Device Mapped Address Row Position Name memoryDeviceMappedAddressRowPosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.7 Description Defines the position of the referenced memory in a row of the memory device mapped address.
Memory Device Mapped Address Interleave Depth Name memoryDeviceMappedAddressInterleaveDepth Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.9 Description Defines the maximum number of consecutive rows from the referenced memory device that are accessed in a single interleaved transfer in the memory device mapped address. Syntax DellUnsigned32BitRange Access Read-only Memory Device Mapped Address Starting Address Name memoryDeviceMappedAddressStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.
Generic Device Table Entry Name genericDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1 Description Defines the Generic Device Table entry. Syntax GenericDeviceTableEntry Access Not accessible Index genericDevicechassisIndex, genericDeviceIndex Generic Device Chassis Index Name genericDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1 Description Defines the index (one-based) of this chassis.
Generic Device State Settings Name genericDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.4 Description Defines the state of the generic device. Syntax DellStateSettings Access Read-write Generic Device Status Name genericDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.5 Description Defines the status of the generic device. Syntax DellStatus Access Read-only Generic Device System Slot Index Reference Name genericDeviceSystemSlotIndexReference Object ID 1.3.6.
Generic Device Name Name genericDeviceName Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8 Description Defines the name of the generic device. Syntax DellString Access Read-only PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Description Defines the PCI Device Detail Table. Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.80.
PCI Device Index Name pCIDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.2 Description Defines the index (one-based) of the PCI device in this chassis. Syntax DellObjectRange Access Read-only PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3 Description Defines the capabilities of the PCI device. Syntax DellStateCapabilities Access Read-only PCI Device State Settings Name pCIDeviceStateSettings Object ID 1.3.6.1.4.1.
PCI Device System Slot Index Reference Name pCIDeviceSystemSlotIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.6 Description Defines the index number of the system slot that this PCI device is in. Syntax DellObjectRange Access Read-only PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.7 Description Defines the bus width of the PCI device in this chassis.
PCI Device Speed Name pCIDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.10 Description Defines the bus speed in MHz of the PCI device in this chassis. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only PCI Device Adapter Fault Name pCIDeviceAdapterFault Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.11 Description Defines whether the PCI device in this chassis has detected a fault.
PCI Device Configuration Space Chassis Index Name pCIDeviceConfigurationSpacechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only PCI Device Configuration Space Index Name pCIDeviceConfigurationSpaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.2 Description Defines the index (one-based) of the PCI device configuration in this chassis.
PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration. Syntax DellStatus Access Read-only PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6 Description Defines the index number of PCI device that this configuration applies to.
PCI Device Configuration Space Function Number Name pCIDeviceConfigurationSpaceFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.9 Description Defines the function number of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only PCI Device Configuration Space Header Name pCIDeviceConfigurationSpaceHeader Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.10 Description Defines the common configuration space header of the PCI device. Syntax OCTET STRING (SIZE(0..
Network Device Chassis Index Name networkDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.1 Description Defines the index (one-based) of the chassis that contains the network device. Syntax DellObjectRange Access Read-only Network Device Index Name networkDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2 Description Defines the index (one-based) of the network device.
Network Device Description Name Name networkDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.5 Description Defines the description of the network device. Syntax DellString Access Read-only Network Device Product Name Name networkDeviceProductName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.6 Description Defines the product name of the network device. Syntax DellString Access Read-only Network Device Vendor Name Name networkDeviceVendorName Object ID 1.3.6.1.4.1.674.
Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.9 Description Defines the path to the binary image of the driver for the network device. Syntax DellString Access Read-only Network Device Driver Version Name Name networkDeviceDriverVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.10 Description Defines the version of the driver for the network device.
Network Device Default Gateway IP Address Name networkDeviceDefaultGatewayIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.13 Description Defines the IP address of the default gateway for the network device. Syntax IpAddress Access Read-only Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Network Device PCI Bus Number Name networkDevicePCIBusNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.17 Description Defines the PCI bus number of the network device. Syntax DellUnsigned8BitRange Access Read-only Network Device PCI Device Number Name networkDevicePCIDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18 Description Defines the PCI device number of the network device.
Network Device Base IO Port Address Name networkDeviceBaseIOPortAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.21 Description Defines the base input/outport port address of the network device. Syntax DellUnsigned32BitRange Access Read-only Network Device Teaming Flags Name networkDeviceTeamingFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.22 Description Defines the teaming features of the network device.
Network Device RDMA Capability Flags Name networkDeviceRDMACapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25 Description Defines the Remote Direct Memory Access (RDMA) capability flags of the network device. Syntax DellNetworkDeviceRDMACapabilityFlags (see Table 13-23) Access Read-only Network Device RDMA Enabled Name networkDeviceRDMAEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.26 Description Defines if RDMA is enabled for the network device.
Managed System Services Device Table Name managedSystemServicesDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.100 Description Defines the Managed System Services Device Table. Syntax SEQUENCE OF ManagedSystemServicesDeviceTableEntry Access Not accessible Managed System Services Device Table Entry Name managedSystemServicesDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1 Description Defines the Managed System Services Device Table Entry.
Managed System Services Device Index Name managedSystemServicesDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.2 Description Defines the index (one-based) of the managed system services device. Syntax DellObjectRange Access Read-only Managed System Services Device Status Name managedSystemServicesDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.3 Description Defines the status of the managed system services device.
Managed System Services Device Storage Present Name managedSystemServicesDeviceStoragePresent Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.5 Description Defines whether storage is present on the managed system services device. Syntax DellBoolean Access Read-only Managed System Services Device Storage Size Name managedSystemServicesDeviceStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.
Name sdCardUnitTableEntry Index sdCardUnitChassisIndex, sdCardUnitIndex SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card unit. Syntax DellObjectRange Access Read-only SD Card Unit Index Name sdCardUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.2 Description Defines the index (one-based) of the SD Card unit.
Name sdCardUnitStateSettings Description Defines the state settings of the SD Card unit. Syntax DellStateSettings Access Read-only SD Card Unit Redundancy Status Name sdCardUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.5 Description Defines the redundancy status of the SD Card unit. Syntax DellStatusRedundancy Access Read-only SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.
SD Card Unit Status Name sdCardUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.8 Description Defines the status of the SD Card unit. Syntax DellStatus Access Read-only SD Card Device Table Name sdCardDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.112 Description Defines the SD Card Device Table. Syntax SEQUENCE OF SdCardDeviceTableEntry Access Not accessible SD Card Device Table Entry Name sdCardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.112.
Name sdCardDeviceChassisIndex Access Read-only SD Card Device Index Name sdCardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.2 Description Defines the index (one-based) of the SD Card device. Syntax DellObjectRange Access Read-only SD Card Device Status Name sdCardDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.3 Description Defines the status of the SD Card device. Syntax DellStatus Access Read-only SD Card Device Type Name sdCardDeviceType Object ID 1.3.6.1.
Name sdCardDeviceConfigCapabilities Access Read-only SD Card Device Config Settings Name sdCardDeviceConfigSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6 Description Defines the configuration settings of the SD Card device. Syntax DellSDCardDeviceConfigSettings Access Read-only SD Card Device Location Name Name sdCardDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.7 Description Defines the location of the SD Card device.
Name sdCardDeviceCardState Access Read-only SD Card Device Card Storage Size Name sdCardDeviceCardStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.10 Description Defines the storage size in MB (megabytes) of the SD card for the SD Card device. Syntax DellUnsigned32BitRange Access Read-only SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.
Table 13-1. Pointing Device Type (continued) Variable Name: DellPointingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsATrackBall(4) Device type is a track ball. deviceTypeIsATrackPoint(5) Device type is a track point. deviceTypeIsAGlidePoint(6) Device type is a glide point. deviceTypeIsATouchPad(7) Device type is a touch pad. Table 13-2.
Table 13-3. Processor Device Status Reading (continued) Variable Name: DellProcessorDeviceStatusReading Data Type: Integer NOTE: These values are bit masks, so combination values are possible.
Table 13-5. Processor Upgrade Information Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsOther(1) The upgrade device type is not one of the following: processorUpgradeIsUnknown(2) Upgrade device type is unknown. processorUpgradeIsByDaughterBoard(3) Upgrade device is on a daughter board. processorUpgradeIsByZIFSocket(4) Upgrade device is in a zero insertion force (ZIF) socket.
Table 13-5. Processor Upgrade Information (continued) Variable Name: DellProcessorUpgradeInformation Data Type: Integer Possible Data Values Meaning of Data Value processorUpgradeIsBySocket939(18) Upgrade is by Socket 939. processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket mPGA604. processorUpgradeIsBySocketLGA771(20) Upgrade is by Socket LGA771. processorUpgradeIsBySocketLGA775(21) Upgrade is by Socket LGA775. processorUpgradeIsBySocketS1(22) Upgrade is by Socket S1.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIs80287(8) The processor family is 80287. deviceFamilyIs80387(9) The processor family is 80387. deviceFamilyIs80487(10) The processor family is 80487. deviceFamilyIsPentium(11) The processor family is Intel® Pentium®. deviceFamilyIsPentiumPro(12) The processor family is Pentium Pro.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDAthlon(29) The processor family is AMD™ Athlon™. deviceFamilyIsAMD2900(30) The processor family is AMD2900. deviceFamilyIsK6-2Plus(31) The processor family is K6-2+. deviceFamilyIsPowerPC(32) The processor family is Power PC. deviceFamilyIsPowerPC601(33) The processor family is Power PC 601.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAlpha21364(55) The processor family is Alpha 21364. deviceFamilyIsAMDTurionIIUltra DualMobileM(56) The processor family is AMD Turion(TM) II Ultra Dual-Core Mobile M Processor Family. deviceFamilyIsAMDTurionIIDualM obileM(57) The processor family is AMD Turion(TM) II Dual-Core Mobile M Processor Family.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsUltraSPARCIIIi (88) The processor family is UltraSPARC IIIi. deviceFamilyIs68040(96) The processor family is 68040 Family. deviceFamilyIs68xxx(97) The processor family is 68xxx. deviceFamilyIs68000(98) The processor family is 68000. deviceFamilyIs68010(99) The processor family is 68010.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsQuadCoreAMDOpter on(138) The processor family is Quad-Core AMD Opteron. deviceFamilyIsThirdGenerationA The processor family is third-generation MDOpteron(139) AMD Opteron. deviceFamilyIsAMDPhenomFXQuadC ore(140) The processor family is AMD Phenom™ FX Quad-Core.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelXeo n5100(164) The processor family is Dual-Core Intel Xeon processor 5100 Series. deviceFamilyIsDualCoreIntelXeo n5000(165) The processor family is Dual-Core Intel Xeon processor 5000 Series. deviceFamilyIsDualCoreIntelXeo nLV(166) The processor family is Dual-Core Intel Xeon processor LV.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsAMDAthlonXP(182) The processor family is AMD Athlon XP. deviceFamilyIsAMDAthlonMP(183) The processor family is AMD Athlon MP. deviceFamilyIsAMDDuron(184) The processor family is AMD Duron™. deviceFamilyIsIntelPentiumM(185) The processor family is Intel Pentium M.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsDualCoreIntelCel eron(199) The processor family is Dual-Core Intel Celeron Processor. deviceFamilyIsIBM390(200) The processor family is IBM390. deviceFamilyIsG4(201) The processor family is G4. deviceFamilyIsG5(202) The processor family is G5. deviceFamilyIsESA390G6(203) The processor family is ESA/390 G6.
Table 13-6. Processor Device Family (continued) Variable Name: DellProcessorDeviceFamily Data Type: Integer Possible Data Values Meaning of Data Value deviceFamilyIsQuadCoreIntelXeo n7xxx(222) The processor family is Quad-Core Intel Xeon processor 7xxx Series. deviceFamilyIsMultiCoreIntelXe on7xxx(223) The processor family is Multi-Core Intel Xeon processor 7xxx Series. deviceFamilyIsEmbeddedAMDOpert onQuadCore(230) The processor family is Embedded AMD Opteron Quad-Core.
Table 13-7. Cache Device Type Variable Name: DellCacheDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) System cache type is not one of the following: deviceTypeIsUnknown(2) System cache type is unknown. deviceTypeIsInstruction(3) System cache type is instruction. deviceTypeIsData(4) System cache type is data. deviceTypeIsUnified(5) System cache type is both instruction and data. Table 13-8.
Table 13-9. Cache Device Write Policy Variable Name: DellCacheDeviceWritePolicy Data Type: Integer Possible Data Values Meaning of Data Value deviceWritePolicyIsOther(1) Device write policy is not one of the following: deviceWritePolicyIsUnknown(2) Device write policy is unknown. deviceWritePolicyIsWriteBack(3) Device write policy is write back. deviceWritePolicyIsWriteThrough(4) Device write policy is write through. deviceWritePolicyIsVariesByAddress(5) Device write policy varies by address.
Table 13-11. Cache Device ECC Type Variable Name: DellPointingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsOther(1) Device type is not one of the following: deviceTypeIsUnknown(2) Device type is unknown. deviceTypeIsAMouse(3) Device type is a mouse. deviceTypeIsATrackBall(4) Device type is a track ball. deviceTypeIsATrackPoint(5) Device type is a track point. deviceTypeIsAGlidePoint(6) Device type is a glide point.
Table 13-12. Cache Device Associativity (continued) Variable Name: DellCacheDeviceAssociativity Data Type: Integer Possible Data Values Meaning of Data Value deviceAssociativityIsSixteenWaySet Associative(8) Device is sixteen-way set associative. deviceAssociativityIs12WaySetAssoc iative(9) Device is 12-way Set-Associative. deviceAssociativityIs24WaySetAssoc iative(10) Device is 24-way Set-Associative. deviceAssociativityIs32WaySetAssoc iative(11) Device is 32-way Set-Associative.
Table 13-14. Cache Device Static Random-Access Memory (SRAM) Type Variable Name: DellCacheDeviceSRAMType Data Type: Integer Possible Data Values Meaning of Data Value deviceSRAMTypeIsOther(1) Device SRAM type is not one of the following: deviceSRAMTypeIsUnknown(2) Device SRAM type is unknown. deviceSRAMTypeIsNonBurst(3) Device SRAM type is nonburst. deviceSRAMTypeIsBurst(4) Device SRAM type is burst. deviceSRAMTypeIsPipeBurst(5) Device SRAM type is pipeburst.
Table 13-15. Memory Device Type Form Factor (continued) Variable Name: DellMemoryDeviceFormFactor Data Type: Integer Possible Data Values Meaning of Data Value deviceFormFactorIsARowOfChips(11) Device form factor is a row of chips. deviceFormFactorIsRIMM(12) Device form factor is RIMM. deviceFormFactorIsSODIMM(13) Device form factor is SODIMM. deviceFormFactorIsSRIMM(14) Device form factor is SRIMM. deviceFormFactorIsFBDIMM(15) Device form factor is FB-DIMM. Table 13-16.
Table 13-16. Memory Device Type (continued) Variable Name: DellMemoryDeviceType Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeIsSDRAM(15) Device type is SDRAM. deviceTypeIsSGRAM(16) Device type is SGRAM. deviceTypeIsRDRAM(17) Device type is RDRAM. deviceTypeIsDDR(18) Device type is DDR. deviceTypeIsDDR2(19) Device type is DDR2. deviceTypeIsDDR2FBDIMM(20) Device type is DDR2 FB-DIMM. deviceTypeIsDDR3(24) Device type is DDR3. deviceTypeIsFBD2(25) Device type is FBD2.
Table 13-17. Memory Device Type Details (continued) Variable Name: DellMemoryDeviceTypeDetails Data Type: Integer Possible Data Values Meaning of Data Value deviceTypeDetailIsCMOS(8) The detailed device type is CMOS. deviceTypeDetailIsEDO(9) The detailed device type is EDO. deviceTypeDetailIsWindowDRAM(10) The detailed device type is "Window" DRAM. deviceTypeDetailIsCacheDRAM(11) The detailed device type is Cache DRAM. deviceTypeDetailIsNonVolatile(12) The detailed device type is Non-volatile.
Table 13-19. Memory Device Failure Modes Variable Name: DellMemoryDeviceFailureModes Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value (0) Memory device has no faults. eccSingleBitCorrectionWarningRate(1) Memory device has exceeded the Correctable Memory Event warning rate. eccSingleBitCorrectionFailureRate(2) Memory device has exceeded the Correctable Memory Event failure rate.
Table 13-20. Network Device Connection Status Variable Name: DellNetworkDeviceConnectionStatus Data Type: Integer Possible Data Values Meaning of Data Value disconnected(2) Media reports that device is disconnected. driverBad(3) Driver cannot be opened to determine status. driverDisabled(4) Driver is disabled. hardwareInitalizing(10) Hardware is initializing. hardwareResetting(11) Hardware is resetting. hardwareClosing(12) Hardware is closing down. hardwareNotReady(13) Hardware is not ready.
Table 13-22. Network Device TOE Capability Flags Variable Name: DellNetworkDeviceTOECapabilityFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value unknown(1) Querying for TOE capability is supported but query returned an error. available(2) Device has TOE capability. notAvailable(4) Device does not have TOE capability. cannotBeDetermined(8) Querying for TOE capability is supported but an error prevented querying.
Table 13-24. Network Device iSCSI Capability Flags Variable Name: DellNetworkDeviceiSCSICapabilityFlags Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for iSCSI capability is not supported. unknown(1) Querying for iSCSI capability is supported but query returned an error. available(2) Device has iSCSI capability. notAvailable(4) Device does not have iSCSI capability.
Table 13-25. Managed System Services Device Type Variable Name: DellManagedSystemServicesDeviceType Data Type: Integer Possible Data Values Meaning of Data Value baseDevice(0) Device type is base device. optionalDevice(1) Device type is optional device. Table 13-26. SD Card Device Type Variable Name: DellSDCardDeviceType Data Type: Integer Possible Data Values Meaning of Data Value other(1) Device type is other. unknown(2) Device type is unknown. hypervisor(3) Device type is Hypervisor.
Table 13-28. SD Card Device Config Settings Variable Name: DellSDCardDeviceConfigSettings Data Type: Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) SD card device has none of the following settings. sdEnabled(1) SD media is enabled. vFlashEnabled(2) Virtual Flash (vFlash) is enabled. Table 13-29.
Slot Group 14 The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots. System Slot Group Table The System Slot Group defines objects in the System Slot MIB table. System Slot Table The following object sets up the System Slot Table: Name systemSlotTable Object ID 1.3.6.1.4.1.674.10892.1.1200.
System Slot Chassis Index Name systemSlotchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis.
System Slot Status Name systemSlotStatus Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.5 Description Defines the status of the system slot. Syntax DellStatus Access Read-only System Slot Current Usage Name systemSlotCurrentUsage Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.6 Description Defines the current usage of the system slot. Syntax DellStatus Access Read-only System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.
System Slot Length Name systemSlotLength Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.9 Description Defines the length of the system slot. Syntax DellSystemSlotLength (See Table 14-5.) Access Read-only System Slot Slot ID Name systemSlotSlotID Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.10 Description Defines the slot identification number of the system slot. A zero (0) indicates that the slot is embedded on the motherboard.
System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13 Description Defines the slot speed in megahertz of the hot-plug system slot. A zero (0) indicates that the slot speed is unknown. Syntax DellUnsigned32BitRange Access Read-only System Slot Hot-Plug Adapter Speed Name systemSlotHotPlugAdapterSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.14 Description Defines the adapter speed in megahertz of the hot-plug system slot.
Table 14-1. System Slot State Capabilities (continued) Variable Name: DellSystemSlotStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugCanSignal The system slot attention state Attention(8) (and corresponding LED) can be set. systemSlotHotPlugCanSignal Power on fault (and corresponding LED) can PowerFault(16) be detected due to a short or overcurrent.
Table 14-2. System Slot State Settings Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotHotPlugIsUnknown(1) The system slot’s capabilities are unknown. systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug. systemSlotHotPlugIsPoweredOn(4) The system slot power (and corresponding LED) can be powered on. systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) can be set.
Table 14-2. System Slot State Settings (continued) Variable Name: DellSystemSlotStateSettings Data Type: Integer Possible Data Values Meaning of Data Value systemSlotSupportsCard16(1024) The system slot supports PC Card-16. systemSlotSupportsCardBus(2048) The system slot supports CardBus. systemSlotSupportsZoomVideo(4096) The system slot supports zoom video. systemSlotSupportsModemRingResume The system slot supports modem (8192) ring resume.
Table 14-3. System Slot Type Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsOther(1) The system slot type is not one of following: systemSlotIsUnknown(2) The system slot type is unknown. systemSlotIsISA(3) The system slot is Industry Standard Architecture (ISA). systemSlotIsMCA(4) The system slot is Micro Channel Architecture (MCA). systemSlotIsEISA(5) The system slot is Extended Industry Standard Architecture (EISA).
Table 14-3. System Slot Type (continued) Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsPC98C20(18) The system slot is a PC-98/C20. systemSlotIsPC98C24(19) The system slot is a PC-98/C24. systemSlotIsPC98E(20) The system slot type is PC-98/E. systemSlotIsPC98LocalBus(21) The system slot type is a PC-98 local bus. systemSlotIsPC98Card(22) The system slot type is a PC-98 card. systemSlotIsPCIX(23) The system slot type is a PCIX card.
Table 14-3. System Slot Type (continued) Variable Name: DellSystemSlotType Data Type: Integer Possible Data Values Meaning of Data Value systemSlotIsPCIExpressGen2X4(174) The system slot type is PCI Express Gen 2 x4. systemSlotIsPCIExpressGen2X8(175) The system slot type is PCI Express Gen 2 x8. systemSlotIsPCIExpressGen2X16(176) The system slot type is PCI Express Gen 2 x16. Table 14-4.
Table 14-6. System Slot Category Variable Name: DellSystemSlotCategory Data Type: Integer Possible Data Values Meaning of Data Value systemSlotCategoryIsOther(1) The system slot category is not one of following: systemSlotCategoryIsUnknown(2) The system slot category is unknown. systemSlotCategoryIsBusConnector(3) The system slot is a bus connector. systemSlotCategoryIsPCMCIA(4) The system slot category is PCMCIA. systemSlotCategoryIsMotherboard(5) The system slot is a motherboard. Table 14-7.
Table 14-7. Hot-Plug Bus Width (continued) Variable Name: DellSystemSlotHotPlugBusWidth Data Type: Integer Possible Data Values Meaning of Data Value busWidthIs12xOrx12(12) The system slot bus width is 12x or x12. busWidthIs16xOrx16(13) The system slot bus width is 16x or x16. busWidthIs32xOrx32(14) The system slot bus width is 32x or x32. NOTE: System slot bus width of type "n bits" are for parallel buses such as PCI.
Slot Group
Memory Group 15 The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory.
The following object sets up the Physical Memory Array Table: Name physicalMemoryArrayTable Object ID 1.3.6.1.4.1.674.10892.1.1300.10 Description Defines the Physical Memory Array Table. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1 Description Defines the Physical Memory Array Table entry.
Physical Memory Array State Capabilities Name physicalMemoryArrayStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.3 Description Defines the capabilities of the physical memory array. Syntax DellStateCapabilities Access Read-only Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array.
Physical Memory Array Error Checking and Correcting (ECC) Type Name physicalMemoryArrayECCType Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.7 Description Defines the ECC type used by the physical memory array. Syntax DellPhysicalMemoryArrayECCType (See Table 15-2.) Access Read-only Physical Memory Array Location Name physicalMemoryArrayLocation Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.8 Description Defines the location of the physical memory array.
Physical Memory Array In Use Number Sockets Name physicalMemoryArrayInUseNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.11 Description Defines the total number of memory sockets in use by the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Physical Memory Array ECC Error Nonrecoverable Threshold Name physicalMemoryArrayECCErrorNonRecoverbeThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
Physical Memory Array Redundant Memory Unit Index Reference Name physicalMemoryArrayRedundantMemoryUnitIndex Reference Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.15 Description Defines the index to the associated Redundant Memory Unit in this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses.
Physical Memory Array Mapped Chassis Index Name physicalMemoryArrayMappedchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Physical Memory Array Mapped Index Name physicalMemoryArrayMappedIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.2 Description Defines the index (one-based) of the memory array mapped address in this chassis.
Physical Memory Array Mapped Status Name physicalMemoryArrayMappedStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.5 Description Defines the status of the memory array mapped address. Syntax DellStatus Access Read-only Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis.
Physical Memory Array Mapped Partition Width Name physicalMemoryArrayMappedPartitionWidth Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.9 Description Defines the number of memory devices that form a single row in the memory array mapped address. A zero (0) indicates that the number is unknown.
Physical Memory Configuration Chassis Index Name physicalMemoryConfigChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.1 Description Defines the index (one-based) of the chassis associated with the physical memory configuration. Syntax DellObjectRange Access Read-only Physical Memory Configuration Index Name physicalMemoryConfigIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.2 Description Defines the index (one-based) of the physical memory configuration.
Physical Memory Configuration Status Name physicalMemoryConfigStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5 Description Defines the status of the physical memory configuration. Syntax DellStatus Access Read-only Physical Memory Configuration Redundant Capabilities Name physicalMemoryConfigRedundantCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.6 Description Defines the redundant capabilities of the physical memory.
Physical Memory Logging Table Entry Name physicalMemoryLoggingTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1 Description Defines the Physical Memory Logging Table entry. Syntax PhysicalMemoryLoggingTableEntry Access Not accessible Index physicalMemoryLoggingChassisIndex, physicalMemoryLoggingIndex Physical Memory Logging Chassis Index Name physicalMemoryLoggingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.
Physical Memory Logging Settings Name physicalMemoryLoggingSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.4 Description Defines the settings of the physical memory logging. Syntax DellPhysicalMemoryLoggingSettings Access Read-write Physical Memory Logging Status Name physicalMemoryLoggingStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.5 Description Defines the status of the physical memory logging.
Redundant Memory Unit Table Entry Name redundantMemoryUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1 Description Defines the Redundant Memory Unit Table entry. Syntax RedundantMemoryUnitTableEntry Access Not accessible Index redundantMemoryUnitChassisIndex, redundantMemoryUnitIndex Redundant Memory Unit Chassis Index Name redundantMemoryUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.
Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit. Syntax DellStateSettings Access Read-write Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5 Description Defines the redundancy status of the redundant memory unit.
Physical Memory Card Table This table defines the name of the memory card, the total number of device slots present on the memory card, and the number of memory device slots in use on the memory card. The following objects set up the Physical Memory Card Table: Physical Memory Card Table Name physicalMemoryCardTable Object ID 1.3.6.1.4.1.674.10892.1.1300.60 Description Defines the Physical Memory Card Table.
Physical Memory Card Index Name physicalMemoryCardIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.2 Description Defines the index (one-based) of the Physical Memory Card. Syntax DellObjectRange Access Read-only Physical Memory Card State Capabilities Name physicalMemoryCardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.3 Description Defines the state capabilities of the Physical Memory Card.
Physical Memory Card Name Name physicalMemoryCardName Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.6 Description Defines the name of the Physical Memory Card. Syntax DellString Access Read-only Physical Memory Card Total Number Sockets Name physicalMemoryCardTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.7 Description Defines the total number of memory sockets available on the Physical Memory Card. 2,147,483,647 indicates an unknown number of sockets.
Physical Memory Card Physical Memory Array Index Reference Name physicalMemoryCardPhyMemArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.9 Description Defines the index (one-based) of the Physical Memory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with.
Table 15-1. Physical Memory Array Location (continued) Variable Name: DellPhysicalMemoryArrayLocation Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsPCMCIA(8) The memory array location is a Personal Computer Memory Card International Association (PCMCIA) option card. memoryArrayLocationIsProprietary(9) The memory array location is a proprietary option card. memoryArrayLocationIsNUBUS(10) The memory array location is a NuBus bus.
Table 15-2. Physical Memory Array ECC Type Definitions Variable Name: DellPhysicalMemoryArrayECCType Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayECCTypeIsOther(1) There is not one of the following: memoryArrayECCTypeIsUnknown(2) The memory array ECC type is unknown. memoryArrayECCTypeIsNone(3) The memory array ECC type is none. memoryArrayECCTypeIsParity(4) The memory array ECC type is parity.
Table 15-4. Physical Memory Configuration State Settings Variable Name: DellPhysicalMemoryConfigStateSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no state settings. unknown(1) State settings are unknown. enabled(2) Object is disabled (offline) 0, or enabled (online) 1. notReady(4) Object "not ready." redundantMemoryIsActive(8) Redundant memory is active (in use) enabledAndRedundantMemoryIsActive(10) Redundant memory is enabled and in use.
Table 15-6. Physical Memory Configuration Redundant Settings Variable Name: DellPhysicalMemoryConfigRedundantSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory settings enabled. unknown(1) Redundant settings are unknown. The following redundant settings are mutually exclusive: spareEnabled(2) Spare redundant memory feature is enabled. mirrorEnabled(4) Mirror redundant memory feature is enabled.
Table 15-8. Physical Memory Logging Settings Variable Name: DellPhysicalMemoryLoggingSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging settings enabled. unknown Capabilities(1) Logging capabilities are unknown. The logging settings are: enabled(2) 382 Memory Group Logging is disabled (0), or enabled (1).
BIOS Setup Control Group 16 Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature.
BIOS Setup Control Table Entry Name biosSetUpControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1 Description Defines the BIOS Control Device Table entry. Syntax BiosSetUpControlTableEntry Access Not accessible Index biosSetUpControlchassisIndex BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1 Description Defines the index (one-based) of this chassis.
BIOS Setup Control Pointing Device Control Status Name bSUCpointingDeviceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.4 Description Defines the status of the pointing device. Syntax DellStatus Access Read-only BIOS Setup Control Pointing Device Control Name Name bSUCpointingDeviceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.5 Description Defines the setup BIOS name of the pointing device.
BIOS Setup Control Numeric Lock Control Status Name bSUCnumLockControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.8 Description Defines the status of the numeric lock. Syntax DellStatus Access Read-only BIOS Setup Control Numeric Lock Control Name Name bSUCnumLockControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.9 Description Defines the setup BIOS name of the numeric lock.
BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.12 Description Defines the status of the processor serial number. Syntax DellStatus Access Read-only BIOS Setup Control Processor Serial Number Control Name Name bSUCprocessorSerialNumberControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.13 Description Defines the setup BIOS name of the processor serial number.
BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17 Description Defines the setup BIOS name of the speaker control.
BIOS Setup Control NIF Wakeup on LAN Control Status Name bSUCnIFwakeonLanControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.20 Description Defines the status of the NIF Wakeup on LAN. Syntax DellStatus Access Read-only BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN.
BIOS Setup Control Boot Sequence Control Status Name bSUCbootSequenceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.24 Description Defines the status of the boot sequence. Syntax DellStatus Access Read-only BIOS Setup Control Boot Sequence Control Name Name bSUCbootSequenceControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.25 Description Defines the control name of the boot sequence.
BIOS Setup Control Administrator Password Control Status Name bSUCadministratorPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.28 Description Defines the status for administrator password control. Syntax DellStatus Access Read-only BIOS Setup Control Administrator Password Verify Name Name bSUCadministratorPasswordVerifyName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.29 Description Defines the setup BIOS name for the current administrator password.
BIOS Setup Control User Password Control Settings Unique Name bSUCuserPasswordControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.32 Description Defines the control settings for user password control. Syntax DellBIOSPasswordControlSettingsUnique (See Table 16-9.) Access Read-write BIOS Setup Control User Password Control Status Name bSUCuserPasswordControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.33 Description Defines the status of the user password control.
BIOS Setup Control TPM Security Control Capabilities Name bSUCtpmSecurityControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.36 Description Defines the BIOS setup control capabilities of Trusted Platform Module (TPM) security. Syntax DellTPMSecurityControlCapabilities Access Read-only BIOS Setup Control TPM Security Control Setting Name bSUCtpmSecurityControlSetting Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table. Syntax SCSIControlTableEntry Access Not accessible SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1 Description Defines the SCSI Control Table entry.
SCSI Control Capabilities Name sCSIControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.3 Description Defines the capabilities of the SCSI controller. Syntax DellStateCapabilities Access Read-only SCSI Control Settings Name sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4 Description Defines the state of the SCSI controller. Syntax DellStateSettings Access Read-only SCSI Control Status Name sCSIControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.
Parallel Port Control Table Name parallelPortControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.30 Description Defines the Parallel Port Control Table. Syntax ParallelPortControlTableEntry Access Not accessible Parallel Port Control Table Entry Name parallelPortControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1 Description Defines the Parallel Port Control Table entry.
Parallel Port Control Capabilities Unique Name parallelPortControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.3 Description Defines the capabilities of the parallel port. Syntax DellParallelPortControlCapabilitiesUnique (See Table 16-12.) Access Read-only Parallel Port Control Settings Unique Name parallelPortControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.4 Description Defines the state of the parallel port.
Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7 Description Defines the mode capabilities of the parallel port. Syntax DellParallelPortControlModeCapabilitiesUnique (See Table 16-14.) Access Read-only Parallel Port Control Mode Settings Unique Name parallelPortControlModeSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.8 Description Defines the mode settings of the parallel port.
Name serialPortControlTableEntry Index serialPortControlchassisIndex, serialPortControlIndex Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Serial Port Control Index Name serialPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2 Description Defines the index (one-based) of the serial port in this chassis.
Name serialPortControlSettingsUnique Access Read-only Serial Port Control Status Name serialPortControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Serial Port Control Name Name serialPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6 Description Defines the setup BIOS name of the serial port.
Name usbControlTableEntry Syntax UsbControlTableEntry Access Not accessible Index usbControlchassisIndex, usbControlIndex USB Control Chassis Index Name usbControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access Read-only USB Control Index Name usbControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.2 Description Defines the index (one-based) of the USB in this chassis.
Name usbControlSettings Description Defines the control settings for the USB. Syntax DellStateSettings Access Read-only USB Control Status Name usbControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.5 Description Defines the status of the USB. Syntax DellStatus Access Read-only USB Control Name Name usbControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.6 Description Defines the setup BIOS name of the USB.
IDE Control Table Entry Name ideControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1 Description Defines the IDE Control Table entry. Syntax IdeControlTableEntry Access Not accessible Index ideControlchassisIndex, ideControlIndex IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis.
IDE Control Settings Unique Name ideControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.4 Description Defines the settings for the IDE controller. Syntax DellideControlCapabilitiesUnique (See Table 16-17.) Access Read-only IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.
Diskette Control Table Entry Name disketteControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1 Description Defines the Diskette Control Table entry. Syntax DellStatus Access Not accessible Index disketteControlchassisIndex, disketteControlIndex Diskette Control Chassis Index Name disketteControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.1 Description Defines the index (one-based) of this chassis.
Diskette Control Settings Unique Name disketteControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.4 Description Defines the control settings for the diskette controller. Syntax DellDisketteControlSettingsUnique Access Read-only Diskette Control Status Name disketteControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.5 Description Defines the status of the diskette controller.
Network Interface Control Table Entry Name networkInterfaceControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1 Description Defines the Network Interface Control Table entry. Syntax NetworkInterfaceControlTableEntry Access Not accessible Index networkInterfaceControlchassisIndex, networkInterfaceControlIndex Network Interface Control Chassis Index Name networkInterfaceControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.
Network Interface Control Capabilities Unique Name networkInterfaceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.3 Description Defines the capabilities of the NIC. Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Table 16-19.) Access Read-only Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.4 Description Defines the control settings for the NIC.
BIOS Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 16-1. Speaker Control Capabilities Unique Variable Name: DellSpeakerControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Speaker control capabilities are unknown. enableCapable(2) Setup BIOS can enable speaker control. lowCapable(4) Setup BIOS can set the speaker volume to low.
Table 16-3. Network Interface (NIF) Wakeup on LAN Capabilities Unique Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown. enableCapable(2) Setup BIOS is capable of enabling the NIF Wakeup on LAN. addInCardCapable(4) Setup BIOS is capable of enabling Wakeup on LAN by option card. onBoardCapable(8) Setup BIOS is capable of enabling Wakeup on LAN by integrated NIF.
Table 16-5. Boot Sequence Control Capabilities Unique Variable Name: DellBootSequenceControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value bootSequenceUnknown(1) Boot sequence capabilities are unknown. bootFromDisketteFirstCapable Setup BIOS can boot from a diskette (2) first. bootFromhardDriveFirstCapable Setup BIOS can boot from an IDE hard (4) drive first. bootFromDisketteORHardDrive Setup BIOS can boot from a diskette or FirstCapable(6) an IDE hard drive first.
Table 16-7. BIOS Password Control Capabilities Variable Name: DellBIOSPasswordControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value passwordControlCapabilitiesUn BIOS password capabilities are known(1) unknown. passwordControlEnableCapable (2) Setup BIOS is capable of enabling password changes. passwordControlJumperDisable Capable(4) Setup BIOS is capable of determining if password control can be jumper disabled.
Table 16-9. BIOS Password Control Settings Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) Setup BIOS password state is unknown. passwordControlEnabled(2) Setup BIOS has password changes enabled. passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 16-10.
Table 16-12. Parallel Port Control Capabilities Variable Name: DellParallelPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS parallel port capabilities are unknown. enableCapable(2) Setup BIOS can enable the parallel port. lpt1Capable(4) Setup BIOS can support parallel port 1. lpt1andEnableCapable(6) Setup BIOS has enabled parallel port 1. lpt2Capable(8) Setup BIOS can support parallel port 2.
Table 16-14. Parallel Port Control Mode Settings Variable Name: DellParallelPortControlModeSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Parallel port mode is unknown. atModeEnabled(2) Setup BIOS has set the parallel port to AT mode. ps2ModeEnabled(4) Setup BIOS has set the parallel port to Personal Systems/2 (PS/2) mode. ecpModeEnabled(8) Setup BIOS has set the parallel port to Extended Capabilities Port (ECP) mode.
Table 16-15. Serial Port Control Capabilities (continued) Variable Name: DellSerialPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value com1OrCom3CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable(86) COM1 and COM3 serial ports. com2OrCom4CapableAndAuto Setup BIOS has enabled autoconfiguration of ConfigCapable(106) COM2 and COM4 serial ports. allcomCapable(126) Setup BIOS is capable of enabling or autoconfiguring all serial ports. Table 16-16.
Table 16-17. IDE Control Capabilities Variable Name: DellideControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) IDE control capabilities are unknown. ideControlAutoConfigOrEnable IDE controller is autoconfigurable or Capable(2) enable capable. Table 16-18. Diskette Control Settings Variable Name: DellDisketteControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Diskette control state is unknown.
Table 16-20. Network Interface Control Settings Variable Name: DellNetworkInterfaceControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Network interface state is unknown. enabled(2) Network interface is enabled. enabledWithoutPXE(4) Network interface is enabled without PXE.
Local Response Agent Group 17 The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA). The LRA allows systems managers to predetermine how a system running the server administrator will respond to a particular event type, such as the loss of redundancy in a specific component or the elevation of temperature in a chassis. Systems managers can configure the LRA to respond to an event type with a specific action.
LRA Global Settings Table Name lRAGlobalSettingsTable Object ID 1.3.6.1.4.1.674.10892.1.1500.10 Description Defines the LRA Global Settings Table. Syntax SEQUENCE OF LRAGlobalSettingsTableEntry Access Not accessible LRA Global Settings Table Entry Name lRAGlobalSettingsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1 Description Defines the LRA Global Settings Table entry.
LRA Global Settings Disable Time-out Value Name lRAGlobalSettingsDisableTimeoutValue Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.3 Description Defines the time-out duration countdown, in seconds, that the LRA global settings will be disabled after a system shutdown and reboot. Syntax DellUnsigned32BitRange Access Read-only LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.
LRA Action Table The DellLocalResponseAgentCapabilitiesUnique variable in the global action table defines the capabilities that are allowed for a particular system. The LRA Action Table that follows selects which of the system’s capabilities (global actions) are to be enabled. Name lRAActionTableTable Object ID 1.3.6.1.4.1.674.10892.1.1500.20 Description Defines the LRA Action Table.
LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index.
LRA Action Table User Application Name Name lRAActionTableUserApplicationName Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.3 Description When the "execute application value" is set, provides the following user-assignable LRA information: • Name of the user application executable path • File name to execute Syntax DisplayString (SIZE (0..256)) Access Read-write LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.
Table 17-1. LRA Capabilities Definitions (continued) Variable Name: DellLocalResponseAgentCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value rebootCapable(16) The LRA can reboot the system. powerCycleCapable(32) The LRA is capable of a system power cycle. powerOFFCapable(64) The LRA can shut the system power off. executeApplicationCapable(256) The LRA can execute a user mode application. lraFullyCapable(383) Table 17-2. The LRA has all of the preceding capabilities.
Table 17-2. LRA Thermal Shutdown Capabilities Unique (continued) Variable Name: DellLRAThermalShutdownCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value enableOnFailureCapable(10) The LRA enables activation of chassisdetermined action(s) when a failure condition is detected. The LRA enables activation of chassisdetermined action(s) when either a failure or a warning condition is detected. enableOnWarningOrFailure Capable(14) Table 17-3.
Cost of Ownership Group 18 The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accurate and complete measurements of the cost of each computer asset in your organization.
Cost of Ownership Table Entry Name cooTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1 Description Defines the Cost of Ownership Table entry. Syntax CooTableEntry Access Not accessible Index coochassisIndex COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only COO State Name cooState Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.
COO Acquisition Waybill Number Name cooAquisitionWayBillNumber Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.4 Description Defines the waybill number of the system. Syntax DellUnsigned32BitRange Access Read-write COO Acquisition Install Date Name Name cooAquisitionInstallDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.5 Description Defines the installation date and time for the system.
COO Acquisition Signing Authority Name Name cooAquisitionSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.8 Description Defines the name of the authorized person who signs for the system. Syntax DellCostofOwnershipString Access Read-write COO Original Machine Configuration Expensed Name cooOriginalMachineConfigurationExpensed Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.9 Description Specifies whether the purchase of this system was expensed.
COO User Information User Name Name cooUserInformationUserName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12 Description Defines the name of the user for this system. Syntax DellCostofOwnershipString Access Read-write COO Extended Warranty Start Date Name Name cooExtendedWarrantyStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.13 Description Defines the extended warranty start date for this system.
COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-write COO Ownership Code Name cooOwnershipCode Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17 Description Defines the ownership code for this system. Syntax DellCooOwnershipCodes (See Table 18-1.
COO Deployment Date Length Name cooDeploymentDateLength Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.20 Description Defines the deployment time for this system. Syntax DellUnsigned32BitRange Access Read-write COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system. Syntax DellCooHourDayDurationType (See Table 18-2.
COO Outsourcing Service Fee Name Name cooOutsourcingServiceFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.24 Description Defines amount that the outsourcing vendor charges for service. Syntax DellCostofOwnershipString Access Read-write COO Outsourcing Signing Authority Name Name cooOutsourcingSigningAuthorityName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.25 Description Defines the name of the person who can sign the authorization for service.
COO Insurance Company Name Name cooInsuranceCompanyName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.28 Description Defines the name of the company that insures this system. Syntax DellCostofOwnershipString Access Read-write COO Box Asset Tag Name Name cooBoxAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.29 Description Defines the name of the asset tag. Syntax DellCostofOwnershipString Access Read-write COO Box System Name Name cooBoxSystemName Object ID 1.3.6.1.4.1.674.
COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system. Syntax DellCostofOwnershipString Access Read-write COO Operating System Upgrade Patch Level Name Name cooOperatingSystemUpgradePatchLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.33 Description Defines the name of the operating system patch level for this system.
COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-write COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system.
COO Service Contract Table The service contract table provides MIB objects that help you track the name, vendor, and type of service contract you have for your system. Name cooServiceContractTable Object ID 1.3.6.1.4.1.674.10892.1.1600.20 Description Defines the COO Service Contract Table. Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.20.
COO Service Contract State Name cooServiceContractState Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.3 Description Defines the status of the service contract for this system. Syntax DellStateSettings Access Read-only COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed.
COO Cost Event Log Table The COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of events that are logged for a particular system. Name cooCostEventLogTable Object ID 1.3.6.1.4.1.674.10892.1.1600.30 Description Defines the COO Cost Event Log Table. Syntax SEQUENCE OF COO CostEventLogTableEntry Access Not accessible COO Cost Event Log Table Entry Name cooCostEventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.30.
COO Cost Event Log State Name cooCostEventLogState Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.3 Description Defines the cost event log state of this system. Syntax DellStateSettings Access Read-only COO Cost Event Log Duration Name cooCostEventLogDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.4 Description Defines the duration of the event for this system.
COO Warranty Table The COO Warranty Table objects enable you to track facts about the type and duration of the warranty for a particular system. Name cooWarrantyTable Object ID 1.3.6.1.4.1.674.10892.1.1600.40 Description Defines the COO Warranty Table. Syntax SEQUENCE OF CooWarrantyTableEntry Access Not accessible COO Warranty Table Entry Name cooWarrantyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1 Description Defines the COO Warranty Table entry.
COO Warranty State Name cooWarrantyState Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.3 Description Defines the state of the warranty for this system. Syntax DellStateSettings Access Read-only COO Warranty Duration Name cooWarrantyDuration Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.4 Description Defines the duration of the warranty. Syntax DellUnsigned32BitRange Access Read-write COO Warranty Duration Type Name cooWarrantyDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.
COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7 Description Defines the cost of the warranty for this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information Table The COO lease information MIB objects enable you to track information about your lessor, lease duration, and lease type for each system. Name cooLeaseInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.50 Description Defines the COO Lease Information Table.
COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system. Syntax DellObjectRange Access Read-only COO Lease Information State Name cooLeaseInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.3 Description Defines the lease information state for this system.
COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-write COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system.
COO Schedule Number Table Name cooScheduleNumberTable Object ID 1.3.6.1.4.1.674.10892.1.1600.60 Description Defines the COO Schedule Number Information Table. Syntax SEQUENCE OF CooScheduleNumberTableEntry Access Not accessible COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1 Description Defines the COO Schedule Number Information Table entry.
COO Schedule Number State Name cooScheduleNumberState Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.3 Description Defines the schedule number information state of this system. Syntax DellStateSettings Access Read-only COO Schedule Number Lease Information Index Reference Name cooScheduleNumberLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.4 Description Defines the lease information index number to reference the schedule number.
COO Options Table Entry Name cooOptionsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1 Description Defines the COO Options Table entry. Syntax CooOptionsTableEntry Access Not accessible Index cooOptionschassisIndex, cooOptionsIndex COO Options Chassis Index Name cooOptionschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.1 Description Defines the index (one-based) of this chassis.
COO Options Lease Information Index Reference Name cooOptionsLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.4 Description Defines the lease information index of the option information for this system. Syntax DellUnsigned32BitRange Access Read-write COO Options Description Name Name cooOptionsDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.5 Description Defines the option information description name.
COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Maintenance Index Name cooMaintenanceIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.2 Description Defines the index of this system’s maintenance information. Syntax DellObjectRange Access Read-only COO Maintenance State Name cooMaintenanceState Object ID 1.3.6.1.4.1.674.
COO Maintenance End Date Name Name cooMaintenanceEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5 Description Defines the end date for maintenance on this system. Syntax DellDateName Access Read-write COO Maintenance Provider Name Name cooMaintenanceProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.6 Description Defines the maintenance provider’s name.
COO Repair Table Entry Name cooRepairTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1 Description Defines the COO Repair Table entry. Syntax CooRepairTableEntry Access Not accessible Index cooRepairchassisIndex, cooRepairIndex COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Repair Index Name cooRepairIndex Object ID 1.3.6.1.4.
COO Repair Counter Name cooRepairCounter Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.4 Description Defines the number of repairs that this system has undergone. Syntax DellCostofOwnershipString Access Read-write COO Repair Vendor Name Name cooRepairVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5 Description Defines the name of the vendor that repairs this system.
COO Support Information Chassis Index Name cooSupportInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information.
COO Support Information Type Name cooSupportInformationType Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.5 Description Defines the type of component, system, or network problem that occurred. Syntax DellUnsigned32BitRange Access Read-write COO Support Information Help Desk Name Name cooSupportInformationHelpDeskName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.6 Description Defines the help desk information provided.
COO Trouble Ticket Table Entry Name cooTroubleTicketTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1 Description Defines the COO Trouble Ticket Table entry. Syntax cooTroubleTicketTableEntry Access Not accessible Index cooTroubleTicketchassisIndex, cooTroubleTicketIndex COO Trouble Ticket Chassis Index Name cooTroubleTicketchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.1 Description Defines the index (one-based) of this chassis.
COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupportInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.4 Description Defines the support information index that references the trouble ticket. Syntax DellUnsigned32BitRange Access Read-write COO Trouble Ticket Number Name Name cooTroubleTicketNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.5 Description Defines the trouble ticket number for this system.
Table 18-2. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. hours(2) Duration time type is in hours. days(3) Duration time type is in days. Table 18-3. COO Day Month Duration Type Variable Name: DellCooDayMonthDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. days(3) Duration time type is in days.
Cost of Ownership Group
Remote Access Group 19 The Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to providing general information about the capabilities and settings of the remote access hardware, this group provides information about administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations.
Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware.
Remote Access State Settings Name remoteAccessStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5 Description Defines the state setting of the remote access hardware. Syntax DellStateSettings Access Read-write Remote Access Status Name remoteAccessStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6 Description Defines the status of the remote access hardware. Syntax DellStatus Access Read-only Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.
Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9 Description Defines the version of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Local Area Network (LAN) Capabilities Name remoteAccessLANCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14 Description Defines the LAN capabilities of the remote access hardware.
Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29 Description Defines the miscellaneous information for the remote access hardware. Syntax DisplayString (SIZE (0..63)) Access Read-write Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware.
Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote Access Remote Connect URL Name remoteAccessRemoteConnectURL Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access Table The following MIB object sets up the Remote Access Table. Name remoteAccessTable Object ID 1.3.6.1.4.1.674.10892.1.1700.10 Description Defines the Remote Access Table. Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Remote Access Table Entry Name remoteAccessTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1 Description Defines the Remote Access Table entry.
Remote Access Type Name remoteAccessType Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3 Description Defines the type of remote access hardware. Syntax DellRemoteAccessType (See Table 19-1.) Access Read-only Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.4 Description Defines the state capabilities of the remote access hardware.
Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7 Description Defines the name of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.8 Description Defines the description of the product providing the remote access functionality.
Remote Access Control Settings Name remoteAccessControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.11 Description Defines the control settings of the remote access hardware. Syntax DellRemoteAccessControlSettings (See Table 19-3.) Access Read-write Remote Access Monitor Capabilities Name remoteAccessMonitorCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.12 Description Defines the monitor capabilities of the remote access hardware.
Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.15 Description Defines the LAN settings of the remote access hardware. Syntax DellRemoteAccessLANSettings (See Table 19-7.) Access Read-write Remote Access Host Capabilities Name remoteAccessHostCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.16 Description Defines the host capabilities of the remote access hardware. Syntax DellRemoteAccessHostCapabilities (See Table 19-8.
Remote Access Out-of-Band SNMP Settings Name remoteAccessOutOfBandSNMPSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.19 Description Defines the out-of-band SNMP settings of the remote access hardware. Syntax DellRemoteAccessOutOfBandSNMPSettings (See Table 19-11.) Access Read-write Remote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP) Address Name remoteAccessSMTPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access Firmware Update IP Address Name remoteAccessFirmwareUpdateIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.23 Description Defines the IP address of the update server providing the firmware image used by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Firmware Update Path Name Name remoteAccessFirmwareUpdatePathName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access NIC Static Gateway Address Name remoteAccessNICStaticGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.27 Description Defines the IP address for the gateway associated with the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Remote Access Personal Computer Memory Card International Association (PCMCIA) Info Name Name remoteAccessPCMCIAInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.30 Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Remote User Administration Table Name remoteUserAdminTable Object ID 1.3.6.1.4.1.674.10892.1.1700.
Remote User Admin Chassis Index Name remoteUserAdminChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Admin Adapter Index Name remoteUserAdminAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.2 Description Defines the index (one-based) of the remote access hardware used by this remote access user.
Remote User Admin State Settings Name remoteUserAdminStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.5 Description Defines the state settings for this remote access user. Syntax DellRemoteUserAdminStateSettings (See Table 19-13.) Access Read-write Remote User Admin Status Name remoteUserAdminStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.6 Description Defines the status for this remote access user.
Remote User Admin User Privilege Name remoteUserAdminUserPrivilege Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.9 Description Defines the privileges for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin User Privilege Capabilities Name remoteUserAdminUserPrivilegeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.10 Description Defines the privilege capabilities for this remote access user. Syntax DisplayString (SIZE (0..
Remote User Admin Alert Filter DRS Capabilities Name remoteUserAdminAlertFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.13 Description Defines the DRS events filter capabilities for this remote access user. Syntax DellUnsigned32BitRange Access Read-only Remote User Admin Alert Filter System Capabilities Name remoteUserAdminAlertFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
Remote User Admin Pager Numeric Hang-up Delay Name remoteUserAdminPagerNumericHangupDelay Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.17 Description Defines the numeric pager hang-up delay for this remote access user. Syntax DellUnsigned32BitRange Access Read-write Remote User Admin Pager Alpha Phone Number Name Name remoteUserAdminPagerAlphaPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.18 Description Defines the alphanumeric pager phone number for this remote access user.
Remote User Admin Pager Alpha Custom Message Name Name remoteUserAdminPagerAlphaCustomMessageName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.21 Description Defines the message to be sent to the alphanumeric pager to inform the user of a call by this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Alpha Modem Connect Time-out Name remoteUserAdminPagerAlphaModemConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
Remote User Admin Pager Modem Init String Name Name remoteUserAdminPagerModemInitStringName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.25 Description Defines the initialization string to be sent to the pager modem for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote User Admin Pager Modem Port Name remoteUserAdminPagerModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.26 Description Defines the port for the pager modem for this remote access user.
Remote User Admin Control Capabilities Name remoteUserAdminControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.29 Description Defines the control capabilities for this remote access user. Syntax DellRemoteUserAdminControlCapabilities (See Table 19-14.) Access Read-only Remote User Admin Control Settings Name remoteUserAdminControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.30 Description Defines the control settings for this remote access user.
Remote SNMP Trap Table Entry Name remoteSNMPTrapTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1 Description Defines the Remote Access SNMP Trap Destination Table entry. Syntax RemoteSNMPTrapTableEntry Access Not accessible Index remoteSNMPTrapChassisIndex, remoteSNMPTrapAdapterIndex, remoteSNMPTrapIndex Remote SNMP Trap Chassis Index Name remoteSNMPTrapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
Remote SNMP Trap Index Name remoteSNMPTrapIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.3 Description Defines the index (one-based) of this remote access SNMP trap destination. Syntax DellObjectRange Access Read-only Remote SNMP Trap State Capabilities Name remoteSNMPTrapStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.4 Description Defines the state capabilities of this remote access SNMP trap destination. Syntax DellRemoteSNMPTrapStateCapabilities (See Table 19-18.
Remote SNMP Trap Destination IP Address Name remoteSNMPTrapDestinationIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.7 Description Defines the IP address of this remote access SNMP trap destination. Syntax IpAddress Access Read-write Remote SNMP Trap SNMP Community Name Name remoteSNMPTrapSNMPCommunityName Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.8 Description Defines the community for traps sent to this remote access SNMP trap destination. Syntax DisplayString (SIZE (0..
Remote SNMP Trap Filter DRS Capabilities Name remoteSNMPTrapFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.11 Description Defines the DRS events filter capabilities for this remote access SNMP trap destination. Syntax DellUnsigned32BitRange Access Read-only Remote SNMP Trap Filter System Capabilities Name remoteSNMPTrapFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
Remote Dial-Up Table Name remoteDialUpTable Object ID 1.3.6.1.4.1.674.10892.1.1700.40 Description Defines the Remote Access Dial-Up Table. Syntax SEQUENCE OF RemoteDialUpTableEntry Access Not accessible Remote Dial-Up Table Entry Name remoteDialUpTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1 Description Defines the Remote Access Dial-Up Table entry.
Remote Dial-Up Adapter Index Name remoteDialUpAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-up functionality. Syntax DellObjectRange Access Read-only Remote Dial-Up Index Name remoteDialUpIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.3 Description Defines the index (one-based) of this remote access dial-up functionality.
Remote Dial-Up Status Name remoteDialUpStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.6 Description Defines the status of this remote access dial-up functionality. Syntax DellStatus Access Read-only Remote Dial-Up PPP Dial-In Base IP Address Name remoteDialUpPPPDialInBaseIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.7 Description Defines the base IP address of the PPP server for this remote access dial-up functionality.
Remote Dial-Up Dial-Out Modem Connect Time-out Name remoteDialUpDialOutModemConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.10 Description Defines the modem dial-out time-out value in seconds for this remote access dial-up functionality. Syntax DellUnsigned32BitRange Access Read-write Remote Dial-Up Modem Dial Type Name remoteDialUpModemDialType Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
Remote Dial-Up Modem Port Name remoteDialUpModemPort Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.14 Description Defines the port for the modem used by this remote access dialup functionality. Syntax DellUnsigned32BitRange Access Read-write Remote User Dial-In Configuration Table Name remoteUserDialInCfgTable Object ID 1.3.6.1.4.1.674.10892.1.1700.50 Description Defines the Remote Access User Dial-In Configuration Table.
Remote User Dial-In Configuration Chassis Index Name remoteUserDialInCfgChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Remote User Dial-In Configuration Adapter Index Name remoteUserDialInCfgAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.
Remote User Dial-In Configuration State Settings Name remoteUserDialInCfgStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.5 Description Defines the state settings of this remote access dial-in user. Syntax DellRemoteUserDialInStateSettings (See Table 19-26.) Access Read-write Remote User Dial-In Configuration Status Name remoteUserDialInCfgStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.6 Description Defines the status of this remote access dial-in user.
Remote User Dial-In Configuration Callback Phone Number Name Name remoteUserDialInCfgCallbackPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.9 Description Defines the callback phone number for this remote access dial-in user. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote Dial-Out Table Name remoteDialOutTable Object ID 1.3.6.1.4.1.674.10892.1.1700.60 Description Defines the Remote Access Dial-Out Table.
Remote Dial-Out Adapter Index Name remoteDialOutAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-out functionality. Syntax DellObjectRange Access Read-only Remote Dial-Out Dial-Out Index Name remoteDialOutDialOutIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.3 Description Defines the index (one-based) of this remote access dial-out functionality.
Remote Dial-Out Status Name remoteDialOutStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.6 Description Defines the status of this remote access dial-out functionality. Syntax DellStatus Access Read-only Remote Dial-Out IP Address Name remoteDialOutIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.7 Description Defines the IP address for this remote access dial-out destination.
Remote Dial-Out PPP Password Name Name remoteDialOutPPPPasswordName Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.10 Description Defines the PPP password for this remote access dial-out destination. Syntax DisplayString (SIZE (0..31)) Access Read-write Remote Access Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 19-1.
Table 19-2. Remote Access Control Capabilities (continued) Variable Name: DellRemoteAccessControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value logResetCapable(2) The remote access hardware can reset its integrated logs. hardResetCapable(4) The remote access hardware can perform a hard reset. softResetCapable(8) The remote access hardware can perform a soft reset. gracefulResetCapable(16) The remote access hardware can gracefully shut down and perform a soft reset.
Table 19-3. Remote Access Control Settings (continued) Variable Name: DellRemoteAccessControlSettings Data Type: Integer Possible Data Values Meaning of Data Value gracefulReset(16) The remote access hardware will gracefully shut down and perform a soft reset. defaultConfigReset(32) The remote access hardware will reset to its default settings. shutdown(64) The remote access hardware will shut down. Table 19-4.
Table 19-5. Remote Access Monitor Settings Variable Name: DellRemoteAccessMonitorSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no monitor settings. unknown(1) The remote access hardware monitor settings are unknown. extPwrSupplyMonitorIfConn The remote access hardware will monitor the ectedEnabled(2) external power supply, if connected.
Table 19-7. Remote Access LAN Settings Variable Name: DellRemoteAccessLANSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no LAN settings. unknown(1) The remote access hardware LAN settings are unknown. nicEnabled(2) The remote access hardware NIC is enabled. nicDHCPEnabled(4) The remote access hardware NIC will use DHCP to obtain an IP address. Table 19-8.
Table 19-9. Remote Access Host Settings Variable Name: DellRemoteAccessHostSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no host settings. unknown(1) The remote access hardware host settings are unknown. smtpEmailEnabled(2) The remote access hardware SMTP client is enabled for sending e-mail. tftpRemoteFloppyEnabled(4) The remote access hardware TFTP client is enabled for remote floppy boot.
Table 19-11. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) Settings Variable Name: DellRemoteAccessOutOfBandSNMPSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no out-of-band SNMP settings. unknown(1) The remote access hardware out-of-band SNMP settings are unknown. oobSNMPAgentEnabled(2) The remote access hardware out-of-band SNMP agent is enabled.
Table 19-13. Remote User Admin State Settings Variable Name: DellRemoteUserAdminStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no state settings. unknown(1) The admin user state settings are unknown. enabled(2) The admin user is enabled. notReady(4) The admin user is in the "not ready" state. numericPagerEnabled(8) Numeric paging is enabled for the admin user. alphaPagerEnabled(16) Alphanumeric paging is enabled for the admin user.
Table 19-15. Remote User Admin Control Settings Variable Name: DellRemoteUserAdminControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The admin user has no control settings. unknown(1) The admin user control settings are unknown. numericPagerTest(2) A numeric pager test will be performed for the admin user. alphaPagerTest(4) An alphanumeric pager test will be performed for the admin user. emailTest(8) An e-mail test will be performed for the admin user.
Table 19-17. Remote User Admin Alpha Baud Type Variable Name: DellRemoteUserAdminAlphaBaudType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The remote user alphanumeric baud rate is not one of the following: unknown(2) The remote user alphanumeric baud rate is unknown. alphaBaud300(3) The remote user alphanumeric baud rate is 300. alphaBaud1200(4) The remote user alphanumeric baud rate is 1200. Table 19-18.
Table 19-20. Remote SNMP Trap Control Capabilities Variable Name: DellRemoteSNMPTrapControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no control capabilities. unknownCapabilities The SNMP trap destination control capabilities are (1) unknown. trapTestCapable(2) A SNMP trap test can be performed for the SNMP trap destination. Table 19-21.
Table 19-22. Remote Dial-Up State Capabilities (continued) Variable Name: DellRemoteDialUpStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value notReadyCapable(4) The dial-up functionality can be in the "not ready" state. dialInCapable(8) The dial-up functionality can support the dial-in feature. dialOutCapable(16) The dial-up functionality can support the dial-out feature.
Table 19-23. Remote Dial-Up State Settings (continued) Variable Name: DellRemoteDialUpStateSettings Data Type: Integer Possible Data Values Meaning of Data Value dialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP address for the dial-in feature. dialInAuthAnyEnabled The dial-up functionality accepts any authentication (64) type (including clear text) for the dial-in feature.
Table 19-25. Remote User Dial-In State Capabilities Variable Name: DellRemoteUserDialInStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-in user has no state capabilities. unknownCapabilities(1) The dial-in user state capabilities are unknown. enableCapable(2) The dial-in user can be disabled or enabled. notReadyCapable(4) The dial-in user can be in the "not ready" state.
Table 19-27. Remote Dial-Out State Capabilities Variable Name: DellRemoteDialOutStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state capabilities. unknownCapabilities(1) The dial-out destination state capabilities are unknown. enableCapable(2) The dial-out destination can be disabled or enabled. notReadyCapable(4) The dial-out destination can be in the "not ready" state.
Table 19-28. Remote Dial-Out State Settings Variable Name: DellRemoteDialOutStateSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state settings. unknown(1) The dial-out destination state settings are unknown. enabled(2) The dial-out destination is disabled or enabled. notReady(4) The dial-out destination is in the "not ready" state.
Remote Access Group
20 Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher availability, scalability, and management. Higher availability is achieved by using "failover" clusters, in which resources can automatically move between two or more systems in the event of a failure. Scalability is achieved by balancing the load of an application across several computer systems.
Cluster Chassis Index Name clusterChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Cluster Index Name clusterIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.2 Description Defines the index (one-based) of the cluster. Syntax DellObjectRange Access Read-only Cluster State Capabilities Name clusterStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.
Cluster Status Name clusterStatus Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.5 Description Defines the status of the cluster. Syntax DellStatus Access Read-only Cluster Type Name clusterType Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.6 Description Defines the type of the cluster. Syntax DellClusterType Access Read-only Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.
Cluster Group Variable Values This section includes definitions for Server Administrator-specific variable values used in this section. Table 20-1. Cluster Type Variable Name: DellClusterType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The cluster type is unknown. highAvailabilityCluster(2) The cluster type is a high-availability cluster.
21 Baseboard Management Controller Group The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system.
BMC Table Entry Name bmcTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1 Description Defines the Baseboard Management Controller (BMC) Table Entry. Syntax BmcTableEntry Access Not accessible Index bmcChassisIndex, bmcIndex BMC Chassis Index Name bmcChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only BMC Index Name bmcIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.
BMC State Settings Name bmcStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.4 Description Defines the state settings of the BMC. Syntax DellStateSettings Access Read-write BMC Status Name bmcStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5 Description Defines the status of the BMC. Syntax DellStatus Access Read-only BMC Display Name Name bmcDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.6 Description Defines the display name of the BMC.
BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.8 Description Defines the version of the Intelligent Platform Management Interface (IPMI) specification that the BMC supports. Syntax DellString Access Read-only BMC GUID Name bmcGUID Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.9 Description Defines the Globally Unique ID (GUID) of the BMC. Syntax OCTET STRING (SIZE(16)) Access Read-only BMC Type Name bmcType Object ID 1.3.6.1.4.1.674.10892.1.
BMC IPv4 URL Name Name bmcIPv4URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.12 Description Defines the IPv4 URL for the BMC. The URL is not present on all systems. Syntax DisplayString (SIZE (0..1024)) Access Read-only BMC IPv6 URL Name Name bmcIPv6URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.13 Description Defines the IPv6 URL for the BMC. The URL is not present on all systems. Syntax DisplayString (SIZE (0..
BMC Serial Interface Table Entry Name bmcSerialInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1 Description Defines the BMC Serial Interface Table Entry. Syntax BmcSerialInterfaceTableEntry Access Not accessible Index bmcSerialInterfaceChassisIndex, bmcSerialInterfaceBMCIndex, bmcSerialInterfaceIndex BMC Serial Interface Chassis Index Name bmcSerialInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.
BMC Serial Interface State Capabilities Name bmcSerialInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.4 Description Defines the state capabilities of the BMC serial interface. Syntax DellStateCapabilities Access Read-only BMC Serial Interface State Settings Name bmcSerialInterfaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.5 Description Defines the state settings of the BMC serial interface.
BMC Serial Interface Connection Mode Capabilities Name bmcSerialInterfaceConnectionModeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.8 Description Defines the connection mode capabilities of the BMC serial interface. Syntax DellBMCSerialConnectionModeCapabilities Access Read-only BMC Serial Interface Connection Mode Settings Name bmcSerialInterfaceConnectionModeSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.
Baseboard Management Controller LAN Interface Table Name bmcLANInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.30 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table. Syntax SEQUENCE OF BmcLANInterfaceTableEntry Access Not accessible BMC LAN Interface Table Entry Name bmcLANInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table Entry.
BMC LAN Interface BMC Index Name bmcLANInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.2 Description Defines the index (one-based) of the associated BMC. Syntax DellObjectRange Access Read-only BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3 Description Defines the index (one-based) of the BMC LAN interface.
BMC LAN Interface Status Name bmcLANInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.6 Description Defines the status of the BMC LAN interface. Syntax DellStatus Access Read-only BMC LAN Interface Channel Number Name bmcLANInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.7 Description Defines the BMC channel number of the BMC LAN interface.
BMC LAN Interface Subnet Mask Address Name bmcLANInterfaceSubnetMaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.10 Description Defines the subnet mask of the BMC LAN interface. Syntax IpAddress Access Read-only BMC LAN Interface Default Gateway Address Name bmcLANInterfaceDefaultGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.11 Description Defines the IP address of the default gateway for the BMC LAN interface.
Baseboard Management Controller Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 21-1. BMC Serial Connection Mode Capabilities Variable Name: DellBMCSerialConnectionModeCapabilities Data Type: Integer These values are bit masks; therefore, combination values are possible. Possible Data Values Meaning of Data Value -- none(0) No mode capabilities. modemBasic(1) BMC serial interface supports Modem Basic mode.
Table 21-3. BMC Serial Flow Control Type Variable Name: DellBMCSerialFlowControlType Data Type: Integer Possible Data Values Meaning of Data Value -- none(0) No flow control used. rtscts(1) RTS/CTS (hardware) flow control used. xonXoff(2) XON/XOFF flow control used. Table 21-4.
Table 21-6. BMC Management Controller Type Variable Name: DellManagementControllerType Data Type: Integer Possible Data Values Meaning of Data Value -- legacyBMC(0) Controller type is legacy Baseboard Management Controller. iDRAC(8) Controller type is iDRAC.
Baseboard Management Controller Group
22 Field Replaceable Unit Group A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system. Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field replaceable units. The following MIB tables define the FRU group.
FRU Chassis Index Name fruChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1 Description Defines the index (one-based) of the chassis containing the FRU. Syntax DellObjectRange Access Read-only FRU Index Name fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2 Description Defines the index (one-based) of the FRU. Syntax DellObjectRange Access Read-only FRU Information Status Name fruInformationStatus Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.
FRU Device Name Name fruDeviceName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.5 Description Defines the device name of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturer Name Name fruManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.6 Description Defines the manufacturer of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Serial Number Name Name fruSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.
FRU Revision Name Name fruRevisionName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9 Description Defines the revision of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only FRU Manufacturing Date Name Name fruManufacturingDateName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.10 Description Defines the manufacturing date of the FRU. Syntax DellDateName Access Read-only FRU Asset Tag Name Name fruAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.
FRU Group Variable Values This section includes definitions for server administrator-specific variable values. Table 22-1. FRU Information State Variable Name: DellFRUInformationState Data Type: Integer Possible Data Values Meaning of Data Value ok(1) FRU information is okay. notSupported(2) FRU information is not supported. notAvailable(3) FRU information is not available. checksumInvalid(4) FRU information checksum is invalid. corrupted(5) FRU information is corrupted.
Field Replaceable Unit Group
Storage Management Group 23 The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software. • Storage Management Event Group—SNMP traps.
Global Status Name globalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.2 Description Identifies global health for the subsystem managed by the Storage Management software. This global status is customized for HP OpenView. Other applications should refer to the agentSystemGlobalStatus entry in the globalData object group. Possible values: 1: Critical 2: Warning 3: Normal 4: Unknown Syntax Integer Access Read-only Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.
Software Description Name softwareDescription Object ID 1.3.6.1.4.1.674.10893.1.20.5 Description Identifies the product description for the Storage Management software. Syntax DisplayString Access Read-only Storage Management Information Group The Storage Management Information MIB Group defines the properties that identify the Storage Management software SNMP agent. Display Name Name displayName Object ID 1.3.6.1.4.1.674.10893.1.20.100.
Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.3 Description Identifies the name of the management software manufacturer. Syntax DisplayString Access Read-only Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.4 Description This entry is obsolete. Refer to softwareVersion.
Agent Last Global Status Name agentLastGlobalStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.2 Description This entry is obsolete. Use the value agentLastGlobalSystemStatus. Syntax Integer Access Read-only Agent Time Stamp Name agentTimeStamp Object ID 1.3.6.1.4.1.674.10893.1.20.110.3 Description Identifies the last time that the agent values have been updated. Universal time in sec since UTC 1/1/70. Syntax Integer Access Read-only Agent Get Timeout Name agentGetTimeout Object ID 1.3.
Agent Modifiers Name agentModifiers Object ID 1.3.6.1.4.1.674.10893.1.20.110.5 Description Identifies the agent functional modifiers. When set, the modifier is active. Bit definitions: Bit 3: agent in debug mode. All other bits are product specific. Syntax Integer Access Read-only Agent Refresh Rate Name agentRefreshRate Object ID 1.3.6.1.4.1.674.10893.1.20.110.6 Description Identifies the rate, given in seconds, at which the cached data for SNMP is refreshed.
Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.8 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.9 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Agent SNMP Version Name agentSnmpVersion Object ID 1.3.6.1.4.1.674.10893.1.20.110.10 Description This entry is obsolete.
Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Agent Global System Status Name agentGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.13 Description Global health information for the subsystem managed by the Storage Management software.
Agent Last Global System Status Name agentLastGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.14 Description The previous global status of the system managed by the Storage Management software. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Agent Smart Thermal Shutdown Name agentSmartThermalShutdown Object ID 1.3.6.1.4.1.674.10893.1.20.110.
Physical Devices Group The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their relationships to each other. The following MIB tables define objects and relationships (connections) among the objects. 552 • Controller Table—describes available properties for each controller on the managed system. • Channel Table—describes available properties for each channel on the managed system.
• Temperature Probe Table—describes available properties for each temperature probe on the managed system. • Temperature Probe Connection Table—describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure "number" in the table corresponds to that enclosure instance in the Enclosure Table. • EMM Table—describes available properties for each Enclosure Management Module (EMM) on the managed system.
Controller Entry Name controllerEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1 Description Defines the controller table entry, which is an entry in the table of RAID controllers. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax ControllerEntry Access Not accessible Index controllerNumber Controller Number Name controllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's (re)seller's name. Syntax DisplayString Access Read-only Controller Type Name controllerType Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Controller State Name controllerState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.5 Description Identifies the status of the controller's subsystem (which includes any devices connected to it). Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded Syntax Integer Access Read-only Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management.
Controller Firmware Version Name controllerFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.8 Description Identifies the controller's current firmware version. Syntax DisplayString Access Read-only Controller Cache Size in Megabytes Name controllerCacheSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.9 Description Identifies the controller's current amount of cache memory in megabytes. If this size is 0, it is less than a megabyte.
Controller Logical Device Count Name controllerLogicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.12 Description Identifies the number of virtual disks on the controller. Syntax Integer Access Read-only Controller Partner Status Name controllerPartnerStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.13 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Controller Host Port Count Name controllerHostPortCount Object ID 1.3.6.
Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16 Description Identifies the size of memory on the controller that is less than a megabyte. This combined with the controllerMemorySizeInMB will be the total size of the memory. This attribute is only supported on Adaptec controllers. Syntax Integer Access Read-only Controller Drive Channel Count Name controllerDriveChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Controller C0 Port 0 World Wide Name Name controllerC0Port0WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.19 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C0 Port 0 Name Name controllerC0Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.20 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Controller C0 Channel Name controllerC0Channel Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.23 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Controller C0 Operating System Controller Name controllerC0OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.24 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Controller C1 Port 0 Name Name controllerC1Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.27 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller C1 Port 0 ID Name controllerC1Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.28 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Controller C1 Operating System Controller Name controllerC1OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller Battery State C1 Name controllerC1BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.32 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Controller C1 Port 1 World Wide Name Name controllerC1Port1WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.35 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Controller Component Status Name controllerComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.38 Description Indicates the status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 Description Durable unique ID for this controller.
Controller Driver Version Name controllerDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.41 Description Indicates currently installed driver version of the controller Syntax DisplayString Access Read-only Controller PCI Slot Name controllerPCISlot Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.44 Description The minimum firmware version for Storage Management to support the controller. Syntax DisplayString Access Read-only Controller Minimum Driver Version Name controllerMinDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.45 Description The minimum driver version for Storage Management to support the controller.
Controller Reconstruct Rate Name controllerReconstructRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.48 Description The rate for reconstruct on the controller. Syntax Integer Access Read-write Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.49 Description The rate for patrol read on the controller. Syntax Integer Access Read-only Controller BGI Rate Name controllerBGIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Controller Patrol Read Mode Name controllerPatrolReadMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.52 Description Identifies the patrol read mode. Possible values: 1: Automatic (enabled) 2: Manual (enabled) 3: Disabled Syntax Integer Access Read-only Controller Patrol Read State Name controllerPatrolReadState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.53 Description The state of the patrol read.
Channel Table This table describes available properties for each channel on the managed system. The following object sets up the Channel Table. Name channelTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.2 Description Defines the channel table. Syntax SEQUENCE OF ChannelEntry Access Not accessible Channel Entry Name channelEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1 Description Defines the channel table entry.
Channel Name Name channelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.2 Description Identifies the name of the channel as represented in Storage Management. The name will include the word channel and the instance. For example: Channel 1. Syntax DisplayString Access Read-only Channel State Name channelState Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.3 Description Identifies the current state of this channel. Possible states: 0: Unknown 1: Ready - The I/O has resumed.
Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on this channel. Termination is required for proper operation of this channel. Possible values: 1: Wide Termination (16 bit) 2: Narrow Termination (8 bit) 3: Not Terminated Syntax Integer Access Read-only Channel SCSI ID Name channelSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
Channel Roll-Up Status Name channelRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.7 Description Identifies the severity of the channel state. This is the combined status of the channel and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.9 Description Durable unique ID for this channel. Syntax DisplayString Access Read-only Channel Data Rate Name channelDataRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.10 Description Identifies the data rate of this channel. Syntax DisplayString Access Read-only Channel Bus Type Name channelBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.11 Description The bus type of the channel.
Enclosure Table This table describes available properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table. Syntax SEQUENCE OF EnclosureEntry Access Not accessible Enclosure Entry Name enclosureEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1 Description Defines the enclosure table entry.
Enclosure Name Name enclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2 Description Identifies the enclosure's name as represented in Storage Management. Syntax DisplayString Access Read-only Enclosure Vendor Name enclosureVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.3 Description Identifies the enclosure's (re)seller's name. Syntax DisplayString Access Read-only Enclosure State Name enclosureState Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Enclosure Severity Name enclosureSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Enclosure ID Name enclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6 Description Identifies the SCSI address of the processor. Syntax Integer Access Read-only Enclosure Processor Version Name enclosureProcessorVersion Object ID 1.
Enclosure Asset Tag Name enclosureAssetTag Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.9 Description Customer definable asset tag for the enclosure. Syntax DisplayString Access Read-only Enclosure Asset Name Name enclosureAssetName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.10 Description Customer definable asset name of the enclosure. Syntax DisplayString Access Read-only Enclosure Split Bus Part Number Name enclosureSplitBusPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Enclosure Kernel Version Name enclosureKernelVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.13 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Enclosure ESM1 Part Number Name enclosureESM1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.14 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Enclosure ESM2 Part Number Name enclosureESM2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.
Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure.
Enclosure Configuration Name enclosureConfig Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.18 Description Identifies the current configuration of the enclosure's backplane. Possible values: 1: Joined 2: Split Bus 3: Clustered 4: Unified Syntax Integer Access Read-only Enclosure Channel Number Name enclosureChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.19 Description Identifies the channel number, or bus, to which the enclosure is connected.
Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.21 Description Identifies the part number of the enclosure's backplane. Syntax Integer Access Read-only Enclosure SCSI ID Name enclosureSCSIID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.22 Description Identifies the SCSI ID of the controller to which this enclosure is attached. Syntax Integer Access Read-only Enclosure Roll-Up Status Name enclosureRollUpStatus Object ID 1.
Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24 Description The status of the enclosure itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Enclosure Nexus ID Name enclosureNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.25 Description Durable unique ID for this enclosure.
Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27 Description Actual SCSI rate in the enclosure. Syntax DisplayString Access Read-only Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28 Description The part number of the enclosure. Syntax DisplayString Access Read-only Enclosure Serial Number Name enclosureSerialNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Array Disk Table This table describes available properties for each physical array disk on the managed system. The following object sets up the Array Disk Table. Name arrayDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4 Description Defines the array disk table. Syntax SEQUENCE OF ArrayDiskEntry Access Not accessible Array Disk Entry Name arrayDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1 Description Defines the array disk table entry.
Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 Description Identifies the name of the array disk as represented in Storage Management. Syntax DisplayString Access Read-only Array Disk Vendor Name arrayDiskVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3 Description The array disk's manufacturer's name.
Array Disk State Name arrayDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4 Description Identifies the current state of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller. 6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk.
Array Disk Severity Name arrayDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Array Disk Product ID Name arrayDiskProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.6 Description Identifies the model number of the array disk.
Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs. Syntax DisplayString Access Read-only Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 Description Identifies the bus to which this array disk is connected.
Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.13 Description The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte. Syntax Integer Access Read-only Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Array Disk Used Space in Megabytes Name arrayDiskUsedSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.17 Description Identifies the amount in megabytes of the used space on the array disk. If this size is 0, it is smaller than a megabyte. Syntax Integer Access Read-only Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.18 Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte.
Array Disk Free Space in Bytes Name arrayDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.20 Description Identifies the size in bytes of the free space on the array disk that is smaller than a megabyte. This size plus the arrayDiskFreeSpaceInMB is the total amount of free space on the array disk. Syntax Integer Access Read-only Array Disk Bus Type Name arrayDiskBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.21 Description Identifies the bus type of the array disk.
Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare. Possible states: 1: Disk is a member of a virtual disk 2: Disk is a member of a disk group 3: Disk is a global hot spare 4: Disk is a dedicated hot spare 5: Not a spare 99: Not applicable Syntax Integer Access Read-only Array Disk Roll-Up Status Name arrayDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Array Disk Component Status Name arrayDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.24 Description The status of the array disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Array Disk Part Number Name arrayDiskPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.27 Description Indicates the part number of the disk. Syntax DisplayString Access Read-only Array Disk SAS Address Name arrayDiskSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.28 Description Indicates the specified SAS address if this is a SAS disk. Syntax DisplayString Access Read-only Array Disk Negotiated Speed Name arrayDiskNegotiatedSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.
Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.31 Description Indicates whether the disk has received a predictive failure. Possible values: 1: No - disk has not received a predictive failure alert 2: Yes - disk has received a predictive failure alert Syntax Integer Access Read-only Array Disk Manufacture Day Name arrayDiskManufactureDay Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 Description Indicates the four digit year in which this disk was manufactured. Syntax DisplayString Access Read-only Array Disk Media Type Name arrayDiskMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35 Description Indicates the media type of the array disk.
Array Disk Enclosure Connection Entry Name arrayDiskEnclosureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1 Description Defines the array disk enclosure connection table entry. Syntax ArrayDiskEnclosureConnectionEntry Access Not accessible Index arrayDiskEnclosureConnectionNumber Array Disk Enclosure Connection Number Name arrayDiskEnclosureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
Array Disk Enclosure Connection Array Disk Number Name arrayDiskEnclosureConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.3 Description Identifies the instance number of the array disk in the arrayDiskTable in this connection. Syntax Integer Access Read-only Array Disk Enclosure Connection Enclosure Name Name arrayDiskEnclosureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
Array Disk Enclosure Connection Controller Name Name arrayDiskEnclosureConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.6 Description Identifies the name of the controller as represented in Storage Management to which this array disk is connected. Syntax DisplayString Access Read-only Array Disk Enclosure Connection Controller Number Name arrayDiskEnclosureConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
Array Disk Channel Connection Entry Name arrayDiskChannelConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1 Description Defines the array disk channel connection table entry. Syntax ArrayDiskChannelConnectionEntry Access Not accessible Index arrayDiskEnclosureConnectionNumber Array Disk Channel Connection Number Name arrayDiskChannelConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.1 Description Identifies the instance number of the array disk channel connection entry.
Array Disk Channel Connection Channel Name Name arrayDiskChannelConnectionChannelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.4 Description Identifies the name of the channel as represented in Storage Management to which is array disk is connected. Syntax DisplayString Access Read-only Array Disk Channel Connection Channel Number Name arrayDiskChannelConnectionChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.
Fan Table This table describes available properties for each fan on the managed system. The following object sets up the Fan Table. Name fanTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.7 Description Defines the fan table. Syntax SEQUENCE OF FanEntry Access Not accessible Fan Entry Name fanEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1 Description Defines the fan table entry. Syntax FanEntry Access Not accessible Index fanNumber Fan Number Name fanNumber Object ID 1.3.6.1.4.1.
Fan Name Name Fan Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.2 Description Identifies the fan's name as represented in Storage Management. Syntax DisplayString Access Read-only Fan Vendor Name fanVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.3 Description Identifies the fan's (re)seller's name. Syntax DisplayString Access Read-only Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 Description Identifies the current state of the fan.
Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Fan Probe Unit Name fanProbeUnit Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.6 Description This entry is obsolete for Storage Services. Syntax DisplayString Access Read-only Fan Probe Minimum Warning Name fanProbeMinimumWarning Object ID 1.3.6.1.4.
Fan Probe Maximum Warning Name fanProbeMaximumWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.9 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Fan Probe Maximum Critical Name fanProbeMaximumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.10 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management.
Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.13 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Fan Roll-Up Status Name fanRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.14 Description Severity of the fan state. This is the combined status of the fan and its components.
Fan Component Status Name fanComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.15 Description The status of the fan itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for this fan.
Fan Connection Table This table describes the connection between each fan on the managed system and its enclosure. Each enclosure "number" in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Fan Connection Table. Name fanConnectionTable Object ID fanConnectionTable Description Defines the fan connection table. Syntax SEQUENCE OF FanConnectionEntry Access Not accessible Fan Connection Entry Name fanConnectionEntry Object ID 1.3.6.1.4.1.
Fan Connection Fan Name Name fanConnectionFanName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.2 Description Identifies the name of the fan in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Fan Connection Fan Number Name fanConnectionFanNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.3 Description Identifies the instance number of the fan in the fanTable in the connection.
Fan Connection Enclosure Number Name fanConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs. Syntax Integer Access Read-only Power Supply Table This table describes available properties for each power supply on the managed system. The following object sets up the Power Supply Table. Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.
Power Supply Number Name powerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.1 Description Identifies the instance number of the power supply entry. Syntax Integer Access Read-only Power Supply Name Name powerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.2 Description Identifies the power supply's name as represented in Storage Management. Syntax DisplayString Access Read-only Power Supply Vendor Name powerSupplyVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.
Power Supply State Name powerSupplyState Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.4 Description Identifies the current state of the power supply. Possible states: 0: Unknown 1: Ready 2: Failed 5: Not Installed 6: Degraded 11: Removed Syntax Integer Access Read-only Power Supply Severity Name powerSupplySeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
Power Supply 2 Part Number Name powerSupply2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.7 Description This entry is obsolete. This setting is not supported by power supplies managed under Storage Management Syntax DisplayString Access Read-only Power Supply Roll-Up Status Name powerSupplyRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.8 Description Severity of the power supply state. This is the combined status of the power supply and its components.
Power Supply Component Status Name powerSupplyComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.9 Description Severity of the power supply state. This is the combined status of the power supply and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Power Supply NexusID Name powerSupplyNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.10 Description Durable unique ID for this power supply.
Power Supply Connection Table This table describes the connection between each power supply on the managed system and its enclosure. Each enclosure "number" in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Power Supply Connection Table. Name powerSupplyConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.10 Description Defines the power supply connection table.
Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.2 Description Identifies the name of the power supply in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.
Temperature Probe Table This table describes available properties for each temperature probe on the managed system. The following object sets up the Temperature Probe Table. Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.11 Description A table of managed temperature probes. The number of entries is related to the number of temperature probes discovered in the system. The maximum number of entries is implementation dependent.
Temperature Probe Name Name temperatureProbeName Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.2 Description Identifies the temperature probe's name as represented in Storage Management. Syntax DisplayString Access Read-only Temperature Probe Vendor Name temperatureProbeVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.3 Description Identifies the temperature probe's (re)seller's name.
Temperature Probe Severity Name temperatureProbeSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Temperature Probe Unit Name temperatureProbeUnit Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.6 Description The units that will be used to display temperatures for the temperature probe.
Temperature Probe Maximum Warning Name temperatureProbeMaxWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.9 Description Identifies the maximum temperature that will force the probe into a warning state. Syntax Integer Access Read-only Temperature Probe Maximum Critical Name temperatureProbeMaxCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.10 Description Identifies the maximum temperature that will force the probe into an error state.
Temperature Probe Roll-Up Status Name temperatureProbeRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.12 Description Severity of the temperature probe state. This is the combined status of the temperature probe and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Temperature Probe Component Status Name temperatureProbeComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.
Temperature Probe Nexus ID Name temperatureProbeNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.11.1.14 Description Durable unique ID for this temperature probe. Syntax DisplayString Access Read-only Temperature Probe Connection Table This table describes the connection between each temperature probe on the managed system and its enclosure. Each enclosure "number" in the table corresponds to that enclosure instance in the enclosure Table.
Temperature Probe Connection Number Name temperatureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.1 Description Identifies the instance number of the temperature probe connection entry. Syntax Integer Access Read-only Temperature Probe Connection Temperature Probe Name Name temperatureConnectionTemperatureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.2 Description Identifies the name of the temperature probe in this connection as represented in Storage Management.
Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this temperature probe belongs. Syntax Integer Access Read-only Enclosure Management Module Table This table describes available properties for each enclosure management module on the managed system. The following object sets up the Enclosure Management Module Table.
Enclosure Management Module Number Name enclosureManagementModuleNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.1 Description Identifies the instance number of the enclosure management module entry. Syntax Integer Access Read-only Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.2 Description Identifies the enclosure management module's name as represented in Storage Management.
Enclosure Management Module State Name enclosureManagementModuleState Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.4 Description Identifies the current state of the enclosure management module. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 5: Not Installed 6: Degraded 21: Missing Syntax Integer Access Read-only Enclosure Management Module Severity Name enclosureManagementModuleSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
Enclosure Management Module Type Name enclosureManagementModuleType Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.7 Description Identifies the type of the enclosure management module. Possible values: 0: Unknown 1: EMM 2: Termination Card Syntax Integer Access Read-only Enclosure Management Module Firmware Version Name enclosureManagementModuleFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.8 Description Identifies the firmware version of the enclosure memory module.
Enclosure Management Module Roll-Up Status Name enclosureManagementModuleRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.10 Description Severity of the enclosure management module state. This is the combined status of the EMM and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object ID 1.3.6.1.4.1.674.
Enclosure Management Module Nexus ID Name enclosureManagementModuleNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.12 Description Durable unique ID for this EMM. Syntax DisplayString Access Read-only Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.13 Description Identifies the revision number of the enclosure management module.
Enclosure Management Module Connection Entry Name enclosureManagementModuleConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1 Description Defines the enclosure memory module connection table entry. Syntax EnclosureManagementModuleConnectionEntry Access Not accessible Index enclosureManagementModuleConnectionNumber Enclosure Management Module Connection Number Name enclosureManagementModuleConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.
Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnectionEMMNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.3 Description Identifies the instance number in the enclosureManagementModuleTable of the enclosure memory module in this connection. Syntax Integer Access Read-only Enclosure Management Module Connection Enclosure Name Name enclosureManagementModuleConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.
Battery Table This table describes available properties for each controller battery on the managed system. The following object sets up the Battery Table. Name batteryTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.15 Description Defines the battery table. Syntax SEQUENCE OF BatteryEntry Access Not accessible Battery Entry Name batteryEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1 Description Defines the battery table entry.
Battery Name Name batteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.2 Description Identifies the battery's name as represented in Storage Management. Syntax DisplayString Access Read-only Battery Vendor Name batteryVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.3 Description Identifies the battery's (re)seller's name. Syntax DisplayString Access Read-only Battery State Name batteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
Battery Roll-Up Status Name batteryRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.5 Description Severity of the battery state. This is the combined status of the battery and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Battery Component Status Name batteryComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.
Battery Charge Count Name batteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.7 Description The number of charges that have been applied to the battery. Syntax Integer Access Read-only Battery Max Charge Count Name batteryMaxChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.8 Description The maximum number of charges that can be applied to the battery. Syntax Integer Access Read-only Battery Nexus ID Name batteryNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.
Battery Predicted Capacity Name batteryPredictedCapacity Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10 Description Displays the battery's ability to be charged. Possible values: 1: Failed - The battery cannot be charged and needs to be replaced. 2: Ready - The battery can be charged to full capacity. 4: Unknown - The battery is completing a Learn cycle. The charge capacity of the battery cannot be determined until the Learn cycle is complete.
Battery Learn State Name batteryLearnState Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.12 Description Specifies the learn state activity of the battery. Possible values: 1: Failed 2: Active 4: Timed out 8: Requested 16: Idle Syntax Integer Access Read-only Battery Maximum Learn Delay Name batteryMaxLearnDelay Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.14 Description The maximum amount of time (in hours) that the battery learn cycle can be delayed.
Battery Connection Table This table describes the connection between each controller battery on the managed system and its controller. Each controller "number" in the table corresponds to that controller instance in the controller Table. The following object sets up the Battery Connection Table. Name batteryConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.16 Description Defines the battery connection table.
Battery Connection Battery Name Name batteryConnectionBatteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.2 Description Identifies the name of the battery in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Battery Connection Battery Number Name batteryConnectionBatteryNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.3 Description Identifies the instance number in the batteryTable of the battery in this connection.
Logical Devices Group The Logical Devices Management Information Base (MIB) group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other. This group and all of its associated tables and objects are not supported on Microsoft® Windows® Advanced Server Limited Edition 64-bit operating system (Windows.Net-64) on a Dell PowerEdge™ 7150.
Virtual Disk Entry Name virtualDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1 Description Defines the virtual disk table entry. Syntax VirtualDiskEntry Access Not accessible Index virtualDiskNumber Virtual Disk Number Name virtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.1 Description Identifies the instance number of the virtual disk entry. Syntax Integer Access Read-only Virtual Disk Name Name virtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Virtual Disk State Name virtualDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4 Description Identifies the current state of this virtual disk. Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems. 2: Failed - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online. 3: Online 4: Offline - The disk is not accessible. The disk may be corrupted or intermittently unavailable.
Virtual Disk Severity Name virtualDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.6 Description Identifies the size of this virtual disk in megabytes. If this size is 0, it is smaller than a megabyte.
Virtual Disk Free Space in Megabytes Name virtualDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.8 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax Integer Access Read-only Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management.
Virtual Disk Read Policy Name virtualDiskReadPolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.11 Description Indicates whether the controller's read cache will be used when reading from a virtual disk. Possible values: 1: Enabled - Adaptec Read Cache Enabled 2: Disabled - Adaptec Read Cache Disabled 3: LSI Read Ahead 4: LSI Adaptive Read Ahead 5: LSI No Read Ahead Syntax Integer Access Read-only Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.
Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.13 Description Indicates the virtual disk's RAID type. Possible values: 1: Concatenated 2: RAID-0 3: RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAID-50 19: Concatenated RAID 1 24: RAID-60 Syntax Integer Access Read-only Virtual Disk Current Stripe Size in Megabytes Name virtualDiskCurStripeSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Virtual Disk Current Stripe Size in Bytes Name virtualDiskCurStripeSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.15 Description Identifies the portion of the stripe size in bytes that is smaller than a megabyte. This size plus the virtualDiskCurStripeSizeInMB is the total stripe size on the virtual disk. Syntax Integer Access Read-only Virtual Disk Channel Name virtualDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.16 Description This entry is obsolete.
Virtual Disk Roll-Up Status Name virtualDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.19 Description Severity of the virtual disk state. This is the combined status of the virtual disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21 Description Durable unique ID for this virtual disk. Syntax DisplayString Access Read-only Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22 Description Identifies the type of array (physical) disks used to create the virtual disk.
Name arrayDiskLogicalConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.3 Description Defines the array disk logical connection table. Syntax SEQUENCE OF arrayDiskLogicalConnectionEntry Access Not accessible Array Disk Logical Connection Entry Name arrayDiskLogicalConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1 Description Defines the array disk logical connection table entry.
Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.3 Description Identifies the instance number of the array disk in this logical connection. Syntax Integer Access Read-only Array Disk Logical Connection Virtual Disk Name Name arrayDiskLogicalConnectionVirtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.4 Description Identifies the name of the virtual disk to which this array disk belongs.
Array Disk Logical Connection Disk Number Name arrayDiskLogicalConnectionDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.7 Description Identifies the instance number of the disk group to which this array disk belongs. This property is currently not supported. Syntax Integer Access Read-only Storage Management Event Group The Storage Management Event Group defines the properties that will be sent with SNMP traps. Message ID Event Name messageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.
Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.3 Description Additional information identifying the location of the object causing the alert. Syntax DisplayString Access Read-only Object Name Event Name objectNameEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.4 Description Name of the object as represented in Storage Management causing the alert. Syntax DisplayString Access Read-only Object OID Event Name objectOIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.
Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Current status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.8 Description Previous status of object causing the alert if applicable.
Storage Management Group
Change Management Group 24 The Change Management Group lets you monitor information about the Dell™ devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. Inventory Group The following objects describe the fields for inventory information. Inventory Locale Name inventoryLocale Object ID 1.3.6.1.4.1.674.10899.1.1 Description Defines the locale of the system.
Name inventorySystemID Access Read-only Device Group The Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID. Device Group Table The following object sets up the Device Group Table. Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table.
Device Component ID Name deviceComponentID Object ID 1.3.6.1.4.1.674.10899.1.5.1.2 Description Defines an optional component ID field for the device. Syntax Integer Access Read-only Device Display String Name deviceDisplayString Object ID 1.3.6.1.4.1.674.10899.1.5.1.3 Description Provides a displayable string that describes the device. Syntax DisplayString Access Read-only Device Vendor ID Name deviceVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.
Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.6 Description Provides additional device identification. Syntax Octet String Access Read-only Device Sub Vendor ID Name deviceSubVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.7 Description Provides additional vendor identification. Syntax Octet String Access Read-only Application Group NOTE: Dell updateable components such as Basic input/output system (BIOS) and FirmWare (FW) are considered applications.
Application Group Table The following object sets up the Application Group Table. Name applicationTable Object ID 1.3.6.1.4.1.674.10899.1.6 Description Defines a table of application information for the system. Syntax SEQUENCE OF ApplicationEntry Access Not accessible Application Entry Name applicationEntry Object ID 1.3.6.1.4.1.674.10899.1.6.1 Description Defines an application entry. Syntax ApplicationEntry Access Read-only Application Index Name applicationIndex Object ID 1.3.6.1.
Application Component Type Name applicationComponentType Object ID 1.3.6.1.4.1.674.10899.1.6.1.3 Description Identifies the type of application reported. Syntax DisplayString Access Read-only Application Version Name applicationVersion Object ID 1.3.6.1.4.1.674.10899.1.6.1.4 Description Identifies the version of the application. Syntax DisplayString Access Read-only Application Display String Name applicationDisplayString Object ID 1.3.6.1.4.1.674.10899.1.6.1.
Operating System Group The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system. The following objects describe the fields for Operating System Group. Operating System Vendor Name operatingSystemVendor Object ID 1.3.6.1.4.1.674.10899.2.1 Description Defines the vendor of the Operating System.
Operating System Service Pack Major Version Name operatingSystemSPMajorVersion Object ID 1.3.6.1.4.1.674.10899.2.5 Description Defines the Operating System's Service Pack major version. Syntax DisplayString Access Read-only Operating System Service Pack Minor Version Name operatingSystemSPMinorVersion Object ID 1.3.6.1.4.1.674.10899.2.6 Description Defines the Operating System's Service Pack minor version.
Product ID Display Name Name productIDDisplayName Object ID 1.3.6.1.4.1.674.10899.100.1 Description Defines the display name of the product. Syntax DisplayString Access Read-only Product ID Description Name productIDDescription Object ID 1.3.6.1.4.1.674.10899.100.2 Description Provides a description of the product. Syntax DisplayString Access Read-only Product ID Vendor Name productIDVendor Object ID 1.3.6.1.4.1.674.10899.100.
Product ID Build Number Name productIDBuildNumber Object ID 1.3.6.1.4.1.674.10899.100.5 Description Describes the software build number of the product.
Dell RAC Out-of-Band Group 25 The Dell RAC Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and Remote Access Controller (RAC) Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB tables define the Dell RAC Out-of-Band group: DRsProductName Name DRsProductName Object ID 1.3.6.1.4.1.674.10892.2.1.1.1 Description Defines the product name of a chassis management controller.
DRsProductDescription Name DRsProductDescription Object ID 1.3.6.1.4.1.674.10892.2.1.1.3 Description Defines the product description of a chassis management controller. Syntax DellString Access Read-only DRsProductManufacturer Name DRsProductManufacturer Object ID 1.3.6.1.4.1.674.10892.2.1.1.4 Description Defines the product manufacturer of a chassis management controller. Syntax DellString Access Read-only DRsProductVersion Name DRsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.
DRsProductURL Name DrsProductURL Object ID 1.3.6.1.4.1.674.10892.2.1.1.7 Description Defines the out-of-band UI URL of a chassis management controller. Syntax DellString Access Read-only DRsProductChassisAssetTag Name DRsProductChassisAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.8 Description Defines the Asset Tag of the chassis. Syntax DellString Access Read-only DRsProductChassisLocation Name DRsProductChassisLocation Object ID 1.3.6.1.4.1.674.10892.2.1.1.
DRsSystemServiceTag Name DRsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only DRsProductSystemAssetTag Name DRsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.12 Description Defines the asset tag of a system. Syntax DellString Access Read-only DRsProductSystemSlot Name DRsProductSystemSlot Object ID 1.3.6.1.4.1.674.10892.2.1.1.13 Description Defines the slot number of a CMC.
DRsFirmwareVersion Name DRsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description Defines the firmware version of a chassis management controller. Syntax DellString Access Read-only Chassis Status The following MIB tables provide information on Chassis being monitored by the chassis management card. DRsGlobalSystemStatus Name DRsGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.2.2.1 Description Defines the overall chassis status being monitored by the chassis management card.
DRsIOMCurrStatus Name DRsIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.2 Description Defines the IOM subsystem status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsKVMCurrStatus Name DRsKVMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.3 Description Defines the iKVM subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsRedCurrStatus Name DRsRedCurrtatus Object ID 1.3.6.1.4.1.674.
DRsPowerCurrStatus Name DRsPowerCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.5 Description Defines the power subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsFanCurrStatus Name DRsFanCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.6 Description Defines the fan subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsBladeCurrStatus Name DRsBladeCurrStatus Object ID 1.
DRsTempCurrStatus Name DRsTempCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.8 Description Defines the temperature sensor subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsCMCCurrStatus Name DRsCMCCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.9 Description Defines the CMC health status being monitored by the chassis management card.
DRsIOMPrevStatus Name DRsIOMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.2 Description Defines the previous IOM subsystem status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsKVMPrevStatus Name DRsKVMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.3 Description Defines the previous iKVM subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsRedPrevStatus Name DRsRedPrevStatus Object ID 1.3.6.1.4.1.
DRsPowerPrevStatus Name DRsPowerPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.5 Description Defines the previous power subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only DRsFanPrevStatus Name DrsFanPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.6 Description Defines the previous fan health status being monitored by the chassis management card.
DRsTempPrevStatus Name DRsTempPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.8 Description Defines the temperature sensor health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsCMCPrevStatus Name DRsCMCPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.9 Description Defines the CMC health status being monitored by the chassis management card. Syntax DellStatus Access Read-only DRsGlobalChangeTime Name DRsGlobalChangeTime Object ID 1.3.6.1.
DRsKVMChangeTime Name DRsKVMChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.3 Description Defines the timestamp of the most recent iKVM status change. Syntax TimeTicks Access Read-only DRsRedChangeTime Name DRsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only DRsPowerChangeTime Name DRsPowerChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.
DRsBladeChangeTime Name DRsBladeChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.7 Description Defines the timestamp of the most recent blade health status change. Syntax TimeTicks Access Read-only DRsTempChangeTime Name DRsTempChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.8 Description Defines the timestamp of the most recent temperature sensor health status change. Syntax TimeTicks Access Read-only DRsCMCChangeTime Name DRsCMCChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.
Chassis Power The following MIB tables provide information on the chassis management controller table entry. DRsCMC Power Table Name DRsCMCPowerTable Object ID 1.3.6.1.4.1.674.10892.2.4.1 Description Defines the CMC power table. Syntax SEQUENCE OF DrsCMCPowerTableEntry Access Not-accessible DRsCMC Power Table Entry Name DRsCMCPowerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.1.1 Description Defines the CMC power table entry.
DRsCMC PSUTableEntry Name DrsCMCPSUTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.2.1 Description Defines the CMC PSU table entry. Syntax DrsCMCPSUTableEntry Access Not-accessible CMC Power Information The following MIB tables provide information on the chassis power. DRsChassisIndex Name DrsChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1 Description Defines the index (one-based) of the associated chassis.
DRsIdlePower Name DRsIdlePower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3 Description Defines the power (in Watts) required by the chassisinfrastructure, plus the sum of the minimum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only DRsMaxPowerSpecification Name DRsMaxPowerSpecification Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.4 Description Defines the power limit (in Watts) at which server throttling will take place.
DRsKWhCumulative Name DRsKWhCumulative Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6 Description Defines the cumulative chassis power usage (in KWh) since last reset. Syntax DellPowerReading Access Read-only DRsKWhCumulativeTime Name DRsKWhCumulativeTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.7 Description Defines the timestamp of the most recent chassis power accumulator reset. Syntax DellTimestamp Access Read-only DRsWattsPeakUsage Name DRsWattsPeakUsage Object ID 1.3.6.1.4.1.674.
DRsWattsMinUsage Name DRsWattsMinUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.10 Description Defines the chassis minimum power usage (in Watts) since last reset. Syntax DellPowerReading Access Read-only DRsWattsMinTime Name DRsWattsMinTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11 Description Defines the timestamp of the most recent chassis minimum power usage. Syntax DellPowerReading Access Read-only DRsWattsResetTime Name DRsWattsResetTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
DRsWattsReading Name DRsWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13 Description Defines the instantaneous chassis power usage (in Watts) Syntax DellPowerReading Access Read-only DRsAmpsReading Name DRsAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14 Description Defines the instantaneous chassis current usage (in Watts). Syntax DellPowerReading Access Read-only CMC PSU Information The following MIB tables provide information on the chassis power supply unit.
DRsPSUIndex Name DRsPSUIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.2 Description Defines the index (one-based) of the associated CMC PSU. Syntax DellCMCPSUIndexRange Access Read-only DRsPSULocation Name DRsPSULocation Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3 Description Defines the location of the CMC PSU. Syntax DellString Access Read-only DRsPSUMonitoringCapable Name DRsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.
DRsPSUAmpsReading Name DRsPSUAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.6 Description Defines the instantaneous PSU Current reading. Syntax DellPowerReading Access Read-only DRsPSUWattsReading Name DrsPSUWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7 Description Defines the instantaneous PSU Wattage reading. Syntax DellPowerReading Access Read-only Chassis Alerts The following MIB tables provide information on the chassis management controller alerts.
DrsCASSCurrStatus Name DrsCASSCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.2 Description Defines the Current Status of the Alerting Sub-System. Syntax DellStatus Access Read-only DrsCASSPrevStatus Name DrsCASSPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.20.10.3 Description Defines the Previous Status of the Alerting Sub-System. Syntax DellStatus Access Read-only DrsCASSChangeTime Name DrsCASSChangeTime Object ID 1.3.6.1.4.1.674.10892.2.20.10.
Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. DRsAlertSystem Name DRsAlertSystem Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1 Description Name of the system generating the alert. Syntax OCTET STRING (SIZE (0..255)) Access Read-only DRsAlertTableIndexOID Name DRsAlertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.2.5000.10.2 Description Alert Index Object Identifier.
DRsAlertCurrentStatus Name DRsAlertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.4 Description Current status of object causing the alert. Syntax DellStatus Access Read-only DRsAlertPreviousStatus Name DRsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5 Description Previous status of object causing the alert. Syntax DellStatus Access Read-only DRsAlertData Name DRsAlertData Object ID 1.3.6.1.4.1.674.10892.2.5000.10.
Traps 26 The Server Administrator generates events that result in Simple Network Management Protocol (SNMP) traps or operating system event logs. Remote Access Controller (RAC) and Baseboard Management Controller (BMC) also can generate SNMP traps in response to hardware events. This section describes the traps, also known as alerts, generated by the Server Administrator, RAC, and BMC. The Server Administrator generates events in response to changes in the status of sensors and other monitored parameters.
Trap Variables This section describes the variables that are sent to the management console to provide additional information about a trap or alert generated by some event on your system. The trap variables presented here apply to all Instrumentation and RAC traps. Trap variables are sent in the order listed and are reserved for use only in traps. When a varbind is created for a trap variable, a zero is appended to the object ID (OID) to create the OID for the varbind.
Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.1.5000.10.4 Description Gives the current status of the object causing the alert. Syntax DellStatus Previous Status Variable Name alertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.1.5000.10.5 Description Gives the previous status of the object causing the alert. Syntax DellStatus Data Variable Name alertData Object ID 1.3.6.1.4.1.674.10892.1.5000.10.
Understanding the Trap Description Table 26-1 lists in alphabetical order each line item that may appear in the trap description. Table 26-1.
Table 26-1.
Table 26-1.
Table 26-1.
Table 26-1.
Instrumentation Traps This section describes the traps that are generated by the Instrumentation service of the Server Administrator. All of the traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.1 and are sent with all of the trap variables documented in the section, "Trap Variables." The trap variables are sent in the order in which they are listed.
Table 26-2. Miscellaneous Traps Trap Description ID Severity Cause System Up 1001 Server Administrator startup complete Information Server Administrator completed its initialization. Thermal Shutdown 1004 Thermal shutdown protection has been initiated Error This message is generated when a system is configured for thermal shutdown due to an error event.
Table 26-2. Miscellaneous Traps (continued) Trap Description ID Severity Cause System Peak Power New Peak 1013 System Peak Power detected new peak value Information This message is generated when the system peak power sensor has detected a new peak value. Peak value (in Watts): System Software Event 1014 System software Minor event has occured. Description: This message is generated when a system software event occurs.
Table 26-3. Temperature Probe Traps Trap ID Description Severity Cause Temperature Probe Normal 1052 Information A temperature sensor on the backplane board, system board, Sensor location: or drive carrier in the specified system Chassis location: returned to a valid range after crossing a failure threshold.
Table 26-3. Temperature Probe Traps (continued) Trap ID Description Severity Cause Error A temperature sensor on the backplane board, system board, or drive carrier in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and temperature sensor value are provided. Error A temperature sensor on the backplane board, system board, or drive carrier in the specified system detected an error from which it cannot recover.
Cooling Device Traps Cooling device traps monitor how well a fan is functioning. Table 26-4. Cooling Device Traps Trap ID Description Severity Cause Cooling Device Normal 1102 Fan sensor returned to a normal value Sensor location: Chassis location: Previous state was: Fan sensor value: Information A fan sensor reading on the specified system returned to a valid range after crossing a warning threshold.
Table 26-4. Cooling Device Traps (continued) Trap ID Description Severity Cause Error A fan sensor in the specified system detected the failure of one or more fans. The sensor location, chassis location, previous state, and fan sensor value are provided. Error A fan sensor detected an error from which it cannot recover. The sensor location, chassis location, previous state, and fan sensor value are provided.
Voltage Probe Traps Voltage probes monitor the number of volts across critical components. Table 26-5. Voltage Probe Traps Trap ID Description Severity Cause Voltage Probe Normal 1152 Information A voltage sensor in the specified system returned to a valid range Sensor location: after crossing a failure threshold. The sensor Chassis location: location, previous state, and voltage sensor value Previous state was: are provided.
Table 26-5. Voltage Probe Traps (continued) Trap ID Description Severity Cause Error A voltage sensor in the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and voltage sensor value are provided. Error A voltage sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and voltage sensor value are provided.
Amperage Probe Traps Amperage probes measure the amount of current (in amperes) that is traversing critical components. Table 26-6. Amperage Probe Traps Trap ID Description Severity Cause Amperage Probe Normal 1202 Information A current sensor on the power supply for the specified system Sensor location: returned to a valid range after crossing a failure Chassis location:
Table 26-6. Amperage Probe Traps (continued) Trap ID Description Severity Cause Error A current sensor on the power supply for the specified system exceeded its failure threshold. The sensor location, chassis location, previous state, and current sensor value are provided. Error A current sensor in the specified system detected an error from which it cannot recover. The sensor location, chassis location, previous state, and current sensor value are provided.
Chassis Intrusion Traps Chassis intrusion traps are a security measure. Chassis intrusion means that someone is opening the cover to a system’s chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis. Table 26-7.
Redundancy Unit Traps Redundancy means that a system chassis has more than one of certain critical components. Fans and power supplies, for example, are so important for preventing damage or disruption of a computer system that a chassis may have "extra" fans or power supplies installed. Redundancy allows a second or nth fan to keep the chassis components at a safe temperature when the primary fan has failed. Redundancy is normal when the intended number of critical components are operating.
Table 26-8. Redundancy Unit Traps (continued) Trap ID Description Severity Cause Warning A redundancy sensor in the specified system detected that one of the components of the redundancy unit has failed but the unit is still redundant. The redundancy unit location, chassis location, and previous redundancy state are provided.
Power Supply Traps Power supply traps provide status and warning information for power supplies present in a particular chassis. Table 26-9. Power Supply Traps Trap ID Description Severity Cause Power Supply Normal 1352 Power supply returned to normal Sensor location: Chassis location: Information A power supply has been reconnected or replaced.
Table 26-9. Power Supply Traps (continued) Trap ID Description Severity Cause Power Supply Warning 1353 Power supply detected a Warning warning Sensor location: Chassis location: Previous state was: Power Supply type: If in configuration error state: Configuration error type: 714 Traps A power supply sensor has detected a warning condition.
Table 26-9. Power Supply Traps (continued) Trap ID Description Severity Cause Power Supply Failure 1354 Power supply detected a Error failure Sensor location: Chassis location: A power supply has been disconnected or has failed. The sensor location, chassis location, previous state, and additional information about the power supply event are provided.
Table 26-10. Memory Device Messages Trap ID Description 1403 Severity Memory device status is Warning Memory device location: Possible memory module event cause: 1404 Memory device status is Error Memory device location: Possible memory module event cause: Cause A memory device correction rate exceeded an acceptable value. The memory device status and location are provided.
Table 26-11. Fan Enclosure Traps Trap ID Description Severity Cause Fan Enclosure Insertion 1452 Fan enclosure inserted Information into system Sensor location: Chassis location: A fan enclosure has been inserted into the specified system. The sensor location and chassis location are provided. Fan Enclosure Removal 1453 Fan enclosure removed from system Warning A fan enclosure has been removed from the specified system.
Table 26-12. AC Power Cord Traps Trap ID Description Severity Cause AC Power Cord No Power Nonredundant 1501 AC power cord is not being monitored Sensor location: Chassis location: Information The AC power cord status is not being monitored. This occurs when a system’s expected AC power configuration is set to nonredundant. The sensor location and chassis location information are provided.
Table 26-13. Hardware Log Traps Trap ID Description Severity Cause Hardware Log Normal 1552 Log size is no longer near or at capacity Log type: Information The hardware log on the specified system is no longer near or at its capacity, usually as the result of clearing the log. The log type information is provided. Hardware Log Warning 1553 Log size is near or at capacity Warning The size of a hardware log on the specified system is near or at the capacity of the hardware log.
Table 26-14. Processor Device Status Traps Trap ID Description Severity Cause Processor Device Status Normal 1602 Information A processor sensor in the specified system transitioned back to a normal state. The sensor Sensor Location: location, chassis location, previous state and processor Chassis Location:
Table 26-14. Processor Device Status Traps (continued) Trap ID Description Severity Cause Error A processor sensor in the specified system is disabled, has a configuration error, or experienced a thermal trip. The sensor location, chassis location, previous state and processor sensor status are provided.
Table 26-15. Pluggable Device Traps (continued) Trap ID Description Severity Cause Pluggable Device Removal 1652 Device removed from system Information A device was removed from the specified system. The Device Location: device location, chassis location, and additional Chassis Location: are provided.
Table 26-16. Battery Traps Trap ID Description Severity Cause Battery Normal 1702 Battery sensor returned Information to a normal value Sensor Location: Chassis Location: Previous state was: A battery sensor in the specified system detected that a battery transitioned back to a normal state. The sensor location, chassis location, previous state, and battery sensor status are provided.
Table 26-16. Battery Traps (continued) Trap ID Description Severity Cause Battery Failure 1704 Battery sensor detected Critical a failure value Sensor Location: Chassis Location: A battery sensor in the specified system detected that a battery has failed. The sensor location, chassis location, previous state, and battery sensor status are provided.
RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section "Traps". The trap variables are sent in the order in which they are listed. Table 26-18.
Table 26-19.
Table 26-19. Enterprise-specific Traps (continued) Trap ID Name Description Severity 1005 alertDrscPower The RAC Critical Off has detected a system power state change to poweredoff Error RAC DRAC III detected a system power state change to power-off. 1006 alertDrscPower The RAC Information Error On has detected a system power state change to powered-on RAC DRAC III detected a system power state change to power-on.
Table 26-19. Enterprise-specific Traps (continued) Trap ID Name Description 1008 alertDrscBatt Low The RAC Minor Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes 1009 Information Status alertDrscTemp The RAC Temperature Normal probe has returned to a normal value RAC DRAC III temperature probe reading returned to normal.
Table 26-19. Enterprise-specific Traps (continued) Trap ID Name Description Severity Category Cause Supported by RAC Platform 1012 alertDrscVolt Normal The RAC voltage has returned to a normal value Information Error 1013 alertDrscVolt Warning The RAC Minor voltage probe has detected a warning value Error RAC voltage DRAC III probe reading exceeded warning threshold.
Table 26-19. Enterprise-specific Traps (continued) Trap ID Name Description 1016 alertDrscSEL Critical The RAC Critical has detected a new event in the System Event Log with Severity: Critical 1017 alertDrscSEL The RAC 80 system percentFull event log is 80% full 1018 1019 730 Severity Category Cause Supported by RAC Platform Error RAC All detected a new system event log with critical severity (detailed log info is in drsAlert Message varbind).
Table 26-19. Enterprise-specific Traps (continued) Trap ID Name Description Severity Category Cause 1020 alertDrscSEL Normal The RAC Information Error has detected a new event in the System Event Log with Severity: Normal Supported by RAC Platform RAC All detected a new system event log with normal severity (detailed log info is in drsAlert Message varbind).
Table 26-20.
Table 26-20.
Table 26-20.
Table 26-20.
Traps
Storage Management Alert Reference 27 Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up. If you stop the Disk Management Service, then alert monitoring and logging stops.
Viewing Alerts Storage Management generates alerts that are added to the Windows application alert log and to the Server Administrator Alert log. To view these alerts in Server Administrator: 1 Select the System object in the tree view. 2 Select the Logs tab. 3 Select the Alert subtab. NOTE: You can also view these alerts in the Windows Event Viewer. Every alert consists of the following: • Severity — Shows the severity of alert. • Date and Time — Date and time when Storage Management logged the alert.
The alert severity levels are as follows: Table 27-1. Storage Management Alert Severity Alert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation. Warning/Non-critical A component requires attention.
The Windows SNMP service must be configured to forward the SNMP traps to the target system or application. When forwarding to an application, the application should also be configured to receive the SNMP traps. The IT Assistant application is already configured to receive the SNMP traps generated by Storage Management. See your Windows operating system documentation for information on configuring the operating system to forward SNMP traps.
Viewing SNMP Traps SNMP traps that are generated by Storage Management can be viewed in any standard SNMP-compatible enterprise management console. These traps are defined in the Storage Management MIB. These traps correspond to the alerts documented in the “Alert Descriptions and Corrective Actions” section. For more information on the MIB and its structure, as well as a change history of the SNMP traps, see the "Introduction" section.
Storage Management Alert Reference
Standard Data Type Definitions A This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib, dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
Variables with Data Types of State Capabilities and State Capabilities Unique Variables with definitions of StateCapabilities or StateCapabilitiesUnique are integers representing a series of bit definitions. They are NOT enumerations and should be treated as bit fields. The value is passed as a decimal value. The decimal value should be converted to hex and the appropriate bits should be parsed from hex.
Table A-3. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled. unknown(1) The object’s state is unknown. enabled(2) The object’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The object is not ready. enableAndNotReady(6) The object is enabled and not ready. Table A-4.
Dell Status Data Types Status data types include DellStatus, DellStatusRedundancy, and DellStatusProbe. Table A-5. Dell Status Variable Name: DellStatus Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s status is unknown. ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical. critical(5) The object’s status is critical (failure).
Table A-7. Dell Status Probe Variable Name: DellStatusProbe Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The status of the object is unknown. ok(3) The status of the object is OK. nonCriticalUpper(4) The object is at the noncritical upper limit. CriticalUpper(5) The object is at the critical upper limit. nonRecoverableUpper(6) The object is at the nonrecoverable upper limit.
Full Dates Variable Name: DellDateName Data Type: DisplayString DisplayString (SIZE (25)) Full dates are defined in the ASCII format: yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm are the minutes, and ss are the seconds. uuuuuu is the number of microseconds, and +fff or -fff is the offset from UTC in minutes. For example, Friday, October 31, 2001, at 6:05:19 PM CST would be represented as 20011031180519.000000-360.
B SNMP Sample Output This sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB). Values are shown for each object identifier (OID) in the Instrumentation MIB Version Group, the Systems Management Software Group, the System State Group, the Chassis Information Table, and Event Log Table. The data is from a Dell™ PowerEdge™ 2650 system. Walk .1.3.6.1.4.1.674.10892 Community: 'public') (Agent: 'SERVER01', .iso.
1.3.6.1.4.1.674.10892.1.100.10.0 = '2.2.0' 1.3.6.1.4.1.674.10892.1.100.11.0 = 0 1.3.6.1.4.1.674.10892.1.100.12.0 = 1 1.3.6.1.4.1.674.10892.1.100.13.0 = 'Dell Inc.' 1.3.6.1.4.1.674.10892.1.200.10.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.200.10.1.2.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.3.1 = 2 1.3.6.1.4.1.674.10892.1.200.10.1.4.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.5.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.6.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.7.1 = '\03' 1.3.6.1.4.1.674.
1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.25.1 '\03\03\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.26.1 '\02\02\02\02' = 1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 1.3.6.1.4.1.674.10892.1.200.10.1.28.1 '\03\03\03\03' = 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.42.1 = 3 1.3.6.1.4.1.
1.3.6.1.4.1.674.10892.1.300.10.1.13.1 = 289 1.3.6.1.4.1.674.10892.1.300.10.1.14.1 = 4 1.3.6.1.4.1.674.10892.1.300.10.1.15.1 = 'SERVER01' 1.3.6.1.4.1.674.10892.1.300.10.1.16.1 '20050513095213.000000-360' = 1.3.6.1.4.1.674.10892.1.300.10.1.17.1 '20050513100052.000000-360' = 1.3.6.1.4.1.674.10892.1.300.10.1.18.1 the value' = 'Please set 1.3.6.1.4.1.674.10892.1.300.10.1.19.1 the value' = 'Please set 1.3.6.1.4.1.674.10892.1.300.10.1.20.1 the value' = 'Please set 1.3.6.1.4.1.674.10892.1.300.
1.3.6.1.4.1.674.10892.1.300.10.1.36.1 = 480 1.3.6.1.4.1.674.10892.1.300.10.1.37.1 = 1 1.3.6.1.4.1.674.10892.1.300.10.1.38.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.39.1 = 2 1.3.6.1.4.1.674.10892.1.300.10.1.44.1 = 0 1.3.6.1.4.1.674.10892.1.300.10.1.45.1 = 0 1.3.6.1.4.1.674.10892.1.300.40.1.1.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 = 1 1.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 = 8 1.3.6.1.4.1.674.10892.1.300.40.1.4.1.1 = 2 1.3.6.1.4.1.674.10892.1.300.40.1.5.1.
SNMP Sample Output
Index Numerics BIOS Group tables, 383 1403, 716 BIOS Setup Control Group, 383 variable values, 409 1404, 716 1602, 720 1603, 720 C 1604, 721 Change, 657 1651, 721 Change Management Group, 657 1652, 722 1653, 722 A Application, 660 Application Group, 660 B BIOS Group BIOS Setup Control Table, 383 Diskette Control Table, 404 IDE Control Table, 402 Network Interface Control Table, 406 Parallel Port Control Table, 396 SCSI Control Table, 394 Serial Port Control Table, 398 USB Control Table, 400 Cha
Generic Device Table, 292 Keyboard Device Table, 262 Memory Device Mapped Address Table, 289 Memory Device Table, 281 PCI Device Configuration Space Table, 298 PCI Device Table, 295 Pointing Device Table, 260 Processor Device Table, 265 variable values, 317 COO Schedule Number Table, 447 COO Service Contract Table, 438 COO Support Information Table, 454 COO Trouble Ticket Table, 456 COO Warranty Table, 442 Cost of Ownership Table, 427 Cost of Ownership tables, 427 Device removed from system, 722 D data t
Inventory, 657 O Inventory Group, 657 Operating System Group, 663 Memory Table, 123 Operating System Table, 121 L Local Response Agent Group LRA Action Table, 422 LRA Global Settings, 419 LRA Global Settings Table, 420 variable values, 424 Local Response Agent Group tables, 419 Logical Devices Group, 641 M Memory device correction rate crossed a warning threshold, 716 Memory device ECC Correctable error count crossed a warning threshold, 716 Memory Group Physical Memory Tables, 359 variable values, 367
Voltage Probe Table, 156 Power Group tables, 149 Processor Device Status Traps, 719 Processor sensor detected a failure value, 721 Processor sensor detected a warning value, 720 Processor sensor returned to a normal state, 720 SNMP introduction to, 38 SNMP MIB OIDs, 40 SNMP security, 41 SNMP traps, 42 SNMP basic terminology fields, 31-32 managed object, 31 MIB, 31 SNMP, 30 variable, 31 SNMP support, configuring, 739 R Redundant Memory Unit Table, 371 Remote Access Group Remote Access Table, 468 Remote SNM
name, 46, 48 preferred protocol, 47 supported protocol, 47 version number name, 46 U User Security Table, 215, 219 V T Thermal Group Cooling Device Table, 199 Cooling Unit Table, 197 Temperature Probe Table, 205 variable values, 211 trap variables, 692 current status, 693 data, 693 message, 692 previous status, 693 system, 692 table index OID, 692 variable names capability, 33 settings, 33 state, 33 status, 33 Viewing SNMP traps, 741 traps, 699 AC power cord traps, 717 amperage probe traps, 708 chassis
Index