SNMP Reference Guide

SNMP Sample Output 749
B
SNMP Sample Output
This sample output from the Simple Network Management Protocol (SNMP)
covers the first four groups of the Instrumentation management information
base (MIB). Values are shown for each object identifier (OID) in the
Instrumentation MIB Version Group, the Systems Management Software
Group, the System State Group, the Chassis Information Table, and Event
Log Table. The data is from a Dell™ PowerEdge™ 2650 system.
Walk .1.3.6.1.4.1.674.10892 (Agent: 'SERVER01',
Community: 'public')
.iso.org.dod.internet.private.enterprises.dell.server3
1.3.6.1.4.1.674.10892.1.1.1.0 = 5
1.3.6.1.4.1.674.10892.1.1.2.0 = 3
1.3.6.1.4.1.674.10892.1.1.3.0 = 0
1.3.6.1.4.1.674.10892.1.100.1.0 = 'Server
Administrator'
1.3.6.1.4.1.674.10892.1.100.2.0 = '5.3.0'
1.3.6.1.4.1.674.10892.1.100.3.0 = 4522
1.3.6.1.4.1.674.10892.1.100.4.0 = 'Management
software for Dell systems.'
1.3.6.1.4.1.674.10892.1.100.5.0 = 1
1.3.6.1.4.1.674.10892.1.100.6.0 = 1
1.3.6.1.4.1.674.10892.1.100.7.0 = 'No Updates'
1.3.6.1.4.1.674.10892.1.100.8.0 =
'https://1.2.3.4:1311'
1.3.6.1.4.1.674.10892.1.100.9.0 = 'en_US'