User's Manual

omconfig: Managing Components Using the Instrumentation Service 125
Table 4-12. omconfig chassis remoteaccess config=user id=<user id>
dracusergroup=custom/omconfig mainsystem remoteaccess
config=user id=<user id> dracusergroup=custom
name=value pair 1 name=value pair 2 name=value pair 3 Description
config=user
(continued)
id=user id
dracusergroup=
custom
logindrac= true |
false
configuredrac=
true | false
configure users=
true | false
clearlogs= true |
false
executeservercom
mands= true |
false
accessconsoleredir
= true | false
accessvirtualmedia
= true | false
testalerts= true |
false
true/false: Enables/disables
logging into DRAC.
true/false: Enables/disables
configuration of DRAC.
true/false: Enables/disables
configuration of users.
true/false: Enables/disables
log clearance.
true/false: Enables/disables
execution of server
commands.
true/false: Enables/disables
access to console
redirection.
true/false: Enables/disables
access to virtual media.
true/false: Enables/disables
test alerts.
Table 4-13. omconfig chassis remoteaccess config=user id=<user id>
extipmiusergroup=custom/omconfig mainsystem remoteaccess config=
user id=<user id> extipmiusergroup=custom
name=value pair 1 name=value pair 2 name=value pair 3 Description
config=user
(continued)
id=user id
extipmiusergroup=
custom
NOTE: extipmiusergroup
user group is available only
on Dell xx0x modular
systems.
loginidrac= true |
false
configureidrac=
true | false
true/false:
Enables/disables
logging into iDRAC6.
true/false:
Enables/disables
configuration of
iDRAC6.