Users Guide

Server Administrator Services 81
Properties
Subtab: Memory
Under the Properties tab, you can view memory redundancy status, memory
array attributes, total capacity of the memory arrays, details of memory arrays,
memory device details, and memory device status.
NOTE: If a system with spare bank memory enabled enters a redundancy lost
state, it may not be apparent which memory module is the cause. If you cannot
determine which Dual In-line Memory Module (DIMM) to replace, see the switch to
spare memory bank detected log entry in the ESM system log to find which memory
module failed.
Alert Management
Subtabs: Alert Actions | SNMP Traps
Under the Alert Management tab, you can:
View current alert actions settings and set the alert actions that you want
to be performed in the event that a memory module returns a warning or
failure value.
View current SNMP trap alert thresholds and set the alert threshold levels
for memory modules. The selected traps are triggered if the system
generates a corresponding event at the selected severity level.
Network
Click the Network object to manage your system's NICs. Server Administrator
monitors the status of each NIC present in your system to ensure continuous
remote connection. Dell OpenManage Server Administrator reports FCoE
and iSoE capabilities of the NICs. Also, NIC teaming details are reported if
they are already configured on the system. Two or more physical NICs can be
teamed into a single logical NIC, to which an administrator can assign an IP
address. Teaming can be configured using NIC vendor tools. For example,
Broadcom - BACS. If one of the physical NICs fails, the IP address remains
accessible because it is bound to the logical NIC rather than to a single
physical NIC. If Team Interface is configured, the detailed team properties
are displayed. The relation between physical NICs and Team Interface and
vice-versa is also reported, if these physical NICs are members of the Team
Interface.
book.book Page 81 Tuesday, March 6, 2012 6:13 PM