Users Guide

Server Administrator Services 89
View current SNMP trap alert thresholds and set the alert threshold levels
for temperature probes. The selected traps are triggered if the system
generates a corresponding event at the selected severity level.
NOTE: You can set minimum and maximum temperature probe threshold values for
an external chassis to whole numbers only. If you attempt to set either the minimum or
maximum temperature probe threshold value to a number that contains a decimal,
only the whole number before the decimal place is saved as the threshold setting.
Voltages
Click the Voltages object to manage voltage levels in your system. Server
Administrator monitors voltages across critical components in various chassis
locations in the monitored system. The Voltages object action window can
have the following tabs, depending on the user's group privileges: Properties
and Alert Management.
Properties
Subtab: Voltage Probes
Under the Properties tab, you can view the current readings and status of
your system's voltage probes and configure minimum and maximum values
for voltage probe warning threshold.
NOTE: Some voltage probe fields differ according to the type of firmware your
system has: BMC or ESM. Some threshold values are not editable on
BMC-based systems.
Alert Management
Subtabs: Alert Actions | SNMP Traps
Under the Alert Management tab, you can:
View current alert actions settings and set the alert actions that you want
to be performed in the event that a system voltage sensor returns a
warning or failure value.
View current SNMP trap alert thresholds and set the alert threshold levels
for voltage sensors. The selected traps are triggered if the system generates
a corresponding event at the selected severity level.