CIM Reference Guide

58 CIM_LogicalElement
Range1InputVoltageLow Indicates the low voltage in millivolts of input
voltage range 1 for this power supply. A value of
0 denotes unknown.
uint32
Range1InputVoltageHigh Indicates the high voltage in millivolts of input
voltage range 1 for this power supply. A value of
0 denotes unknown.
uint32
ActiveInputVoltage Indicates which input voltage range is currently
in use. Range 1, range 2, or both can be
specified using the values 3, 4, or 5, respectively.
If the supply is not drawing power, a value of 6
(neither) can be specified. This information is
necessary in the case of an uninterruptible
power supply (UPS), a subclass of power supply.
Values for the ActiveInputVoltage property are:
1 - Other
2 - Unknown
3 - Range 1
4 - Range 2
5 - Both range 1 and range 2
6 - Neither range 1 nor range 2
uint16
TotalOutputPower Represents the total output power of the power
supply in milliwatts. A value of 0 denotes that
the power output is unknown.
uint32
PMCapable Indicates the Power Monitoring capability. Boolean
Table 3-20. CIM_PowerSupply Properties
(continued)
Class Name: CIM_PowerSupply
Parent Class: CIM_LogicalDevice
Property Description Data
Typ e