omconfig: Managing Components Using the Instrumentation Service 123
NOTE: The options ipv4idrac, ipv6idrac, and macidrac are deprecated.
omconfig chassis info or omconfig mainsystem info
Use the omconfig chassis info or omconfig mainsystem info command to
enter an asset tag name and a chassis name for the system. For a Blade
systems, enter asset tag names for modular components as well. Table 4-7
shows the valid parameters for the command.
powerbutton=
enable | disable
NA true: Enables the Power button on the
system.
false: Disables the Power button on the
system.
config=sysname NA Sets the name of the system.
config=syspower NA Sets the system power information.
config=servicetag NA Sets the system service tag information.
config=
remoteaccessipv4
NA Sets the remote access IPv4 information.
config=
remoteaccessipv6
NA Sets the remote access IPv6 information.
config=
remoteaccessmac
NA Sets the remote access MAC address.
config=ipv4idrac Sets IPv4 DRAC information.
config=ipv6idrac Sets IPv6 DRAC information.
config=macidrac NA Sets the DRAC’s MAC address.
config=
ambienttemp
NA Sets the system temperature in centigrade.
security=modify NA Allows you to modify the LCD text.
security=view NA Provides read-only access to the LCD text.
security=disabled NA Provides limited access to the LCD text.
remoteindication
=true
NA LCD flashes when the system detects an
active remote session.
Table 4-6. omconfig chassis frontpanel or omconfig mainsystem frontpanel
(continued)