Reference Guide

Storage Management Message Reference 113
2124 Redundancy
normal
OK / Normal /
Informational
Cause: Data
redundancy has been
restored to a virtual disk
or an enclosure that
previously suffered a
loss of redundancy.
This alert is for
informational purposes.
Action: None
Clear Alert
Number:
Alert 2124
is a clear
alert for
alerts 2122
and 2123.
Related
Alert
Number:
None
LRA
Number:
None
1304
2125 Controller
cache
preserved for
missing or
offline virtual
disk
Warning /
Non-critical
Cause: Virtual disk
controller was
disconnected, during
I/O operation.
Action: Import foreign
disks, if any. Check if
the enclosure
containing the virtual
disk is disconnected
from the controller.
Clear Alert
Number:
2186, 2240
Related
Alert
Number:
None
LRA
Number:
None
1203
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP