Reference Guide

128 Storage Management Message Reference
2161 Dedicated hot
spare
unassigned
OK / Normal /
Informational
Cause: A physical disk
that was assigned as a
hot spare has been
unassigned and is no
longer functioning as a
hot spare. The physical
disk may have been
unassigned by a user or
automatically
unassigned by Storage
Management. Storage
Management unassigns
hot spares that have
been used to rebuild
data. Once data is
rebuilt onto the hot
spare, the hot spare
becomes a member of
the virtual disk and is
no longer assigned as a
hot spare. You need to
assign a new hot spare
to maintain data
protection in this
situation. On the
CERC SATA1.5/6ch,
and CERC SATA1.5/2s
controllers, if you use
another application
such as the BIOS to
include a hot spare in a
virtual disk, then
Storage Management
unassigns the physical
disk as a hot spare.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers