Reference Guide

Storage Management Message Reference 149
2203 A dedicated
hot spare
failed.
Warning /
Non-critical
Cause: The controller is
unable to communicate
with a disk that is
assigned as a dedicated
hot spare. The disk may
have failed or been
removed. There may
also be a bad or loose
cable.
Action: Check if the
disk is healthy and that
it has not been
removed. Check the
cables. If necessary,
replace the disk and
reassign the hot spare.
Clear Alert:
None
Related
Alert
Number:
2048
LRA
Number:
2070
903
2204 A dedicated
hot spare has
been removed.
OK / Normal /
Informational
Cause: The controller is
unable to communicate
with a disk that is
assigned as a dedicated
hot spare. The disk may
have been removed.
There may also be a bad
or loose cable.
Action: Check if the
disk is healthy and that
it has not been
removed. Check the
cables. If necessary,
replace the disk and
reassign the hot spare.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers