Reference Guide

Storage Management Message Reference 151
2207 The only hot
spare available
is a SAS disk.
SAS disks
cannot replace
SATA disks.
Warning /
Non-critical
Cause: The only
physical disk available
to be assigned as a hot
spare is using SAS
technology. The
physical disks in the
virtual disk are using
SATA technology.
Because of this
difference in
technology, the hot
spare cannot rebuild
data if one of the
physical disks in the
virtual disk fails.
Action: Add a SATA
disk that is large enough
to be used as the hot
spare and assign the
new disk as a hot spare.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2070
903
2210 Battery
requires
reconditioning.
Initiate the
battery learn
cycle.
Warning /
Non-critical
Cause: Battery is in
warn only mode and
requires reconditioning.
Action: Initiate the
battery learn cycle.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
1153
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers