Reference Guide

176 Storage Management Message Reference
2282 Hot spare
SMART
polling failed.
Critical /
Failure / Error
Cause: The controller
firmware attempted a
SMART polling on the
hot spare but was
unable to complete it.
The controller has lost
communication with
the hot spare.
Action: Check the
health of the disk
assigned as a hot spare.
You may need to replace
the disk and reassign
the hot spare. Make
sure the cables are
attached securely. See
the Dell OpenManage
Server Administrator
Storage Management
User’s Guide available
at support.dell.com, for
more information on
checking the cables.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2071
904
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers