Reference Guide

Storage Management Message Reference 177
2283 A redundant
path is broken.
Warning /
Non-critical
Cause: The controller
has two connectors that
are connected to the
same enclosure. The
communication path on
one connector has lost
connection with the
enclosure. The
communication path on
the other connector is
reporting this loss.
Action: Make sure the
cables are attached
securely and both
enclosure management
modules (EMMs) are
healthy. See the Cables
Attached Correctly
section for more
information on
checking the cables.
Clear Alert:
2284
Related
Alert: None
LRA
Number:
2070
903
2284 A redundant
path has been
restored.
OK / Normal /
Informational
Cause: This alert is
provided for
informational purposes.
Action: None
Clear Alert:
Alert 2284
is a clear
alert for
alert 2283.
Related
Alert: None
LRA
Number:
2071
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers