Reference Guide

182 Storage Management Message Reference
2296 An EMM has
been inserted.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
951
2297 An EMM has
been removed.
Critical /
Failure / Error
Cause: An EMM has
been removed.
Action: Reinsert the
EMM. See the
hardware documentatio
n for information
on replacing the EMM.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2091
954
2298 The enclosure
has a bad
sensor %1.
Warning /
Non-critical
Cause: The enclosure
has a bad sensor. The
enclosure sensors
monitor the fan speeds,
temperature probes,
and so on. The
%1indicates a
substitution variable.
The text for this
substitution variable is
displayed with the alerts
in the alert log and can
vary depending on the
situation.
Action: See the
hardware
documentation for
more information.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2090
853
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers