Reference Guide

198 Storage Management Message Reference
2327 The NVRAM
has corrupted
data. The
controller is
reinitializing
the NVRAM.
Warning /
Non-critical
Cause: The nonvolatile
random access memory
(NVRAM) is corrupt.
This may occur after a
power surge, a battery
failure, or for other
reasons. The controller
is reinitializing the
NVRAM. The controller
properties reset to the
default settings after
the reinitialization is
complete.
None The controller is
taking the required
corrective action. If this
alert is generated often
(such as during each
reboot), replace the
controller.
Clear Alert:
None
Related
Alert
Number:
2266
LRA
Number:
2060
753
2328 The NVRAM
has corrupt
data.
Warning /
Non-critical
Cause: The NVRAM
has corrupt data. The
controller is unable to
correct the situation.
Action: Replace the
controller.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2060
753
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP