Reference Guide

214 Storage Management Message Reference
2356 SAS SMP
communicatio
ns error %1
Critical /
Failure / Error
Cause: The text for this
alert is generated by the
firmware and can vary
depending on the
situation. The reference
to SMP in this text
refers to SAS
Management Protocol.
Action: There may be a
SAS topology error. See
the hardware
documentation for
information on correct
SAS topology
configurations. There
may be problems with
the cables such as a
loose connection or an
invalid cabling
configuration. See the
Cables Attached
Correctly section for
more information on
checking the cables. See
the hardware
documentation for
information on correct
cabling configurations.
Verify that the firmware
is a supported version.
Clear Alert:
None
Related
Alert: None
LRA
Number:
2061
754
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers