Reference Guide

Storage Management Message Reference 223
2381 Controller
preserved
cache is
recovered.
OK / Normal /
Informational
Cause: This alert is
provided for
informational purposes.
Action: None
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
751
2382 An un-
supported
configuration
was detected.
The controller
does not
support
physical disks
of type SSD:
<Physical
DiskID>,
<controller-
ID>,
<connector-
ID>
Warning /
Non-critical
Cause: A physical disk
of media type SSD is
attached to a controller
that does not support
SSD disks.
Action: Replace the
unsupported physical
disk with a physical disk
of media type HDD.
Clear Alert:
None
Related
Alert: None
LRA
Number:
None
903
2383 The
Information
level set for the
hot spare
protection
policy is
violated for the
Virtual Disk.
OK / Normal /
Informational
Cause: The number of
physical disks you
specified for the hot
spare protection policy
is violated.
Action: Reassign the
number of hot spares as
specified in the
protection policy for
that RAID level.
Clear Alert:
2195
Related
Alert: None
LRA
Number:
None
1201
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers