Reference Guide

Storage Management Message Reference 67
NOTE: A, B, C and X, Y, Z in the following examples are variables representing the
storage object name or number.
Table 3-2. Message Format with Variables for Each Storage Object
Storage Object Message Variables
Controller Message Format: Controller A (Name)
Message Format: Controller A
For example, 2326 A foreign configuration has been detected:
Controller 1 (PERC 5/E Adapter)
NOTE: The controller name is not always displayed.
Battery Message Format: Battery X Controller A
For example, 2174 The controller battery has been removed: Battery
0 Controller 1
SCSI Physical
Disk
Message Format: Physical Disk X:Y Controller A, Connector B
For example, 2049 Physical disk removed: Physical Disk 0:14
Controller 1, Connector 0
SAS Physical
Disk
Message Format: Physical Disk X:Y:Z Controller A, Connector B
For example, 2049 Physical disk removed: Physical Disk 0:0:14
Controller 1, Connector 0
Virtual Disk Message Format: Virtual Disk X (Name) Controller A (Name)
Message Format: Virtual Disk X Controller A
For example, 2057 Virtual disk degraded: Virtual Disk 11
(Virtual Disk 11) Controller 1 (PERC 5/E Adapter)
NOTE: The virtual disk and controller names are not always displayed.
Enclosure: Message Format: Enclosure X:Y Controller A, Connector B
For example, 2112 Enclosure shutdown: Enclosure 0:2 Controller 1,
Connector 0
SCSI Power
Supply
Message Format: Power Supply X Controller A, Connector B,
Targ e t ID C
where "C" is the SCSI ID number of the enclosure management
module (EMM) managing the power supply.
For example, 2122 Redundancy degraded: Power Supply 1,
Controller 1, Connector 0, Target ID 6