Reference Guide

72 Storage Management Message Reference
2049 Physical disk
removed
Warning /
Non-critical
Cause: A physical disk
has been removed
from the disk group.
This alert can also be
caused by loose or
defective cables or by
problems with the
enclosure.
Action: If a physical disk
was removed from the
disk group, either replace
the disk or restore the
original disk. On some
controllers, a removed
disk has a red X for its
status. On other
controllers, a removed
disk may have an
Offline status or is
not displayed on the user
interface. Perform a
rescan after replacing or
restoring the disk. If a
disk has not been
removed from the disk
group, then check for
problems with the cables.
See the
online help
for
more information on
checking
the cables.
Ensure that the
enclosure is powered on.
If the problem persists,
check the enclosure
documentation for
further diagnostic
information.
Clear Alert
Number:
2052
Related
Alert
Number:
2054, 2057,
2056, 2076,
2079, 2081,
2083, 2129,
2202, 2204,
2270, 2292,
2299, 2369
LRA
Number:
2070
903
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers