Reference Guide

Storage Management Message Reference 73
2050 Physical disk
offline
Warning /
Non-critical
Cause: A physical disk
in the disk group is
offline. The user may
have manually put the
physical disk offline.
Action: Perform a
rescan. You can also
select the offline disk
and perform a Make
Online operation.
Clear Alert
Number:
2158
Related
Alert
Number:
2099, 2196
LRA
Number:
2070
903
2051 Physical disk
degraded
Warning /
Non-critical
Cause: A physical disk
has reported an error
condition and may be
degraded. The physical
disk may have reported
the error condition in
response to a SMART
Trip (Predictive
Failure).
Action: Replace the
degraded physical disk.
Yo u c a n i d e n t i f y w h i c h
disk is degraded by
locating the disk that
has a Yellow Triangle for
its status. Perform a
rescan after replacing
the disk.
Clear Alert:
None
Related
Alert
Number:
2094
LRA
Number:
2070
903
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP