Reference Guide

94 Storage Management Message Reference
2099
Cont.
Action: Although this
alert is provided for
informational purposes,
you may need to assign
a new hot spare to the
virtual disk.
2100 Temperature
exceeded the
maximum
warning
threshold
Warning /
Non-critical
Cause: The physical
disk enclosure is too
hot. A variety of factors
can cause the excessive
temperature. For
example, a fan may have
failed, the thermostat
may be set too high,
or the room temperature
may be too hot.
Action: Check for
factors that may cause
overheating. For
example, verify that the
enclosure fan is working.
You should also check
the thermostat settings
and examine whether
the enclosure is located
near a heat source. Make
sure the enclosure has
enough ventilation and
that the room
temperature is not too
hot. See the physical
disk enclosure
documentation for more
diagnostic information.
Clear Alert
Number:
2353
Related
Alert
Number:
2112
LRA
Number:
2090
1053
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related
Alert
Information
SNMP
Trap
Numbers