SNMP Reference Guide

Power Group 167
Amperage Probe Upper Noncritical Threshold
Amperage Probe Lower Noncritical Threshold
Amperage Probe Lower Critical Threshold
Name amperageProbeUpperNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.11
Description Defines the user-assigned value of the amperage probe’s upper
critical threshold.
Syntax DellSigned32BitRange
Access Read-write
Name amperageProbeLowerNonCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.12
Description Defines the user-assigned value of the amperage probe’s lower
noncritical threshold.
Syntax DellSigned32BitRange
Access Read-write
Name amperageProbeLowerCriticalThreshold
Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.13
Description Defines the value of the amperage probe’s lower
critical threshold.
Syntax DellSigned32BitRange
Access Read-only
book.book Page 167 Tuesday, February 28, 2012 2:19 PM