SNMP Reference Guide

690 Traps
Trap Variables
This section describes the variables that are sent to the management console
to provide additional information about a trap or alert generated by some
event on your system. The trap variables presented here apply to all
Instrumentation and RAC traps. Trap variables are sent in the order listed and
are reserved for use only in traps. When a varbind is created for a trap
variable, a zero is appended to the object ID (OID) to create the OID for
the varbind.
System
Table Index OID
Message
Variable Name alertSystem
Object ID 1.3.6.1.4.1.674.10892.1.5000.10.1
Description Identifies the system generating the alert.
Syntax DisplayString (SIZE (0..255))
Variable Name alertTableIndexOID
Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2
Description Specifies the object identifier for the index attribute in the
table that contains the object causing the alert. Uniquely
identifies the object causing the alert and can be used to
correlate different alerts caused by the same object.
Syntax OBJECT IDENTIFIER
Variable Name alertMessage
Object ID 1.3.6.1.4.1.674.10892.1.5000.10.3
Description Describes the alert.
Syntax DisplayString (SIZE (0..1024))