SNMP Reference Guide

Traps 697
Miscellaneous Traps
Table 27-2 lists Miscellaneous traps that inform you that certain alert systems
are up and working.
Table 27-2. Miscellaneous Traps
TrapID Description Severity Cause
System Up
1001 Server Administrator
startup complete
Information Server Administrator completed its
initialization.
Thermal Shutdown
1004 Thermal shutdown
protection has been
initiated
Error This message is generated when a
system is configured for thermal
shutdown due to an error event. If a
temperature sensor reading exceeds
the error threshold for which the
system is configured, the operating
system shuts down and the system
powers off. This event may also be
initiated on certain systems when a
fan enclosure is removed from the
system for an extended period of
time.
Automatic System Recovery
1006 Automatic System
Recovery (ASR) action was
performed
Action performed was:
<Action>
Date and time of action:
<Date and time>
Error This message is generated when an
automatic system recovery action is
performed due to a hung operating
system. The action performed and
the date and time of the action are
provided.
book.book Page 697 Tuesday, February 28, 2012 2:19 PM