SNMP Reference Guide

Traps 709
Redundancy Degraded
1305 Redundancy degraded
Redundancy unit: <Redundancy
location in chassis>
Chassis location: <Name of
chassis>
Previous redundancy state was:
<State>
Number of devices required for
full redundancy: <Number>
Warning A redundancy sensor in the
specified system detected
that one of the components
of the redundancy unit has
failed but the unit is still
redundant. The redundancy
unit location, chassis
location, and previous
redundancy state are
provided.
Redundancy Lost
1306 Redundancy lost
Redundancy unit: <Redundancy
location in chassis>
Chassis location: <Name of
chassis>
Previous redundancy state was:
<State>
Number of devices required for
full redundancy: <Number>
Warning or
Error
(depending
on the
number of
units that
are
functional)
A redundancy sensor in the
specified system detected
that one of the components
in the redundant unit has
been disconnected, has
failed, or is not present. The
redundancy unit location,
chassis location, and
previous redundancy state
are provided.
Table 27-8. Redundancy Unit Traps
(continued)
TrapID Description Severity Cause