SNMP Reference Guide

726 Traps
BMC Traps
The BMC monitors the system for critical events by communicating with
various sensors on the system board and by sending alerts and log events
when certain parameters exceed their preset thresholds. All of the traps
documented in this section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.3183.1.1.1.
1019 alertDrscSEL
100
percentFull
The RAC
system event
log is 100%
full
Major Status RAC
detected
system event
log is 100%
full.
All
1020 alertDrscSEL
Normal
The RAC
has detected
a new event
in the
System
Event Log
with
Severity:
Normal
Information Error RAC
detected a
new system
event log with
normal
severity
(detailed log
info is in
drsAlert
Message
varbind).
All
Table 27-20. BMC Traps
TrapID Description Severity
262402 Generic Critical Fan Failure Critical
262530 Generic Critical Fan Failure Cleared Information
131330 Under-Voltage Problem (Lower Critical - going low) Critical
131458 Under-Voltage Problem Cleared Information
131841 Generic Critical Voltage Problem Critical
Table 27-19. Enterprise-specific Traps
(continued)
TrapID Name Description Severity Category Cause Supporte
d by RAC
Platform
book.book Page 726 Tuesday, February 28, 2012 2:19 PM