User's Manual

Enclosures and Backplanes 155
Drop-down Menu Enclosure Tasks:
Enable Alarm (Enclosure)
Disable Alarm (Enclosure)
Set Asset Data
•Blink
Set Temperature Probe Values
Available Reports
To view a report:
1
Expand the
Storage
tree object to display the controller objects.
2
Expand a controller object.
3
Expand a
Connector
object.
4
Select the enclosure object.
5
Select the
Information/Configuration
subtab.
6
Select a report from the
Select Report
drop-down menu.
7
Click
Execute
.
Available Reports
View Slot Occupancy Report
Enable Alarm (Enclosure)
Does my enclosure support this feature? See Supported Features.
Use the Enable Alarm task to enable the enclosure alarm. When enabled, the
audible alarm sounds whenever the fault LED lights. This may occur to signal
events such as:
The enclosure temperature has exceeded the warning threshold.
A power supply, fan, or enclosure management module (EMM) has failed.
The split bus is not installed. (A split bus is indicated by a single triangle
symbol on the back of the enclosure.)