Dell OpenManage SNMP Reference Guide Version 7.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2012 Dell Inc.
Contents Notes, Cautions, and Warnings...................................................................................................2 1 Introduction................................................................................................................................11 Supported SNMP Versions.....................................................................................................................................11 Introduction to the SNMP Reference Guide.............................
System State Table..........................................................................................................................................33 List 1.................................................................................................................................................................33 List 2.................................................................................................................................................................
10 Thermal Group.......................................................................................................................143 Thermal Group Tables..........................................................................................................................................143 Cooling Unit Table..........................................................................................................................................143 Cooling Device Table...............................
Managed System Services Device Table......................................................................................................227 SD Card Unit Table.........................................................................................................................................228 SD Card Device Table....................................................................................................................................230 Device Group Variable Values...........................
COO Cost Event Log Table..............................................................................................................................335 COO Warranty Table......................................................................................................................................337 COO Lease Information Table........................................................................................................................339 COO Schedule Number Table..........................
Global Data Group.................................................................................................................................................415 Physical Devices Group........................................................................................................................................419 Controller Table..............................................................................................................................................419 Channel Table.........
27 SNMP Traps...........................................................................................................................527 Trap Variables.......................................................................................................................................................527 Understanding The Trap Description...................................................................................................................529 Understanding Trap Severity.......................
Variables with Data Types of State Capabilities and State Capabilities Unique..................................................567 Dell Status Data Types..........................................................................................................................................568 Dell Date...............................................................................................................................................................569 Full Dates...................................
1 Introduction This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage Version 7. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms. This introduction is divided into two sections. The first section, Introduction to the SNMP Reference Guide, explains the SNMP Reference Guide design.
identified by the SNMP OID 1.3.6.1.4.1.674.10892.1., where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1.
Section Topics MIB Group Numbers 20 Cluster Group — defines variables for systems that operate as a cluster 1800 21 Baseboard Management Controller Group — provides information 1900 about the Baseboard Management Controller (BMC) that may be present in your system.
Table 3. Server Administrator Field Replaceable Unit MIB Sections in This Guide Section Topic MIB Group Numbers 22 Field Replaceable Unit Group — provides information about field replaceable units that may be present in your system 2000 Server Administrator Storage Management MIB The Server Administrator Storage Management MIB (filename dcstorag.mib) provides storage management data that allows you to monitor the health of storage resources with SNMP management applications.
Dell Remote Access Controller Out-of-Band MIB The Dell Remote Access Controller Out-of-Band MIB (filename dellRAC.mib) provides management data that allows you to monitor the Chassis Management Controller. This MIB also contains information on RAC legacy alerting. The following table describes each Dell RAC Out-of-Band group and lists the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 6.
to the capabilities of the object that the user can select from and activate if desired. Capability settings allow users of the server administrator to predetermine how an object behaves under specific conditions. Settings are the conditions of a manageable object that determine what happens when a certain value is detected in a component. For example, a user can set the upper critical threshold of a temperature probe to 75 degrees Celsius.
, uUIDchassisIndex Table 10. UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 11. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only Table 12. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
1. BIOS Setup Control Group — This section explains the purpose of the MIB group and summarizes the major features of the component groups. 2. BIOS Group Tables — If there is more than one SNMP table for a group, this section lists all of the tables. For this BIOS group example, there are eight tables listed. In each section, double-clicking any table on the list takes you to that table.
events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155. The Server Administrator MIB conforms to the SMIv1 standard. SNMP is a systems management standard originally designed for network management. SNMP manages much more than networks. Information Technology (IT) professionals use SNMP for monitoring and managing computer systems and the various components and peripherals supported by their systems. SNMP standards are defined by the Internet Engineering Task Force (IETF).
INTERNET(1) MGMT(2) MIB(1) EXPERIMENTA L(3) PRIVATE(4) ENTERPRISES( 1) DELL (674) SNMPv2(6) In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674. The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values. SNMP Security SNMP version 1 has a very limited security mechanism.
SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Dell OpenManage SNMP Version 7.2 2 This section contains information added or updated for the current release. What’s New in This Release • Added support for Enhanced Messaging (EEMI), which includes unique system identifiers (system service tag, chassis service tag, and system FQDN) and message identifier, (Message ID) for enhanced SNMP trap varbinds. You can associate an event to the respective server using the unique system identifiers.
– Added the following tables for Trap on Traditional and Enhanced Varbinds. SNMP Traps: Traditional Varbinds: * alertSystem * alertTableIndexOID * alertMessage * alertCurrentStatus * alertPreviousStatus * alertData Enhanced Varbinds: * alertMsgID * alertSystemFQDN * alertServiceTag * alertChassisServiceTag • Added support for an additional feature — DIMM ranking, in Memory Module.
• Temperature Statistics Traps 25
Instrumentation MIB Version Group 3 The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software. The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table.
Syntax DellUnsigned8BitRange Access Read-only 28
Systems Management Software Group 4 The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports.
Table 17. Systems Management Software Build Number Name systemManagementSoftwareBuildNumber Object ID 1.3.6.1.4.1.674.10892.1.100.3 Description Defines the build number of the systems management software. Syntax DellUnsigned16BitRange Access Read-only Table 18. Systems Management Software Description Name Name systemManagementSoftwareDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.100.4 Description Defines the description of the systems management software.
Table 22. Systems Management Software URL Name Name systemManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10892.1.100.8 Description Defines the universal resource locator (URL) of the systems management software. Syntax DisplayString (SIZE (0..1024)) Access Read-only Table 23. Systems Management Software Language Name Name systemManagementSoftwareLanguageName Object ID 1.3.6.1.4.1.674.10892.1.100.9 Description Defines the language of the systems management software.
Table 27. Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.13 Description Defines the manufacturer of the systems management software. Syntax DellString Access Read-only Systems Management Software Variable Values This section includes definitions of server administrator-specific variable values used in this section. Table 28.
System State Group 5 The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes. System State Group Table The System State Group defines objects in the System State MIB table.
• systemStateCoolingUnitStatusCombined • systemStateACPowerSwitchStatusCombined • systemStateRedundantMemoryUnitStatusCombined • systemStateProcessorDeviceStatusCombined • systemStateBatteryStatusCombined • systemStateSDCardUnitStatusCombined • systemStateSDCardDeviceStatusCombined List 2 Variables that provide health status of each component in associated subsystem in chassis: • systemStatePowerSupplyStatusDetails • systemStateVoltageStatusDetails • systemStateAmperageStatusDetails • s
Description Defines the System State Table entry. Syntax SystemStateTableEntry Access Not accessible Index systemStatechassisIndex Table 33. System State Chassis Index Name systemStatechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 34. System State Global System Status Name systemStateGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 37. System State Power Unit State Details Name systemStatePowerUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5 Description Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power unit. The first byte returned represents the state of the first power unit, the second byte returned represents the state of the second power unit, and so on.
Access Read-only Table 41. System State Power Supply Status Combined Name systemStatePowerSupplyStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.9 Description Defines the status of all power supplies in this chassis. Syntax DellStatus Access Read-only Table 42. System State Power Supply Status Details Name systemStatePowerSupplyStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.10 Description Defines the status of all power supplies in this chassis.
Table 45. System State Voltage Status Details Name systemStateVoltageStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.13 Description Defines the status of all voltage probes in this chassis. Syntax Octet String (Size (1..128)) Access Read-only Table 46. System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14 Description Defines the state of all current probes in this chassis.
Table 49. System State Cooling Unit State Details Name statesystemStateCoolingUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit. The first byte returned represents the state of the first cooling unit, the second byte returned represents the state of the second cooling unit, and so on.
Access Read-only Table 53. System State Cooling Device Status Combined Name systemStateCoolingDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.21 Description This attribute defines the cooling device status of all cooling devices in this chassis. The results is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only Table 54.
Syntax DellStatus Access Read-only Table 57. System State Temperature Status Details Name systemStateTemperatureStatusDetailsly Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.25 Description Defines the status of all temperature probes in this chassis. The first byte returned represents the status of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on. Syntax Octet String (Size(1..128) Access Read-on Table 58.
Syntax Octet String (Size(1..128) Access Read-only Table 61. System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device.
Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on. Syntax Octet String (Size(1..128)) Access Read-only Table 65. System State AC Power Switch Status Redundancy Name systemStateACPowerSwitchStatusRedundancy Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Access Read-only Table 69. System State AC Power Cord Status Details Name systemStateACPowerCordStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.37 Description Defines the individual status of all AC power cords for any AC power switches in this chassis. The first byte returned represents the status of the first AC power cord, the second byte returned represents the status of the second AC power cord, and so on. Syntax Octet String (SIZE(1..128)) Access Read-only Table 70.
Access Read-only Table 73. System State Event Log Status Name systemStateEventLogStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41 Description Defines the overall status of this chassis (ESM) event log. Syntax DellStatus Access Read-only Table 74. System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42 Description Defines the combined status of all power units of this chassis.
Description Lists the status of each cooling unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling unit. The first byte returned represents the status of the first cooling unit, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128)) Access Read-only Table 78. System State AC Power Switch Status Combined Name systemStateACPowerSwitchStatusCombined Object ID 1.3.6.1.
Syntax Octet String (Size(1..128)) Access Read-only Table 82. System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50 Description Defines the combined status of all processor devices of this chassis. Syntax DellStatus Access Read-only Table 83. System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 86. System State SD Card Unit Status Combined Name systemStateSDCardUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.54 Description Defines the combined status of all SD Card units of this chassis. Syntax DellStatus Access Read-only Table 87. System State SD Card Unit Status List Name systemStateSDCardUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.55 Description Lists the status of each SD Card unit of this chassis.
Chassis Information Group 6 The Chassis Information Group objects provide information about the modular chassis in which a blade system resides. NOTE: This Chassis information is only available for modular/blade systems. For Rack and Tower systems, the information is empty. Currently there is just one object under the Chassis Information Group. Table 90. Chassis Service Tag Name chassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.1.2.1.0 This attribute defines the service tag of the enclosing chassis.
Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.10.1 Description Defines the chassis information table entry. Syntax ChassisInformationTableEntry Access Not accessible Index chassisIndexChassisInformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1 Description Defines the index (one-based) of this chassis. The first chassis is numbered one.
Chassis Parent Index Reference Name chassisparentIndexReference Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the index (one-based) of the parent chassis of this chassis, if any. A zero (0) means that this chassis is the parent of all other chassis managed by the Server Administrator. Syntax DellObjectRange Access Read-only Chassis Type Name chassisType Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.6 Description Defines the chassis type.
Chassis Asset Tag Name Name chassisAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.10 Description Defines the user-assigned asset tag name for this chassis. Syntax DisplayString (SIZE (0..10)) Access Read-write Chassis Service Tag Name Name chassisServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.11 Description Defines the service tag name for this chassis. Syntax DisplayString (SIZE (0..7)) Access Read-only Chassis ID Name chassisID Object ID 1.3.6.1.4.1.674.10892.1.
Chassis System Name Name chassisSystemName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.15 Description Defines the system name of this chassis. Syntax DellString Access Read-only Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defines the boot time of this system. Syntax DellDateName Access Read-only Chassis System Date Name Name chassisSystemDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.21 Description Defines the status of the connection from the system chassis to an expansion chassis.
Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25 Description Defines the readings and settings of the LED control hardware in the chassis. Syntax DellLEDControlSettings (See Front-Panel LED Control Settings) Access Read-write Chassis Hard-Drive (HD) Fault Clear Control Capabilities Name chassisHDFaultClearControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis Lock Present Name chassisLockPresent Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.30 Description Specifies whether a chassis lock is present on the chassis. Syntax DellBoolean Access Read-only Chassis Host Control Capabilities Unique Name chassishostControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.31 Description Defines the capabilities of the host control object.
Chassis Watchdog Control Expiry Time Capabilities Unique Name chassiswatchDogControlExpiryTimeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.35 Description Defines the capabilities of the watchdog expiry timer object. Syntax DellWatchDogTimerCapabilities (See Watchdog Timer Capabilities) Access Read-only Chassis Watchdog Control Expiry Time Name chassiswatchDogControlExpiryTime Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Syntax DellPowerButtonControlSettings (See Power Button Control Settings) Access Read-write Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40 Description Defines the name of the chassis reseller. Syntax DisplayString (SIZE (0..128)) Access Read-only Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.41 Description Defines the chassis reseller contact information name.
Access Read-only Chassis NMI Button Control Settings Unique Name chassisNMIButtonControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.45 Description Defines the current reading and allows setting of the NMI button control hardware. Syntax DellNMIButtonControlSettings (See NMI Button Control Settings) Access Read-write Chassis System Properties Name chassisSystemProperties Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.46 Description Defines the properties of the system.
Access Read-only UUID Table These objects comprise the server administrator definitions for the Universal Unique Identifier (UUID). Table 92. UUID Table Name uUIDTable Object ID 1.3.6.1.4.1.674.10892.1.300.20 Description Defines the UUID table. Syntax SEQUENCE OF UUIDTableEntry Access Not accessible Table 93. UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry.
Table 96. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 97. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE(16)) Access Read-only POST Log Table This section defines attributes for the power-on self-test (POST) log.
Table 100. POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 101. POST Log Record Index Name postLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.2 Description Defines the record number (one-based) of the POST log. Syntax DellUnsigned32BitRange Access Read-only Table 102.
Table 105. POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines format of the POST log. Syntax DellLogFormat (See Log Format) Access Read-only Event Log Table Table 106. Event Log Table Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.40 Description Defines the Event Log Table. Syntax SEQUENCE OF EventLogTableEntry Access Not accessible Table 107. Event Log Table Entry Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.
Description Defines the record index of the event log. Syntax DellUnsigned32BitRange Access Read-only Table 110. Event Log State Capabilities Unique Name eventLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.3 Description Defines the capabilities of the object that is writing the event log. Syntax DellStateCapabilitiesLogUnique Access Read-only Table 111. Event Log State Settings Unique Name eventLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.
Description Defines the severity of the event log record. Syntax DellStatus Access Read-only Status Mandatory Table 115. Event Log Date Name Name eventLogDateName Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8 Description Defines the date and time of the event log record. Syntax DellDateName Access Read-only Status Mandatory System BIOS Table This table lists objects that define the system’s basic input/output system (BIOS). Table 116.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 119. System BIOS Index Name systemBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2 Description Defines the index (one-based) of the system BIOS of this object. Syntax DellObjectRange Access Read-only Table 120. System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.
Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 124. System BIOS Release Date Name Name systemBIOSReleaseDateName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.7 Description Defines the release date of the system BIOS. Syntax DellDateName Access Read-only Table 125. System BIOS Version Name Name systemBIOSVersionName Object ID 1.3.6.1.4.1.674.10892.
Table 128. System BIOS Manufacturer Name Name systemBIOSManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.11 Description Defines the system BIOS manufacturer’s name. Syntax DellString Access Read-only Table 129. System BIOS Characteristics Name systemBIOSCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.12 Description Defines characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Syntax Bit 19 EDD (Enhanced Disk Drive) Specification is supported Bit 20 Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is supported Bit 21 Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in, 360 RPM) is supported Bit 22 Int 13h - 5.25 in / 360 KB Floppy Services are supported Bit 23 Int 13h - 5.25 in /1.2MB Floppy Services are supported Bit 24 Int 13h - 3.5 in / 720 KB Floppy Services are supported Bit 25 Int 13h - 3.5 in / 2.
Bit 1 USB Legacy is supported Bit 2 AGP is supported Bit 3 I2O boot is supported Bit 4 LS-120 boot is supported Bit 5 ATAPI ZIP Drive boot is supported Bit 6 1394 boot is supported Bit 7 Smart Battery supported Syntax DellUnsigned8BitRange Access Read-only Table 131. System BIOS Characteristics Ext 2 Name systemBIOSCharacteristicsExt2 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.14 Description Defines additional characteristics of the system BIOS.
Description Defines the Firmware Table entry Syntax FirmwareTableEntry Access Not accessible Index firmwarechassisIndex , firmwareIndex Table 134. Firmware Chassis Index Name firmwarechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 135. Firmware Index Name firmwareIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
Description Defines the status of the firmware. Syntax DellStateSettings Access Read-only Table 139. Firmware Size Name firmwareSize Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.6 Description Defines the image size of the firmware in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned16BitRange Access Read-only Table 140. Firmware Type Name firmwareType Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7 Description Defines the type of the firmware.
Access Read-only Table 144. Firmware Version Name Name firmwareVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11 Description Defines the version name of the firmware. Syntax DellString Access Read-only Intrusion Table The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of a computer is removed. Table 145. Intrusion Table Name intrusionTable Object ID 1.3.6.1.4.1.674.10892.1.300.
Table 148. Intrusion Index Name intrusionIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.2 Description Defines the index of the intrusion objects in this subgroup. Syntax DellObjectRange Access Read-only Table 149. Intrusion State Capabilities Name intrusionStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.3 Description Defines the capabilities of the intrusion object. Syntax DellStateCapabilities Access Read-only Table 150.
Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Table 154. Intrusion Location Name Name intrusionLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.8 Description Defines the location name of the intrusion object in this subgroup. Syntax DellString Access Read-only Baseboard Table This table lists objects that define the baseboard of a system. Table 155. Baseboard Table Name baseBoardTable Object ID 1.3.6.1.4.1.674.10892.1.300.
Table 158. Baseboard Index Name baseBoardIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.2 Description Defines the index (one-based) of the base board. Syntax DellObjectRange Access Read-only Table 159. Baseboard State Capabilities Name baseBoardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.3 Description Defines the state capabilities of the baseboard. Syntax DellStateCapabilities Access Read-only Table 160.
Description Defines the type of the baseboard. Syntax DellBaseBoardType Access Read-only Table 164. Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8 Description Defines the name of the type of baseboard. Syntax DellString Access Read-only Table 165. Baseboard Location Name Name baseBoardLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.9 Description Defines the location name of the baseboard.
Table 169. Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13 Description Defines the baseboard service tag name. Syntax DellString Access Read-only Table 170. Baseboard Piece Part ID (PPID) Name Name baseBoardPiecePartIDName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.14 Description Defines the baseboard PPID. Syntax DellString Access Read-only Table 171. Baseboard Asset Tag Name Name baseBoardAssetTagName Object ID 1.3.6.1.4.1.
Table 174. Chassis Type Variable Name : DellChassisType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The chassis type is not one of the following: unknown(2) The chassis type is unknown. desktop(3) The chassis type is a desktop. lowProfileDeskto p(4) The chassis type is a low-profile desktop. pizzaBox(5) The chassis type is a pizza box. miniTower(6) The chassis type is a minitower. tower(7) The chassis type is a tower. portable(8) The chassis type is a portable.
Possible Data Values Meaning of Data Value unknown(2) The status of the chassis connection is unknown. ok(3) The status of the chassis connection is OK. failure(4) The status of the chassis connection is failure. Table 176. Fan Control Capabilities Variable Name : DellFanControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The fan’s capabilities are unknown. lowSpeedCapable( 2) The fan can be set to low speed.
Possible Data Values Meaning of Data Value none(0) The hard drive has no fault LED capabilities. unknownCapabilit The hard-drive fault LED capabilities are unknown. ies(1) enableCapable(2) The hard-drive fault LED can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable( The hard-drive fault LED can indicate not ready. 4) resetCapable(8) The hard-drive fault LED can be reset. Table 180.
NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning components. When enabled, the blinking lights help administrators locate the problem chassis. Table 182. Chassis Identification Control Settings Variable Name : DellChassisIdentifyControlSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The chassis identification control’s state is unknown..
manualRebootWith The operator can reboot without operating system outOSShut shutdown. downCapable(32) manualPowerOffWi The operator can power off with operating system thOSShutd shutdown. ownCapable(64) manualPowerOffWi The operator can power off without operating thoutOSSh system shutdown. utdownCapable(12 8) manualPowerCycle The operator can power cycle with operating WithOSShu system shutdown. tdownCapable(256 ) manualPowerCycle The operator can power cycle without operating WithoutOS system shutdown.
automaticNotific Watchdog controls can be set to notify capable ationCapable(4) host automaticWatchDo Watchdog controls can be set to function gTimerCapable(8) automatically. automaticPowerOf Watchdog controls can be set to automatically fCapable(16) power off host. automaticAllExce Watchdog controls can be set to automatically ptNotificationCa perform all functions except notification capable. p able(27) automaticFullyCa Watchdog controls can be set to automatically pable(31) perform all functions.
enableCapable(2) The power button can be enabled (online) or disabled (offline). Table 189. Power Button Control Settings Variable Name : DellPowerButtonControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The power button has no settings capabilities. unknown(1) The power button settings are unknown. enabled(2) The power button state is enabled. disabled(4) The power button state is disabled. Table 190.
Table 193. Baseboard Type Variable Name : DellBaseBoardType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The baseboard type is unknown. other(2) The baseboard type is not one of the following types. serverBlade(3) The baseboard type is a server blade. connectivitySwit The baseboard type is a connectivity switch. ch(4) systemManagement The baseboard type is a system management Module(5) module. processorModule( The baseboard type is a processor module.
Data Type: Integer Possible Data Values Meaning of Data Value other(1) The firmware type is other than following values. unknown(2) The firmware type is unknown. systemBIOS(3) The firmware type is System BIOS embeddedSystemMa The firmware type is Embedded System nagementContro Management Controller. ller(4) powerSupplyParal The firmware type is Power Supply Paralleling lelingBoard(5) Board. systemBackPlane( The firmware type is System (Primary) Backplane.
boardIsHostingBo This baseboard is a hosting board. ard(1) boardRequiresDau This baseboard requires at least one daughter ghterBoard (2) board or auxiliary card. boardIsRemovabl e(4) This baseboard is removable. boardIsReplaceab This baseboard is replaceable. le(8) boardIsHotSwappa This baseboard is hot swappable.
Operating System Group 7 The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system. The following objects describe the fields for Operating System Group. Operating System Memory Table Table 197. Operating System Memory Table Name operatingSystemMemoryTable Object ID 1.3.6.1.4.1.674.10892.1.400.20 Description Defines the Operating System Memory Table.
Access Read-only Table 201. Operating System Memory State Settings Name operatingSystemMemoryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.3 Description Defines the state and allows the setting of the operating system memory. Syntax DellStateSettings Access Read-write Table 202. Operating System Memory Status Name operatingSystemMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.4 Description Defines the status of the operating system memory.
Table 206. Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8 Description Defines the available page file memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 207. Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.9 Description Defines the total virtual memory size in kilobytes.
System Resource Group 8 The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes System Resource Group Tables that track variables such as the owner, ports, system memory, interrupts, and direct memory access.
Table 211. System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 212. System Resource Map Index Name systemResourceMapIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.2 Description Defines the index of system resource maps in this chassis. Syntax DellObjectRange Access Read-only Table 213.
Description Defines the type of this system map. Syntax DellSystemResourceMapType (System Resource Map Type) Access Read-only System Resource Owner Table Table 217. System Resource Owner Table Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20 Description Defines the System Resource Owner Table. Syntax SEQUENCE OF SystemResourceOwnerTableEntry Access Not accessible Table 218. System Resource Owner Table Entry Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.
Table 221. System Resource Owner State Capabilities Name systemResourceOwnerStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.3 Description Defines the capabilities of this system resource owner. Syntax DellStateCapabilities Access Read-only Table 222. System Resource Owner State Settings Name systemResourceOwnerStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4 Description Defines the state settings of this system resource owner.
Description Defines the description name of the system resource owner. Syntax DellString Access Read-only Table 227. System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.9 Description Defines the associated system resource owner interface instance in this chassis. Syntax DellObjectRange Access Read-only System Resource Input/Output (I/O) Port Table Table 228.
Table 231. System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2 Description Defines the index (one-based) of the system resource I/O ports in this chassis. Syntax DellObjectRange Access Read-only Table 232. System Resource I/O Port State Capabilities Name systemResourceIOPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.3 Description Defines the capabilities of the system resource I/O port.
Description Defines the share disposition of the system resource I/O port. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 237. System Resource I/O Port Starting Address Name systemResourceIOPortStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.8 Description Defines the 64 bits of the starting address of the system resource I/O port. Syntax DellUnsigned64BitRange Access Read-only Table 238.
Table 241. System Resource Memory Chassis Index Name systemResourceMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 242. System Resource Memory Index Name systemResourceMemoryIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2 Description Defines the index of system resource memory in this chassis. Syntax DellObjectRange Access Read-only Table 243.
Syntax DellObjectRange Access Read-only Table 246. System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.7 Description Defines the share disposition of the system resource memory. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 247. System Resource Memory Starting Address Name systemResourceMemoryStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.
Access Not accessible Table 251. System Resource Interrupt Table Entry Name systemResourceInterruptTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.50.1 Description Defines the System Resource Interrupt Table entry. Syntax SystemResourceInterruptTableEntry Access Not accessible Index systemResourceInterruptchassisIndex , systemResourceInterruptIndex Table 252. System Resource Interrupt Chassis Index Name systemResourceInterruptchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.
Access Read-write Table 256. System Resource Interrupt Status Name systemResourceInterruptStatus Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.5 Description Defines the status of this system resource interrupt. Syntax DellStatus Access Read-only Table 257. System Resource Interrupt Owner Index Reference Name systemResourceInterruptOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.6 Description Defines the index for the associated system resource owner in this chassis.
Table 261. System Resource Interrupt Trigger Name systemResourceInterruptTrigger Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10 Description Defines the interrupt trigger of the system resource interrupt. Syntax DellResourceInterruptTrigger (Resource Interrupt Trigger) Access Read-only System Resource Direct Memory Access (DMA) Table Table 262. System Resource Direct Memory Access (DMA) Table Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.
Access Read-only Table 266. System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA. Syntax DellStateCapabilities Access Read-only Table 267. System Resource DMA State Settings Name systemResourceDMAStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.4 Description Defines the state and setting of this system resource DMA.
Table 271. System Resource DMA Maximum Transfer Size Name systemResourceDMAMaximumTransferSize Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.8 Description Defines the maximum size of a memory transfer in bytes for the system resource DMA. Syntax DellUnsigned32BitRange Access Read-only Table 272. System Resource DMA Transfer Width Name systemResourceDMATransferWidth Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.9 Description Defines the transfer width of the system resource DMA.
typeIsUnknown(2) The interface type is unknown. typeIsInternal(3) The interface type is internal. typeIsISA(4) The interface type is an Industry Standard Architecture (ISA) bus. typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus. typeIsMCA(6) The interface type is a microchannel architecture (MCA) bus. typeIsTurboChannel(7) The interface type is a turbo-channel bus. Table 276.
interruptIsLatched(2) The interrupt type is latched. Table 279. Resource Interrupt Trigger Variable Name: DellResourceInterruptTrigger Data Type: Integer Possible Data Values Meaning of Data Value interruptIsActiveWhenL ow(1) The interrupt trigger is active on a low signal. interruptIsActiveWhenH igh(2) The interrupt trigger is active on a high signal. Table 280.
9 Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes. NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems that have a fixed, nonredundant power supply installed.
Index powerUnitchassisIndex, powerUnitIndex Table 284. Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 285. Power Unit Index Name powerUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.2 Description Defines the index of the power unit in this chassis. Syntax DellObjectRange Access Read-only Table 286.
Table 289. Power Supply Count for Redundancy Name powerSupplyCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.6 Description Defines the total number of power supplies required for this power unit to have redundancy. Syntax DellString Access Read-only Table 290. Power Unit Name Name powerUnitName Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.7 Description Defines the name of the power unit in this chassis. Syntax DellString Access Read-only Table 291.
Table 294. Power Supply Chassis Index Name powerSupplychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 295. Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Table 296.
Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Table 300. Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerSupplyType (Power Supply Type Definitions) Access Read-only Table 301. Power Supply Location Name Name powerSupplyLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
Access Read-only Table 305. Power Supply Configuration Error Type Name powerSupplyConfigurationErrorType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.12 Description Defines the type of configuration error reported by the power supply sensor. Syntax DellPowerSupplyConfigurationErrorType (Power Supply Configuration Error Type) Access Read-only Table 306. Power Supply Power Monitor Capable Name powerSupplyPowerMonitorCapable Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
Index voltageProbechassisIndex, voltageProbeIndex Table 310. Voltage Probe Chassis Index Name voltageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 311. Voltage Probe Index Name voltageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.2 Description Defines the index of voltage probes in this chassis. Syntax DellObjectRange Access Read-only Table 312.
Table 315. Voltage Probe Reading Name voltageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6 Description Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Table 316. Voltage Probe Type Name voltageProbeType Object ID 1.3.6.1.4.1.674.10892.1.
Table 320. Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.11 Description Defines the user-assigned value of the voltage probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 321. Voltage Probe Lower Noncritical Threshold Name voltageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. Syntax DellVoltageDiscreteReading Access Read-only Amerage Probe Table Table 326. Amerage Probe Table Name amperageProbeTable Object ID 1.3.6.1.4.1.
Access Read-only Table 330. Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.3 Description Defines the capabilities of the amperage probe. Syntax DellStateCapabilities Access Read-only Table 331. Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.4 Description Defines the state and settings of the amperage probe. Syntax DellStateSettings Access Read-write Table 332.
Access Read-only Table 334. Amperage Probe Type Name amperageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.7 Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Table 335. Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.8 Description Defines the location name of the amperage probe in this chassis. Syntax DellString Access Read-only Table 336.
Table 339. Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.12 Description Defines the user-assigned value of the amperage probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 340. Amperage Probe Lower Critical Threshold Name amperageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
AC Power Switch Table Table 344. AC Power Switch Table Name aCPowerSwitchTable Object ID 1.3.6.1.4.1.674.10892.1.600.40 Description Defines the AC Power Switch Table. Syntax SEQUENCE OF ACPowerSwitchTableEntry Access Not accessible Table 345. AC Power Switch Table Entry Name aCPowerSwitchTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.40.1 Description Defines the AC Power Switch Table entry.
Syntax DellACPowerSwitchCapabilities Access Read-only Table 349. AC Power Switch Settings Name aCPowerSwitchSettings Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.4 Description Defines the settings of this AC power switch. Syntax DellACPowerSwitchSettings Access Read-write Table 350. AC Power Switch Redundancy Status Name aCPowerSwitchRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.5 Description Defines the redundancy status of this AC power switch.
Table 354. AC Power Switch Status Name aCPowerSwitchStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.9 Description Defines the status of this AC power switch. Syntax DellStatus Access Read-only AC Power Cord Table Table 355. AC Power Cord Table Name aCPowerCordTable Object ID 1.3.6.1.4.1.674.10892.1.600.42 Description Defines the AC Power Cord Table. Syntax SEQUENCE OF ACPowerCordTableEntry Access Not accessible Table 356.
Access Read-only Table 359. AC Power Cord State Capabilities Name aCPowerCordStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.3 Description Defines the capabilities of this AC power cord. Syntax DellACPowerCordStateCapabilities Access Read-only Table 360. AC Power Cord State Settings Name aCPowerCordStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.4 Description Defines the settings of this AC power cord.
Battery Table Table 364. Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Table 365. Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.1 Description Defines the Battery Table Entry. Syntax BatteryTableEntry Access Not accessible Index batteryChassisIndex , batteryIndex Table 366.
Table 369. Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-write Table 370. Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Description Defines the status of the battery. Syntax DellStatus Access Read-only Table 371. Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.
Table 374. Power Usage Table Entry Name powerUsageTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.60.1 Description Defines the Power Usage Table Entry. Syntax PowerUsageTableEntry Access Not accessible Index powerUsageChassisIndex , powerUsageIndex Table 375. Power Usage Chassis Index Name powerUsageChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 376.
Table 379. Power Usage Status Name powerUsageStatus Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.5 Description Defines the status of the power usage information. Syntax DellStatus Access Read-only Table 380. Power Usage Entity Name Name powerUsageEntityName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.6 Description Defines the name of the entity associated with this power usage information. Syntax DellString Access Read-only Table 381.
Table 384. Power Usage Peak Watts Start Date Name Name powerUsagePeakWattsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.10 Description Defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute. Syntax DellDateName Access Read-only Table 385. Power Usage Peak Watts Reading Date Name Name powerUsagePeakWattsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Table 389. Power Usage Idle Power Name powerUsageIdlePower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.15 Description Defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only Table 390. Power Usage Max Potential Power Name powerUsageMaxPotentialPower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.16 Description Defines the maximum potential power (in Watts) of the system.
Table 394. Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.20 Description Defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. Syntax DellUnsigned32BitRange Access Read-only Table 395. Power Usage Peak Headroom Name powerUsagePeakHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Access Read-only Table 399. Power Profile Index Name powerProfileIndex Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.2 Description Defines the index (one-based) of the power profile information. Syntax DellObjectRange Access Read-only Table 400. Power Profile Supported Profiles Name powerProfileSupportedProfiles Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.3 Description Defines the supported power profiles. Syntax DellPowerProfileType Access Read-only Table 401.
Table 404. Power Profile Custom Memory Management Capabilities Name powerProfileCustomMemoryManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.7 Description Defines the custom memory power and performance management capabilities that are available for the Custom power profile. Syntax DellMemoryPowerPerformanceManagementType Access Read-only Table 405. Power Profile Custom Memory Management Capabilities Name powerProfileCustomMemoryManagementSetting Object ID 1.3.6.1.4.1.674.
unknown(1) The power supply’s capabilities are unknown. onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The power supply’s capabilities are not ready. Table 409. Power Supply State Settings Unique Variable Name: DellPowerSupplyStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The power supply’s capabilities are unknown.
powerSupplyTypeIsLinear(3) The power supply type is a linear power supply. powerSupplyTypeIsSwitching(4) The power supply type is a switching power supply. powerSupplyTypeIsBattery(5) The power supply type is a battery. powerSupplyTypeIsUPS(6) The power supply type is an uninterruptable power supply. powerSupplyTypeIsConverter(7) The power supply type is a power converter power supply. powerSupplyTypeIsRegulator(8) The power supply type is a regulator power supply.
Table 413. Voltage Probe Type Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsOther(1) The voltage probe type is not one of the following: voltageProbeTypeIsUnknown(2) The voltage probe type is unknown (not known or not monitored). voltageProbeTypeIs1Point5Volt (3) The voltage probe type is a 1.5-volt (V) probe. voltageProbeTypeIs3Point3Volt (4) The voltage probe type is a 3.3-V probe.
amperageProbeTypeIsOther(1) The amperage probe type is not one of the following: amperageProbeTypeIsUnknown(2) The amperage probe type is unknown (not known or not monitored). amperageProbeTypeIs1Point5Volt(3) The amperage probe type is a 1.5-ampere (A) probe. amperageProbeTypeIs3Point3volt(4) The amperage probe type is a 3.3-A probe. amperageProbeTypeIs5Volt(5) The amperage probe type is a 5-A probe. amperageProbeTypeIsMinus5Volt(6) The amperage probe type is a –5-A probe.
Table 417. AC Power Switch Capabilities Variable Name: DellACPowerSwitchCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknownCapabilities(1) The AC power switch’s capabilities are unknown. inputSourceCord1NoReturnCapable(2) Input source is AC power cord 1, with no return. inputSourceCord1ReturnCapable(4) Input source is AC power cord 1, with return. inputSourceCord2NoReturnCapable(8) Input source is AC power cord 2, with no return.
onlineCapable(2) The AC power cord can be disabled (offline) or enabled (online). notReadyCapable(4) The AC power cord’s capabilities are not ready. Table 421. AC Power Cord State Settings Variable Name: DellACPowerCordStateSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power cord’s state is unknown. online(2) The AC power cord’s state is disabled (offline) 0 or enabled (online) 1. notReady(4) The AC power cord’s state is not ready.
Table 424. Power Cap Setting Variable Name: DellPowerCapSetting Data Type: Integer Possible Data Values Meaning of Data Value disabled(0) Power cap is disabled. enabled(1) Power cap is enabled. Table 425. Power Profile Type Variable Name: DellPowerProfileType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Power profile type is Maximum Performance. osControl(2) Power profile type is OS control.
NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Memory power and performance management type is Maximum Performance. mhz1333(2) Memory power and performance is 1333 MHz. . mhz1067(4) Memory power and performance is 1067 MHz. mhz800(8) Memory power and performance is 800 MHz. minPower(16) Memory power and performance management type is Minimum Power. Table 428.
10 Thermal Group The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes.
Syntax TableEntry Access Read-only Table 432. Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units. Syntax DellObjectRange Access Read-only Table 433. Cooling Unit State Capabilities Name coolingUnitStateCapabilties Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.3 Description Defines the capabilities of the cooling unit. Syntax DellStateCapabilities Access Read-only Table 434.
Table 437. Cooling Unit Name Name coolingUnitName Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.7 Description Defines the cooling unit name in this chassis. Syntax DellString Access Read-only Table 438. Cooling Unit Status Name coolingUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.8 Description Defines the status of the cooling unit in this chassis. Syntax DellStatus Access Read-only Cooling Device Table Table 439. Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.
Access Read-only Table 442. Cooling Device Index Name coolingDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.2 Description Defines the index of cooling devices in this chassis. Syntax DellObjectRange Access Read-only Table 443. Cooling Device State Capabilities Name coolingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.3 Description Defines the capabilities of the cooling device. Syntax DellStateCapabilities Access Read-only Table 444.
Access Read-only Table 447. Cooling Device Type Name coolingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.7 Description Defines the cooling device type. Syntax DellCoolingDeviceType (Cooling Device Type) Access Read-only Table 448. Cooling Device Location Name Name coolingDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.8 Description Defines the location of the cooling device in this chassis. Syntax DellString Access Read-only Table 449.
Table 452. Cooling Device Lower Noncritical Threshold Name coolingDeviceLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.12 Description Defines the user-assigned value of the fan’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 453. Cooling Device Lower Critical Threshold Name coolingDeviceLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.13 Description Defines the value of the fan’s lower critical threshold.
Description Defines the probe capabilities of the cooling device. Syntax DellProbeCapabilities Access Read-only Table 458. Cooling Device Discrete Reading Name coolingDeviceDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.18 Description Defines the reading for a voltage probe of type coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute.
Access Read-only Table 462. Temperature Probe Index Name temperatureProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.2 Description Defines the index of temperature probes in this chassis. Syntax DellObjectRange Access Read-only Table 463. Temperature Probe State Capabilities Name temperatureProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.3 Description Defines the capabilities of the temperature probe. Syntax DellStateCapabilities Access Read-only Table 464.
Access Read-only Table 467. Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.7 Description Defines the temperature probe type. Syntax DellTemperatureProbeType (Temperature Probe Type) Access Read-only Table 468. Temperature Probe Location Name Name temperatureProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.8 Description Defines the location of the temperature probe in this chassis. Syntax DellString Access Read-only Table 469.
Table 472. Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.12 Description Defines the user-assigned value of the temperature probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 473. Temperature Probe Lower Critical Threshold Name temperatureProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Thermal Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 477. Cooling Device Type Variable Name: DellCoolingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther(1) The cooling device type is not one of the following: coolingDeviceTypeIsUnknown(2) The cooling device type is unknown (not known or not monitored). coolingDeviceTypeIsAFan(3) The cooling device type is a fan.
Table 479. Cooling Device Discrete Reading Variable Name: DellCoolingDeviceDiscreteReading . Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceIsGood(1) The cooling device discrete reading is good. coolingDeviceIsBad(2) The cooling device discrete reading is bad Table 480.
User Security Group 11 The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems. User Security Group Table The User Security Group defines objects in the User Security MIB table. The following object sets up the User Security Table: Table 482. User Security Table Name userSecurityTable Object ID 1.3.6.1.4.1.674.10892.1.
Table 485. User Security Index Name userSecurityIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.2 Description Defines the user security index. Syntax DellObjectRange Access Read-only Table 486. User Security User Name Name userSecurityUserName Object ID 1.3.6.1.4.1.674.10892.1.800.1.3 Description Defines the user security user name. Syntax DellSecurityString Access Read-only Table 487. User Security Control Name Name userSecurityControlName Object ID 1.3.6.1.4.1.674.10892.1.800.1.
Remote Flash BIOS Group 12 The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates on the system. Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table. Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table: Table 489. Remote Flash BIOS Table Name remoteFlashBIOSTable Object ID 1.3.6.1.4.1.674.
Table 492. Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system. Syntax DellObjectRange Access Read-only Table 493. Remote Flash BIOS State Capabilities Unique Name remoteFlashBIOSStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.3 Description Defines the capabilities of the remote BIOS update hardware on this system.
Table 497. Remote Flash BIOS Completion Code Name remoteFlashBIOSCompletionCode Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.7 Description Defines the completion code of the last BIOS update. Syntax DellRemoteFlashBIOSCompletionCode (Remote Flash BIOS Completion Code) Access Read-only Table 498. Remote Flash BIOS Minimum Contiguous Memory Name remoteFlashBIOSMinimumContiguousMemory Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.
canceled(8) The remote flash BIOS has been canceled. pending(16) The remote flash BIOS update is pending. other(32) The remote flash BIOS state/setting is not one of the previous values. Table 501.
13 Port Group The Port Group provides information about the different types of ports that may be present in your system. This management information base (MIB) group also provides information about the capabilities, states, and settings that are possible for each port.
, pointingPortIndex Table 504. Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 505. Pointing Port Index Name pointingPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.2 Description Defines the index of the pointing ports in this chassis. Syntax DellObjectRange Access Read-only Table 506.
Access Read-only Table 509. Pointing Port Security State Name pointingPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.10.6 Description Defines the security settings of the pointing port. Syntax DellPortSecurityState Access Read-only Table 510. Pointing Port Connector Type Name pointingPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.7 Description Defines the connector type of the pointing port.
Syntax IntegerKeyboardPortTableEntry Access Not accessible Table 514. Keyboard Port Table Entry Name keyboardPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1 Description Defines the Keyboard Port Table entry. Syntax KeyboardPortTableEntry Access Not accessible Index keyboardPortchassisIndex , keyboardPortIndex Table 515. Keyboard Port Chassis Index Name keyboardPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.
Table 518. Keyboard Port State Settings Name keyboardPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.4 Description Defines the state and settings of the keyboard port. Syntax DellStateSettings Access Read-only Table 519. Keyboard Port Status Name keyboardPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.5 Description Defines the status of the keyboard port. Syntax DellStatus Access Read-only Table 520.
Table 523. Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Table 524. Processor Port Table Name processorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.30 Description Defines the Processor Port Table. Syntax IntegerProcessorPortTableEntry Access Not accessible Table 525.
Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Table 528. Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port. Syntax DellStateCapabilities Access Read-only Table 529. Processor Port State Settings Name processorPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.
Syntax DellProcessorPortConnectorType (See Processor Port Connector Types) Access Read-only Table 533. Processor Port Name Name processorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.8 Description Defines name of the processor port. Syntax DellString Access Read-only Table 534. Processor Port BIOS Connector Type Name processorPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.9 Description Defines the BIOS connector type of the processor port.
Table 537. Memory Device Port Chassis Index Name memoryDevicePortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 538. Memory Device Port Index Name memoryDevicePortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.2 Description Defines the index of the memory device port in this chassis. Syntax DellObjectRange Access Read-only Table 539.
Table 542. Memory Device Port Security State Name memoryDevicePortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.6 Description Defines the security settings of the memory device port. Syntax DellPortSecurityState Access Read-only Table 543. Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7 Description Defines the connector type of the memory device port.
Table 547. Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any). Syntax DellUnsigned32BitRange Access Read-only Monitor Port Table Table 548. Monitor Port Table Name monitorPortTable Object ID 1.3.
Table 551. Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Table 552. Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port. Syntax DellStateCapabilities Access Read-only Table 553.
Table 556. Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port. Syntax DellMonitorPortConnectorTypes (See Monitor Port Connector Types) Access Read-only Table 557. Monitor Port Name Name monitorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.8 Description Defines the name of the monitor port. Syntax DellString Access Read-only Table 558.
Index sCSIPortchassisIndex , sCSIPortIndex Table 561. SCSI Port Chassis Index Name sCSIPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.1 Description Defines the index (one-based) of this chassis Syntax DellObjectRange Access Read-only Table 562. SCSI Port Index Name sCSIPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.2 Description Defines the index of the SCSI ports in this chassis. Syntax DellObjectRange Access Read-only Table 563.
Syntax DellStatus Access Read-only Table 566. SCSI Port Security State Name sCSIPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.6 Description Defines the security settings of the SCSI port. Syntax DellPortSecurityState Access Read-only Table 567. SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7 Description Defines the connector type of the SCSI port.
Description Defines the Parallel Port Table. Syntax IntegerParallelPortTableEntry Access Not accessible Table 571. Parallel Port Table Entry Name parallelPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1 Description Defines the Parallel Port Table entry. Syntax ParallelPortTableEntry Access Not accessible Index parallelPortchassisIndex , parallelPortIndex Table 572. Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.
Table 575. Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-write Table 576. Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5 Description Defines the status of the parallel port. Syntax DellStatus Access Read-only Table 577.
Table 580. Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9 Description Defines the pinout of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Table 581. Parallel Port Capabilities Unique Name parallelPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.10 Description Defines the capabilities of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Table 582.
Serial Port Table Table 585. Serial Port Name serialPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.80 Description Defines the Serial Port Table. Syntax IntegerSerialPortTableEntry Access Not accessible Table 586. Serial Port Table Entry Name serialPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1 Description Defines the Serial Port Table entry. Syntax SerialPortTableEntry Access Not accessible Index serialPortchassisIndex , serialPortIndex Table 587.
Table 589. Serial Port State Capabilities Name serialPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.3 Description Defines the capabilities of the serial port. Syntax DellStateCapabilities Access Read-only Table 590. Serial Port State Settings Name serialPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.4 Description Defines the state and settings of the serial port. Syntax DellStateSettings Access Read-write Table 591.
Table 594. Serial Port Name Name serialPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.8 Description Defines the name of the serial port. Syntax DellString Access Read-only Table 595. Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description Defines the maximum speed the serial interface can support in bits per second (bps). Syntax DellUnsigned32BitRange Access Read-only Table 596.
Universal Serial Bus (USB) Port Table Table 599. Universal Serial Bus (USB) Port Name uSBPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.90 Description Defines the USB Port Table. Syntax IntegerUSBPortTableEntry Access Not accessible Table 600. USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry. Syntax USBPortTableEntry Access Not accessible Index uSBPortchassisIndex , uSBPortIndex Table 601.
Syntax DellStateCapabilities Access Read-only Table 604. USB Port State Settings Name uSBPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4 Description Defines the state and settings of the USB port. Syntax DellStateSettings Access Read-write Table 605. USB Port Status Name uSBPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.5 Description Defines the state of the USB port. Syntax DellStatus Access Read-only Table 606.
Access Read-only Port Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 609. Pointing Port Connector Type Variable Name: DellPointingPortConnectorType Data Type :Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther( 1) The pointing port connector type is not one of the following: connectorPortTypeIsUnknow n(2) The pointing port connector type is unknown.
connectorPortTypeIsUnknown(2) The keyboard port connector type is unknown. connectorPortTypeIsMiniDIN(3) The keyboard port connector type is a mini DIN. connectorPortTypeIsMicroDIN(4) The keyboard port connector type is a MicroDIN. connectorPortTypeIsPS2(5) The keyboard port connector type is PS/2. connectorPortTypeIsInfrared(6) The keyboard port connector type is infrared. connectorPortTypeIsHPHIL(7) The keyboard port connector type is HP-HIL.
connectorPortTypeIsSIMM(3) The memory device port connector type is a single in-line memory module (SIMM). connectorPortTypeIsSIP(4) The memory device port connector type is a SIP. connectorPortTypeIsAChip(5) The memory device port connector type is a chip. connectorPortTypeIsDIP(6) The memory device port connector type is a dual in-line package (DIP). connectorPortTypeIsZIP(7) The memory device port connector type is a ZIP.
connectorPortTypeIsDIN68pin(5) The SCSI port connector type is a DIN 68-pin.
14 Device Group The Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID.
Syntax PointingDeviceTableEntry Access Not accessible Index pointingDevicechassisIndex , pointingDeviceIndex Table 617. Pointing Device Chassis Index Name pointingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 618. Pointing Device Index Name pointingDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.
Syntax DellStatus Access Read-only Table 622. Pointing Port Index Reference Name pointingPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.6 Description Defines the index to the pointing port in this chassis. Syntax DellObjectRange Access Read-only Table 623. Pointing Device Type Name pointingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.7 Description Defines the type of the pointing device.
Access Not accessible Index keyboardDevicechassisIndex , keyboardDeviceIndex Table 627. Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 628. Keyboard Device Index Name keyboardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2 Description Defines the index of the keyboard device for this chassis.
Access Read-only Table 632. Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis. Syntax DellStatus Access Read-only Table 633. Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.7 Description Defines the name of the keyboard type. Syntax DellString Access Read-only Table 634.
Index processorDevicechassisIndex , processorDeviceIndex Table 637. Processor Device Chassis Index Name processorDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 638. Processor Device Index Name processorDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.2 Description Defines the index of the processor device in this chassis.
Table 642. Processor Port Index Reference Name processorPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.6 Description Defines the index to the associated processor port in this chassis. Syntax DellObjectRange Access Read-only Table 643. Processor Device Type Name processorDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7 Description Defines the type of processor device. Syntax DellProcessorDeviceType (See Processor Device Type) Access Read-only Table 644.
Description Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 648. Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.12 Description Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 649.
Syntax DellString Access Read-only Table 653. Processor Device Core Count Name processorDeviceCoreCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17 Description Defines the number of processor cores detected for the processor device. Syntax DellUnsigned32BitRange Access Read-only Table 654. Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
Access Read-only Table 657. Processor Device Extended Capabilities Name processorDeviceExtendedCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21 Description This attribute defines extended capabilities of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Table 660. Processor Device Model Name Name processorDeviceModelName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24 Description Defines the model of the processor device. Syntax DellString Access Read-only Table 661. Processor Device Stepping Name Name processorDeviceSteppingName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.25 Description Defines the stepping of the processor device. Syntax DellString Access Read-only Processor Device Status Table Table 662.
Access Read-only Table 665. Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe. Syntax DellObjectRange Access Read-only Table 666. Processor Device Status State Capabilities Name processorDeviceStatusStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3 Description Defines the state capabilities of the processor device status probe.
Table 670. Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe. Syntax DellString Access Read-only Table 671. Processor Device Status Port Index Reference Name processorDeviceStatusPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.8 Description Defines the index (one-based) of the associated processor port in the same chassis.
Syntax DellObjectRange Access Read-only Table 675. Cache Device Index Name cacheDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2 Description Defines the index of the cache device in this chassis. Syntax DellObjectRange Access Read-only Table 676. Cache Device State Capabilities Name cacheDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.3 Description Description Defines the capabilities of the cache device.
Table 680. Cache Device Type Name cacheDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.7 Description Defines the type of cache device. Syntax DellCacheDeviceType (See Cache Device Type) Access Read-only Table 681. Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Cache Device Location) Access Read-only Table 682.
Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 686. Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Defines the current size of the cache device in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 687.
Syntax DellCacheDeviceECCType (See Cache Device ECC Type) Access Read-only Table 691. Cache Device Associativity Name cacheDeviceAssociativity Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.18 Description Defines the type of associativity in use by the cache device. Syntax DellCacheDeviceAssociativity (See Cache Device Associativity) Access Read-only Table 692. Cache Device Supported Type Name cacheDeviceSupportedType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.
Syntax MemoryDeviceTableEntry Access Not accessible Index memoryDevicechassisIndex , memoryDeviceIndex Table 696. Memory Device Chassis Index Name memoryDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 697. Memory Device Index Name memoryDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.2 Description Defines the index of the memory device in this chassis.
Syntax DellStatus Access Read-only Table 701. Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-only Table 702. Memory Device Type Name memoryDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7 Description Defines the type of the memory device.
Description Defines the bank location name of the memory device. Syntax DellString Access Read-only Table 706. Memory Device Type Details Name memoryDeviceTypeDetails Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11 Description Defines the detailed type of the memory device. Syntax DellMemoryDeviceTypeDetails (See Memory Device Type Details) Access Read-only Table 707. Memory Device Form Factor Name memoryDeviceFormFactor Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
Access Read-only Table 711. Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16 Description Defines the total number of bits, including ECC, used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Table 712. Memory Device Total Data Bus Width Name memoryDeviceTotalDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.17 Description Defines the total number of data bits used by the memory device.
Table 715. Memory Device Failure Modes Name memoryDeviceFailureModes Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20 Description Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK. It is a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks. Syntax DellMemoryDeviceFailureModes Access Read-only Table 716. Memory Device Manufacturer Name Name memoryDeviceManufacturerName Object ID 1.3.
Table 720. Memory Device Speed Name Name memoryDeviceSpeedName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25 Description This attribute defines the speed of the memory device in string format with units specified in string. Syntax DellString Access Read-only Table 721. Memory Device Rank Name memoryDeviceRank Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.26 Description 1100.0050.0001.0026 — This attribute defines the Rank of the memory device (DIMM). Zero indicates an unknown.
Index memoryDeviceMappedAddresschassisIndex , memoryDeviceMappedAddressIndex Table 724. Memory Device Mapped Address Chassis Index Name memoryDeviceMappedAddresschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 725. Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Access Read-only Table 729. Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address. Syntax DellObjectRange Access Read-only Table 730. Memory Device Mapped Address Row Position Name memoryDeviceMappedAddressRowPosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Access Read-only Table 734. Memory Device Mapped Address Ending Address Name memoryDeviceMappedAddressEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.11 Description Defines the physical ending address in KB of the memory device mapped address. Syntax DellUnsigned64BitRange Access Read-only Generic Device Table Table 735. Generic Device Table Name genericDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.70 Description Defines the Generic Device Table.
Description Defines the index of the generic device in this chassis. Syntax DellObjectRange Access Read-only Table 739. Generic Device State Capabilities Name genericDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.3 Description Defines the capabilities of the generic device. Syntax DellStateCapabilities Access Read-only Table 740. Generic Device State Settings Name genericDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.
Table 744. Generic Device Name Name genericDeviceName Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8 Description Defines the name of the generic device. Syntax DellString Access Read-only PCI Device Table Table 745. PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Description Defines the PCI Device Detail Table. Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible Table 746. PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.
Access Read-only Table 749. PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3 Description Defines the capabilities of the PCI device. Syntax DellStateCapabilities Access Read-only Table 750. PCI Device State Settings Name pCIDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.4 Description Defines the state of the PCI device. Syntax DellStateSettings Access Read-write Table 751.
Table 754. PCI Device Manufacturer Name Name pCIDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.8 Description Defines the name of the PCI device manufacturer. Syntax DellString Access Read-only Table 755. PCI Device Description Name Name pCIDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.9 Description Defines the descriptive name of the PCI device. Syntax DellString Access Read-only Table 756. PCI Device Speed Name pCIDeviceSpeed Object ID 1.3.
Table 759. PCI Device Configuration Space Table Entry Name pCIDeviceConfigurationSpaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1 Description Defines the PCI Device Configuration Table entry. Syntax PCIDeviceConfigurationSpaceTableEntry Access Not accessible Index pCIDeviceConfigurationSpacechassisIndex , pCIDeviceConfigurationSpaceIndex Table 760. PCI Device Configuration Space Chassis Index Name pCIDeviceConfigurationSpacechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.
Table 764. PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration. Syntax DellStatus Access Read-only Table 765. PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6 Description Defines the index number of PCI device that this configuration applies to. Syntax DellObjectRange Access Read-only Table 766.
Description Defines the common configuration space header of the PCI device. Syntax Octet String (SIZE(0.1025)) Access Read-only Network Device Table Table 770. Network Device Table Name networkDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.90 Description Defines the Network Device Table. Syntax SEQUENCE OF NetworkDeviceTableEntry Access Not accessible Table 771. Network Device Table Entry Name networkDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.90.
Table 774. Network Device Status Name networkDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.3 Description Defines the status of the network device. Syntax DellStatus Access Read-only Table 775. Network Device Connection Status Name networkDeviceConnectionStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.4 Description Defines the connection status of the network device. Syntax DellNetworkDeviceConnectionStatus (See Network Device Connection Status) Access Read-only Table 776.
Description Defines the service name of the network device. Syntax DellString Access Read-only Table 780. Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.9 Description Defines the path to the binary image of the driver for the network device. Syntax DellString Access Read-only Table 781. Network Device Driver Version Name Name networkDeviceDriverVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Access Read-only Table 785. Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.14 Description Defines the IP address of the DHCP server that was used to obtain the IP address of the network device if DHCP was used to configure the network device. Syntax IpAddress Access Read-only Table 786. Network Device Current MAC Address Name networkDeviceCurrentMACAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Table 790. Network Device PCI Function Number Name networkDevicePCIFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19 Description Defines the PCI function number of the network device. Syntax DellUnsigned8BitRange Access Read-only Table 791. Network Device IRQ Name networkDeviceIRQ Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.20 Description Defines the interrupt request number of the network device. Syntax DellUnsigned32BitRange Access Read-only Table 792.
Description Defines if TOE is enabled for the network device. Syntax DellBoolean Access Read-only Table 796. Network Device RDMA Capability Flags Name networkDeviceRDMACapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25 Description Defines the Remote Direct Memory Access (RDMA) capability flags of the network device. Syntax DellNetworkDeviceRDMACapabilityFlags (See Network Device RDMA Capability Flags) Access Read-only Table 797.
Managed System Services Device Table Table 800. Managed System Services Device Table Name Object ID 1.3.6.1.4.1.674.10892.1.1100.100 Description Defines the Managed System Services Device Table. Syntax Sequence of ManagedSystemServicesDeviceTable Access Not accessible Table 801. Managed System Services Device Table Entry Name managedSystemServicesDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1 Description Defines the managed system services device table entry.
Syntax DellStatus Access Read-only Table 805. Managed System Services Device Type Name managedSystemServicesDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.4 Description Defines the type of the managed system services device. Syntax DellManagedSystemServicesDeviceType (See Managed System Services Device Type) Access Read-only Table 806. Managed System Services Device Storage Present Name managedSystemServicesDeviceStoragePresent Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.
Syntax SdCardUnitTableEntry Access Not accessible Index sdCardUnitChassisIndex , sdCardUnitIndex Table 810. SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card unit. Syntax DellObjectRange Access Read-only Table 811. SD Card Unit Index Name sdCardUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.
Syntax DellStatusRedundancy Access Read-only Table 815. SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.6 Description Defines the total number of SD Card devices required for this SD Card unit to have full redundancy. Syntax DellObjectRange Access Read-only Table 816. SD Card Unit Name Name sdCardUnitName Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.7 Description Defines the name of the SD Card unit.
Access Not accessible Index sdCardDeviceChassisIndex , sdCardDeviceIndex Table 820. SD Card Device Chassis Index Name sdCardDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card device. Syntax DellObjectRange Access Read-only Table 821. SD Card Device Index Name sdCardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.2 Description Defines the index (one-based) of the SD Card device.
Access Read-only Table 825. SD Card Device Config Settings Name sdCardDeviceConfigSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6 Description Defines the configuration settings of the SD Card device. Syntax DellSDCardDeviceConfigSettings Access Read-only Table 826. SD Card Device Location Name Name sdCardDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.7 Description Defines the location of the SD Card device. Syntax DellString Access Read-only Table 827.
Table 830. SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.11 Description Defines the index to the associated SD Card unit if the SD Card device is part of a SD Card unit. Syntax DellObjectRange Access Read-only Table 831. SD Card Device Card Available Storage Size Name sdCardDeviceCardAvailableStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.
deviceTypeIsATouch Pad(7) Device type is a touch pad. Table 834. Processor Device Status State Variable Name:DellProcessorDeviceStatusState Data Type:Integer Possible Data Values Meaning of Data Value other(1) Processor device type is not one of the following: unknown(2) Device type is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device has its BIOS disabled. idle(6) Device is idle. Table 835.
deviceTypeIsMathP The processor device type is a math processor. rocessor(4) deviceTypeIsDSP(5 The processor device type is a digital signal ) processor. deviceTypeIsAVide The processor device is a video processor. oProcessor(6) Table 837. Processor Upgrade Information Variable Name:DellProcessorUpgradeInformation Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) The upgrade device type is not one of the following: processorUpgradeI Upgrade device type is unknown.
processorUpgradeI Upgrade is by Socket 939. sBySocket939(18) processorUpgradeI Upgrade is by Socket mPGA604. sBySocketmPGA604( 19) processorUpgradeI Upgrade is by Socket LGA771. sBySocketLGA771(2 0) processorUpgradeI Upgrade is by Socket LGA775. sBySocketLGA775(2 1) processorUpgradeI Upgrade is by Socket S1. sBySocketS1(22) processorUpgradeI Upgrade is by Socket AM2. sBySocketAM2(23) processorUpgradeI Upgrade is by Socket F (1207). sBySocketF(24) processorUpgradeI Upgrade is by Socket LGA1366.
deviceFamilyIsPen The processor family is Pentium Pro. tiumPro(12) deviceFamilyIsPen The processor family is Pentium II. tium2(13) deviceFamilyIsPen The processor family is Pentium MMX. tiumMMX(14) deviceFamilyIsCel The processor family is Celeron. eron(15) deviceFamilyIsXeo The processor family is Xeon. n(16) deviceFamilyIsPen The processor family is Pentium III. tium3(17) deviceFamilyIsPen The processor family is Pentium III Xeon.
deviceFamilyIsPow The processor family is Power PC 604. erPC604(36) deviceFamilyIsPow The processor family is Power PC 620. erPC620(37) deviceFamilyIsPow The processor family is Power PC x704. erPCx704(38) deviceFamilyIsPow The processor family is Power PC 750. erPC750(39) deviceFamilyIsInt The processor family is Intel Core Duo. elCoreDuo(40) deviceFamilyIsInt The processor family is Intel Core Duo mobile. elCoreDuoMobi le(41) deviceFamilyIsInt The processor family is Intel Core Solo mobile.
deviceFamilyIsAMD The processor family is AMD Opteron 6200 Series Opteron6200 (61) Processor. deviceFamilyIsAMD The processor family is AMD Opteron 4200 Series Opteron4200 (62) Processor. deviceFamilyIsMIP The processor family is MIPS S(64) deviceFamilyIsMIP The processor family is MIPS R4000. SR4000(65) deviceFamilyIsMIP The processor family is MIPS R4200. SR4200(66) deviceFamilyIsMIP The processor family is MIPS R4400. SR4400(67) deviceFamilyIsMIP The processor family is MIPS R4600.
deviceFamilyIsHob The processor family is Hobbit. bit(112) deviceFamilyIsCru The processor family is Crusoe 5000. soe5000(120) deviceFamilyIsCru The processor family is Crusoe 3000. soe3000(121) deviceFamilyIsEff The processor family is Efficeon 8000. iceon8000 (122) deviceFamilyIsWei The processor family is Weitek. tek(128) deviceFamilyIsInt The processor family is Intel Celeron M. elCeleronM(130) deviceFamilyIsAMD The processor family is AMD Athlon 64.
deviceFamilyIsPA- The processor family is PA-RISC 8500. RISC8500(145) deviceFamilyIsPA- The processor family is PA-RISC 8000. RISC8000(146) deviceFamilyIsPAR The processor family is PA-RISC 7300LC. ISC7300LC( 147) deviceFamilyIsPA- The processor family is PA-RISC 7200. RISC7200(148) deviceFamilyIsPAR The processor family is PA-RISC 7100LC. ISC7100LC( 149) deviceFamilyIsPA- The processor family is PA-RISC 7100. RISC7100(150) deviceFamilyIsV3 0(160) The processor family is V30.
deviceFamilyIsQua The processor family is Quad-Core Intel Xeon dCoreIntelXeon730 processor 7300 Series. 0(173) deviceFamilyIsQua The processor family is Quad-Core Intel Xeon dCoreIntelXeon740 processor 7400 Series. 0(174) deviceFamilyIsMul The processor family is Multi-Core Intel Xeon tiCoreIntelXeon74 processor 7400 Series. 00(175) deviceFamilyIsM1( The processor family is M1. 176) deviceFamilyIsM2( The processor family is M2.
deviceFamilyIsInt The processor family is Intel Core2 Duo mobile elCore2DuoMob processor. ile(196) deviceFamilyIsInt The processor family is Intel Core2 Solo mobile elCore2SoloMo processor. bile(197) deviceFamilyIsInt The processor family is Intel Core i7 processor. elCorei7(198) deviceFamilyIsDua The processor family is Dual-Core Intel Celeron lCoreIntelCel Processor. eron(199) deviceFamilyIsIBM The processor family is IBM390. 390(200) deviceFamilyIsG4( The processor family is G4.
deviceFamilyIsQua The processor family is Quad-Core Intel Xeon dCoreIntelXeo processor 5xxx Series. n5xxx(219) deviceFamilyIsDua The processor family is Dual-Core Intel Xeon lCoreIntelXeo processor 7xxx Series. n7xxx(221) deviceFamilyIsQua The processor family is Quad-Core Intel Xeon dCoreIntelXeo processor 7xxx Series. n7xxx(222) deviceFamilyIsMul The processor family is Multi-Core Intel Xeon tiCoreIntelXe processor 7xxx Series.
Table 839. Cache Device Type Variable Name:DellCacheDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) System cache type is not one of the following: deviceTypeIsUnkno System cache type is unknown. wn(2) deviceTypeIsInstr System cache type is instruction. uction(3) deviceTypeIsData( System cache type is data. 4) deviceTypeIsUnifi System cache type is both instruction and data. ed(5) Table 840.
deviceWritePolicy Device write policy is determined by I/O query. IsDeterminedByIO( 6) Table 842. Cache Device Status State Variable Name:DellCacheDeviceStatusState Data Type:Integer Possible Data Values Meaning of Data Value other(1) Device state is not one of the following: unknown(2) Device state is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device basic input/output system (BIOS) is disabled. Table 843.
deviceAssociativi Device is two-way set associative. tyIsTwoWaySetAsso ciative(4) deviceAssociativi Device is four-way set associative. tyIsFourWaySetAss o ciative(5) deviceAssociativi Device is fully associative. tyIsFullyAssociat ive (6) deviceAssociativi Device is eight-way set associative. tyIsEightWaySetAs so ciative(7) deviceAssociativi Device is sixteen-way set associative. tyIsSixteenWaySet Associative(8) deviceAssociativi Device is 12-way Set-Associative.
deviceSRAMTypeIsO Device SRAM type is not one of the following: ther(1) deviceSRAMTypeIsU Device SRAM type is unknown. nknown(2) deviceSRAMTypeIsN Device SRAM type is nonburst. onBurst(3) deviceSRAMTypeIsB Device SRAM type is burst. urst(4) deviceSRAMTypeIsP Device SRAM type is pipeburst. ipeBurst(5) deviceSRAMTypeIsS Device SRAM type is synchronous. ynchronous(6) deviceSRAMTypeIsA Device SRAM type is asynchronous. synchronous(7) Table 847.
deviceFormFactorI Device form factor is SRIMM. sSRIMM(14) deviceFormFactorI Device form factor is FB-DIMM. sFBDIMM(15) Table 848. Memory Device Type Variable Name:DellMemoryDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) Device type is not one of the following: deviceTypeIsUnkno Device type is unknown. wn(2) deviceTypeIsDRAM( Device type is DRAM. 3) deviceTypeIsEDRA M(4) Device type is EDRAM. deviceTypeIsVRAM( Device type is VRAM.
deviceTypeIsDDR2F Device type is DDR2 FB-DIMM. BDIMM(20) deviceTypeIsDDR3( Device type is DDR3. 24) deviceTypeIsFBD2( Device type is FBD2. 25) Table 849. Memory Device Type Details Variable Name:DellMemoryDeviceTypeDetails Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeDetailI The detailed device type is not one of the following: sOther(2) deviceTypeDetailI The detailed device type is unknown. sUnknown(4) deviceTypeDetailI The detailed device type is fast paged.
Table 850. Generic Device Type Variable Name:DellGenericDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) Device type is not one of the following: deviceTypeIsUnkno Device type is unknown. wn(2) deviceTypeIsAVide Device type is a video. oDevice(3) deviceTypeIsASCSI Device type is a SCSI controller. Controller(4) deviceTypeIsAnEth Device type is Ethernet. ernetDevice(5) deviceTypeIsToken Device type is token ring.
connected(1) Media reports that device is connected. disconnected(2) Media reports that device is disconnected. driverBad(3) Driver cannot be opened to determine status. driverDisabled(4) Driver is disabled. hardwareInitalizi Hardware is initializing. ng(10) hardwareResettin g(11) Hardware is resetting. hardwareClosing(1 Hardware is closing down. 2) hardwareNotReady( Hardware is not ready. 13) Table 853.
Table 855. Network Device RDMA Capability Flags Variable Name:DellNetworkDeviceRDMACapabilityFlags Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for RDMA capability is not supported. unknown(1) Querying for RDMA capability is supported but query returned an error. available(2) Device has RDMA capability. notAvailable(4) Device does not have RDMA capability.
Possible Data Values Meaning of Data Value other(1) Device type is other. unknown(2) Device type is unknown. hypervisor(3) Device type is Hypervisor. vFlash(4) Device type is Virtual Flash (vFlash.) Table 859. SD Card Device Config Capabilities Variable Name:DellSDCardDeviceConfigCapabilities Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) SD card device has none of the following capabilities.
standby(256) Device is in standby mode. Table 862. SD Card Device Card Licensed Variable Name:DellSDCardDeviceCardLicensed Data Type:Integer Possible Data Values Meaning of Data Value unlicensed(0) SD card is not licensed by system vendor. licensed(1) SD card is licensed by system vendor. ipmiReady(2) Device is IPMI ready. fullReady(4) Device is full ready. offline(8) Device is offline. failed(16) Device is failed. active(32) Device is active. bootable(64) Device is bootable.
15 Slot Group The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots. System Slot Group Table The System Slot Group defines objects in the System Slot MIB table. The following object sets up the System Slot Table: Table 863. System Slot Table Name systemSlotTable Object ID 1.3.6.1.4.1.674.10892.1.1200.
Table 866. System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis. Syntax DellObjectRange Access Read-only Table 867. System Slot State Capabilities Unique Name systemSlotStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.3 Description Defines the capabilities of the system slot.
Table 871. System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7 Description Defines the type of the system slot. Syntax DellSystemSlotType (System Slot Type) Access Read-only Table 872. System Slot External Slot Name Name systemSlotSlotExternalSlotName Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.8 Description Defines the external connector name of the system slot. Syntax DellString Access Read-only Table 873.
Table 876. System Slot Hot-Plug Bus Width Name systemSlotHotPlugBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12 Description Defines the bus width of the hot-plug system slot. Syntax DellSystemSlotHotPlugBusWidth (Hot-Plug Bus Width) Access Read-only Table 877. System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13 Description Defines the slot speed in megahertz of the hot-plug system slot.
systemSlotHotPlugCanSignal PowerFault(16) Power on fault (and corresponding LED) can be detected due to a short or overcurrent. systemSlotHotPlugCanSignal AdapterPresent(32) Adapter (card) present in slot (may not be powered) can be detected. systemSlotHotPlugCanSignal PowerButtonPressed(64) The system slot power button can be pressed to signal a toggle of the power state. canSupportAllHotPlugCapabi lities(126) The system slot can support all hot-plug capabilities.
systemSlotHotPlugAdapterIsPresent (32) Adapter (card) present in slot (may not be powered). systemSlotHotPlugAdapterPresentAnd PoweredOn(36) Adapter (card) present in slot and powered. systemSlotHotPlugPowerButtonPressed (64) The system slot power button pressed to signal a toggle of the power state. systemSlotProvides5Volts(128) The system slot provides a 5-V supply. systemSlotProvides3Point3Volts(256) The system slot provides a 3.3-V supply.
systemSlotIsPCMCIA(7) . The system slot is compliant with the Personal Computer Memory Card International Association (PCMCIA) standards systemSlotIsVLVESA(8) The system slot is Very Low Voltage Enterprise System Architecture (VLVESA). systemSlotIsProprietary(9) The system slot is proprietary. systemSlotIsProcessorCard(10) The system slot is a processor card. systemSlotIsProprietaryMemory(11) The system slot is proprietary memory. systemSlotIsIORiserCard(12) The system slot is an I/O riser card.
Table 882. System Slot Usage Variable Name: DellSystemSlotUsage Data Type: Integer Possible Data Values Meaning of Data Value systemSlotUsageIsOther(1) The system slot usage is not one of following: systemSlotUsageIsUnknown(2) The system slot usage is unknown. systemSlotUsageIsAvailable(3) The system slot is available. systemSlotUsageIsInUse(4) The system slot is in use. Table 883.
busWidthIs16bits(4) The system slot bus width is 16 bits. busWidthIs32bits(5) The system slot bus width is 32 bits. busWidthIs64bits(6) The system slot bus width is 64 bits. busWidthIs128bits(7) The system slot bus width is 128 bits. busWidthIs1xOrx1(8) The system slot bus width is 1x or x1. busWidthIs2xOrx2(9) The system slot bus width is 2x or x2. busWidthIs4xOrx4(10) The system slot bus width is 4x or x4. busWidthIs8xOrx8(11) The system slot bus width is 8x or x8.
16 Memory Group The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory.
Syntax PhysicalMemoryArrayTableEntry Access Not accessible Table 887. Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1 Description Defines the Physical Memory Array Table entry. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Index physicalMemoryArraychassisIndex , physicalMemoryArrayIndex Table 888. Physical Memory Array Chassis Index Name physicalMemoryArraychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.
Table 891. Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array. Syntax DellStateSettings Access read-write Table 892. Physical Memory Array Status Name physicalMemoryArrayStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.5 Description Defines the status of the physical memory array. Syntax DellStatus Access Read-only Table 893.
Table 896. Physical Memory Array Maximum Size Name physicalMemoryArrayMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.9 Description Defines the size in KB of the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Table 897. Physical Memory Array Total Number Sockets Name physicalMemoryArrayTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.10 Description Defines the total number of memory sockets available for the physical memory array.
Table 901. Physical Memory Array ECC Error Noncritical Threshold Name physicalMemoryArrayECCErrorNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.14 Description Defines the value of the physical memory array ECC error noncritical threshold. Syntax DellSigned32BitRange Access read-write Table 902. Physical Memory Array Redundant Memory Unit Index Reference Name physicalMemoryArrayRedundantMemoryUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
Table 905. Physical Memory Array Mapped Chassis Index Name physicalMemoryArrayMappedchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 906. Physical Memory Array Mapped Index Name physicalMemoryArrayMappedIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.2 Description Defines the index (one-based) of the memory array mapped address in this chassis.
Table 910. Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis. Syntax DellObjectRange Access Read-only Table 911. Physical Memory Array Mapped Starting Address Name physicalMemoryArrayMappedStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.
Description Defines the Physical Memory Configuration Table. Syntax SEQUENCE OF PhysicalMemoryConfigTableEntry Access Not accessible Table 915. Physical Memory Configuration Table Entry Name physicalMemoryConfigTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1 Description Defines the Physical Memory Configuration Table entry. Syntax PhysicalMemoryConfigTableEntry Access Not accessible Index physicalMemoryConfigChassisIndex , physicalMemoryConfigIndex Table 916.
Table 919. Physical Memory Configuration State Settings Name physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4 Description Defines the state settings of the physical memory configuration. Syntax DellPhysicalMemoryConfigStateSettings Access Read-write Table 920. Physical Memory Configuration Status Name physicalMemoryConfigStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5 Description Defines the status of the physical memory configuration.
Table 924. Physical Memory Configuration MOM Settings Name physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9 Description Defines the Memory Operating Mode settings of the physical memory. Syntax DellPhysicalMemoryConfigMOMSettings Access Read-only Physical Memory Logging Table This table defines the conditions for logging system memory events. The following object sets up the Physical Memory Logging Table: Table 925.
Table 928. Physical Memory Logging Index Name physicalMemoryLoggingIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.2 Description Defines the index (one-based) of the physical memory logging. Syntax DellObjectRange Access Read-only Table 929. Physical Memory Logging Capabilities Name physicalMemoryLoggingCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.3 Description Defines the capabilities of the physical memory logging.
Access Not accessible Table 933. Redundant Memory Unit Table Entry Name redundantMemoryUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1 Description Defines the Redundant Memory Unit Table entry. Syntax RedundantMemoryUnitTableEntry Access Not accessible Index redundantMemoryUnitChassisIndex , redundantMemoryUnitIndex Table 934. Redundant Memory Unit Chassis Index Name redundantMemoryUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.
Table 937. Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit. Syntax DellStateSettings Access Read-write Table 938. Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5 Description Defines the redundancy status of the redundant memory unit.
Description Defines the Physical Memory Card Table. Syntax SEQUENCE OF PhysicalMemoryCardTableEntry Access Not accessible Table 942. Physical Memory Card Table Entry Name physicalMemoryCardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1 Description Defines the Physical Memory Card Table Entry. Syntax PhysicalMemoryCardTableEntry Access Not accessible Index physicalMemoryCardChassisIndex , physicalMemoryCardIndex Table 943.
Table 946. Physical Memory Card State Settings Name physicalMemoryCardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.4 Description Defines the state settings of the Physical Memory Card. Syntax DellStateSettings Access Read-write Table 947. Physical Memory Card Status Name physicalMemoryCardStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.5 Description Defines the status of the Physical Memory Card. Syntax DellStatus Access Read-only Table 948.
Access Read-only Table 951. Physical Memory Card Physical Memory Array Index Reference Name physicalMemoryCardPhyMemArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.9 Description Defines the index (one-based) of the Physical Memory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with.
Table 953. Physical Memory Array ECC Type Definitions Variable Name: DellPhysicalMemoryArrayECCType Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayECCTypeIsOther(1) There is not one of the following: memoryArrayECCTypeIsUnknown(2) The memory array ECC type is unknown. memoryArrayECCTypeIsNone(3) The memory array ECC type is none. memoryArrayECCTypeIsParity(4) The memory array ECC type is parity.
Table 956. Physical Memory Configuration Redundant Capabilities Variable Name: DellPhysicalMemoryConfigRedundantCapabilities Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory capabilities. unknownCapabilities(1) Redundant capabilities are unknown. The redundant capabilities are: spareCapable(2) Spare redundant memory feature is supported. mirrorCapable(4) Mirror redundant memory feature is supported.
Table 959. Physical Memory Logging Settings Variable Name: DellPhysicalMemoryLoggingSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging settings enabled. unknown Capabilities(1) Logging capabilities are unknown. The logging settings are: enabled(2) Logging is disabled (0), or enabled (1).
BIOS Setup Control Group 17 Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature.
Access Not accessible Index biosSetUpControlchassisIndex Table 962. BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 963. BIOS Setup Control (BSUC) Pointing Device Control Capabilities Name bSUCpointingDeviceControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Access Read-only Table 967. BIOS Setup Control Numeric Lock Control Capabilities Name bSUCnumLockControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.6 Description Defines the capabilities of the numeric lock. Syntax DellStateCapabilities Access Read-only Table 968. BIOS Setup Control Numeric Lock Control Settings Name bSUCnumLockControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.7 Description Defines the state of the numeric lock.
Access Read-only Table 972. BIOS Setup Control Processor Serial Number Control Settings Name bSUCprocessorSerialNumberControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.11 Description Defines the state of the processor serial number. Syntax DellStateSettings Access Read-only Table 973. BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Access Read-only Table 977. BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only Table 978. BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17 Description Defines the setup BIOS name of the speaker control. Syntax DellString Access Read-only Table 979.
Syntax DellStatus Access Read-only Table 982. BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN. Syntax DellString Access Read-only Table 983. BIOS Setup Control Boot Sequence Control Capabilities Unique Name bSUCbootSequenceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Syntax DellString Access Read-only Table 987. BIOS Setup Control Administrator Password Control Capabilities Unique Name bSUCadministratorPasswordControlCapabilities Unique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.26 Description Defines the capabilities of the administrator password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only Table 988.
Description Defines the setup BIOS name of the new administrator password. To set a new administrator password, you must have successfully set the current administrator password immediately preceding this password change. Syntax DellString Access Read-write Table 992. BIOS Setup Control User Password Control Capabilities Unique Name bSUCuserPasswordControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.31 Description Defines the capabilities of user password control.
Description Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user password immediately preceding this password change. Syntax DellString Access Read-write Table 997. BIOS Setup Control TPM Security Control Capabilities Name bSUCtpmSecurityControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.36 Description Defines the BIOS setup control capabilities of Trusted Platform Module (TPM) security.
SCSI Control Table Table 1001. SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table. Syntax SCSIControlTableEntry Access Not accessible Table 1002. SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1 Description x Defines the SCSI Control Table entry.
Syntax DellStateCapabilities Access Read-only Table 1006. SCSI Control Settings Name sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4 Description Defines the state of the SCSI controller. Syntax DellStateSettings Access Read-only Table 1007. SCSI Control Status Name sCSIControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.5 Description Defines the status of the SCSI controller. Syntax DellStatus Access Read-only Table 1008.
Access Not accessible Index parallelPortControlchassisIndex , parallelPortControlIndex Table 1011. Parallel Port Control Chassis Index Name parallelPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1012. Parallel Port Control Index Name parallelPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.
Access Read-only Table 1016. Parallel Port Control Name Name parallelPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6 Description Defines the setup BIOS name of the parallel port. Syntax DellString Access Read-only Table 1017. Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7 Description Defines the mode capabilities of the parallel port.
Index serialPortControlchassisIndex , serialPortControlIndex Table 1021. Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Table 1022. Serial Port Control Index Name serialPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2 Description Defines the index (one-based) of the serial port in this chassis.
Table 1026. Serial Port Control Name Name serialPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6 Description Defines the setup BIOS name of the serial port. Syntax DellString Access Read-only USB Control Table These objects enable you to track the attributes of your Universal Serial Bus (USB). Table 1027. USB Control Table Name usbControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.50 Description Defines the USB Table.
Syntax DellObjectRange Access Read-only Table 1031. USB Control Capabilities Name usbControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3 Description Defines the capabilities of the USB. Syntax DellStateCapabilities Access Read-only Table 1032. USB Control Settings Name usbControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.4 Description Defines the control settings for the USB. Syntax DellStateSettings Access Read-only Table 1033.
Access Not accessible Table 1036. IDE Control Table Entry Name ideControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1 Description Defines the IDE Control Table entry. Syntax IdeControlTableEntry Access Not accessible Index ideControlchassisIndex , ideControlIndex Table 1037. IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis.
Access Read-only Table 1041. IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only Table 1042. IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6 Description Defines the setup BIOS name for the IDE controller. Syntax DellStatus Access Read-only Diskette Control Table Table 1043.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1046. Diskette Control Index Name disketteControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2 Description Defines the index of the diskette controllers in this chassis. Syntax DellObjectRange Access Read-only Table 1047. Diskette Control Capabilities Unique Name disketteControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.
Network Interface Control Table These MIB objects enable you to track the attributes of the NIC card for your system. Table 1051. Network Interface Control Table Name networkInterfaceControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.80 Description Defines the Network Interface Control Table. Syntax NetworkInterfaceControlTableEntry Access Not accessible Table 1052. Network Interface Control Table Entry Name networkInterfaceControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.80.
Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Network Interface Control Capabilities) Access Read-only Table 1056. Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.4 Description Defines the control settings for the NIC. Syntax DellNetworkInterfaceControlSettingsUnique (See Network Interface Control Settings) Access Read-write Table 1057.
Table 1060. BIOS Setting Table Entry Name biosSettingTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1 Description Defines the BIOS Setting Table Entry. Syntax BiosSettingTableEntry Access Not accessible Index biosSettingChassisIndex , biosSettingIndex Table 1061. BIOS Setting Chassis Index Name biosSettingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.1 Description Defines the index (one based) of the associated chassis.
Table 1065. BIOS Setting Value Type Name biosSettingValueType Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.5 Description Defines the type of the BIOS setting value. Syntax DellBIOSSettingValueType Access Read-only Table 1066. BIOS Setting Current Value Name biosSettingCurrentValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.6 Description Defines the current value of the BIOS setting. Syntax DisplayString Access Read-only Table 1067.
Description Defines the recommended display order of the BIOS setting within its BIOS setting group. Syntax DellUnsigned32BitRange Access Read-only Table 1071. BIOS Setting Group Display Name Name biosSettingGroupDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.11 Description Defines the display name of the BIOS setting group for the BIOS setting. Syntax DisplayString Access Read-only Table 1072. BIOS Setting FQDD Name biosSettingFQDD Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.
unknown(1) Speaker control state is unknown. enabled(2) Speaker control is enabled. low(4) Speaker control volume is low. medium(8) Speaker control volume is medium. high(16) Speaker control volume is high. Table 1075. Network Interface (NIF) Wakeup on LAN Capabilities Unique Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown.
bootFromhardDriveFirstCapable (4) Setup BIOS can boot from an IDE hard drive first. bootFromDisketteORHardDrive FirstCapable(6) Setup BIOS can boot from a diskette or an IDE hard drive first. bootFromDeviceListCapable(8) Setup BIOS can boot from a device list. bootFromCDROMFirstCapable(16) Setup BIOS can boot from a CD first. allFirstCapable(30) Setup BIOS can boot by any of the preceding methods first. Table 1078.
passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 1081. BIOS Password Control Settings Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) Setup BIOS password state is unknown. passwordControlEnabled(2) Setup BIOS has password changes enabled.
lpt2Capable(8) Setup BIOS can support parallel port 2. lpt2andEnableCapable(10) Setup BIOS has enabled parallel port 2. lpt3Capable(16) Setup BIOS can support parallel port 3. lpt3andEnableCapable(18) Setup BIOS has enabled parallel port 3. allParallelPortCapable(30) Setup BIOS can support any of the three parallel ports. Table 1085.
enableCapable(2) Setup BIOS can enable the serial port. com1Capable(4) Setup BIOS can support serial port 1. enableAndCom1Capable(6) Setup BIOS can enable serial port 1. com2Capable(8) Setup BIOS can support serial port 2. enableAndCom2Capable(10) Setup BIOS is capable of enabling serial port 2. com3Capable(16) Setup BIOS can support serial port 3. enableAndCom3Capable(18) Setup BIOS is capable of enabling serial port 3. com4Capable(32) Setup BIOS can support serial port 4.
Table 1089. IDE Control Capabilities Variable Name: DellideControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) IDE control capabilities are unknown. ideControlAutoConfigOrEnable Capable(2) IDE controller is autoconfigurable or enable capable. Table 1090. Diskette Control Settings Variable Name: DellDisketteControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Diskette control state is unknown.
integer(1) Value type is integer. string(2) Value type is string. enumeration(3) Value type is enumeration. orderedList(4) Value type is ordered list.
Local Response Agent Group 18 The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA). The LRA allows systems managers to predetermine how a system running the server administrator responds to a particular event type, such as the loss of redundancy in a specific component or the elevation of temperature in a chassis. Systems managers can configure the LRA to respond to an event type with a specific action.
Syntax LRAGlobalSettingsTableEntry Access Not accessible Index lRAGlobalchassisIndex Table 1096. LRA Global Chassis Index Name lRAGlobalchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1097. LRA Global State Name lRAGlobalState Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.2 Description Defines the state of the LRA global settings.
Description Defines the set of thermal shutdown capabilities that are supported by the LRA. Syntax DellLRAThermalShutdownCapabilitiesUnique Access Read-only Table 1101. LRA Global Thermal Shutdown State Settings Unique Name lRAGlobalThermalShutdownStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.6 Description Defines the set of thermal shutdown state and settings that the local response agent supports.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1105. LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index.
Syntax DisplayString (SIZE (0..256) Access Read-write Table 1107. LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.4 Description Defines the LRA settings. Syntax DellLocalResponseAgentSettingsUnique (Local Response Agent Settings Unique) Access Read-write Local Response Agent Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 1108.
warningCapable(4) The LRA can carry out chassis-determined action(s) when a warning condition is detected. enableOnWarningCapable(6) The LRA enables activation of chassisdetermined action(s) when a warning condition is detected. failureCapable(8) The LRA can carry out chassis-determined action(s) when a failure condition is detected. enableOnFailureCapable(10) The LRA enables activation of chassisdetermined action(s) when a failure condition is detected.
Cost of Ownership Group 19 The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accurate and complete measurements of the cost of each computer asset in your organization.
Syntax CooTableEntry Access Not accessible Index coochassisIndex Table 1113. COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only Table 1114. COO State Name cooState Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.2 Description Defines the acquisition state of the system. Syntax DellStateSettings Access Read-only Table 1115.
Syntax DellDateName Access Read-write Table 1118. COO Acquisition Purchase Order Name cooAquisitionPurchaseOrder Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.6 Description Defines the purchase order number of the system. Syntax DellUnsigned32BitRange Access Read-write Table 1119. COO Acquisition Purchase Date Name Name cooAquisitionPurchaseDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.7 Description Defines the purchase date and time of the system.
Access Read-only Table 1123. COO Cost Center Information Vendor Name Name cooCostCenterInformationVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.11 Description Defines the cost center name of the system. Syntax DellCostofOwnershipString Access Read-write Table 1124. COO User Information User Name Name cooUserInformationUserName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12 Description Defines the name of the user for this system.
Access Read-write Table 1128. COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-write Table 1129. COO Ownership Code Name cooOwnershipCode Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17 Description Defines the ownership code for this system.
Access Read-write Table 1133. COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system. Syntax DellCooHourDayDurationType (See COO Hour Day Duration Type) Access Read-write Table 1134. COO Training Name Name cooTrainingName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.22 Description Defines the training that the user has for this system.
Access Read-write Table 1138. COO Outsourcing Provider Fee Name Name cooOutsourcingProviderFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26 Description Defines any additional outsourcing charge for service. Syntax DellCostofOwnershipString Access Read-write Table 1139. COO Outsourcing Provider Service Level Name Name cooOutsourcingProviderServiceLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.27 Description Defines the service level agreement for the system.
Access Read-write Table 1143. COO Box Central Processing Unit (CPU) Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.31 Description Defines the name of the CPU serial number for the system. Syntax DellCostofOwnershipString Access Read-write Table 1144. COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system.
Access Read-write Table 1148. COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-write Table 1149. COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system.
Description Defines the COO Service Contract Table. Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible Table 1153. COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1 Description Defines the COO Service Contract Table entry. Syntax CooServiceContractTableEntry Access Not accessible Index cooServiceContractchassisIndex , cooServiceContractIndex Table 1154.
Table 1157. COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed. Syntax DellBoolean Access Read-write Table 1158. COO Service Contract Type Name Name cooServiceContractTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.5 Description Defines the name of the service contract type for this system.
Syntax cooCostEventLogTableEntry Access Not accessible Index cooCostEventLogchassisIndex , cooCostEventLogIndex Table 1162. COO Cost Event Log Chassis Index Name cooCostEventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1163. COO Cost Event Log Index Name cooCostEventLogIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.
Table 1166. COO Cost Event Log Duration Type Name cooCostEventLogDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.5 Description Defines the duration type of the event for this system. Syntax DellCOOHourDayDurationType (See COO Hour Day Duration Type) Access Read-write Table 1167. COO Cost Event Log Description Name Name cooCostEventLogDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.6 Description Defines the name of the event description.
Table 1170. COO Warranty Chassis Index Name cooWarrantychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-write Table 1171. COO Warranty Index Name cooWarrantyIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.2 Description Defines the index of the warranty for this system. Syntax DellObjectRange Access Read-only Table 1172. COO Warranty State Name cooWarrantyState Object ID 1.3.6.
Table 1175. COO Warranty End Date Name Name cooWarrantyEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.6 Description Defines the warranty end date for this system. Syntax DellDateName Access Read-write Table 1176. COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7 Description Defines the cost of the warranty for this system.
Table 1179. COO Lease Information Chassis Index Name cooLeaseInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1180. COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system. Syntax DellObjectRange Access Read-only Table 1181.
Table 1184. COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-write Table 1185. COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system.
Access Not accessible Table 1189. COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1 Description Defines the COO Schedule Number Information Table entry. Syntax CooScheduleNumberTableEntry Access Not accessible Index cooScheduleNumberchassisIndex , cooScheduleNumberIndex Table 1190. COO Schedule Number Chassis Index Name cooScheduleNumberchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.
Description Defines the lease information index number to reference the schedule number. Syntax DellUnsigned32BitRange Access Read-write Table 1194. COO Schedule Number Description Name Name cooScheduleNumberDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.5 Description Describes the schedule number information. Syntax DellCostofOwnershipString Access Read-write COO Options Table Table 1195. COO Options Table Name cooOptionsTable Object ID 1.3.6.1.4.1.674.10892.1.1600.
Access Read-only Table 1198. COO Options Index Name cooOptionsIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.2 Description Defines the index (one-based) of the option information for this system. Syntax DellObjectRange Access Read-only Table 1199. COO Options State Name cooOptionsState Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.3 Description Defines the option information state for this system. Syntax DellStateSettings Access Read-only Table 1200.
Syntax SEQUENCE OF CooMaintenanceTableEntry Access Not accessible Table 1203. COO Maintenance Table Entry Name cooMaintenanceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1 Description Defines the COO Maintenance Table entry. Syntax CooMaintenanceTableEntry Access Not accessible Index cooMaintenancechassisIndex , cooMaintenanceIndex Table 1204. COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.
Table 1207. COO Maintenance Start Date Name Name cooMaintenanceStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.4 Description Defines the start date for maintenance on this system. Syntax DellDateName Access Read-write Table 1208. COO Maintenance End Date Name Name cooMaintenanceEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5 Description Defines the end date for maintenance on this system. Syntax DellDateName Access Read-write Table 1209.
Access Not accessible Table 1212. COO Repair Table Entry Name cooRepairTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1 Description Defines the COO Repair Table entry. Syntax CooRepairTableEntry Access Not accessible Index cooRepairchassisIndex , cooRepairIndex Table 1213. COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis.
Description Defines the number of repairs that this system has undergone. Syntax DellCostofOwnershipString Access Read-write Table 1217. COO Repair Vendor Name Name cooRepairVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5 Description Defines the name of the vendor that repairs this system. Syntax DellStateSettings Access Read-only COO Support Information Table Table 1218. COO Support Information Table Name cooSupportInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.
Access Read-only Table 1221. COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information. Syntax DellObjectRange Access Read-only Table 1222. COO Support Information State Name cooSupportInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.3 Description Defines the support information state for this system.
Access Read-write Table 1226. COO Support Information Fix Type Name Name cooSupportInformationFixTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.7 Description Defines the method used to fix the problem. Syntax DellCostofOwnershipString Access Read-write COO Trouble Ticket Table The MIB objects in the Trouble Ticket Table enable you to track details of any trouble tickets that you open for your system. Table 1227. COO Trouble Ticket Table Name cooTroubleTicketTable Object ID 1.3.6.1.4.
Table 1230. COO Trouble Ticket Index Name cooTroubleTicketIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.2 Description Defines the index (one-based) of the system’s trouble ticket information. Syntax DellObjectRange Access Read-only Table 1231. COO Trouble Ticket State Name cooTroubleTicketState Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.3 Description Defines the trouble ticket information state for this system. Syntax DellStateSettings Access Read-only Table 1232.
unknown(2) The ownership code is unknown. owned(3) The ownership code is owned. leased(4) The ownership code is leased. rented(5) The ownership code is rented. offOfLease(6) The ownership code is off of lease. transfer(7) The ownership code is transfer. Table 1235. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. hours(2) Duration time type is in hours.
Remote Access Group 20 The Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to providing general information about the capabilities and settings of the remote access hardware, this group provides information about administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations.
Access Read-only Table 1241. Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware. Syntax DellObjectRange Access Read-only Table 1242. Remote Access Type Name remoteAccessType Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3 Description Defines the type of remote access hardware. Syntax DellRemoteAccessType (Remote Access Type) Access Read-only Table 1243.
Table 1246. Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7 Description Defines the name of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Table 1247. Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.8 Description Defines the description of the product providing the remote access functionality.
Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Table 1252. Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Table 1253.
Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Table 1257. Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.31 Description Defines the netmask currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Table 1258.
• Remote SNMP Trap Table • Remote Dial-Up Table • Remote User Dial-In Configuration Table • Remote Dial-Out Table Remote Access Table The following MIB object sets up the Remote Access Table. Table 1261. Remote Access Table Name remoteAccessTable Object ID 1.3.6.1.4.1.674.10892.1.1700.10 Description Defines the Remote Access Table. Syntax SEQUENCE OF RemoteAccessTableEntry Access Not accessible Table 1262. Remote Access Table Entry Name remoteAccessTableEntry Object ID 1.3.6.1.4.1.
Table 1265. Remote Access Type Name remoteAccessType Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3 Description Defines the type of remote access hardware. Syntax DellRemoteAccessType (Remote Access Type ) Access Read-only Table 1266. Remote Access State Capabilities Name remoteAccessStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.4 Description Defines the state capabilities of the remote access hardware. Syntax DellStateCapabilities Access Read-only Table 1267.
Description Defines the description of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..255)) Access Read-only Table 1271. Remote Access Version Info Name Name remoteAccessVersionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.9 Description Defines the version of the product providing the remote access functionality. Syntax DellDisplayString (SIZE (0..63)) Access Read-only Table 1272.
Table 1276. Remote Access Local Area Network (LAN) Capabilities Name remoteAccessLANCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14 Description Defines the LAN capabilities of the remote access hardware. Syntax DellRemoteAccessLANCapabilities (Remote Access Local Area Network (LAN) Capabilities ) Access Read-only Table 1277. Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Table 1281. Remote Access Out-of-Band SNMP Settings Name remoteAccessOutOfBandSNMPSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.19 Description Defines the out-of-band SNMP settings of the remote access hardware. Syntax DellRemoteAccessOutOfBandSNMPSettings (Remote Access Out-Of-Band Simple Network Management Protocol Settings ) Access Read-write Table 1282.
Table 1286. Remote Access Firmware Update Path Name Name remoteAccessFirmwareUpdatePathName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.24 Description Defines the file name of the firmware image obtained from the update server used by the remote access hardware. Syntax DisplayString (SIZE (0..255)) Access Read-write Table 1287. Remote Access Network Interface Controller (NIC) Static IP Address Name remoteAccessNICStaticIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Table 1291. Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.29 Description Defines the miscellaneous information for the remote access hardware. Syntax DisplayString (SIZE (0..63)) Access Read-write Table 1292. Remote Access NIC Current IP Address Name remoteAccessNICCurrentIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Remote User Administration Table Table 1296. Remote User Administration Table Name remoteUserAdminTable Object ID 1.3.6.1.4.1.674.10892.1.1700.20 Description Defines the Remote Access User Administration Table. Syntax SEQUENCE OF RemoteUserAdminTableEntry Access Not accessible Table 1297. Remote User Admin Table Entry Name remoteUserAdminTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1 Description Defines the Remote Access User Administration Table entry.
Table 1300. Remote User Admin User Index Name remoteUserAdminUserIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.3 Description Defines the index (one-based) of this remote access user. Syntax DellObjectRange Access Read-only Table 1301. Remote User Admin State Capabilities Name remoteUserAdminStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.4 Description Defines the state capabilities for this remote access user.
Description Defines the password for this remote access user. Syntax DisplayString (SIZE (0..255)) Access Read-write Table 1306. Remote User Admin User Privilege Name remoteUserAdminUserPrivilege Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.9 Description Defines the privileges for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Table 1307. Remote User Admin User Privilege Capabilities Name remoteUserAdminUserPrivilegeCapabilities Object ID 1.3.6.1.4.1.674.
Table 1311. Remote User Admin Alert Filter System Capabilities Name remoteUserAdminAlertFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.14 Description Defines the system events filter capabilities for this remote access user. Syntax DellUnsigned32BitRange Access Read-only Table 1312. Remote User Admin Pager Numeric Number Name Name remoteUserAdminPagerNumericNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
Description Defines the protocol used by the alphanumeric pager provider for this remote access user. Syntax DellRemoteUserAdminAlphaProtocolType (Remote User Admin Alpha Protocol Type) Access Read-write Table 1317. Remote User Admin Pager Alpha Baud Rate Name remoteUserAdminPagerAlphaBaudRate Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.20 Description Defines the baud rate used by the alphanumeric pager provider for this remote access user.
Description Defines the password for the alphanumeric pager for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Table 1322. Remote User Admin Pager Modem Init String Name Name remoteUserAdminPagerModemInitStringName Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.25 Description Defines the initialization string to be sent to the pager modem for this remote access user. Syntax DisplayString (SIZE (0..31)) Access Read-write Table 1323.
Access Read-only Table 1327. Remote User Admin Control Settings Name remoteUserAdminControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.30 Description Defines the control settings for this remote access user. Syntax DellRemoteUserAdminControlSettings (Remote User Admin Control Settings ) Access Read-write Table 1328. Remote User Admin User Type Name remoteUserAdminUserType Object ID 1.3.6.1.4.1.674.10892.1.1700.20.1.
Table 1331. Remote SNMP Trap Chassis Index Name remoteSNMPTrapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.1 Description Defines the index (one-based) of the chassis containing the remote access hardware. Syntax DellObjectRange Access Read-only Table 1332. Remote SNMP Trap Adapter Index Name remoteSNMPTrapAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.2 Description Defines the index (one-based) of the remote access hardware that uses this SNMP trap destination.
Table 1336. Remote SNMP Trap Status Name remoteSNMPTrapStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.6 Description Defines the status of this remote access SNMP trap destination. Syntax DellStatus Access Read-only Table 1337. Remote SNMP Trap Destination IP Address Name remoteSNMPTrapDestinationIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.7 Description Defines the IP address of this remote access SNMP trap destination. Syntax IpAddress Access Read-write Table 1338.
Table 1341. Remote SNMP Trap Filter DRS Capabilities Name remoteSNMPTrapFilterDrsCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.11 Description Defines the DRS events filter capabilities for this remote access SNMP trap destination. Syntax DellUnsigned32BitRange Access Read-only Table 1342. Remote SNMP Trap Filter System Capabilities Name remoteSNMPTrapFilterSysCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.30.1.
Table 1346. Remote Dial-Up Table Entry Name remoteDialUpTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1 Description Defines the Remote Access Dial-Up Table entry. Syntax RemoteDialUpTableEntry Access Not accessible Index remoteDialUpChassisIndex , remoteDialUpAdapterIndex , remoteDialUpIndex Table 1347. Remote Dial-Up Chassis Index Name remoteDialUpChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
Syntax DellRemoteDialUpStateCapabilities (Remote Dial-Up State Capabilities) Access Read-only Table 1351. Remote Dial-Up State Settings Name remoteDialUpStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.5 Description Defines the state settings of this remote access dial-up functionality. Syntax DellRemoteDialUpStateSettings (Remote Dial-Up State Settings) Access Read-write Table 1352. Remote Dial-Up Status Name remoteDialUpStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
Access Read-write Table 1356. Remote Dial-Up Dial-Out Modem Connect Time-out Name remoteDialUpDialOutModemConnectTimeout Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.10 Description Defines the modem dial-out time-out value in seconds for this remote access dialup functionality. Syntax DellUnsigned32BitRange Access Read-write Table 1357. Remote Dial-Up Modem Dial Type Name remoteDialUpModemDialType Object ID 1.3.6.1.4.1.674.10892.1.1700.40.1.
Remote User Dial-In Configuration Table Table 1361. Remote User Dial-In Configuration Table Name remoteUserDialInCfgTable Object ID 1.3.6.1.4.1.674.10892.1.1700.50 Description Defines the Remote Access User Dial-In Configuration Table. Syntax SEQUENCE OF RemoteUserDialInCfgTableEntry Access Not accessible Table 1362. Remote User Dial-In Configuration Table Entry Name remoteUserDialInCfgTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.50.
Table 1365. Remote User Dial-In Configuration User Index Name remoteUserDialInCfgUserIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.3 Description Defines the index (one-based) of this remote access dial-in user. Syntax DellObjectRange Access Read-only Table 1366. Remote User Dial-In Configuration State Capabilities Name remoteUserDialInCfgStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.4 Description Defines the state capabilities of this remote access dial-in user.
Description Defines the PPP password of this remote access dial-in user. Syntax DisplayString (SIZE (0..15)) Access Read-write Table 1371. Remote User Dial-In Configuration Callback Phone Number Name Name remoteUserDialInCfgCallbackPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.50.1.9 Description Defines the callback phone number for this remote access dial-in user. Syntax DisplayString (SIZE (0..95)) Access Read-write Remote Dial-Out Table Table 1372.
Access Read-only Table 1375. Remote Dial-Out Adapter Index Name remoteDialOutAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.2 Description Defines the index (one-based) of the remote access hardware that supports this remote access dial-out functionality. Syntax DellObjectRange Access Read-only Table 1376. Remote Dial-Out Dial-Out Index Name remoteDialOutDialOutIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.
Table 1380. Remote Dial-Out IP Address Name remoteDialOutIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.7 Description Defines the IP address for this remote access dial-out destination. Syntax IpAddress Access Read-write Table 1381. Remote Dial-Out Phone Number Name Name remoteDialOutPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.1700.60.1.8 Description Defines the phone number for this remote access dial-out destination. Syntax DisplayString (SIZE (0..
remoteAccessType IsDRACIII(3) The remote access type is DRAC III. remoteAccessType IsERA(4) The remote access type is ERA. Table 1385. Remote Access Control Capabilities Variable Name:DellRemoteAccessControlCapabilities Data Type:Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no control capabilities. unknownCapabilit ies(1) The remote access hardware control capabilities are unknown.
shutdown(64) The remote access hardware shuts down. Table 1387. Remote Access Monitor Capabilities Variable Name:DellRemoteAccessMonitorCapabilities Data Type:Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no monitor capabilities. unknownCapabilit ies(1) The remote access hardware monitor capabilities are unknown. extPwrSupplyMoni torIfConn ectedCapable(2) The remote access hardware can be set to monitor the external power supply, if connected.
nicDHCPCapable(4 ) The remote access hardware NIC can use DHCP to obtain an IP address. Table 1390. Remote Access LAN Settings Variable Name:DellRemoteAccessLANSettings Data Type:Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no LAN settings. unknown(1) The remote access hardware LAN settings are unknown. nicEnabled(2) The remote access hardware NIC is enabled. nicDHCPEnabled(4 ) The remote access hardware NIC uses DHCP to obtain an IP address.
Table 1393. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) Capabilities Variable Name:DellRemoteAccessOutOfBandSNMPCapabilities Data Type:Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no out-of-band SNMP capabilities. unknownCapabilit ies(1) The remote access hardware out-of-band SNMP capabilities are unknown. oobSNMPAgentCapa ble(2) The remote access hardware has an out-of-band SNMP agent.
privilegeCapabl e(64) The admin user supports user privileges configuration. Table 1396. Remote User Admin State Settings Variable Name:DellRemoteUserAdminStateSettings Data Type:Integer Possible Data Values Meaning of Data Value none(0) The admin user has no state settings. unknown(1) The admin user state settings are unknown. enabled(2) The admin user is enabled. notReady(4) The admin user is in the not ready state. numericPagerEnab led(8) Numeric paging is enabled for the admin user.
emailTest(8) An e-mail test is performed for the admin user. Table 1399. Remote User Admin Alpha Protocol Type Variable Name:DellRemoteUserAdminAlphaProtocolType Data Type:Integer Possible Data Values Meaning of Data Value other(1) The remote user admin alpha protocol type is not one of the following: unknown(2) The remote user admin alpha protocol type is unknown. alpha7E0(3) The remote user admin alpha protocol type is 7E0. alpha8N1(4) The remote user admin alpha protocol type is 8N1.
unknown(1) The SNMP trap destination state settings are unknown. enabled(2) The SNMP trap destination is enabled. notReady(4) The SNMP trap destination is in the not ready state. Table 1403. Remote SNMP Trap Control Capabilities Variable Name:DellRemoteSNMPTrapControlCapabilities Data Type:Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no control capabilities. unknownCapabilit ies(1) The SNMP trap destination control capabilities are unknown.
dialInDHCPCapabl e(32) The dial-up functionality can support using DHCP to obtain an IP address for the dial-in feature. dialInAuthAnyCap able(64) The dial-up functionality can support any authentication type (including clear text) for the dial-in feature. dialInAuthEncryp tedCapable(128) The dial-up functionality can support encrypted passwords (CHAP) authentication for the dial-in feature.
remoteDialUpIsTo ne(3) The remote dial type is tone. remoteDialUpIsPu lse(4) The remote dial type is pulse. Table 1408. Remote User Dial-In State Capabilities Variable Name:DellRemoteUserDialInStateCapabilities Data Type:Integer Possible Data Values Meaning of Data Value none(0) The dial-in user has no state capabilities. unknownCapabilit ies(1) The dial-in user state capabilities are unknown. enableCapable(2) The dial-in user can be disabled or enabled.
enableCapable(2) The dial-out destination can be disabled or enabled. notReadyCapable( 4) The dial-out destination can be in the not ready state. dialOutPPPAuthAn yCapable(8) The dial-out destination can support any authentication type (including clear text) for PPP. dialOutPPPAuthEn cryptedCapable(1 6) The dial-out destination can support encrypted passwords authentication type for PPP. dialOutPPPAuthMs chapCapable(32) The dial-out destination can support MSCHAP authentication type for PPP.
21 Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher availability, scalability, and management. Higher availability is achieved by using failover clusters, in which resources can automatically move between two or more systems in the event of a failure. Scalability is achieved by balancing the load of an application across several computer systems.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1415. Cluster Index Name clusterIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.2 Description Defines the index (one-based) of the cluster. Syntax DellObjectRange Access Read-only Table 1416. Cluster State Capabilities Name clusterStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.3 Description Defines the state capabilities of the cluster.
Table 1420. Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.7 Description Defines the description name for the type of the cluster. Syntax DellString Access Read-only Table 1421. Cluster Name Name clusterName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.8 Description Defines the name of the cluster.
Baseboard Management Controller Group 22 The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system.
, bmcIndex Table 1425. BMC Chassis Index Name bmcChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1426. BMC Index Name bmcIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.2 Description Defines the index (one-based) of the BMC. Syntax DellObjectRange Access Read-only Table 1427. BMC State Capabilities Name bmcStateCapabilities Object ID 1.3.6.1.4.1.674.10892.
Table 1430. BMC Display Name Name bmcDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.6 Description Defines the display name of the BMC. Syntax DellString Access Read-only Table 1431. BMC Description Name Name bmcDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.7 Description Defines the description of the BMC. Syntax DisplayString (SIZE (0..255)) Access Read-only Table 1432. BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.
Description Defines the module name for the BMC. The module name is present only on certain systems, such as modular systems. Syntax DellString Access Read-only Table 1436. BMC IPv4 URL Name Name bmcIPv4URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.12 Description Defines the IPv4 URL for the BMC. The URL is not present on all systems. Syntax DisplayString (SIZE (0..1024)) Access Read-only Table 1437. BMC IPv6 URL Name Name bmcIPv6URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.
, bmcSerialInterfaceIndex Table 1440. BMC Serial Interface Chassis Index Name bmcSerialInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1441. BMC Serial Interface BMC Index Name bmcSerialInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.2 Description Defines the index (one-based) of the associated BMC.
Table 1445. BMC Serial Interface Status Name bmcSerialInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.6 Description Defines the status of the BMC serial interface. Syntax DellStatus Access Read-only Table 1446. BMC Serial Interface Channel Number Name bmcSerialInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.7 Description Defines the BMC channel number of the BMC serial interface. Syntax DellUnsigned8BitRange Access Read-only Table 1447.
Description Defines the bit rate of the BMC serial interface. Syntax DellBMCSerialBitRateType Access Read-only Baseboard Management Controller LAN Interface Table Table 1451. BMC LAN Interface Name bmcLANInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.30 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table. Syntax SEQUENCE OF BmcLANInterfaceTableEntry Access Not accessible Table 1452.
Access Read-only Table 1455. BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3 Description Defines the index (one-based) of the BMC LAN interface. Syntax DellObjectRange Access Read-only Table 1456. BMC LAN Interface State Capabilities Name bmcLANInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.4 Description Defines the state capabilities of the BMC LAN interface.
Table 1460. BMC LAN Interface IP Address Source Name bmcLANInterfaceIPAddressSource Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.8 Description Defines the source type of the IP address of the BMC LAN interface. Syntax DellBMCLANIPAddressSourceType Access Read-only Table 1461. BMC LAN Interface IP Address Name bmcLANInterfaceIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.9 Description Defines the IP address of the BMC LAN interface. Syntax IpAddress Access Read-only Table 1462.
Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface. Syntax DisplayString (SIZE (0..32)) Access Read-only Baseboard Management Controller Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 1466. Baseboard Management Controller Variable Name:DellBMCSerialConnectionModeCapabilities Data Type:Integer These values are bit masks; therefore, combination values are possible.
Table 1468. BMC Serial Flow Control Type Variable Name:DellBMCSerialFlowControlType Data Type:Integer Possible Data Values Meaning of Data Value -- none(0) No flow control used. rtscts(1) RTS/CTS (hardware) flow control used. xonXoff(2) XON/XOFF flow control used. Table 1469.
iDRAC6(10) Controller type is Integrated Dell Remote Access Controller 6. iDRAC6Modular(11) Controller type is Integrated Dell Remote Access Controller 6 (Modular). iDRAC6BMC(13) Controller type is Integrated Dell Remote Access Controller 6 (BMC mode). iDRAC7(16) Controller type is Integrated Dell Remote Access Controller 7. iDRAC7Modular(17) Controller type is Integrated Dell Remote Access Controller 7 (Modular).
Field Replaceable Unit Group 23 A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system. Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field replaceable units. The following MIB tables define the FRU group.
Table 1475. FRU Index Name fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2 Description Defines the index (one-based) of the FRU. Syntax DellObjectRange Access Read-only Table 1476. FRU Information Status Name fruInformationStatus Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.3 Description Defines the status of the FRU table entry. Syntax DellStatus Access Read-only Table 1477. FRU Information State Name fruInformationState Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.
Description Defines the serial number of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1481. FRU Part Number Name Name fruPartNumberName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.8 Description Defines the part number of the FRU Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1482. FRU Revision Name Name fruRevisionName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9 Description Defines the revision of the FRU. Syntax DisplayString (SIZE (0..
Possible Data Values Meaning of Data Value ok(1) FRU information is okay. notSupported(2) FRU information is not supported. notAvailable(3) FRU information is not available. checksumInvalid(4) FRU information checksum is invalid. corrupted(5) FRU information is corrupted.
Storage Management Group 24 The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software. • Storage Management Event Group—SNMP traps.
Table 1488. Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.3 Description Identifies the manufacturer of the Storage Management software. Syntax DisplayString Access Read-only Table 1489. Software Product Name softwareProduct Object ID 1.3.6.1.4.1.674.10893.1.20.4 Description Identifies product information for the Storage Management software. Syntax DisplayString Access Read-only Table 1490.
Syntax DisplayString Access Read-only Table 1493. Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.3 Description Identifies the name of the management software manufacturer. Syntax DisplayString Access Read-only Table 1494. Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.4 Description This entry is obsolete. Refer to softwareVersion.
Table 1497. Agent Time Stamp Name agentTimeStamp Object ID 1.3.6.1.4.1.674.10893.1.20.110.3 Description Identifies the last time that the agent values have been updated. Universal time in seconds since UTC 1/1/70. Syntax Integer Access Read-only Table 1498. Agent Get Timeout Name agentGetTimeout Object ID 1.3.6.1.4.1.674.10893.1.20.110.4 Description Indicates the suggested timeout value in milliseconds for how long the SNMP getter should wait while attempting to poll the SNMP agent.
Access Read-only Table 1502. Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.8 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1503. Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.9 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1504. Agent SNMP Version Name agentSnmpVersion Object ID 1.3.6.1.4.1.674.
Access Read-only Table 1507. Agent Global System Status Name agentGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.13 Description Global health information for the subsystem managed by the Storage Management software. This global status should be used by applications other than HP OpenView. HP OpenView should refer to the globalStatus in the root level object group. This is a rollup for the entire agent including any monitored devices.
Description Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S enclosures. Possible values: 1: Enabled 2: Disabled 3: Not applicable Syntax Integer Access Read-only Physical Devices Group The Physical Devices MIB group provides information about the devices managed by the Storage Management software and their relationships to each other. The following MIB tables define objects and relationships (connections) among the objects.
The following object sets up the Controller Table. Table 1510. Controller Table Name controllerTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.1 Description Defines the controller table, which is a table of managed Redundant Array of Independent disks (RAID) controllers. The number of entries is related to the number of RAID controllers discovered in the system. Syntax SEQUENCE OF ControllerEntry Access Not accessible Table 1511. Controller Entry Name controllerEntry Object ID 1.3.6.1.4.1.674.
Table 1514. Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's (re)seller's name. Syntax DisplayString Access Read-only Table 1515. Controller Type Name controllerType Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Name controllerRebuildRateInPercent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.7 Description Identifies the percent of the compute cycles dedicated to rebuilding failed array disks. Syntax Integer Access Read-only Table 1518. Controller Firmware Version Name controllerFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1521. Controller Physical Device Count Name controllerPhysicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.11 Description Identifies the number of physical devices on the controller channel including both disks and the controller. Syntax Integer Access Read-only Table 1522. Controller Logical Device Count Name controllerLogicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.12 Description Identifies the number of virtual disks on the controller.
Table 1526. Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16 Description Identifies the size of memory on the controller that is less than a megabyte. This combined with the controllerMemorySizeInMB is the total size of the memory. This attribute is only supported on Adaptec controllers. Syntax Integer Access Read-only Table 1527. Controller Drive Channel Count Name controllerDriveChannelCount Object ID 1.3.6.1.4.1.674.10893.1.
Table 1531. Controller C0 Port 0 ID Name controllerC0Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1532. Controller C0 Target Name controllerC0Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.22 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1533.
Table 1536. Controller C1 Port 0 World Wide Name Name controllerC1Port0WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.26 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1537. Controller C1 Port 0 Name Name controllerC1Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.27 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Table 1541. Controller C1 Operating System Controller Name controllerC1OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1542. Controller Battery State C1 Name controllerC1BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.32 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Table 1546. Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1547. Controller Roll-Up Status Name controllerRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.37 Description Indicates severity of the controller state. This is the combined status of the controller and its components.
Description Durable unique ID for this controller. Syntax DisplayString Access Read-only Table 1550. Controller Alarm State Name controllerAlarmState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40 Description Indicates state, or setting for the controller's alarm. Possible values: 1: Enabled 2: Disabled 3: Not Applicable Syntax Integer Access Read-only Table 1551. Controller Driver Version Name controllerDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
99: Not Applicable Syntax Integer Access Read-only Table 1554. Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.44 Description The minimum firmware version for Storage Management to support the controller. Syntax DisplayString Access Read-only Table 1555. Controller Minimum Driver Version Name controllerMinDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Syntax Integer Access Read-write Table 1559. Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.49 Description The rate for patrol read on the controller. Syntax Integer Access Read-only Table 1560. Controller BGI Rate Name controllerBGIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.50 Description The rate for background initialization on the controller. Syntax Integer Access Read-only Table 1561.
1: Stopped - not running 2: Ready - ready to start 4: Active - is running 8: Aborted - has aborted Syntax Integer Access Read-only Table 1564. Controller Patrol Read Iterations Name controllerPatrolReadIterations Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.54 Description The number of times Patrol Read has been run on this controller. Syntax Integer Access Read-only Table 1565. Controller Storport Driver Version Name controllerStorportDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.
Name controllerEncryptionKeyPresent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.58 Description Indicates presence of encryption key for the controller. Value: 1 - Yes, 0 - No, 99 - Not Applicable Syntax Integer Access Read-only Table 1568. Controller Persistent Hot Spare Name controllerPersistentHotSpare Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.59 Description Indicates Persistent Hot Spare capability of the controller.
Syntax Integer Access Read-write Table 1572. Controller Encryption Mode Name controllerEncryptionMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.63 Description Indicates the current encryption mode of the controller. Value: 0 - No Encryption, 1 - Local Key Management (LKM), 2 - Dell Key Management (DKM), 99 - Not Applicable Syntax Integer Access Read-only Table 1573. Controller CacheCade Name controllerCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1576. Controller Configured Drives SpinUp Time Name controllerConfiguredDrivesSpinUpTime Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.67 Description Indicates configured drives spin up start time. Value: 1:00 AM to 12:59 PM, 9999 Undetermined Syntax DisplayString Access Read-only Table 1577. Controller Configured Drives SpinUp TimeInterval Name controllerConfiguredDrivesSpinUpTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Access Not accessible Table 1580. Channel Entry Name channelEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1 Description Defines the channel table entry. Syntax ChannelEntry Access Not accessible Index channelNumber Table 1581. Channel Number Name channelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.1 Description Identifies the instance number of the channel entry. Syntax Integer Access Read-only Table 1582. Channel Name Name channelName Object ID 1.3.6.1.4.1.674.10893.
Access Read-only Table 1584. Channel Severity Name channelSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1585. Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on this channel.
5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1588. Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8 Description The status of the channel itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1589. Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.
Possible values: 1: SCSI 2: IDE 3: Fibre Channel 4: Serial Storage Architecture (SSA) 6: Universal Serial Bus (USB) 7: SATA 8: SAS 9: PCIe Syntax Integer Access Read-only Enclosure Table This table describes available properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Table 1592. Enclosure Table Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table.
Table 1595. Enclosure Name Name enclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2 Description Identifies the enclosure's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1596. Enclosure Vendor Name enclosureVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.3 Description Identifies the enclosure's (re)seller's name. Syntax DisplayString Access Read-only Table 1597. Enclosure State Name enclosureState Object ID 1.3.6.1.4.1.674.10893.
Table 1599. Enclosure ID Name enclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6 Description Represents unique id for an enclosure. Syntax DisplayString Access Read-only Table 1600. Enclosure Processor Version Name enclosureProcessorVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1601. Enclosure Service Tag Name enclosureServiceTag Object ID 1.3.6.1.4.1.674.10893.1.
Table 1604. Enclosure Split Bus Part Number Name enclosureSplitBusPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.11 Description Identifies the enclosure's split bus part number. Syntax DisplayString Access Read-only Table 1605. Enclosure Product ID Name enclosureProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.12 Description Identifies the enclosure's product identification. This also corresponds to the enclosure type. Syntax DisplayString Access Read-only Table 1606.
Table 1609. Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure. Possible values: 1: Internal 2: Dell PowerVault 200S (PowerVault 201S) 3: Dell PowerVault 210S (PowerVault 211S) 4: Dell PowerVault 220S (PowerVault 221S) 5: Dell PowerVault 660F 6: Dell PowerVault 224F 7: Dell PowerVault 660F/PowerVault 224F 8: Dell MD1000 9: Dell MD1120 Syntax DisplayString Access Read-only Table 1610.
Syntax Integer Access Read-only Table 1613. Enclosure Alarm Name enclosureAlarm Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20 Description Identifies the current status of the enclosure's alarm (PowerVault 220S and PowerVault 221S only.) Possible values: 1: Disabled 2: Enabled Syntax Integer Access Read-only Table 1614. Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
6: Non-recoverable Syntax DellStatus Access Read-only Table 1617. Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24 Description The status of the enclosure itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1618. Enclosure Nexus ID Name enclosureNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.
Access Read-only Table 1621. Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28 Description The part number of the enclosure. Syntax DisplayString Access Read-only Table 1622. Enclosure Serial Number Name enclosureSerialNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.29 Description Serial number of the enclosure. Syntax DisplayString Access Read-only Table 1623. Enclosure SAS Address Name enclosureSASAddress Object ID 1.3.6.1.4.1.
NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-only Table 1626. Enclosure Empty Slot Count Name enclosureEmptySlotCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.33 Description Shows the number of empty physical disk slots in a storage enclosure.
Access Read-only Table 1630. Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 Description Identifies the name of the array disk as represented in Storage Management. Syntax DisplayString Access Read-only Table 1631. Array Disk Vendor Name arrayDiskVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3 Description The array disk's manufacturer's name. Syntax DisplayString Access Read-only Table 1632. Array Disk State Name arrayDiskState Object ID 1.
39: Foreign 40: Clear 41: Unsupported 53: Incompatible 56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached read-only state. Syntax Integer Access Read-only Table 1633. Array Disk Severity Name arrayDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1634.
Table 1637. Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs. Syntax DisplayString Access Read-only Table 1638. Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 y Description Identifies the bus to which this array disk is connected. Syntax Integer Read-onl Access Table 1639.
Access Read-only Table 1642. Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.14 Description The size of the largest contiguous free space on this array disk in bytes that is less than a megabyte.This size plus the arrayDiskLargestContiguousFreeSpaceInMB is the total size of the largest contiguous free space on the array disk. Syntax Integer Access Read-only Table 1643.
Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte. This size plus the arrayDiskUsedSpaceInMB is the total amount of used space on the array disk. Syntax Integer Access Read-only Table 1647. Array Disk Free Space in Megabytes Name arrayDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.19 Description Identifies the amount in megabytes of the free space on the array disk. If this size is 0, it is smaller than a megabyte.
Table 1650. Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare. Possible states: 1: Disk is a member of a virtual disk 2: Disk is a member of a disk group 3: Disk is a global hot spare 4: Disk is a dedicated hot spare 5: Not a spare 99: Not applicable Syntax Integer Access Read-only Table 1651. Array Disk Roll-Up Status Name arrayDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.
Syntax DellStatus Access Read-only Table 1653. Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.25 Description Identifies the operating system device name for this disk. Syntax DisplayString Access Read-only Table 1654. Array Disk Nexus ID Name arrayDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.26 Description Indicates the durable unique ID for this array disk. Syntax DisplayString Access Read-only Table 1655.
Syntax Integer Access Read-only Table 1658. Array Disk Capable Speed Name arrayDiskCapableSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.30 Description Indicates the maximum speed at which the drive is capable of negotiating in MPS (megabytes per second). Syntax Integer Access Read-only Table 1659. Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Table 1662. Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 Description Indicates the four digit year in which this disk was manufactured. Syntax DisplayString Access Read-only Table 1663. Array Disk Media Type Name arrayDiskMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35 Description The Media type of the array disk. Possible Values: 1:unknown 2:hdd 3:ssd Syntax INTEGER Access Read-only Table 1664.
Syntax Octet String Access Read-only Table 1667. Array Disk Alta Revision Id Name arrayDiskAltaRevisionId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.39 Description Provides revision ID for Alta interposer. Syntax Octet String Access Read-only Table 1668. Array Disk Encryption Capable Name arrayDiskEncryptionCapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.40 Description Indicates if physical disk is encryption capable.
Description Indicates drive write cache capability for PCIe SSD devices. Value: 1 - Enabled, 0 Disabled, 99 - Undetermined/NotApplicable Syntax Integer Access Read-only Table 1672. Array Disk Model Number Name arrayDiskModelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.44 Description Provides PCIe SSD device model number. Syntax DisplayString Access Read-only Table 1673. Array Disk Life Remaining Name arrayDiskLifeRemaining Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Syntax INTEGER Access Read-only Array Disk Enclosure Connection Table This table describes the connections among array disks, their enclosure, and their associated controller. For each object in the table, its object number corresponds to an instance number in the appropriate MIB table for that object where all of the object properties can be found. NOTE: Only array disks that are part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management.
Description Identifies the name of the array disk in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1680. Array Disk Enclosure Connection Array Disk Number Name arrayDiskEnclosureConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.3 Description Identifies the instance number of the array disk in the arrayDiskTable in this connection. Syntax Integer Access Read-only Table 1681.
Table 1684. Array Disk Enclosure Connection Controller Number Name arrayDiskEnclosureConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.7 Description Identifies the instance number in the controllerTable of the controller to which this array disk is connected. Syntax Integer Access Read-only Array Disk Channel Connection Table This table describes the connections between array disks, their channel, and their associated controller.
Access Read-only Table 1688. Array Disk Channel Connection Array Disk Name Name arrayDiskChannelConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.2 Description Identifies the name of the array disk in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1689. Array Disk Channel Connection Array Disk Number Name arrayDiskChannelConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.
Description Identifies the name of the controller as represented in Storage Management to which this array disk is connected. Syntax DisplayString Access Read-only Table 1693. Array Disk Channel Connection Controller Number Name arrayDiskChannelConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.7 Description Identifies the instance number in the controllerTable of the controller to which this array disk is connected.
Syntax Integer Access Read-only Table 1697. Fan Name Name Fan Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.2 Description Identifies the fan's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1698. Fan Vendor Name fanVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.3 Description Identifies the fan's (re)seller's name. Syntax DisplayString Access Read-only Table 1699. Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.
Access Read-only Table 1701. Fan Probe Unit Name fanProbeUnit Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.6 Description This entry is obsolete for Storage Services. Syntax DisplayString Access Read-only Table 1702. Fan Probe Minimum Warning Name fanProbeMinimumWarning Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.7 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1703.
Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1706. Fan Probe Current Value Name fanProbeCurrValue Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.11 Description Identifies the current speed of the fan. Syntax DisplayString Access Read-only Table 1707. Fan1 Part Number Name fan1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.
6: Non-recoverable Syntax DellStatus Access Read-only Table 1710. Fan Component Status Name fanComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.15 Description The status of the fan itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1711. Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.
Table 1713. Fan Connection Table Name fanConnectionTable Object ID fanConnectionTable Description Defines the fan connection table. Syntax SEQUENCE OF FanConnectionEntry Access Not accessible Table 1714. Fan Connection Entry Name fanConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1 Description Defines the fan connection table entry. Syntax FanConnectionEntry Access Not accessible Index fanConnectionNumber Table 1715.
Access Read-only Table 1718. Fan Connection Enclosure Name Name fanConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this fan belongs. Syntax DisplayString Access Read-only Table 1719. Fan Connection Enclosure Number Name fanConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1723. Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Table 1724. Power Supply State Capabilities Unique Name powerSupplyStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.3 Description Defines the capabilities of the power supply.
Access Read-only Table 1728. Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerSupplyType (Power Supply Type Definitions) Access Read-only Table 1729. Power Supply Location Name Name powerSupplyLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.8 Description Defines the location name of the power supply. Syntax DellString Access Read-only Table 1730.
Table 1733. Power Supply Configuration Error Type Name powerSupplyConfigurationErrorType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.12 Description Defines the type of configuration error reported by the power supply sensor. Syntax DellPowerSupplyConfigurationErrorType (Power Supply Configuration Error Type) Access Read-only Table 1734. Power Supply Power Monitor Capable Name powerSupplyPowerMonitorCapable Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
Syntax PowerSupplyConnectionEntry Access Not accessible Index powerSupplyConnectionNumber Table 1738. Power Supply Connection Number Name powerSupplyConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.1 Description Identifies the instance number of the power supply connection entry. Syntax Integer Access Read-only Table 1739. Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.
Table 1742. Power Supply Connection Enclosure Number Name powerSupplyConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this power supply belongs. Syntax Integer Access Read-only Table 1743. Power Supply Connection Firmware Version Name powerSupplyConnectionFirmwareVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.
Table 1746. Temperature Probe Chassis Index Name temperatureProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1747. Temperature Probe Index Name temperatureProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.2 Description Defines the index of temperature probes in this chassis. Syntax DellObjectRange Access Read-only Table 1748.
Description Defines the value of the temperature probe. When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, the value returned for this attribute is the temperature that the probe is reading in tenths of degrees Centigrade. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Table 1752. Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.
Description Defines the user-assigned value of the temperature probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 1757. Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.12 Description Defines the user-assigned value of the temperature probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 1758.
When the value for temperatureProbeType is other than temperatureProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for temperatureProbeType is temperatureProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.
Description Identifies the name of the temperature probe in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1766. Temperature Probe Connection Temperature Probe Number Name temperatureConnectionTemperatureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.3 Description Identifies the instance number in the temperatureTable of the temperature probe in this connection. Syntax Integer Access Read-only Table 1767.
Syntax SEQUENCE OF EnclosureManagementModuleEntry Access Not accessible Table 1770. Enclosure Management Module Entry Name EnclosureManagementModuleEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1 Description Defines the enclosure management module table entry. Syntax EnclosureManagementModuleEntry Access Not accessible Index enclosureManagementModuleNumber Table 1771. Enclosure Management Module Number Name enclosureManagementModuleNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.
Description Identifies the current state of the enclosure management module. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 5: Not Installed 6: Degraded 21: Missing Syntax Integer Access Read-only Table 1775. Enclosure Management Module Severity Name enclosureManagementModuleSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device.
Table 1778. Enclosure Management Module Firmware Version Name enclosureManagementModuleFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.8 Description Identifies the firmware version of the enclosure memory module. Syntax DisplayString Access Read-only Table 1779. Enclosure Management Module Maximum Speed Name enclosureManagementModuleMaxSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.9 Description Identifies the maximum bus speed of the enclosure management module.
5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1782. Enclosure Management Module Nexus ID Name enclosureManagementModuleNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.12 Description Durable unique ID for this EMM. Syntax DisplayString Access Read-only Table 1783. Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
Index enclosureManagementModuleConnectionNumber Table 1786. Enclosure Management Module Connection Number Name enclosureManagementModuleConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.1 Description Identifies the instance number of the enclosure memory module connection entry. Syntax Integer Access Read-only Table 1787. Enclosure Management Module Connection EMM Name Name enclosureManagementModuleConnectionEMMName Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.
Description Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs. Syntax Integer Access Read-only Battery Table Table 1791. Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Table 1792. Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.
Description Defines the state capabilities of the battery. Syntax DellStateCapabilities Access Read-only Table 1796. Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-write Table 1797. Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Description Defines the status of the battery.
Table 1800. Battery Connection Table Name batteryConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.16 Description Defines the battery connection table. Syntax SEQUENCE OF BatteryConnectionEntry Access Not accessible Table 1801. Battery Connection Entry Name batteryConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1 Description Defines the battery connection table entry.
Access Read-only Table 1805. Battery Connection Controller Name Name batteryConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.4 Description Identifies the name of the controller as represented in Storage Management to which this battery belongs. Syntax DisplayString Access Read-only Table 1806. Battery Connection Controller Number Name batteryConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.
Access Not accessible Table 1809. Tape Drive Number Name tapeDriveNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.1 Description Instance number of this tape drive entry. Syntax INTEGER Access Read-only Table 1810. Tape Drive Name Name tapeDriveName Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.2 Description The name of the tape drive as represented in Storage Management. Syntax DisplayString Access Read-only Table 1811. Tape Drive Vendor Name tapeDriveVendor Object ID 1.3.6.
Access Read-only Table 1814. Tape Drive Bus Type Name tapeDriveBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.6 Description The bus type of the tape drive. Possible values: 8. SAS Syntax INTEGER Access Read-only Table 1815. Tape Drive SAS Address Name tapeDriveSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.7 Description The specified SAS address if this is a SAS tape drive. Syntax DisplayString Access Read-only Table 1816.
Table 1817. Virtual Disk Table Name virtualDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.1 Description Defines the virtual disk table. Syntax SEQUENCE OF VirtualDiskEntry Access Not accessible Table 1818. Virtual Disk Entry Name virtualDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1 Description Defines the virtual disk table entry. Syntax VirtualDiskEntry Access Not accessible Index virtualDiskNumber Table 1819. Virtual Disk Number Name virtualDiskNumber Object ID 1.
Access Read-only Table 1822. Virtual Disk State Name virtualDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4 Description Identifies the current state of this virtual disk. Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems. 2: Failed - The data on the virtual disk is no longer fault tolerant because one of the underlying disks is not online. 3: Online 4: Offline - The disk is not accessible. The disk may be corrupted or intermittently unavailable.
Syntax Integer Access Read-only Table 1825. Virtual Disk Length in Bytes Name virtualDiskLengthBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.7 Description Identifies the portion of the virtual disk in bytes that is smaller than a megabyte. This size plus the virtualDiskLengthInMB is the total size of the virtual disk. Syntax Integer Access Read-only Table 1826. Virtual Disk Free Space in Megabytes Name virtualDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
9: Not Applicable Syntax Integer Access Read-only Table 1829. Virtual Disk Read Policy Name virtualDiskReadPolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.11 Description Indicates whether the controller's read cache are used when reading from a virtual disk. Possible values: 1: Enabled - Adaptec Read Cache Enabled 2: Disabled - Adaptec Read Cache Disabled 3: LSI Read Ahead 4: LSI Adaptive Read Ahead 5: LSI No Read Ahead 9: Not Applicable Syntax Integer Access Read-only Table 1830.
Table 1832. Virtual Disk Current Stripe Size in Megabytes Name virtualDiskCurStripeSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.14 Description Identifies the stripe size of this virtual disk in megabytes. If this size is 0, it is smaller than a megabyte. Syntax Integer Access Read-only Table 1833. Virtual Disk Current Stripe Size in Bytes Name virtualDiskCurStripeSizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Syntax Integer Access Read-only Table 1837. Virtual Disk Roll-Up Status Name virtualDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.19 Description Severity of the virtual disk state. This is the combined status of the virtual disk and its components. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1838. Virtual Disk Component Status Name virtualDiskComponentStatus Object ID 1.3.6.1.4.1.674.
Table 1840. Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22 Description Identifies the type of array (physical) disks used to create the virtual disk. Possible values: 1: SAS 2: SATA 3: SCSI 4: IDE 99: Unknown Syntax Integer Access Read-only Table 1841. Virtual Disk Bad Blocks Detected Name virtualDiskBadBlocksDetected Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.23 Description Indicates if virtual disk has bad blocks.
Table 1844. Virtual Disk Disk Cache Policy Name virtualDiskDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.26 Description Indicates disk cache policy of the logical device. Value: 1 - Enabled, 2 - Disabled, 99 - Undetermined Syntax Integer Access Read-only Array Disk Logical Connection Table This table describes the connections between array disks, the virtual disk to which they belong, and their associated logical disk.
Table 1848. Array Disk Logical Connection Array Disk Name Name arrayDiskLogicalConnectionArrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.2 Description Identifies the name of the array disk in this logical connection. Syntax DisplayString Access Read-only Table 1849. Array Disk Logical Connection Array Disk Number Name arrayDiskLogicalConnectionArrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.
Table 1853. Array Disk Logical Connection Disk Number Name arrayDiskLogicalConnectionDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.7 Description Identifies the instance number of the disk group to which this array disk belongs. This property is currently not supported. Syntax Integer Access Read-only Storage Management Event Group The Storage Management Event Group defines the properties that are sent with SNMP traps. Table 1854. Message ID Event Name messageIDEvent Object ID 1.3.6.
Syntax DisplayString Access Read-only Table 1858. Object OID Event Name objectOIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.5 Description MIB OID of the object causing the alert. Syntax DisplayString Access Read-only Table 1859. Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Table 1860.
Change Management Group 25 The Change Management Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. Inventory Group The following objects describe the fields for inventory information. Table 1862. Inventory Locale Name inventoryLocale Object ID 1.3.6.1.4.1.674.10899.1.1 Description Defines the locale of the system.
Table 1865. Device Table Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table. Syntax SEQUENCE OF DeviceEntry Access Not accessible Table 1866. Device Entry Name deviceEntry Object ID 1.3.6.1.4.1.674.10899.1.5.1 Description Defines a device entry. Syntax DeviceEntry Access Not accessible Table 1867. Device Index Name deviceIndex Object ID 1.3.6.1.4.1.674.10899.1.5.1.1 Description Defines the unique index for this device.
Description Defines the ID for the vendor supplying the device. Syntax Octet String Access Read-only Table 1871. Device ID Name deviceDeviceID Object ID 1.3.6.1.4.1.674.10899.1.5.1.5 Description Defines the ID for the device. Syntax Octet String Access Read-only Table 1872. Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.6 Description Provides additional device identification. Syntax Octet String Access Read-only Table 1873.
Syntax Defines a table of application information for the system. Access Not accessible Table 1875. Application Entry Name applicationEntry Object ID 1.3.6.1.4.1.674.10899.1.6.1 Description Defines an application entry. Syntax ApplicationEntry Access Read-only Table 1876. Application Index Name aplicationIndex Object ID 1.3.6.1.4.1.674.10899.1.6.1.1 Description Defines the unique index for this application. Syntax Unsigned16BitRange Access Read-only Table 1877.
Table 1880. Application Display String Name aplicationDisplayString Object ID 1.3.6.1.4.1.674.10899.1.6.1.5 Description A user visible display string that describes the application. Syntax DisplayString Access Read-only Table 1881. Application Sub-Component ID Name applicationSubComponentID Object ID 1.3.6.1.4.1.674.10899.1.6.1.6 Description The sub-component ID for the application. This is usually valid on ESM device reporting.
Dell Remote Access Controller Out-of-Band Group 26 The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB tables define the Dell RAC Out-of-Band group: Table 1882. DRsProductName Name DRsProductName Object ID 1.3.6.1.4.1.674.10892.2.1.1.1 Description Defines the product name of a chassis management controller.
Access Read-only Table 1886. DRsProductVersion Name DRsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only Table 1887. DRsChassisServiceTag Name DRsChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.6 Description Defines the Service Tag of the chassis. Syntax DellString Access Read-only Table 1888. DRsProductURL Name DrsProductURL Object ID 1.3.6.1.4.1.674.10892.
Table 1891. DRsProductChassisName Name DRsProductChassisName Object ID 1.3.6.1.4.1.674.10892.2.1.1.10 Description Defines the name of the chassis. Syntax DellString Access Read-only Table 1892. DRsSystemServiceTag Name DRsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only Table 1893. DRsProductSystemAssetTag Name DRsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Description Defines the firmware version of a chassis management controller. Syntax DellString Access Read-only Chassis Status The following MIB tables provide information on Chassis being monitored by the chassis management card. Table 1897. DRsGlobalSystemStatus Name DRsGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10892.2.2.1 Description Defines the overall chassis status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1898.
Table 1901. DRsRedCurrStatus Name DRsRedCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.4 Description Defines the redundancy status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1902. DRsPowerCurrStatus Name DRsPowerCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.5 Description Defines the power subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1903.
Table 1906. DRsCMCCurrStatus Name DRsCMCCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.9 Description Defines the CMC health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1907. DRsChassisFrontPanelAmbientTemperature Name drsChassisFrontPanelAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.10 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller.
Table 1911. DRsIOMPrevStatus Name DRsIOMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.2 Description Defines the previous IOM subsystem status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 1912. DRsKVMPrevStatus Name DRsKVMPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.3 Description Defines the previous iKVM subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 1913.
Table 1916. DRsBladePrevStatus Name DRsBladePrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.7 Description Defines the previous blade subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 1917. DRsTempPrevStatus Name DRsTempPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.8 Description Defines the temperature sensor health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1918.
Table 1921. DRsKVMChangeTime Name DRsKVMChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.3 Description Defines the timestamp of the most recent iKVM status change. Syntax TimeTicks Access Read-only Table 1922. DRsRedChangeTime Name DRsRedChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.4 Description Defines the timestamp of the most recent Redundancy status change. Syntax TimeTicks Access Read-only Table 1923. DRsPowerChangeTime Name DRsPowerChangeTime Object ID 1.3.6.1.4.1.674.
Description Defines the timestamp of the most recent temperature sensor health status change. Syntax TimeTicks Access Read-only DRsCMCChangeTime Name DRsCMCChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.9 Description Defines the timestamp of the most recent CMC health status change. Syntax TimeTicks Access Read-only Chassis Power The following MIB tables provide information on the chassis management controller table entry. Table 1927.
Table 1930. DRsCMC PSUTableEntry Name DrsCMCPSUTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.2.1 Description Defines the CMC PSU table entry. Syntax DrsCMCPSUTableEntry Access Not-accessible CMC Power Information The following MIB tables provide information on the chassis power. Table 1931. DRsChassisIndex Name DrsChassisIndex Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.1 Description Defines the index (one-based) of the associated chassis.
Table 1935. DRsPowerSurplus Name DRsPowerSurplus Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.5 Description Defines the power surplus (in Watts) remaining above the drsPotentialPower reading. Syntax DellPowerReading Access Read-only Table 1936. DRsKWhCumulative Name DRsKWhCumulative Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.6 Description Defines the cumulative chassis power usage (in KWh) since last reset. Syntax DellPowerReading Access Read-only Table 1937.
Description Defines the chassis minimum power usage (in Watts) since last reset. Syntax DellPowerReading Access Read-only Table 1941. DRsWattsMinTime Name DRsWattsMinTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.11 Description Defines the timestamp of the most recent chassis minimum power usage. Syntax DellPowerReading Access Read-only Table 1942. DRsWattsResetTime Name DRsWattsResetTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
Description Defines the index (one-based) of the associated chassis. Syntax DellCMCPowerIndexRange Access Read-only Table 1946. DRsPSUIndex Name DRsPSUIndex Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.2 Description Defines the index (one-based) of the associated CMC PSU. Syntax DellCMCPSUIndexRange Access Read-only Table 1947. DRsPSULocation Name DRsPSULocation Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.3 Description Defines the location of the CMC PSU.
Table 1951. DRsPSUWattsReading Name DRsPSUWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.7 Description Defines the instantaneous PSU Wattage reading. Syntax DellPowerReading Access Read-only Chassis Alert The following MIB tables provide information on the chassis management controller alerts. Table 1952. DRsCASubSystem Name DRsCASubSystem Object ID 1.3.6.1.4.1.674.10892.2.20.10.1 Description Defines the Sub-System Name of the CMC Alert.
Table 1956. DrsCAMessage Name DrsCAMessage Object ID 1.3.6.1.4.1.674.10892.2.20.10.5 Description Defines the CSSD message of the CMC Alert. Syntax DellString Access Read-only Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. Table 1957. DRsAlertSystem Name DRsAlertSystem Object ID 1.3.6.1.4.1.674.10892.2.5000.10.1 Description Name of the system generating the alert. Syntax Octet String(SIZE (0..255)) Access Read-only Table 1958.
Table 1961. DRsAlertPreviousStatus Name DRsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5 Description Previous status of object causing the alert. Syntax DellStatus Access Read-only Table 1962. DRsAlertData Name DRsAlertData Object ID 1.3.6.1.4.1.674.10892.2.5000.10.6 Description Alert data Syntax Octet String (SIZE (0..
27 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Table 1964. Table Index OID Variable Name alertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2 Description Specifies the object identifier for the index attribute in the table that contains the object causing the alert. Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object. Syntax OBJECT IDENTIFIER Table 1965. Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.1.5000.10.
Syntax DisplayString Table 1970. System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.4.5000.10.8 Description Specifies fully qualified domain name of the system generating the alert. Syntax DisplayString Table 1971. Service Tag Variable Name alertServiceTag Object ID 1.3.6.1.4.1.674.10892.4.5000.10.9 Description Specifies the system service tag of the system generating the alert. Syntax DisplayString Table 1972.
Description Line Item Explanation Chassis intrusion state: Specifies the chassis intrusion state (open or closed), for example: Chassis intrusion state: Open Chassis location: Specifies the name of the chassis that generated the message, for example: Chassis location: Main System Chassis Configuration error type: Specifies the type of configuration error that occurred, for example: Configuration error type: Revision mismatch Current s
Description Line Item Explanation Possible memory module event cause: Specifies a list of possible causes for the memory module event, for example: Possible memory module event cause: Single bit warning error rate exceeded Single bit error logging disabled Power Supply type: Specifies the type of power supply, for example: Power Supply type: VRM Pre-failure state was: Specifies the status of the previous memory message, for example: Pre-failure state wa
RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section Traps . The trap variables are sent in the order in which they are listed.
TrapID Name Description Severity Category Cause Supporte d by RAC Platform 1006 alertDrscPow The RAC has er On detected a system power state change to powered-on Information Error RAC detected a system power state change to power-on. DRAC III 1007 alertDrsc Event RAC has detected the system DRAC III watchdog expired (normally indicating a system hang).
TrapID Name Description Severity Category Cause Supporte d by RAC Platform DRAC III probe has detected a warning value 1014 alertDrscVolt Critical The RAC Critical voltage probe has detected a failure (or critical) value Error RAC voltage probe reading exceeded critical threshold.
TrapID Description Severity 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Information 131330 Under-Voltage Problem (Lower Critical - going low) Critical 131458 Under-Voltage Problem Cleared Information 131841 Generic Critical Voltage Problem Critical 131840 Generic Critical Voltage Problem Cleared Information 65792 Under-Temperature Warning (Lower non-critical, going low) Warning 65920 Under-Temperature Warning Cleared Information 65794
TrapID Description Severity 356224 Chassis Intrusion (Physical Security Violation) Event Cleared Information 262400 Generic Predictive Fan Failure (predictive failure asserted) Minor 262528 Generic Predictive Fan Failure Cleared Information 262402 Generic Critical Fan Failure Critical 262530 Generic Critical Fan Failure Cleared Information 264962 Fan redundancy has been degraded Warning 264961 Fan Redundancy Lost Critical 264960 Fan redundancy has returned to Normal Information 27
TrapID Description Severity 487306 CPU Throttle Cleared (Normal Processor Speed) Information 527106 Power Supply Redundancy Degraded Warning 527105 Power Supply Redundancy Lost Critical 527104 Power Supply Redundancy has returned to Normal Information 552704 Power Supply Inserted Information 552832 Power Supply Removed Warning 552705 Power Supply Failure Critical 552833 Power Supply Failure Cleared Information 552706 Power Supply Warning Warning 552834 Power Supply Warning Cle
Storage Management Alert Reference 28 Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up. If you stop the Disk Management Service, then alert monitoring and logging stops.
Table 1974. Storage Management Alert Severity Alert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation. Warning/Non-critical A component requires attention. This alert indicates a potential problem, but does not necessarily mean that the system has currently lost data or is nonfunctional.
Trap Variables The Storage Management SNMP traps use a set of variables that are included with every trap. Below mentioned variables are the Traditional Varbinds: Table 1975. Message ID Event Name messageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.1 Description Storage Management alert (event) message number. Syntax INTEGER Access Read-only Table 1976. Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
Syntax DisplayString Access Read-only Table 1980. Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Table 1981. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Current status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Table 1982.
Description Hostname of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 1985. Enhanced Service Tag Event Name serviceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.11 Description Service Tag of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 1986. Enhanced Chassis Service Tag Event Name chassisServiceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
iDRAC7 MIB 29 The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 7 (iDRAC7). This MIB provides management data that allows you to monitor devices and software on a system via an out-of-band connection to the iDRAC7 of a system. NOTE: As of iDRAC7 firmware release r1.30.30 (which corresponds to the release of Dell OpenManage Server Administrator Version 7.
SNMP Operations Supported SNMP version GET, GETNEXT, GETBULK SNMP v1 , v2c and v3 TRAP SNMP v1 and SNMP v2c NOTE: iDRAC7 does not support the SNMP SET operation for any data NOTE: As of iDRAC7 firmware release r1.30.30, iDRAC7 supports SNMP query operations (GET, GETNEXT, GETBULK) via the SNMPv3 protocol, in addition to supporting query operations via the SNMP v1 and SNMP v2c protocols. More specifically, iDRAC7 now supports the SNMP User Security Model (USM).
Description This attribute defines the product name of a remote access card. Syntax StringType Access Read-only Table 1988. RAC Name Name racShortName Object ID 1.3.6.1.4.1.674.10892.5.1.1.2.0 Description This attribute defines the short product name of a remote access card. Syntax StringType Access Read-only Table 1989. RAC Description Name racDescription Object ID 1.3.6.1.4.1.674.10892.5.1.1.3.0 Description This attribute defines the product description of a remote access card.
Table 1993. RAC Type Name racType Object ID 1.3.6.1.4.1.674.10892.5.1.1.7.0 Description This attribute defines the type of a remote access card. Syntax RacTypeEnum Access Read-only Table 1994. RAC Firmware Version Name racFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.8.0 Description This attribute defines the firmware version of a remote access card.
Description This attribute defines the service tag of the system. Syntax StringType Access Read-only Table 1998. System Express Service Code Name systemExpressServiceCode Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. Syntax StringType Access Read-only Table 1999. System Asset Tag Name systemAssetTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0 Description. This attribute defines the asset tag of the system.
Table 2003. System Data Center Name Name systemDataCenterName Object ID 1.3.6.1.4.1.674.10892.5.1.3.8.0 Description This attribute defines the Data Center locator of the system. Syntax StringType Access Read-only Table 2004. System Aisle Name Name systemAisleName Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.0 Description This attribute defines the Aisle locator of the system. Syntax StringType Access Read-only Table 2005. System Rack Name Name systemRackName Object ID 1.3.6.1.4.1.674.
Description This attribute defines the system ID of the system. Syntax Unsigned16BitRange Access Read-only Table 2009. System OS Version Name systemOSVersion Object ID 1.3.6.1.4.1.674.10892.5.1.3.14.0 Description This attribute defines the version of the operating system that the host is running. Syntax StringType Access Read-only Table 2010. System Room Name Name systemRoomName Object ID 1.3.6.1.4.1.674.10892.5.1.3.15.
Table 2013. Global System Status Name globalSystemStatus Object ID 1.3.6.1.4.1.674.10892.5.2.1.0 Description This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only Table 2014. System LCD Status Name systemLCDStatus Object ID 1.3.6.1.4.1.674.10892.5.2.2.0 Description This attribute defines the system status as it is reflected by the LCD front panel.
NOTE: See the iDRAC7 MIB file for details of the tables supported under the Storage Details Group. iDRAC7 Traps The iDRAC7 generates events that result in Simple Network Management Protocol (SNMP) traps and/or entries in the iDRAC7 Lifecycle Log. This section describes the traps, also known as alerts, generated by the iDRAC7. The iDRAC7 generates events in response to changes in the status of sensors and other monitored parameters.
Syntax StringType Table 2019. Alert Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.5.3.1.3.0 Description Current status of object causing the alert, if applicable. Syntax ObjectStatusEnum Access Read-only Table 2020. Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.4.0 Description Service tag of the system. Syntax DisplayString (SIZE (0..16)) Table 2021.
the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes. Syntax StringType Table 2025. Alert Chassis Service Tag Variable Name alertChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.9.0 Description For blade systems, the service tag of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length). Syntax DisplayString (SIZE (0..
TrapID Description Category SubCategory Severity Battery is low. System Health Battery Event Minor Battery has failed or battery is absent. System Health Battery Event Critical Category SubCategory Severity System Health Processor Informational Processor device status has detected a warning. System Health Processor Minor Processor device status has detected a failure. System Health Processor Critical Description Category SubCategory Severity Processor device is absent.
TrapID Description Category SubCategory Severity Fiber Channel warning. System Health Fiber Channel Minor Fiber Channel failure or critical event. System Health Fiber Channel Critical Category SubCategory Severity System Health Hardware Config Informational System Health Hardware Config Minor System Health Hardware Config Critical Description Category SubCategory Severity Memory device informational event.
TrapID Description Category SubCategory Severity 2089 Network failure or critical event. System Health NIC Config Critical SubCategory Severity An OS graceful stop occurred; or System Health an OS graceful shut-down occurred. OS Event Informational A critical stop occurred during OS load; or a runtime critical stop occurred. System Health OS Event Critical Description Category SubCategory Severity An informational event was detected for a PCI device.
Table 2039. BIOS POST Trap TrapID Description Category SubCategory Severity System BIOS detected a failure. System Health BIOS POST Critical Description Category SubCategory Severity Power supply has returned to normal. System Health Power Supply Informational Power supply has detected a warning. System Health Power Supply Minor Power supply has detected a failure. System Health Power Supply Critical Description Category SubCategory Severity Power supply is absent.
Table 2043. Redundancy Traps TrapID Description Category SubCategory Severity Redundancy information. System Health Redundancy Informational Redundancy is degraded. System Health Redundancy Minor Redundancy is lost.
TrapID Description Category SubCategory Severity 2489 Integrated Dual SD Module redundancy is lost. System Health IDSDM Redundancy Critical Description Category SubCategory Severity Security information. System Health Security Event Informational Security failure or critical event. System Health Security Event Critical Table 2047. Security Event Traps TrapID Security Information 2387 Security Failure 2385 Table 2048.
TrapID Description Category SubCategory Severity Temperature Statistics Critical Category SubCategory Severity vFlash Media device information. System Health vFlash Event Informational vFlash Media device warning. System Health vFlash Event Minor vFlash Media device failure. System Health vFlash Event Critical Description Category SubCategory Severity vFlash Media device is absent.
Storage Trap Group The Storage Trap Group contains traps that fall under the Storage event category of iDRAC7. Storage traps are traps generated in response to events related to the external storage subsystem of the system in which iDRAC7 resides. Table 2054. Battery Traps TrapID Description Category SubCategory Severity Battery state has returned to normal; or battery presence has been detected. Storage Battery Event Informational Battery is low.
TrapID Description Category SubCategory Severity 4202 Fan warning. Storage Fan Event Minor Fan failure. Storage Fan Event Critical Description Category SubCategory Severity Storage Physical Disk Informational Physical disk warning. Storage Physical Disk Minor Physical disk failure. Storage Physical Disk Critical Description Category SubCategory Severity Storage Power Supply Informational Power supply warning. Storage Power Supply Minor Power supply failure.
Table 2061. Temperature Probe Traps TrapID Description Category SubCategory Severity Storage Temperature Informational Storage Temperature Minor Temperature probe failure. Storage Temperature Critical Description Category SubCategory Severity Virtual disk information. Storage Virtual Disk Informational Virtual disk warning. Storage Virtual Disk Minor Virtual disk failure. Storage Virtual Disk Critical Storage Temperature Probe Information 4211 Temperature probe information.
Table 2064. iDRAC IP Address Change Trap TrapID Description Category SubCategory Severity iDRAC IP address has changed. Audit DRAC IP Address Informational Description Category SubCategory Severity License information. Audit Licensing Informational License warning. Audit Licensing Minor License failure. Audit Licensing Critical Category SubCategory Severity Audit System Info Informational iDRAC IP Address Change 8499 Table 2065.
Standard Data Type Definitions 30 This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib , dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
unknownCapabilities(1) The object’s capabilities are unknown. enableCapable(2) The object can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The object is not ready. enableAndNotReadyCapable (6) Enable and not ready capable. Table 2069. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled.
ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical. critical(5) The object’s status is critical (failure). nonRecoverable(6) The object’s status is nonrecoverable (dead). Table 2072. Dell Status Redundancy Variable Name: DellStatusRedundancy Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s redundancy status is unknown. full(3) The object is fully redundant.
The DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent back by this subagent has the most significant byte of the information as the first byte. For example, the hex address 0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ... Byte 1 Byte 2 Byte 3 Byte 4. Full Dates Variable Name: DellDateName Data Type: DisplayString DisplayString (SIZE (25)) Full dates are defined in the ASCII format: yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.
SNMP Sample Output 31 This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB).
'\02\02\02\02\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.25.1 = '\03\03\03\03\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.26.1 = '\02\02\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.28.1 = '\03\03\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.42.1 = 3 1.3.6.1.4.1.674.
1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.4.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.5.1.1 cleared' 1.3.6.1.4.1.674.10892.1.300.40.1.6.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.7.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.8.1.1 '20050513100047.