Reference Guide
Required Command Levels (1, 2, 3) 
and name=value pair
Optional name=value pairs Use
NOTE: For SCSI controllers, the 
ID specified in 
enclosure=<ENCLOSUREID> is 
the connector number and for 
Serial Attached SCSI (SAS) 
controllers, ID is the 
connectorNumber:EnclosureInde
x.
controller=id 
enclosure=<ENCLOSUREID> info=fans 
index=n where id is the controller 
number and ENCLOSUREID is the 
enclosure number and n is the number 
of a fan. For example: controller=0 
enclosure=2 info=fans index=1
Displays the specified fan.
Omreport Power Supply Status
The following table describes the syntax for the omreport Power Supply commands
Table 73. Omreport Power Supply Commands
Required Command Levels (1, 2, 3) and 
name=value pair
Optional name=value pairs Use
omreport storage enclosure Displays property information for all 
enclosures attached to the system.
controller=id 
enclosure=<ENCLOSUREID> 
info=pwrsupplies where id is the 
controller number and ENCLOSUREID 
is the enclosure number. For example: 
controller=0 enclosure=2
Displays the power supplies for the 
specified enclosure.
controller=id 
enclosure=<ENCLOSUREID> 
info=pwrsupplies index=n where id is 
the controller number and 
ENCLOSUREID is the enclosure 
number and n is the number of a 
power supply. For example: 
controller=0 enclosure=2 
info=pwrsupplies index=1
Displays the specified power supply.
Omreport EMM Status
The following table describes the syntax for the omreport EMM commands
NOTE: The status of the EMMs is displayed as degraded if there is a mismatch between the EMM firmware.
127