Reference Guide

Chassis Asset Tag : c
Omreport Chassis Intrusion
Use the omreport chassis intrusion command to find out whether the cover of the system is open or not. Server
Administrator tracks chassis intrusion events because intrusions may indicate an attempt to steal a system component,
or to perform unauthorized maintenance on the system. Type:
omreport chassis intrusion
A message that resembles the following is displayed:
Intrusion Information
Health : Ok
Index : 0
Status : OK
Probe Name : Intrusion
State : Chassis is closed
Omreport Chassis Leds Or Omreport Mainsystem Leds
Use the omreport chassis leds or omreport mainsystem leds command to find out whether clear hard drive fault is
supported and what severity level lights up the LED. Type:
omreport chassis leds index=n
or
omreport mainsystem leds index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays a summary of LED
information for chassis 0. If you specify the index, Server Administrator displays a summary for a specific chassis.
The following is an example output:
Main System Chassis
Flash chassis identify LED state : Off
Flash chassis identify LED timeout value : 300
Omreport Chassis Memory Or Omreport Mainsystem Memory
Use the omreport chassis memory or omreport mainsystem memory to view details for each memory module slot in the
system. If the system supports redundant memory, this command also displays the status, state, and type of memory
redundancy implemented on the system. Type:
omreport chassis memory index=n
or
omreport mainsystem index=n
The index parameter is optional. If you do not specify the index, Server Administrator displays information for all
memory modules on the system as follows:
The following is an example output:
30