Dell OpenManage SNMP Reference Guide Version 7.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. © 2013 Dell Inc.
Contents 1 Introduction................................................................................................................................11 What’s New in This Release...................................................................................................................................11 Supported SNMP Versions.....................................................................................................................................
5 Chassis Information Group...................................................................................................... 45 Chassis Information Group Tables..........................................................................................................................45 Chassis Information Table................................................................................................................................45 UUID Table........................................................
Cooling Device Table......................................................................................................................................141 Temperature Probe Table.............................................................................................................................. 145 Thermal Group Variable Values............................................................................................................................149 10 User Security Group....................
14 Slot Group...............................................................................................................................253 System Slot Group Table...................................................................................................................................... 253 System Slot Variable Values.................................................................................................................................256 15 Memory Group..............................
COO Options Table......................................................................................................................................... 339 COO Maintenance Table................................................................................................................................ 340 COO Repair Table........................................................................................................................................... 342 COO Support Information Table..........
Power Supply Connection Table.................................................................................................................... 444 Temperature Probe Table.............................................................................................................................. 446 Temperature Probe Connection Table........................................................................................................... 449 Enclosure Management Module Table.............................
RAC Traps............................................................................................................................................................. 518 PowerEdge M1000e CMC Traps........................................................................................................................... 519 PowerEdge VRTX CMC Traps............................................................................................................................... 519 System Trap Group..............
Common Data Types.............................................................................................................................................561 Variables with Data Types of State Capabilities and State Capabilities Unique..................................................561 Dell Status Data Types..........................................................................................................................................562 Dell Date..............................................
Introduction 1 This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage Version 7. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms. This introduction is divided into two sections. The first section, Introduction to the SNMP Reference Guide, explains the SNMP Reference Guide design.
Supported SNMP Versions Operating System Supported OMSA SNMP version Windows SNMP v1 Linux SNMP v1 Introduction to the SNMP Reference Guide This reference guide provides a formatted version of the following Management Information Base that are released with the current version of Dell OpenManage. Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to define MIB objects.
Section Topics MIB Group Numbers 6 Operating System Group — defines variables for name, version, service pack, and other information about a system’s operating system 400 7 System Resource Group — defines variables for input/output ports, memory, interrupts, and direct memory access 500 8 Power Group — defines variables for power units, power supplies, 600 and their current and voltage probes 9 Thermal Group — defines variables for temperature probes and cooling devices 700 10 User Security G
The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or MIB tables that provide related information. Table below describes each Server Administrator Remote Access MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator Remote Access MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1. where is the MIB group number assigned to the MIB group.
Table 4.
Section Topics • • • • MIB Group Number CMC Power Information CMC PSU Information Chassis Alerts Legacy Alerting How This Guide Defines Technical Terms The following table provides information about where to find definitions for technical terms in this reference guide. Table 7. Where to Find Definitions for Technical Terms Type of Definition See Basic SNMP vocabulary. Introduction MIB-group-specific variable values.
Tables This reference guide contains two types of tables: tables that are used to organize and define variable values and tables that define MIB objects. Readers must understand the difference between these two types of tables. SNMP Tables Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables organize data into two-dimensional structural arrays. In SNMP, objects that have a relationship to other objects are called columnar objects.
Access Read-only Table 11. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only Table 12. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 13. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
– USB Control Table – IDE Control Table – Diskette Control Table – Network Interface Control Table 3. Variables that make up each table in the group — This section documents the variables for the eight tables that comprise the BIOS group. 4. BIOS Variable Values — This section explains any Server Administrator-specific variables and data types that are used in this section. In the BIOS group example, there are 17 unique, Server Administrator-specific variable meanings.
All SNMP systems consist of one or more managed systems that provide data through an SNMP agent to a management system. The management system provides a user interface to view data from the managed systems. The management system and managed systems communicate over a network (typically through User Datagram Protocol/Internet Protocol [UDP/IP]). The management system and a managed system communicate by means of a common data schema. SNMP MIB files define the structure, type, and values of the SNMP data.
ENTERPRISES( 1) DELL (674) SNMPv2(6) In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674. The numbers in boldface type show the categories and numbers that apply to Server Administrator. All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values. SNMP Security SNMP version 1 has a very limited security mechanism.
Two drawbacks to SNMP traps are that they are sent using UDP, which is not a guaranteed delivery mechanism, and that they are not acknowledged by the receiver. An SNMP trap message contains the trap’s enterprise OID, the agent IP address, a generic trap ID, the specific trap ID, a time stamp, and zero or more variable bindings (varbinds). The combination of an enterprise OID and a specific trap ID uniquely identifies each Server Administrator-defined trap.
Instrumentation MIB Version Group 2 The Instrumentation Management Information Base (MIB) Version Group defines the attributes that identify the version of the Instrumentation MIB supported by the systems management software. The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not placed in a table.
Syntax DellUnsigned8BitRange Access Read-only 24
Systems Management Software Group 3 The Systems Management Software Group allows users to see information about the standards and software that are supported by the agent of a particular managed computer chassis. The Systems Management Software Group classifies each computer chassis according to the systems management standard that the agent supports.
Table 17. Systems Management Software Build Number Name systemManagementSoftwareBuildNumber Object ID 1.3.6.1.4.1.674.10892.1.100.3 Description Defines the build number of the systems management software. Syntax DellUnsigned16BitRange Access Read-only Table 18. Systems Management Software Description Name Name systemManagementSoftwareDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.100.4 Description Defines the description of the systems management software.
Table 22. Systems Management Software URL Name Name systemManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10892.1.100.8 Description Defines the universal resource locator (URL) of the systems management software. Syntax DisplayString (SIZE (0..1024)) Access Read-only Table 23. Systems Management Software Language Name Name systemManagementSoftwareLanguageName Object ID 1.3.6.1.4.1.674.10892.1.100.9 Description Defines the language of the systems management software.
Table 27. Systems Management Software Manufacturer Name Name systemManagementSoftwareManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.100.13 Description Defines the manufacturer of the systems management software. Syntax DellString Access Read-only Systems Management Software Variable Values This section includes definitions of server administrator-specific variable values used in this section. Table 28.
System State Group 4 The Management Information Base (MIB) variables presented in this section enable you to track various attributes that describe the state of the critical components supported by your system. Components monitored under the System State Group include power supplies, AC power cords, AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes. System State Group Table The System State Group defines objects in the System State MIB table.
• systemStatePowerUnitStatusCombined • systemStateCoolingUnitStatusCombined • systemStateACPowerSwitchStatusCombined • systemStateRedundantMemoryUnitStatusCombined • systemStateProcessorDeviceStatusCombined • systemStateBatteryStatusCombined • systemStateSDCardUnitStatusCombined • systemStateSDCardDeviceStatusCombined List 2 Variables that provide health status of each component in associated subsystem in chassis: • systemStatePowerSupplyStatusDetails • systemStateVoltageStatusDetails •
Table 32. System State Table Entry Name systemStateTableEntry Object ID 1.3.6.1.4.1.674.10892.1.200.10.1 Description Defines the System State Table entry. Syntax SystemStateTableEntry Access Not accessible Index systemStatechassisIndex Table 33. System State Chassis Index Name systemStatechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 34.
Access Read-only Table 37. System State Power Unit State Details Name systemStatePowerUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.5 Description Defines the state of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific power unit. The first byte returned represents the state of the first power unit, the second byte returned represents the state of the second power unit, and so on.
Syntax Octet String (Size (1..128)) Access Read-only Table 41. System State Power Supply Status Combined Name systemStatePowerSupplyStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.9 Description Defines the status of all power supplies in this chassis. Syntax DellStatus Access Read-only Table 42. System State Power Supply Status Details Name systemStatePowerSupplyStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 45. System State Voltage Status Details Name systemStateVoltageStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.13 Description Defines the status of all voltage probes in this chassis. Syntax Octet String (Size (1..128)) Access Read-only Table 46. System State Amperage State Details Name systemStateAmperageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.14 Description Defines the state of all current probes in this chassis.
Table 49. System State Cooling Unit State Details Name statesystemStateCoolingUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit. The first byte returned represents the state of the first cooling unit, the second byte returned represents the state of the second cooling unit, and so on.
Access Read-only Table 53. System State Cooling Device Status Combined Name systemStateCoolingDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.21 Description This attribute defines the cooling device status of all cooling devices in this chassis. The results is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only Table 54.
Syntax DellStatus Access Read-only Table 57. System State Temperature Status Details Name systemStateTemperatureStatusDetailsly Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.25 Description Defines the status of all temperature probes in this chassis. The first byte returned represents the status of the first temperature probe, the second byte returned represents the status of the second temperature probe, and so on. Syntax Octet String (Size(1..128) Access Read-on Table 58.
Syntax Octet String (Size(1..128) Access Read-only Table 61. System State Chassis Intrusion State Details Name systemStateChassisIntrusionStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.29 Description Defines the intrusion state of all intrusion detection devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific intrusion detection device.
Description Defines the individual state of all AC power switches in this chassis. The first byte returned represents the state of the first AC power switch, the second byte returned represents the state of the second AC power switch, and so on. Syntax Octet String (Size(1..128)) Access Read-only Table 65. System State AC Power Switch Status Redundancy Name systemStateACPowerSwitchStatusRedundancy Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Access Read-only Table 69. System State AC Power Cord Status Details Name systemStateACPowerCordStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.37 Description Defines the individual status of all AC power cords for any AC power switches in this chassis. The first byte returned represents the status of the first AC power cord, the second byte returned represents the status of the second AC power cord, and so on. Syntax Octet String (SIZE(1..128)) Access Read-only Table 70.
Access Read-only Table 73. System State Event Log Status Name systemStateEventLogStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41 Description Defines the overall status of this chassis (ESM) event log. Syntax DellStatus Access Read-only Table 74. System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42 Description Defines the combined status of all power units of this chassis.
Description Lists the status of each cooling unit of this chassis. The results are returned as a binary octet string where each byte of the octet string represents the status of a cooling unit. The first byte returned represents the status of the first cooling unit, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String (Size(1..128)) Access Read-only Table 78. System State AC Power Switch Status Combined Name systemStateACPowerSwitchStatusCombined Object ID 1.3.6.1.
Syntax Octet String (Size(1..128)) Access Read-only Table 82. System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50 Description Defines the combined status of all processor devices of this chassis. Syntax DellStatus Access Read-only Table 83. System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 86. System State SD Card Unit Status Combined Name systemStateSDCardUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.54 Description Defines the combined status of all SD Card units of this chassis. Syntax DellStatus Access Read-only Table 87. System State SD Card Unit Status List Name systemStateSDCardUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.55 Description Lists the status of each SD Card unit of this chassis.
Chassis Information Group 5 The Chassis Information Group objects provide information about the modular chassis in which a blade system resides. NOTE: This Chassis information is only available for modular/blade systems. For Rack and Tower systems, the information is empty. Currently there is just one object under the Chassis Information Group. Table 90. Chassis Service Tag Name chassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.1.2.1.0 This attribute defines the service tag of the enclosing chassis.
Chassis Information Table Entry Name chassisInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.10.1 Description Defines the chassis information table entry. Syntax ChassisInformationTableEntry Access Not accessible Index chassisIndexChassisInformation Chassis Index Chassis Information Name chassisIndexChassisInformation Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.1 Description Defines the index (one-based) of this chassis. The first chassis is numbered one.
Chassis Parent Index Reference Name chassisparentIndexReference Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.4 Description Defines the index (one-based) of the parent chassis of this chassis, if any. A zero (0) means that this chassis is the parent of all other chassis managed by the Server Administrator. Syntax DellObjectRange Access Read-only Chassis Type Name chassisType Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.6 Description Defines the chassis type.
Chassis Asset Tag Name Name chassisAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.10 Description Defines the user-assigned asset tag name for this chassis. Syntax DisplayString (SIZE (0..10)) Access Read-write Chassis Service Tag Name Name chassisServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.11 Description Defines the service tag name for this chassis. Syntax DisplayString (SIZE (0..7)) Access Read-only Chassis ID Name chassisID Object ID 1.3.6.1.4.1.674.10892.1.
Chassis System Name Name chassisSystemName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.15 Description Defines the system name of this chassis. Syntax DellString Access Read-only Chassis System Boot Date Name Name chassisSystemBootDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.16 Description Defines the boot time of this system. Syntax DellDateName Access Read-only Chassis System Date Name Name chassisSystemDateName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis System User Phone Number Name Name chassisSystemUserPhoneNumberName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.20 Description Defines the user-assigned phone number of the primary user of the system. Syntax DellString Access Read-write Chassis Connection Status Unique Name chassisConnectionStatusUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.21 Description Defines the status of the connection from the system chassis to an expansion chassis.
Chassis LED Control Settings Unique Name chassisLEDControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25 Description Defines the readings and settings of the LED control hardware in the chassis. Syntax DellLEDControlSettings (See Front-Panel LED Control Settings) Access Read-write Chassis Hard-Drive (HD) Fault Clear Control Capabilities Name chassisHDFaultClearControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Chassis Lock Present Name chassisLockPresent Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.30 Description Specifies whether a chassis lock is present on the chassis. Syntax DellBoolean Access Read-only Chassis Host Control Capabilities Unique Name chassishostControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.31 Description Defines the capabilities of the host control object.
Chassis Watchdog Control Expiry Time Capabilities Unique Name chassiswatchDogControlExpiryTimeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.35 Description Defines the capabilities of the watchdog expiry timer object. Syntax DellWatchDogTimerCapabilities (See Watchdog Timer Capabilities) Access Read-only Chassis Watchdog Control Expiry Time Name chassiswatchDogControlExpiryTime Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Syntax DellPowerButtonControlSettings (See Power Button Control Settings) Access Read-write Chassis Reseller Name Name chassisResellerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.40 Description Defines the name of the chassis reseller. Syntax DisplayString (SIZE (0..128)) Access Read-only Chassis Reseller Contact Information Name Name chassisResellerContactInformationName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.41 Description Defines the chassis reseller contact information name.
Access Read-only Chassis NMI Button Control Settings Unique Name chassisNMIButtonControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.45 Description Defines the current reading and allows setting of the NMI button control hardware. Syntax DellNMIButtonControlSettings (See NMI Button Control Settings) Access Read-write Chassis System Properties Name chassisSystemProperties Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.46 Description Defines the properties of the system.
Access Read-only UUID Table These objects comprise the server administrator definitions for the Universal Unique Identifier (UUID). Table 92. UUID Table Name uUIDTable Object ID 1.3.6.1.4.1.674.10892.1.300.20 Description Defines the UUID table. Syntax SEQUENCE OF UUIDTableEntry Access Not accessible Table 93. UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry.
Table 96. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.3 Description Defines the type of the UUID for this chassis. Syntax DellUUIDType Access Read-only Table 97. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE(16)) Access Read-only POST Log Table This section defines attributes for the power-on self-test (POST) log.
Table 100. POST Log Chassis Index Name postLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 101. POST Log Record Index Name postLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.2 Description Defines the record number (one-based) of the POST log. Syntax DellUnsigned32BitRange Access Read-only Table 102.
Table 105. POST Log Format Name postLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines format of the POST log. Syntax DellLogFormat (See Log Format) Access Read-only Event Log Table Table 106. Event Log Table Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.40 Description Defines the Event Log Table. Syntax SEQUENCE OF EventLogTableEntry Access Not accessible Table 107. Event Log Table Entry Name eventLogTableEntry Object ID 1.3.6.1.4.1.674.
Description Defines the record index of the event log. Syntax DellUnsigned32BitRange Access Read-only Table 110. Event Log State Capabilities Unique Name eventLogStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.3 Description Defines the capabilities of the object that is writing the event log. Syntax DellStateCapabilitiesLogUnique Access Read-only Table 111. Event Log State Settings Unique Name eventLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.
Description Defines the severity of the event log record. Syntax DellStatus Access Read-only Status Mandatory Table 115. Event Log Date Name Name eventLogDateName Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.8 Description Defines the date and time of the event log record. Syntax DellDateName Access Read-only Status Mandatory System BIOS Table This table lists objects that define the system’s basic input/output system (BIOS). Table 116.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 119. System BIOS Index Name systemBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.2 Description Defines the index (one-based) of the system BIOS of this object. Syntax DellObjectRange Access Read-only Table 120. System BIOS State Capabilities Name systemBIOSStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.
Description Defines the image size of the system BIOS in kilobytes (KB). A zero (0) indicates that the image size of the BIOS is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 124. System BIOS Release Date Name Name systemBIOSReleaseDateName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.7 Description Defines the release date of the system BIOS. Syntax DellDateName Access Read-only Table 125. System BIOS Version Name Name systemBIOSVersionName Object ID 1.3.6.1.4.1.674.10892.
Table 128. System BIOS Manufacturer Name Name systemBIOSManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.11 Description Defines the system BIOS manufacturer’s name. Syntax DellString Access Read-only Table 129. System BIOS Characteristics Name systemBIOSCharacteristics Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.12 Description Defines characteristics of the system BIOS. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Syntax Bit 19 EDD (Enhanced Disk Drive) Specification is supported Bit 20 Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in, 1k Bytes/Sector, 360 RPM) is supported Bit 21 Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in, 360 RPM) is supported Bit 22 Int 13h - 5.25 in / 360 KB Floppy Services are supported Bit 23 Int 13h - 5.25 in /1.2MB Floppy Services are supported Bit 24 Int 13h - 3.5 in / 720 KB Floppy Services are supported Bit 25 Int 13h - 3.5 in / 2.
Bit 1 USB Legacy is supported Bit 2 AGP is supported Bit 3 I2O boot is supported Bit 4 LS-120 boot is supported Bit 5 ATAPI ZIP Drive boot is supported Bit 6 1394 boot is supported Bit 7 Smart Battery supported Syntax DellUnsigned8BitRange Access Read-only Table 131. System BIOS Characteristics Ext 2 Name systemBIOSCharacteristicsExt2 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.14 Description Defines additional characteristics of the system BIOS.
Description Defines the Firmware Table entry Syntax FirmwareTableEntry Access Not accessible Index firmwarechassisIndex , firmwareIndex Table 134. Firmware Chassis Index Name firmwarechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 135. Firmware Index Name firmwareIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
Description Defines the status of the firmware. Syntax DellStateSettings Access Read-only Table 139. Firmware Size Name firmwareSize Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.6 Description Defines the image size of the firmware in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned16BitRange Access Read-only Table 140. Firmware Type Name firmwareType Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7 Description Defines the type of the firmware.
Access Read-only Table 144. Firmware Version Name Name firmwareVersionName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.11 Description Defines the version name of the firmware. Syntax DellString Access Read-only Intrusion Table The following objects and attributes describe the different forms of chassis intrusion, a situation that occurs when the cover of a computer is removed. Table 145. Intrusion Table Name intrusionTable Object ID 1.3.6.1.4.1.674.10892.1.300.
Table 148. Intrusion Index Name intrusionIndex Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.2 Description Defines the index of the intrusion objects in this subgroup. Syntax DellObjectRange Access Read-only Table 149. Intrusion State Capabilities Name intrusionStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.3 Description Defines the capabilities of the intrusion object. Syntax DellStateCapabilities Access Read-only Table 150.
Description Defines the type of the intrusion object. Syntax DellIntrusionType Access Read-only Table 154. Intrusion Location Name Name intrusionLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.8 Description Defines the location name of the intrusion object in this subgroup. Syntax DellString Access Read-only Baseboard Table This table lists objects that define the baseboard of a system. Table 155. Baseboard Table Name baseBoardTable Object ID 1.3.6.1.4.1.674.10892.1.300.
Table 158. Baseboard Index Name baseBoardIndex Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.2 Description Defines the index (one-based) of the base board. Syntax DellObjectRange Access Read-only Table 159. Baseboard State Capabilities Name baseBoardStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.3 Description Defines the state capabilities of the baseboard. Syntax DellStateCapabilities Access Read-only Table 160.
Description Defines the type of the baseboard. Syntax DellBaseBoardType Access Read-only Table 164. Baseboard Type Name Name baseBoardTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.8 Description Defines the name of the type of baseboard. Syntax DellString Access Read-only Table 165. Baseboard Location Name Name baseBoardLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.9 Description Defines the location name of the baseboard.
Table 169. Baseboard Service Tag Name Name baseBoardServiceTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.13 Description Defines the baseboard service tag name. Syntax DellString Access Read-only Table 170. Baseboard Piece Part ID (PPID) Name Name baseBoardPiecePartIDName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.14 Description Defines the baseboard PPID. Syntax DellString Access Read-only Table 171. Baseboard Asset Tag Name Name baseBoardAssetTagName Object ID 1.3.6.1.4.1.
Table 174. Chassis Type Variable Name : DellChassisType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The chassis type is not one of the following: unknown(2) The chassis type is unknown. desktop(3) The chassis type is a desktop. lowProfileDeskto p(4) The chassis type is a low-profile desktop. pizzaBox(5) The chassis type is a pizza box. miniTower(6) The chassis type is a minitower. tower(7) The chassis type is a tower. portable(8) The chassis type is a portable.
Possible Data Values Meaning of Data Value unknown(2) The status of the chassis connection is unknown. ok(3) The status of the chassis connection is OK. failure(4) The status of the chassis connection is failure. Table 176. Fan Control Capabilities Variable Name : DellFanControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The fan’s capabilities are unknown. lowSpeedCapable( 2) The fan can be set to low speed.
Possible Data Values Meaning of Data Value none(0) The hard drive has no fault LED capabilities. unknownCapabilit The hard-drive fault LED capabilities are unknown. ies(1) enableCapable(2) The hard-drive fault LED can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable( The hard-drive fault LED can indicate not ready. 4) resetCapable(8) The hard-drive fault LED can be reset. Table 180.
NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning components. When enabled, the blinking lights help administrators locate the problem chassis. Table 182. Chassis Identification Control Settings Variable Name : DellChassisIdentifyControlSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The chassis identification control’s state is unknown..
manualRebootWith The operator can reboot without operating system outOSShut shutdown. downCapable(32) manualPowerOffWi The operator can power off with operating system thOSShutd shutdown. ownCapable(64) manualPowerOffWi The operator can power off without operating thoutOSSh system shutdown. utdownCapable(12 8) manualPowerCycle The operator can power cycle with operating WithOSShu system shutdown. tdownCapable(256 ) manualPowerCycle The operator can power cycle without operating WithoutOS system shutdown.
automaticNotific Watchdog controls can be set to notify capable ationCapable(4) host automaticWatchDo Watchdog controls can be set to function gTimerCapable(8) automatically. automaticPowerOf Watchdog controls can be set to automatically fCapable(16) power off host. automaticAllExce Watchdog controls can be set to automatically ptNotificationCa perform all functions except notification capable. p able(27) automaticFullyCa Watchdog controls can be set to automatically pable(31) perform all functions.
enableCapable(2) The power button can be enabled (online) or disabled (offline). Table 189. Power Button Control Settings Variable Name : DellPowerButtonControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The power button has no settings capabilities. unknown(1) The power button settings are unknown. enabled(2) The power button state is enabled. disabled(4) The power button state is disabled. Table 190.
Table 193. Baseboard Type Variable Name : DellBaseBoardType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The baseboard type is unknown. other(2) The baseboard type is not one of the following types. serverBlade(3) The baseboard type is a server blade. connectivitySwit The baseboard type is a connectivity switch. ch(4) systemManagement The baseboard type is a system management Module(5) module. processorModule( The baseboard type is a processor module.
Data Type: Integer Possible Data Values Meaning of Data Value other(1) The firmware type is other than following values. unknown(2) The firmware type is unknown. systemBIOS(3) The firmware type is System BIOS embeddedSystemMa The firmware type is Embedded System nagementContro Management Controller. ller(4) powerSupplyParal The firmware type is Power Supply Paralleling lelingBoard(5) Board. systemBackPlane( The firmware type is System (Primary) Backplane.
boardIsHostingBo This baseboard is a hosting board. ard(1) boardRequiresDau This baseboard requires at least one daughter ghterBoard (2) board or auxiliary card. boardIsRemovabl e(4) This baseboard is removable. boardIsReplaceab This baseboard is replaceable. le(8) boardIsHotSwappa This baseboard is hot swappable.
Operating System Group 6 The Operating System Group provides status and identifying information about a system’s operating system. Identifying information includes the name, version, and service pack of the installed operating system. The following objects describe the fields for Operating System Group. Operating System Memory Table Table 197. Operating System Memory Table Name operatingSystemMemoryTable Object ID 1.3.6.1.4.1.674.10892.1.400.20 Description Defines the Operating System Memory Table.
Access Read-only Table 201. Operating System Memory State Settings Name operatingSystemMemoryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.3 Description Defines the state and allows the setting of the operating system memory. Syntax DellStateSettings Access Read-write Table 202. Operating System Memory Status Name operatingSystemMemoryStatus Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.4 Description Defines the status of the operating system memory.
Table 206. Operating System Memory Available Page File Size Name operatingSystemMemoryAvailablePageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.8 Description Defines the available page file memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 207. Operating System Memory Total Virtual Size Name operatingSystemMemoryTotalVirtualSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.9 Description Defines the total virtual memory size in kilobytes.
System Resource Group 7 The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources. This section includes System Resource Group Tables that track variables such as the owner, ports, system memory, interrupts, and direct memory access.
Table 211. System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 212. System Resource Map Index Name systemResourceMapIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.2 Description Defines the index of system resource maps in this chassis. Syntax DellObjectRange Access Read-only Table 213.
Description Defines the type of this system map. Syntax DellSystemResourceMapType (System Resource Map Type) Access Read-only System Resource Owner Table Table 217. System Resource Owner Table Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20 Description Defines the System Resource Owner Table. Syntax SEQUENCE OF SystemResourceOwnerTableEntry Access Not accessible Table 218. System Resource Owner Table Entry Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.
Table 221. System Resource Owner State Capabilities Name systemResourceOwnerStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.3 Description Defines the capabilities of this system resource owner. Syntax DellStateCapabilities Access Read-only Table 222. System Resource Owner State Settings Name systemResourceOwnerStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4 Description Defines the state settings of this system resource owner.
Description Defines the description name of the system resource owner. Syntax DellString Access Read-only Table 227. System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.9 Description Defines the associated system resource owner interface instance in this chassis. Syntax DellObjectRange Access Read-only System Resource Input/Output (I/O) Port Table Table 228.
Table 231. System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2 Description Defines the index (one-based) of the system resource I/O ports in this chassis. Syntax DellObjectRange Access Read-only Table 232. System Resource I/O Port State Capabilities Name systemResourceIOPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.3 Description Defines the capabilities of the system resource I/O port.
Description Defines the share disposition of the system resource I/O port. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 237. System Resource I/O Port Starting Address Name systemResourceIOPortStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.8 Description Defines the 64 bits of the starting address of the system resource I/O port. Syntax DellUnsigned64BitRange Access Read-only Table 238.
Table 241. System Resource Memory Chassis Index Name systemResourceMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 242. System Resource Memory Index Name systemResourceMemoryIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2 Description Defines the index of system resource memory in this chassis. Syntax DellObjectRange Access Read-only Table 243.
Syntax DellObjectRange Access Read-only Table 246. System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.7 Description Defines the share disposition of the system resource memory. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 247. System Resource Memory Starting Address Name systemResourceMemoryStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.
Access Not accessible Table 251. System Resource Interrupt Table Entry Name systemResourceInterruptTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.50.1 Description Defines the System Resource Interrupt Table entry. Syntax SystemResourceInterruptTableEntry Access Not accessible Index systemResourceInterruptchassisIndex , systemResourceInterruptIndex Table 252. System Resource Interrupt Chassis Index Name systemResourceInterruptchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.
Access Read-write Table 256. System Resource Interrupt Status Name systemResourceInterruptStatus Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.5 Description Defines the status of this system resource interrupt. Syntax DellStatus Access Read-only Table 257. System Resource Interrupt Owner Index Reference Name systemResourceInterruptOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.6 Description Defines the index for the associated system resource owner in this chassis.
Table 261. System Resource Interrupt Trigger Name systemResourceInterruptTrigger Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10 Description Defines the interrupt trigger of the system resource interrupt. Syntax DellResourceInterruptTrigger (Resource Interrupt Trigger) Access Read-only System Resource Direct Memory Access (DMA) Table Table 262. System Resource Direct Memory Access (DMA) Table Name systemResourceDMATable Object ID 1.3.6.1.4.1.674.10892.1.500.
Access Read-only Table 266. System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA. Syntax DellStateCapabilities Access Read-only Table 267. System Resource DMA State Settings Name systemResourceDMAStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.4 Description Defines the state and setting of this system resource DMA.
Table 271. System Resource DMA Maximum Transfer Size Name systemResourceDMAMaximumTransferSize Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.8 Description Defines the maximum size of a memory transfer in bytes for the system resource DMA. Syntax DellUnsigned32BitRange Access Read-only Table 272. System Resource DMA Transfer Width Name systemResourceDMATransferWidth Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.9 Description Defines the transfer width of the system resource DMA.
typeIsUnknown(2) The interface type is unknown. typeIsInternal(3) The interface type is internal. typeIsISA(4) The interface type is an Industry Standard Architecture (ISA) bus. typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus. typeIsMCA(6) The interface type is a microchannel architecture (MCA) bus. typeIsTurboChannel(7) The interface type is a turbo-channel bus. Table 276.
interruptIsLatched(2) The interrupt type is latched. Table 279. Resource Interrupt Trigger Variable Name: DellResourceInterruptTrigger Data Type: Integer Possible Data Values Meaning of Data Value interruptIsActiveWhenL ow(1) The interrupt trigger is active on a low signal. interruptIsActiveWhenH igh(2) The interrupt trigger is active on a high signal. Table 280.
8 Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes. NOTE: Power Management features are only available for PowerEdge systems that have hot-swappable power supplies and not systems that have a fixed, nonredundant power supply installed.
Index powerUnitchassisIndex, powerUnitIndex Table 284. Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 285. Power Unit Index Name powerUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.2 Description Defines the index of the power unit in this chassis. Syntax DellObjectRange Access Read-only Table 286.
Table 289. Power Supply Count for Redundancy Name powerSupplyCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.6 Description Defines the total number of power supplies required for this power unit to have redundancy. Syntax DellString Access Read-only Table 290. Power Unit Name Name powerUnitName Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.7 Description Defines the name of the power unit in this chassis. Syntax DellString Access Read-only Table 291.
Table 294. Power Supply Chassis Index Name powerSupplychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 295. Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Table 296.
Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Table 300. Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerSupplyType (Power Supply Type Definitions) Access Read-only Table 301. Power Supply Location Name Name powerSupplyLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
Access Read-only Table 305. Power Supply Configuration Error Type Name powerSupplyConfigurationErrorType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.12 Description Defines the type of configuration error reported by the power supply sensor. Syntax DellPowerSupplyConfigurationErrorType (Power Supply Configuration Error Type) Access Read-only Table 306. Power Supply Power Monitor Capable Name powerSupplyPowerMonitorCapable Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.
Index voltageProbechassisIndex, voltageProbeIndex Table 310. Voltage Probe Chassis Index Name voltageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 311. Voltage Probe Index Name voltageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.2 Description Defines the index of voltage probes in this chassis. Syntax DellObjectRange Access Read-only Table 312.
Table 315. Voltage Probe Reading Name voltageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6 Description Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Table 316. Voltage Probe Type Name voltageProbeType Object ID 1.3.6.1.4.1.674.10892.1.
Table 320. Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.11 Description Defines the user-assigned value of the voltage probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 321. Voltage Probe Lower Noncritical Threshold Name voltageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. Syntax DellVoltageDiscreteReading Access Read-only Amerage Probe Table Table 326. Amerage Probe Table Name amperageProbeTable Object ID 1.3.6.1.4.1.
Access Read-only Table 330. Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.3 Description Defines the capabilities of the amperage probe. Syntax DellStateCapabilities Access Read-only Table 331. Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.4 Description Defines the state and settings of the amperage probe. Syntax DellStateSettings Access Read-write Table 332.
Access Read-only Table 334. Amperage Probe Type Name amperageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.7 Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Table 335. Amperage Probe Location Name Name amperageProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.8 Description Defines the location name of the amperage probe in this chassis. Syntax DellString Access Read-only Table 336.
Table 339. Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.12 Description Defines the user-assigned value of the amperage probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 340. Amperage Probe Lower Critical Threshold Name amperageProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
AC Power Switch Table Table 344. AC Power Switch Table Name aCPowerSwitchTable Object ID 1.3.6.1.4.1.674.10892.1.600.40 Description Defines the AC Power Switch Table. Syntax SEQUENCE OF ACPowerSwitchTableEntry Access Not accessible Table 345. AC Power Switch Table Entry Name aCPowerSwitchTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.40.1 Description Defines the AC Power Switch Table entry.
Syntax DellACPowerSwitchCapabilities Access Read-only Table 349. AC Power Switch Settings Name aCPowerSwitchSettings Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.4 Description Defines the settings of this AC power switch. Syntax DellACPowerSwitchSettings Access Read-write Table 350. AC Power Switch Redundancy Status Name aCPowerSwitchRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.5 Description Defines the redundancy status of this AC power switch.
Table 354. AC Power Switch Status Name aCPowerSwitchStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.9 Description Defines the status of this AC power switch. Syntax DellStatus Access Read-only AC Power Cord Table Table 355. AC Power Cord Table Name aCPowerCordTable Object ID 1.3.6.1.4.1.674.10892.1.600.42 Description Defines the AC Power Cord Table. Syntax SEQUENCE OF ACPowerCordTableEntry Access Not accessible Table 356.
Access Read-only Table 359. AC Power Cord State Capabilities Name aCPowerCordStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.3 Description Defines the capabilities of this AC power cord. Syntax DellACPowerCordStateCapabilities Access Read-only Table 360. AC Power Cord State Settings Name aCPowerCordStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.4 Description Defines the settings of this AC power cord.
Battery Table Table 364. Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Table 365. Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.1 Description Defines the Battery Table Entry. Syntax BatteryTableEntry Access Not accessible Index batteryChassisIndex , batteryIndex Table 366.
Table 369. Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-write Table 370. Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Description Defines the status of the battery. Syntax DellStatus Access Read-only Table 371. Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.
Table 374. Power Usage Table Entry Name powerUsageTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.60.1 Description Defines the Power Usage Table Entry. Syntax PowerUsageTableEntry Access Not accessible Index powerUsageChassisIndex , powerUsageIndex Table 375. Power Usage Chassis Index Name powerUsageChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 376.
Table 379. Power Usage Status Name powerUsageStatus Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.5 Description Defines the status of the power usage information. Syntax DellStatus Access Read-only Table 380. Power Usage Entity Name Name powerUsageEntityName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.6 Description Defines the name of the entity associated with this power usage information. Syntax DellString Access Read-only Table 381.
Table 384. Power Usage Peak Watts Start Date Name Name powerUsagePeakWattsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.10 Description Defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute. Syntax DellDateName Access Read-only Table 385. Power Usage Peak Watts Reading Date Name Name powerUsagePeakWattsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Table 389. Power Usage Idle Power Name powerUsageIdlePower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.15 Description Defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only Table 390. Power Usage Max Potential Power Name powerUsageMaxPotentialPower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.16 Description Defines the maximum potential power (in Watts) of the system.
Table 394. Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.20 Description Defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. Syntax DellUnsigned32BitRange Access Read-only Table 395. Power Usage Peak Headroom Name powerUsagePeakHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Access Read-only Table 399. Power Profile Index Name powerProfileIndex Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.2 Description Defines the index (one-based) of the power profile information. Syntax DellObjectRange Access Read-only Table 400. Power Profile Supported Profiles Name powerProfileSupportedProfiles Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.3 Description Defines the supported power profiles. Syntax DellPowerProfileType Access Read-only Table 401.
Table 404. Power Profile Custom Memory Management Capabilities Name powerProfileCustomMemoryManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.7 Description Defines the custom memory power and performance management capabilities that are available for the Custom power profile. Syntax DellMemoryPowerPerformanceManagementType Access Read-only Table 405. Power Profile Custom Memory Management Capabilities Name powerProfileCustomMemoryManagementSetting Object ID 1.3.6.1.4.1.674.
unknown(1) The power supply’s capabilities are unknown. onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The power supply’s capabilities are not ready. Table 409. Power Supply State Settings Unique Variable Name: DellPowerSupplyStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The power supply’s capabilities are unknown.
powerSupplyTypeIsLinear(3) The power supply type is a linear power supply. powerSupplyTypeIsSwitching(4) The power supply type is a switching power supply. powerSupplyTypeIsBattery(5) The power supply type is a battery. powerSupplyTypeIsUPS(6) The power supply type is an uninterruptable power supply. powerSupplyTypeIsConverter(7) The power supply type is a power converter power supply. powerSupplyTypeIsRegulator(8) The power supply type is a regulator power supply.
Table 413. Voltage Probe Type Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsOther(1) The voltage probe type is not one of the following: voltageProbeTypeIsUnknown(2) The voltage probe type is unknown (not known or not monitored). voltageProbeTypeIs1Point5Volt (3) The voltage probe type is a 1.5-volt (V) probe. voltageProbeTypeIs3Point3Volt (4) The voltage probe type is a 3.3-V probe.
amperageProbeTypeIsOther(1) The amperage probe type is not one of the following: amperageProbeTypeIsUnknown(2) The amperage probe type is unknown (not known or not monitored). amperageProbeTypeIs1Point5Volt(3) The amperage probe type is a 1.5-ampere (A) probe. amperageProbeTypeIs3Point3volt(4) The amperage probe type is a 3.3-A probe. amperageProbeTypeIs5Volt(5) The amperage probe type is a 5-A probe. amperageProbeTypeIsMinus5Volt(6) The amperage probe type is a –5-A probe.
Table 417. AC Power Switch Capabilities Variable Name: DellACPowerSwitchCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknownCapabilities(1) The AC power switch’s capabilities are unknown. inputSourceCord1NoReturnCapable(2) Input source is AC power cord 1, with no return. inputSourceCord1ReturnCapable(4) Input source is AC power cord 1, with return. inputSourceCord2NoReturnCapable(8) Input source is AC power cord 2, with no return.
onlineCapable(2) The AC power cord can be disabled (offline) or enabled (online). notReadyCapable(4) The AC power cord’s capabilities are not ready. Table 421. AC Power Cord State Settings Variable Name: DellACPowerCordStateSettings Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power cord’s state is unknown. online(2) The AC power cord’s state is disabled (offline) 0 or enabled (online) 1. notReady(4) The AC power cord’s state is not ready.
Table 424. Power Cap Setting Variable Name: DellPowerCapSetting Data Type: Integer Possible Data Values Meaning of Data Value disabled(0) Power cap is disabled. enabled(1) Power cap is enabled. Table 425. Power Profile Type Variable Name: DellPowerProfileType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Power profile type is Maximum Performance. osControl(2) Power profile type is OS control.
NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Memory power and performance management type is Maximum Performance. mhz1333(2) Memory power and performance is 1333 MHz. . mhz1067(4) Memory power and performance is 1067 MHz. mhz800(8) Memory power and performance is 800 MHz. minPower(16) Memory power and performance management type is Minimum Power. Table 428.
9 Thermal Group The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices and temperature probes.
Syntax TableEntry Access Read-only Table 432. Cooling Unit Index Name coolingUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.2 Description Defines the index (one-based) of cooling units. Syntax DellObjectRange Access Read-only Table 433. Cooling Unit State Capabilities Name coolingUnitStateCapabilties Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.3 Description Defines the capabilities of the cooling unit. Syntax DellStateCapabilities Access Read-only Table 434.
Table 437. Cooling Unit Name Name coolingUnitName Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.7 Description Defines the cooling unit name in this chassis. Syntax DellString Access Read-only Table 438. Cooling Unit Status Name coolingUnitStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.8 Description Defines the status of the cooling unit in this chassis. Syntax DellStatus Access Read-only Cooling Device Table Table 439. Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.
Access Read-only Table 442. Cooling Device Index Name coolingDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.2 Description Defines the index of cooling devices in this chassis. Syntax DellObjectRange Access Read-only Table 443. Cooling Device State Capabilities Name coolingDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.3 Description Defines the capabilities of the cooling device. Syntax DellStateCapabilities Access Read-only Table 444.
Access Read-only Table 447. Cooling Device Type Name coolingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.7 Description Defines the cooling device type. Syntax DellCoolingDeviceType (Cooling Device Type) Access Read-only Table 448. Cooling Device Location Name Name coolingDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.8 Description Defines the location of the cooling device in this chassis. Syntax DellString Access Read-only Table 449.
Table 452. Cooling Device Lower Noncritical Threshold Name coolingDeviceLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.12 Description Defines the user-assigned value of the fan’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 453. Cooling Device Lower Critical Threshold Name coolingDeviceLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.13 Description Defines the value of the fan’s lower critical threshold.
Description Defines the probe capabilities of the cooling device. Syntax DellProbeCapabilities Access Read-only Table 458. Cooling Device Discrete Reading Name coolingDeviceDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.18 Description Defines the reading for a voltage probe of type coolingDeviceSubTypeIsDiscrete. When the value for coolingDeviceSubType is other than coolingDeviceSubTypeIsDiscrete, a value is not returned for this attribute.
Access Read-only Table 462. Temperature Probe Index Name temperatureProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.2 Description Defines the index of temperature probes in this chassis. Syntax DellObjectRange Access Read-only Table 463. Temperature Probe State Capabilities Name temperatureProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.3 Description Defines the capabilities of the temperature probe. Syntax DellStateCapabilities Access Read-only Table 464.
Access Read-only Table 467. Temperature Probe Type Name temperatureProbeType Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.7 Description Defines the temperature probe type. Syntax DellTemperatureProbeType (Temperature Probe Type) Access Read-only Table 468. Temperature Probe Location Name Name temperatureProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.8 Description Defines the location of the temperature probe in this chassis. Syntax DellString Access Read-only Table 469.
Table 472. Temperature Probe Lower Noncritical Threshold Name temperatureProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.12 Description Defines the user-assigned value of the temperature probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-write Table 473. Temperature Probe Lower Critical Threshold Name temperatureProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Thermal Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 477. Cooling Device Type Variable Name: DellCoolingDeviceType Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceTypeIsOther(1) The cooling device type is not one of the following: coolingDeviceTypeIsUnknown(2) The cooling device type is unknown (not known or not monitored). coolingDeviceTypeIsAFan(3) The cooling device type is a fan.
Table 479. Cooling Device Discrete Reading Variable Name: DellCoolingDeviceDiscreteReading . Data Type: Integer Possible Data Values Meaning of Data Value coolingDeviceIsGood(1) The cooling device discrete reading is good. coolingDeviceIsBad(2) The cooling device discrete reading is bad Table 480.
User Security Group 10 The User Security Table defines the objects that allow administrators to create and modify user accounts and to control which users can perform Set operations on managed systems. User Security Group Table The User Security Group defines objects in the User Security MIB table. The following object sets up the User Security Table: Table 482. User Security Table Name userSecurityTable Object ID 1.3.6.1.4.1.674.10892.1.
Table 485. User Security Index Name userSecurityIndex Object ID 1.3.6.1.4.1.674.10892.1.800.1.2 Description Defines the user security index. Syntax DellObjectRange Access Read-only Table 486. User Security User Name Name userSecurityUserName Object ID 1.3.6.1.4.1.674.10892.1.800.1.3 Description Defines the user security user name. Syntax DellSecurityString Access Read-only Table 487. User Security Control Name Name userSecurityControlName Object ID 1.3.6.1.4.1.674.10892.1.800.1.
Remote Flash BIOS Group 11 The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates on the system. Remote Flash BIOS Group Table The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table. Remote Flash BIOS Table The following object sets up the Remote Flash BIOS Table: Table 489. Remote Flash BIOS Table Name remoteFlashBIOSTable Object ID 1.3.6.1.4.1.674.
Table 492. Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system. Syntax DellObjectRange Access Read-only Table 493. Remote Flash BIOS State Capabilities Unique Name remoteFlashBIOSStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.3 Description Defines the capabilities of the remote BIOS update hardware on this system.
Table 497. Remote Flash BIOS Completion Code Name remoteFlashBIOSCompletionCode Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.7 Description Defines the completion code of the last BIOS update. Syntax DellRemoteFlashBIOSCompletionCode (Remote Flash BIOS Completion Code) Access Read-only Table 498. Remote Flash BIOS Minimum Contiguous Memory Name remoteFlashBIOSMinimumContiguousMemory Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.
canceled(8) The remote flash BIOS has been canceled. pending(16) The remote flash BIOS update is pending. other(32) The remote flash BIOS state/setting is not one of the previous values. Table 501.
12 Port Group The Port Group provides information about the different types of ports that may be present in your system. This management information base (MIB) group also provides information about the capabilities, states, and settings that are possible for each port.
, pointingPortIndex Table 504. Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 505. Pointing Port Index Name pointingPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.2 Description Defines the index of the pointing ports in this chassis. Syntax DellObjectRange Access Read-only Table 506.
Access Read-only Table 509. Pointing Port Security State Name pointingPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.10.6 Description Defines the security settings of the pointing port. Syntax DellPortSecurityState Access Read-only Table 510. Pointing Port Connector Type Name pointingPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.10.7 Description Defines the connector type of the pointing port.
Syntax IntegerKeyboardPortTableEntry Access Not accessible Table 514. Keyboard Port Table Entry Name keyboardPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1 Description Defines the Keyboard Port Table entry. Syntax KeyboardPortTableEntry Access Not accessible Index keyboardPortchassisIndex , keyboardPortIndex Table 515. Keyboard Port Chassis Index Name keyboardPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.
Table 518. Keyboard Port State Settings Name keyboardPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.4 Description Defines the state and settings of the keyboard port. Syntax DellStateSettings Access Read-only Table 519. Keyboard Port Status Name keyboardPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.5 Description Defines the status of the keyboard port. Syntax DellStatus Access Read-only Table 520.
Table 523. Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Table 524. Processor Port Table Name processorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.30 Description Defines the Processor Port Table. Syntax IntegerProcessorPortTableEntry Access Not accessible Table 525.
Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Table 528. Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port. Syntax DellStateCapabilities Access Read-only Table 529. Processor Port State Settings Name processorPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.
Syntax DellProcessorPortConnectorType (See Processor Port Connector Types) Access Read-only Table 533. Processor Port Name Name processorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.8 Description Defines name of the processor port. Syntax DellString Access Read-only Table 534. Processor Port BIOS Connector Type Name processorPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.9 Description Defines the BIOS connector type of the processor port.
Table 537. Memory Device Port Chassis Index Name memoryDevicePortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 538. Memory Device Port Index Name memoryDevicePortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.2 Description Defines the index of the memory device port in this chassis. Syntax DellObjectRange Access Read-only Table 539.
Table 542. Memory Device Port Security State Name memoryDevicePortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.6 Description Defines the security settings of the memory device port. Syntax DellPortSecurityState Access Read-only Table 543. Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7 Description Defines the connector type of the memory device port.
Table 547. Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any). Syntax DellUnsigned32BitRange Access Read-only Monitor Port Table Table 548. Monitor Port Table Name monitorPortTable Object ID 1.3.
Table 551. Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Table 552. Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port. Syntax DellStateCapabilities Access Read-only Table 553.
Table 556. Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port. Syntax DellMonitorPortConnectorTypes (See Monitor Port Connector Types) Access Read-only Table 557. Monitor Port Name Name monitorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.8 Description Defines the name of the monitor port. Syntax DellString Access Read-only Table 558.
Index sCSIPortchassisIndex , sCSIPortIndex Table 561. SCSI Port Chassis Index Name sCSIPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.1 Description Defines the index (one-based) of this chassis Syntax DellObjectRange Access Read-only Table 562. SCSI Port Index Name sCSIPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.2 Description Defines the index of the SCSI ports in this chassis. Syntax DellObjectRange Access Read-only Table 563.
Syntax DellStatus Access Read-only Table 566. SCSI Port Security State Name sCSIPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.6 Description Defines the security settings of the SCSI port. Syntax DellPortSecurityState Access Read-only Table 567. SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7 Description Defines the connector type of the SCSI port.
Description Defines the Parallel Port Table. Syntax IntegerParallelPortTableEntry Access Not accessible Table 571. Parallel Port Table Entry Name parallelPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1 Description Defines the Parallel Port Table entry. Syntax ParallelPortTableEntry Access Not accessible Index parallelPortchassisIndex , parallelPortIndex Table 572. Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.
Table 575. Parallel Port State Settings Name parallelPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.4 Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-write Table 576. Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5 Description Defines the status of the parallel port. Syntax DellStatus Access Read-only Table 577.
Table 580. Parallel Port Connector Pin Out Name parallelPortConnectorPinOut Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.9 Description Defines the pinout of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Table 581. Parallel Port Capabilities Unique Name parallelPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.10 Description Defines the capabilities of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Table 582.
Serial Port Table Table 585. Serial Port Name serialPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.80 Description Defines the Serial Port Table. Syntax IntegerSerialPortTableEntry Access Not accessible Table 586. Serial Port Table Entry Name serialPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1 Description Defines the Serial Port Table entry. Syntax SerialPortTableEntry Access Not accessible Index serialPortchassisIndex , serialPortIndex Table 587.
Table 589. Serial Port State Capabilities Name serialPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.3 Description Defines the capabilities of the serial port. Syntax DellStateCapabilities Access Read-only Table 590. Serial Port State Settings Name serialPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.4 Description Defines the state and settings of the serial port. Syntax DellStateSettings Access Read-write Table 591.
Table 594. Serial Port Name Name serialPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.8 Description Defines the name of the serial port. Syntax DellString Access Read-only Table 595. Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description Defines the maximum speed the serial interface can support in bits per second (bps). Syntax DellUnsigned32BitRange Access Read-only Table 596.
Universal Serial Bus (USB) Port Table Table 599. Universal Serial Bus (USB) Port Name uSBPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.90 Description Defines the USB Port Table. Syntax IntegerUSBPortTableEntry Access Not accessible Table 600. USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry. Syntax USBPortTableEntry Access Not accessible Index uSBPortchassisIndex , uSBPortIndex Table 601.
Syntax DellStateCapabilities Access Read-only Table 604. USB Port State Settings Name uSBPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.4 Description Defines the state and settings of the USB port. Syntax DellStateSettings Access Read-write Table 605. USB Port Status Name uSBPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.5 Description Defines the state of the USB port. Syntax DellStatus Access Read-only Table 606.
Access Read-only Port Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 609. Pointing Port Connector Type Variable Name: DellPointingPortConnectorType Data Type :Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther( 1) The pointing port connector type is not one of the following: connectorPortTypeIsUnknow n(2) The pointing port connector type is unknown.
connectorPortTypeIsUnknown(2) The keyboard port connector type is unknown. connectorPortTypeIsMiniDIN(3) The keyboard port connector type is a mini DIN. connectorPortTypeIsMicroDIN(4) The keyboard port connector type is a MicroDIN. connectorPortTypeIsPS2(5) The keyboard port connector type is PS/2. connectorPortTypeIsInfrared(6) The keyboard port connector type is infrared. connectorPortTypeIsHPHIL(7) The keyboard port connector type is HP-HIL.
connectorPortTypeIsSIMM(3) The memory device port connector type is a single in-line memory module (SIMM). connectorPortTypeIsSIP(4) The memory device port connector type is a SIP. connectorPortTypeIsAChip(5) The memory device port connector type is a chip. connectorPortTypeIsDIP(6) The memory device port connector type is a dual in-line package (DIP). connectorPortTypeIsZIP(7) The memory device port connector type is a ZIP.
connectorPortTypeIsDIN68pin(5) The SCSI port connector type is a DIN 68-pin.
13 Device Group The Device Group defines information about the devices discovered on the system during an inventory scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID.
Syntax PointingDeviceTableEntry Access Not accessible Index pointingDevicechassisIndex , pointingDeviceIndex Table 617. Pointing Device Chassis Index Name pointingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 618. Pointing Device Index Name pointingDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.
Syntax DellStatus Access Read-only Table 622. Pointing Port Index Reference Name pointingPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.6 Description Defines the index to the pointing port in this chassis. Syntax DellObjectRange Access Read-only Table 623. Pointing Device Type Name pointingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.7 Description Defines the type of the pointing device.
Access Not accessible Index keyboardDevicechassisIndex , keyboardDeviceIndex Table 627. Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 628. Keyboard Device Index Name keyboardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2 Description Defines the index of the keyboard device for this chassis.
Access Read-only Table 632. Keyboard Port Index Reference Name keyboardPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.6 Description Defines the index to the associated the keyboard port in this chassis. Syntax DellStatus Access Read-only Table 633. Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.7 Description Defines the name of the keyboard type. Syntax DellString Access Read-only Table 634.
Index processorDevicechassisIndex , processorDeviceIndex Table 637. Processor Device Chassis Index Name processorDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 638. Processor Device Index Name processorDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.2 Description Defines the index of the processor device in this chassis.
Table 642. Processor Port Index Reference Name processorPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.6 Description Defines the index to the associated processor port in this chassis. Syntax DellObjectRange Access Read-only Table 643. Processor Device Type Name processorDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7 Description Defines the type of processor device. Syntax DellProcessorDeviceType (See Processor Device Type) Access Read-only Table 644.
Description Defines the maximum speed of the processor device in megahertz (MHz). A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 648. Processor Device Current Speed Name processorDeviceCurrentSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.12 Description Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 649.
Syntax DellString Access Read-only Table 653. Processor Device Core Count Name processorDeviceCoreCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.17 Description Defines the number of processor cores detected for the processor device. Syntax DellUnsigned32BitRange Access Read-only Table 654. Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
Access Read-only Table 657. Processor Device Extended Capabilities Name processorDeviceExtendedCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21 Description This attribute defines extended capabilities of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Table 660. Processor Device Model Name Name processorDeviceModelName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24 Description Defines the model of the processor device. Syntax DellString Access Read-only Table 661. Processor Device Stepping Name Name processorDeviceSteppingName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.25 Description Defines the stepping of the processor device. Syntax DellString Access Read-only Processor Device Status Table Table 662.
Access Read-only Table 665. Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe. Syntax DellObjectRange Access Read-only Table 666. Processor Device Status State Capabilities Name processorDeviceStatusStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3 Description Defines the state capabilities of the processor device status probe.
Table 670. Processor Device Status Location Name Name processorDeviceStatusLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.7 Description Defines the location name of the processor device status probe. Syntax DellString Access Read-only Table 671. Processor Device Status Port Index Reference Name processorDeviceStatusPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.8 Description Defines the index (one-based) of the associated processor port in the same chassis.
Syntax DellObjectRange Access Read-only Table 675. Cache Device Index Name cacheDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2 Description Defines the index of the cache device in this chassis. Syntax DellObjectRange Access Read-only Table 676. Cache Device State Capabilities Name cacheDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.3 Description Description Defines the capabilities of the cache device.
Table 680. Cache Device Type Name cacheDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.7 Description Defines the type of cache device. Syntax DellCacheDeviceType (See Cache Device Type) Access Read-only Table 681. Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Cache Device Location) Access Read-only Table 682.
Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 686. Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Defines the current size of the cache device in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 687.
Syntax DellCacheDeviceECCType (See Cache Device ECC Type) Access Read-only Table 691. Cache Device Associativity Name cacheDeviceAssociativity Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.18 Description Defines the type of associativity in use by the cache device. Syntax DellCacheDeviceAssociativity (See Cache Device Associativity) Access Read-only Table 692. Cache Device Supported Type Name cacheDeviceSupportedType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.
Syntax MemoryDeviceTableEntry Access Not accessible Index memoryDevicechassisIndex , memoryDeviceIndex Table 696. Memory Device Chassis Index Name memoryDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 697. Memory Device Index Name memoryDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.2 Description Defines the index of the memory device in this chassis.
Syntax DellStatus Access Read-only Table 701. Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-only Table 702. Memory Device Type Name memoryDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7 Description Defines the type of the memory device.
Description Defines the bank location name of the memory device. Syntax DellString Access Read-only Table 706. Memory Device Type Details Name memoryDeviceTypeDetails Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11 Description Defines the detailed type of the memory device. Syntax DellMemoryDeviceTypeDetails (See Memory Device Type Details) Access Read-only Table 707. Memory Device Form Factor Name memoryDeviceFormFactor Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.
Access Read-only Table 711. Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16 Description Defines the total number of bits, including ECC, used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Table 712. Memory Device Total Data Bus Width Name memoryDeviceTotalDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.17 Description Defines the total number of data bits used by the memory device.
Table 715. Memory Device Failure Modes Name memoryDeviceFailureModes Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20 Description Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK. It is a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks. Syntax DellMemoryDeviceFailureModes Access Read-only Table 716. Memory Device Manufacturer Name Name memoryDeviceManufacturerName Object ID 1.3.
Table 720. Memory Device Speed Name Name memoryDeviceSpeedName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25 Description This attribute defines the speed of the memory device in string format with units specified in string. Syntax DellString Access Read-only Table 721. Memory Device Rank Name memoryDeviceRank Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.26 Description 1100.0050.0001.0026 — This attribute defines the Rank of the memory device (DIMM). Zero indicates an unknown.
Index memoryDeviceMappedAddresschassisIndex , memoryDeviceMappedAddressIndex Table 724. Memory Device Mapped Address Chassis Index Name memoryDeviceMappedAddresschassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 725. Memory Device Mapped Address Index Name memoryDeviceMappedAddressIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Access Read-only Table 729. Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6 Description Defines the index of the memory device(s) associated with this memory device mapped address. Syntax DellObjectRange Access Read-only Table 730. Memory Device Mapped Address Row Position Name memoryDeviceMappedAddressRowPosition Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Access Read-only Table 734. Memory Device Mapped Address Ending Address Name memoryDeviceMappedAddressEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.11 Description Defines the physical ending address in KB of the memory device mapped address. Syntax DellUnsigned64BitRange Access Read-only Generic Device Table Table 735. Generic Device Table Name genericDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.70 Description Defines the Generic Device Table.
Description Defines the index of the generic device in this chassis. Syntax DellObjectRange Access Read-only Table 739. Generic Device State Capabilities Name genericDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.3 Description Defines the capabilities of the generic device. Syntax DellStateCapabilities Access Read-only Table 740. Generic Device State Settings Name genericDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.
Table 744. Generic Device Name Name genericDeviceName Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.8 Description Defines the name of the generic device. Syntax DellString Access Read-only PCI Device Table Table 745. PCI Device Table Name pCIDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.80 Description Defines the PCI Device Detail Table. Syntax SEQUENCE OF PCIDeviceTableEntry Access Not accessible Table 746. PCI Device Table Entry Name pCIDeviceTableEntry Object ID 1.3.6.1.4.1.
Access Read-only Table 749. PCI Device State Capabilities Name pCIDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.3 Description Defines the capabilities of the PCI device. Syntax DellStateCapabilities Access Read-only Table 750. PCI Device State Settings Name pCIDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.4 Description Defines the state of the PCI device. Syntax DellStateSettings Access Read-write Table 751.
Table 754. PCI Device Manufacturer Name Name pCIDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.8 Description Defines the name of the PCI device manufacturer. Syntax DellString Access Read-only Table 755. PCI Device Description Name Name pCIDeviceDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.9 Description Defines the descriptive name of the PCI device. Syntax DellString Access Read-only Table 756. PCI Device Speed Name pCIDeviceSpeed Object ID 1.3.
Table 759. PCI Device Configuration Space Table Entry Name pCIDeviceConfigurationSpaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1 Description Defines the PCI Device Configuration Table entry. Syntax PCIDeviceConfigurationSpaceTableEntry Access Not accessible Index pCIDeviceConfigurationSpacechassisIndex , pCIDeviceConfigurationSpaceIndex Table 760. PCI Device Configuration Space Chassis Index Name pCIDeviceConfigurationSpacechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.82.
Table 764. PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration. Syntax DellStatus Access Read-only Table 765. PCI Device Index Reference Name pCIDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.6 Description Defines the index number of PCI device that this configuration applies to. Syntax DellObjectRange Access Read-only Table 766.
Description Defines the common configuration space header of the PCI device. Syntax Octet String (SIZE(0.1025)) Access Read-only Network Device Table Table 770. Network Device Table Name networkDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.90 Description Defines the Network Device Table. Syntax SEQUENCE OF NetworkDeviceTableEntry Access Not accessible Table 771. Network Device Table Entry Name networkDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.90.
Table 774. Network Device Status Name networkDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.3 Description Defines the status of the network device. Syntax DellStatus Access Read-only Table 775. Network Device Connection Status Name networkDeviceConnectionStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.4 Description Defines the connection status of the network device. Syntax DellNetworkDeviceConnectionStatus (See Network Device Connection Status) Access Read-only Table 776.
Description Defines the service name of the network device. Syntax DellString Access Read-only Table 780. Network Device Driver Image Path Name Name networkDeviceDriverImagePathName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.9 Description Defines the path to the binary image of the driver for the network device. Syntax DellString Access Read-only Table 781. Network Device Driver Version Name Name networkDeviceDriverVersionName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Access Read-only Table 785. Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.14 Description Defines the IP address of the DHCP server that was used to obtain the IP address of the network device if DHCP was used to configure the network device. Syntax IpAddress Access Read-only Table 786. Network Device Current MAC Address Name networkDeviceCurrentMACAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Table 790. Network Device PCI Function Number Name networkDevicePCIFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19 Description Defines the PCI function number of the network device. Syntax DellUnsigned8BitRange Access Read-only Table 791. Network Device IRQ Name networkDeviceIRQ Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.20 Description Defines the interrupt request number of the network device. Syntax DellUnsigned32BitRange Access Read-only Table 792.
Description Defines if TOE is enabled for the network device. Syntax DellBoolean Access Read-only Table 796. Network Device RDMA Capability Flags Name networkDeviceRDMACapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25 Description Defines the Remote Direct Memory Access (RDMA) capability flags of the network device. Syntax DellNetworkDeviceRDMACapabilityFlags (See Network Device RDMA Capability Flags) Access Read-only Table 797.
Managed System Services Device Table Table 800. Managed System Services Device Table Name Object ID 1.3.6.1.4.1.674.10892.1.1100.100 Description Defines the Managed System Services Device Table. Syntax Sequence of ManagedSystemServicesDeviceTable Access Not accessible Table 801. Managed System Services Device Table Entry Name managedSystemServicesDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1 Description Defines the managed system services device table entry.
Syntax DellStatus Access Read-only Table 805. Managed System Services Device Type Name managedSystemServicesDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.4 Description Defines the type of the managed system services device. Syntax DellManagedSystemServicesDeviceType (See Managed System Services Device Type) Access Read-only Table 806. Managed System Services Device Storage Present Name managedSystemServicesDeviceStoragePresent Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.
Syntax SdCardUnitTableEntry Access Not accessible Index sdCardUnitChassisIndex , sdCardUnitIndex Table 810. SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card unit. Syntax DellObjectRange Access Read-only Table 811. SD Card Unit Index Name sdCardUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.
Syntax DellStatusRedundancy Access Read-only Table 815. SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.6 Description Defines the total number of SD Card devices required for this SD Card unit to have full redundancy. Syntax DellObjectRange Access Read-only Table 816. SD Card Unit Name Name sdCardUnitName Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.7 Description Defines the name of the SD Card unit.
Access Not accessible Index sdCardDeviceChassisIndex , sdCardDeviceIndex Table 820. SD Card Device Chassis Index Name sdCardDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card device. Syntax DellObjectRange Access Read-only Table 821. SD Card Device Index Name sdCardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.2 Description Defines the index (one-based) of the SD Card device.
Access Read-only Table 825. SD Card Device Config Settings Name sdCardDeviceConfigSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6 Description Defines the configuration settings of the SD Card device. Syntax DellSDCardDeviceConfigSettings Access Read-only Table 826. SD Card Device Location Name Name sdCardDeviceLocationName Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.7 Description Defines the location of the SD Card device. Syntax DellString Access Read-only Table 827.
Table 830. SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.11 Description Defines the index to the associated SD Card unit if the SD Card device is part of a SD Card unit. Syntax DellObjectRange Access Read-only Table 831. SD Card Device Card Available Storage Size Name sdCardDeviceCardAvailableStorageSize Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.
deviceTypeIsATouch Pad(7) Device type is a touch pad. Table 834. Processor Device Status State Variable Name:DellProcessorDeviceStatusState Data Type:Integer Possible Data Values Meaning of Data Value other(1) Processor device type is not one of the following: unknown(2) Device type is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device has its BIOS disabled. idle(6) Device is idle. Table 835.
deviceTypeIsMathP The processor device type is a math processor. rocessor(4) deviceTypeIsDSP(5 The processor device type is a digital signal ) processor. deviceTypeIsAVide The processor device is a video processor. oProcessor(6) Table 837. Processor Upgrade Information Variable Name:DellProcessorUpgradeInformation Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) The upgrade device type is not one of the following: processorUpgradeI Upgrade device type is unknown.
processorUpgradeI Upgrade is by Socket 939. sBySocket939(18) processorUpgradeI Upgrade is by Socket mPGA604. sBySocketmPGA604( 19) processorUpgradeI Upgrade is by Socket LGA771. sBySocketLGA771(2 0) processorUpgradeI Upgrade is by Socket LGA775. sBySocketLGA775(2 1) processorUpgradeI Upgrade is by Socket S1. sBySocketS1(22) processorUpgradeI Upgrade is by Socket AM2. sBySocketAM2(23) processorUpgradeI Upgrade is by Socket F (1207). sBySocketF(24) processorUpgradeI Upgrade is by Socket LGA1366.
deviceFamilyIsPen The processor family is Pentium Pro. tiumPro(12) deviceFamilyIsPen The processor family is Pentium II. tium2(13) deviceFamilyIsPen The processor family is Pentium MMX. tiumMMX(14) deviceFamilyIsCel The processor family is Celeron. eron(15) deviceFamilyIsXeo The processor family is Xeon. n(16) deviceFamilyIsPen The processor family is Pentium III. tium3(17) deviceFamilyIsPen The processor family is Pentium III Xeon.
deviceFamilyIsPow The processor family is Power PC 604. erPC604(36) deviceFamilyIsPow The processor family is Power PC 620. erPC620(37) deviceFamilyIsPow The processor family is Power PC x704. erPCx704(38) deviceFamilyIsPow The processor family is Power PC 750. erPC750(39) deviceFamilyIsInt The processor family is Intel Core Duo. elCoreDuo(40) deviceFamilyIsInt The processor family is Intel Core Duo mobile. elCoreDuoMobi le(41) deviceFamilyIsInt The processor family is Intel Core Solo mobile.
deviceFamilyIsAMD The processor family is AMD Opteron 6200 Series Opteron6200 (61) Processor. deviceFamilyIsAMD The processor family is AMD Opteron 4200 Series Opteron4200 (62) Processor. deviceFamilyIsMIP The processor family is MIPS S(64) deviceFamilyIsMIP The processor family is MIPS R4000. SR4000(65) deviceFamilyIsMIP The processor family is MIPS R4200. SR4200(66) deviceFamilyIsMIP The processor family is MIPS R4400. SR4400(67) deviceFamilyIsMIP The processor family is MIPS R4600.
deviceFamilyIsHob The processor family is Hobbit. bit(112) deviceFamilyIsCru The processor family is Crusoe 5000. soe5000(120) deviceFamilyIsCru The processor family is Crusoe 3000. soe3000(121) deviceFamilyIsEff The processor family is Efficeon 8000. iceon8000 (122) deviceFamilyIsWei The processor family is Weitek. tek(128) deviceFamilyIsInt The processor family is Intel Celeron M. elCeleronM(130) deviceFamilyIsAMD The processor family is AMD Athlon 64.
deviceFamilyIsPA- The processor family is PA-RISC 8500. RISC8500(145) deviceFamilyIsPA- The processor family is PA-RISC 8000. RISC8000(146) deviceFamilyIsPAR The processor family is PA-RISC 7300LC. ISC7300LC( 147) deviceFamilyIsPA- The processor family is PA-RISC 7200. RISC7200(148) deviceFamilyIsPAR The processor family is PA-RISC 7100LC. ISC7100LC( 149) deviceFamilyIsPA- The processor family is PA-RISC 7100. RISC7100(150) deviceFamilyIsV3 0(160) The processor family is V30.
deviceFamilyIsQua The processor family is Quad-Core Intel Xeon dCoreIntelXeon730 processor 7300 Series. 0(173) deviceFamilyIsQua The processor family is Quad-Core Intel Xeon dCoreIntelXeon740 processor 7400 Series. 0(174) deviceFamilyIsMul The processor family is Multi-Core Intel Xeon tiCoreIntelXeon74 processor 7400 Series. 00(175) deviceFamilyIsM1( The processor family is M1. 176) deviceFamilyIsM2( The processor family is M2.
deviceFamilyIsInt The processor family is Intel Core2 Duo mobile elCore2DuoMob processor. ile(196) deviceFamilyIsInt The processor family is Intel Core2 Solo mobile elCore2SoloMo processor. bile(197) deviceFamilyIsInt The processor family is Intel Core i7 processor. elCorei7(198) deviceFamilyIsDua The processor family is Dual-Core Intel Celeron lCoreIntelCel Processor. eron(199) deviceFamilyIsIBM The processor family is IBM390. 390(200) deviceFamilyIsG4( The processor family is G4.
deviceFamilyIsQua The processor family is Quad-Core Intel Xeon dCoreIntelXeo processor 5xxx Series. n5xxx(219) deviceFamilyIsDua The processor family is Dual-Core Intel Xeon lCoreIntelXeo processor 7xxx Series. n7xxx(221) deviceFamilyIsQua The processor family is Quad-Core Intel Xeon dCoreIntelXeo processor 7xxx Series. n7xxx(222) deviceFamilyIsMul The processor family is Multi-Core Intel Xeon tiCoreIntelXe processor 7xxx Series.
Table 839. Cache Device Type Variable Name:DellCacheDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) System cache type is not one of the following: deviceTypeIsUnkno System cache type is unknown. wn(2) deviceTypeIsInstr System cache type is instruction. uction(3) deviceTypeIsData( System cache type is data. 4) deviceTypeIsUnifi System cache type is both instruction and data. ed(5) Table 840.
deviceWritePolicy Device write policy is determined by I/O query. IsDeterminedByIO( 6) Table 842. Cache Device Status State Variable Name:DellCacheDeviceStatusState Data Type:Integer Possible Data Values Meaning of Data Value other(1) Device state is not one of the following: unknown(2) Device state is unknown. enabled(3) Device is enabled. userDisabled(4) Device is disabled by the user. biosDisabled(5) Device basic input/output system (BIOS) is disabled. Table 843.
deviceAssociativi Device is two-way set associative. tyIsTwoWaySetAsso ciative(4) deviceAssociativi Device is four-way set associative. tyIsFourWaySetAss o ciative(5) deviceAssociativi Device is fully associative. tyIsFullyAssociat ive (6) deviceAssociativi Device is eight-way set associative. tyIsEightWaySetAs so ciative(7) deviceAssociativi Device is sixteen-way set associative. tyIsSixteenWaySet Associative(8) deviceAssociativi Device is 12-way Set-Associative.
deviceSRAMTypeIsO Device SRAM type is not one of the following: ther(1) deviceSRAMTypeIsU Device SRAM type is unknown. nknown(2) deviceSRAMTypeIsN Device SRAM type is nonburst. onBurst(3) deviceSRAMTypeIsB Device SRAM type is burst. urst(4) deviceSRAMTypeIsP Device SRAM type is pipeburst. ipeBurst(5) deviceSRAMTypeIsS Device SRAM type is synchronous. ynchronous(6) deviceSRAMTypeIsA Device SRAM type is asynchronous. synchronous(7) Table 847.
deviceFormFactorI Device form factor is SRIMM. sSRIMM(14) deviceFormFactorI Device form factor is FB-DIMM. sFBDIMM(15) Table 848. Memory Device Type Variable Name:DellMemoryDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) Device type is not one of the following: deviceTypeIsUnkno Device type is unknown. wn(2) deviceTypeIsDRAM( Device type is DRAM. 3) deviceTypeIsEDRA M(4) Device type is EDRAM. deviceTypeIsVRAM( Device type is VRAM.
deviceTypeIsDDR2F Device type is DDR2 FB-DIMM. BDIMM(20) deviceTypeIsDDR3( Device type is DDR3. 24) deviceTypeIsFBD2( Device type is FBD2. 25) Table 849. Memory Device Type Details Variable Name:DellMemoryDeviceTypeDetails Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeDetailI The detailed device type is not one of the following: sOther(2) deviceTypeDetailI The detailed device type is unknown. sUnknown(4) deviceTypeDetailI The detailed device type is fast paged.
Table 850. Generic Device Type Variable Name:DellGenericDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) Device type is not one of the following: deviceTypeIsUnkno Device type is unknown. wn(2) deviceTypeIsAVide Device type is a video. oDevice(3) deviceTypeIsASCSI Device type is a SCSI controller. Controller(4) deviceTypeIsAnEth Device type is Ethernet. ernetDevice(5) deviceTypeIsToken Device type is token ring.
connected(1) Media reports that device is connected. disconnected(2) Media reports that device is disconnected. driverBad(3) Driver cannot be opened to determine status. driverDisabled(4) Driver is disabled. hardwareInitalizi Hardware is initializing. ng(10) hardwareResettin g(11) Hardware is resetting. hardwareClosing(1 Hardware is closing down. 2) hardwareNotReady( Hardware is not ready. 13) Table 853.
Table 855. Network Device RDMA Capability Flags Variable Name:DellNetworkDeviceRDMACapabilityFlags Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for RDMA capability is not supported. unknown(1) Querying for RDMA capability is supported but query returned an error. available(2) Device has RDMA capability. notAvailable(4) Device does not have RDMA capability.
Possible Data Values Meaning of Data Value other(1) Device type is other. unknown(2) Device type is unknown. hypervisor(3) Device type is Hypervisor. vFlash(4) Device type is Virtual Flash (vFlash.) Table 859. SD Card Device Config Capabilities Variable Name:DellSDCardDeviceConfigCapabilities Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) SD card device has none of the following capabilities.
standby(256) Device is in standby mode. Table 862. SD Card Device Card Licensed Variable Name:DellSDCardDeviceCardLicensed Data Type:Integer Possible Data Values Meaning of Data Value unlicensed(0) SD card is not licensed by system vendor. licensed(1) SD card is licensed by system vendor. ipmiReady(2) Device is IPMI ready. fullReady(4) Device is full ready. offline(8) Device is offline. failed(16) Device is failed. active(32) Device is active. bootable(64) Device is bootable.
14 Slot Group The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots. System Slot Group Table The System Slot Group defines objects in the System Slot MIB table. The following object sets up the System Slot Table: Table 863. System Slot Table Name systemSlotTable Object ID 1.3.6.1.4.1.674.10892.1.1200.
Table 866. System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis. Syntax DellObjectRange Access Read-only Table 867. System Slot State Capabilities Unique Name systemSlotStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.3 Description Defines the capabilities of the system slot.
Table 871. System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7 Description Defines the type of the system slot. Syntax DellSystemSlotType (System Slot Type) Access Read-only Table 872. System Slot External Slot Name Name systemSlotSlotExternalSlotName Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.8 Description Defines the external connector name of the system slot. Syntax DellString Access Read-only Table 873.
Table 876. System Slot Hot-Plug Bus Width Name systemSlotHotPlugBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12 Description Defines the bus width of the hot-plug system slot. Syntax DellSystemSlotHotPlugBusWidth (Hot-Plug Bus Width) Access Read-only Table 877. System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13 Description Defines the slot speed in megahertz of the hot-plug system slot.
systemSlotHotPlugCanSignal PowerFault(16) Power on fault (and corresponding LED) can be detected due to a short or overcurrent. systemSlotHotPlugCanSignal AdapterPresent(32) Adapter (card) present in slot (may not be powered) can be detected. systemSlotHotPlugCanSignal PowerButtonPressed(64) The system slot power button can be pressed to signal a toggle of the power state. canSupportAllHotPlugCapabi lities(126) The system slot can support all hot-plug capabilities.
systemSlotHotPlugAdapterIsPresent (32) Adapter (card) present in slot (may not be powered). systemSlotHotPlugAdapterPresentAnd PoweredOn(36) Adapter (card) present in slot and powered. systemSlotHotPlugPowerButtonPressed (64) The system slot power button pressed to signal a toggle of the power state. systemSlotProvides5Volts(128) The system slot provides a 5-V supply. systemSlotProvides3Point3Volts(256) The system slot provides a 3.3-V supply.
systemSlotIsPCMCIA(7) . The system slot is compliant with the Personal Computer Memory Card International Association (PCMCIA) standards systemSlotIsVLVESA(8) The system slot is Very Low Voltage Enterprise System Architecture (VLVESA). systemSlotIsProprietary(9) The system slot is proprietary. systemSlotIsProcessorCard(10) The system slot is a processor card. systemSlotIsProprietaryMemory(11) The system slot is proprietary memory. systemSlotIsIORiserCard(12) The system slot is an I/O riser card.
Table 882. System Slot Usage Variable Name: DellSystemSlotUsage Data Type: Integer Possible Data Values Meaning of Data Value systemSlotUsageIsOther(1) The system slot usage is not one of following: systemSlotUsageIsUnknown(2) The system slot usage is unknown. systemSlotUsageIsAvailable(3) The system slot is available. systemSlotUsageIsInUse(4) The system slot is in use. Table 883.
busWidthIs16bits(4) The system slot bus width is 16 bits. busWidthIs32bits(5) The system slot bus width is 32 bits. busWidthIs64bits(6) The system slot bus width is 64 bits. busWidthIs128bits(7) The system slot bus width is 128 bits. busWidthIs1xOrx1(8) The system slot bus width is 1x or x1. busWidthIs2xOrx2(9) The system slot bus width is 2x or x2. busWidthIs4xOrx4(10) The system slot bus width is 4x or x4. busWidthIs8xOrx8(11) The system slot bus width is 8x or x8.
15 Memory Group The Memory Group provides information about the physical memory in your system. Variables in this group include error correction type, location, and different types of memory use, such as cache, flash, system, video, and nonvolatile memory.
Syntax PhysicalMemoryArrayTableEntry Access Not accessible Table 887. Physical Memory Array Table Entry Name physicalMemoryArrayTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1 Description Defines the Physical Memory Array Table entry. Syntax PhysicalMemoryArrayTableEntry Access Not accessible Index physicalMemoryArraychassisIndex , physicalMemoryArrayIndex Table 888. Physical Memory Array Chassis Index Name physicalMemoryArraychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.
Table 891. Physical Memory Array State Settings Name physicalMemoryArrayStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.4 Description Defines the state of the physical memory array. Syntax DellStateSettings Access read-write Table 892. Physical Memory Array Status Name physicalMemoryArrayStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.5 Description Defines the status of the physical memory array. Syntax DellStatus Access Read-only Table 893.
Table 896. Physical Memory Array Maximum Size Name physicalMemoryArrayMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.9 Description Defines the size in KB of the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Table 897. Physical Memory Array Total Number Sockets Name physicalMemoryArrayTotalNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.10 Description Defines the total number of memory sockets available for the physical memory array.
Table 901. Physical Memory Array ECC Error Noncritical Threshold Name physicalMemoryArrayECCErrorNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.14 Description Defines the value of the physical memory array ECC error noncritical threshold. Syntax DellSigned32BitRange Access read-write Table 902. Physical Memory Array Redundant Memory Unit Index Reference Name physicalMemoryArrayRedundantMemoryUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
Table 905. Physical Memory Array Mapped Chassis Index Name physicalMemoryArrayMappedchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 906. Physical Memory Array Mapped Index Name physicalMemoryArrayMappedIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.2 Description Defines the index (one-based) of the memory array mapped address in this chassis.
Table 910. Physical Memory Array Index Reference Name physicalMemoryArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.6 Description Defines the index to the associated physical memory array in this chassis. Syntax DellObjectRange Access Read-only Table 911. Physical Memory Array Mapped Starting Address Name physicalMemoryArrayMappedStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.
Description Defines the Physical Memory Configuration Table. Syntax SEQUENCE OF PhysicalMemoryConfigTableEntry Access Not accessible Table 915. Physical Memory Configuration Table Entry Name physicalMemoryConfigTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1 Description Defines the Physical Memory Configuration Table entry. Syntax PhysicalMemoryConfigTableEntry Access Not accessible Index physicalMemoryConfigChassisIndex , physicalMemoryConfigIndex Table 916.
Table 919. Physical Memory Configuration State Settings Name physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4 Description Defines the state settings of the physical memory configuration. Syntax DellPhysicalMemoryConfigStateSettings Access Read-write Table 920. Physical Memory Configuration Status Name physicalMemoryConfigStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5 Description Defines the status of the physical memory configuration.
Table 924. Physical Memory Configuration MOM Settings Name physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9 Description Defines the Memory Operating Mode settings of the physical memory. Syntax DellPhysicalMemoryConfigMOMSettings Access Read-only Physical Memory Logging Table This table defines the conditions for logging system memory events. The following object sets up the Physical Memory Logging Table: Table 925.
Table 928. Physical Memory Logging Index Name physicalMemoryLoggingIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.2 Description Defines the index (one-based) of the physical memory logging. Syntax DellObjectRange Access Read-only Table 929. Physical Memory Logging Capabilities Name physicalMemoryLoggingCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.3 Description Defines the capabilities of the physical memory logging.
Access Not accessible Table 933. Redundant Memory Unit Table Entry Name redundantMemoryUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1 Description Defines the Redundant Memory Unit Table entry. Syntax RedundantMemoryUnitTableEntry Access Not accessible Index redundantMemoryUnitChassisIndex , redundantMemoryUnitIndex Table 934. Redundant Memory Unit Chassis Index Name redundantMemoryUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.
Table 937. Redundant Memory Unit State Settings Name redundantMemoryUnitStatesettings Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.4 Description Defines the state settings of the redundant memory unit. Syntax DellStateSettings Access Read-write Table 938. Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5 Description Defines the redundancy status of the redundant memory unit.
Description Defines the Physical Memory Card Table. Syntax SEQUENCE OF PhysicalMemoryCardTableEntry Access Not accessible Table 942. Physical Memory Card Table Entry Name physicalMemoryCardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1 Description Defines the Physical Memory Card Table Entry. Syntax PhysicalMemoryCardTableEntry Access Not accessible Index physicalMemoryCardChassisIndex , physicalMemoryCardIndex Table 943.
Table 946. Physical Memory Card State Settings Name physicalMemoryCardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.4 Description Defines the state settings of the Physical Memory Card. Syntax DellStateSettings Access Read-write Table 947. Physical Memory Card Status Name physicalMemoryCardStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.5 Description Defines the status of the Physical Memory Card. Syntax DellStatus Access Read-only Table 948.
Access Read-only Table 951. Physical Memory Card Physical Memory Array Index Reference Name physicalMemoryCardPhyMemArrayIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.9 Description Defines the index (one-based) of the Physical Memory Array Table entry for the physical memory array with the same chassis index that this physical memory card is associated with.
Table 953. Physical Memory Array ECC Type Definitions Variable Name: DellPhysicalMemoryArrayECCType Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayECCTypeIsOther(1) There is not one of the following: memoryArrayECCTypeIsUnknown(2) The memory array ECC type is unknown. memoryArrayECCTypeIsNone(3) The memory array ECC type is none. memoryArrayECCTypeIsParity(4) The memory array ECC type is parity.
Table 956. Physical Memory Configuration Redundant Capabilities Variable Name: DellPhysicalMemoryConfigRedundantCapabilities Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no redundant memory capabilities. unknownCapabilities(1) Redundant capabilities are unknown. The redundant capabilities are: spareCapable(2) Spare redundant memory feature is supported. mirrorCapable(4) Mirror redundant memory feature is supported.
Table 959. Physical Memory Logging Settings Variable Name: DellPhysicalMemoryLoggingSettings Data Type: Integer Possible Data Values Meaning of Data Value If set to 0 (zero) There are no logging settings enabled. unknown Capabilities(1) Logging capabilities are unknown. The logging settings are: enabled(2) Logging is disabled (0), or enabled (1).
BIOS Setup Control Group 16 Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system. This management information base (MIB) group includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs), and the Wakeup on local area network (LAN) feature.
Access Not accessible Index biosSetUpControlchassisIndex Table 962. BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 963. BIOS Setup Control (BSUC) Pointing Device Control Capabilities Name bSUCpointingDeviceControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Access Read-only Table 967. BIOS Setup Control Numeric Lock Control Capabilities Name bSUCnumLockControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.6 Description Defines the capabilities of the numeric lock. Syntax DellStateCapabilities Access Read-only Table 968. BIOS Setup Control Numeric Lock Control Settings Name bSUCnumLockControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.7 Description Defines the state of the numeric lock.
Access Read-only Table 972. BIOS Setup Control Processor Serial Number Control Settings Name bSUCprocessorSerialNumberControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.11 Description Defines the state of the processor serial number. Syntax DellStateSettings Access Read-only Table 973. BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Access Read-only Table 977. BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only Table 978. BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17 Description Defines the setup BIOS name of the speaker control. Syntax DellString Access Read-only Table 979.
Syntax DellStatus Access Read-only Table 982. BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN. Syntax DellString Access Read-only Table 983. BIOS Setup Control Boot Sequence Control Capabilities Unique Name bSUCbootSequenceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Syntax DellString Access Read-only Table 987. BIOS Setup Control Administrator Password Control Capabilities Unique Name bSUCadministratorPasswordControlCapabilities Unique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.26 Description Defines the capabilities of the administrator password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only Table 988.
Description Defines the setup BIOS name of the new administrator password. To set a new administrator password, you must have successfully set the current administrator password immediately preceding this password change. Syntax DellString Access Read-write Table 992. BIOS Setup Control User Password Control Capabilities Unique Name bSUCuserPasswordControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.31 Description Defines the capabilities of user password control.
Description Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user password immediately preceding this password change. Syntax DellString Access Read-write Table 997. BIOS Setup Control TPM Security Control Capabilities Name bSUCtpmSecurityControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.36 Description Defines the BIOS setup control capabilities of Trusted Platform Module (TPM) security.
SCSI Control Table Table 1001. SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table. Syntax SCSIControlTableEntry Access Not accessible Table 1002. SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1 Description x Defines the SCSI Control Table entry.
Syntax DellStateCapabilities Access Read-only Table 1006. SCSI Control Settings Name sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4 Description Defines the state of the SCSI controller. Syntax DellStateSettings Access Read-only Table 1007. SCSI Control Status Name sCSIControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.5 Description Defines the status of the SCSI controller. Syntax DellStatus Access Read-only Table 1008.
Access Not accessible Index parallelPortControlchassisIndex , parallelPortControlIndex Table 1011. Parallel Port Control Chassis Index Name parallelPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1012. Parallel Port Control Index Name parallelPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.
Access Read-only Table 1016. Parallel Port Control Name Name parallelPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6 Description Defines the setup BIOS name of the parallel port. Syntax DellString Access Read-only Table 1017. Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7 Description Defines the mode capabilities of the parallel port.
Index serialPortControlchassisIndex , serialPortControlIndex Table 1021. Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Table 1022. Serial Port Control Index Name serialPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2 Description Defines the index (one-based) of the serial port in this chassis.
Table 1026. Serial Port Control Name Name serialPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6 Description Defines the setup BIOS name of the serial port. Syntax DellString Access Read-only USB Control Table These objects enable you to track the attributes of your Universal Serial Bus (USB). Table 1027. USB Control Table Name usbControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.50 Description Defines the USB Table.
Syntax DellObjectRange Access Read-only Table 1031. USB Control Capabilities Name usbControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3 Description Defines the capabilities of the USB. Syntax DellStateCapabilities Access Read-only Table 1032. USB Control Settings Name usbControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.4 Description Defines the control settings for the USB. Syntax DellStateSettings Access Read-only Table 1033.
Access Not accessible Table 1036. IDE Control Table Entry Name ideControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1 Description Defines the IDE Control Table entry. Syntax IdeControlTableEntry Access Not accessible Index ideControlchassisIndex , ideControlIndex Table 1037. IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis.
Access Read-only Table 1041. IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only Table 1042. IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6 Description Defines the setup BIOS name for the IDE controller. Syntax DellStatus Access Read-only Diskette Control Table Table 1043.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1046. Diskette Control Index Name disketteControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2 Description Defines the index of the diskette controllers in this chassis. Syntax DellObjectRange Access Read-only Table 1047. Diskette Control Capabilities Unique Name disketteControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.
Network Interface Control Table These MIB objects enable you to track the attributes of the NIC card for your system. Table 1051. Network Interface Control Table Name networkInterfaceControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.80 Description Defines the Network Interface Control Table. Syntax NetworkInterfaceControlTableEntry Access Not accessible Table 1052. Network Interface Control Table Entry Name networkInterfaceControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.80.
Syntax DellNetworkInterfaceControlCapabilitiesUnique (See Network Interface Control Capabilities) Access Read-only Table 1056. Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.4 Description Defines the control settings for the NIC. Syntax DellNetworkInterfaceControlSettingsUnique (See Network Interface Control Settings) Access Read-write Table 1057.
Table 1060. BIOS Setting Table Entry Name biosSettingTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1 Description Defines the BIOS Setting Table Entry. Syntax BiosSettingTableEntry Access Not accessible Index biosSettingChassisIndex , biosSettingIndex Table 1061. BIOS Setting Chassis Index Name biosSettingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.1 Description Defines the index (one based) of the associated chassis.
Table 1065. BIOS Setting Value Type Name biosSettingValueType Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.5 Description Defines the type of the BIOS setting value. Syntax DellBIOSSettingValueType Access Read-only Table 1066. BIOS Setting Current Value Name biosSettingCurrentValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.6 Description Defines the current value of the BIOS setting. Syntax DisplayString Access Read-only Table 1067.
Description Defines the recommended display order of the BIOS setting within its BIOS setting group. Syntax DellUnsigned32BitRange Access Read-only Table 1071. BIOS Setting Group Display Name Name biosSettingGroupDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.11 Description Defines the display name of the BIOS setting group for the BIOS setting. Syntax DisplayString Access Read-only Table 1072. BIOS Setting FQDD Name biosSettingFQDD Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.
unknown(1) Speaker control state is unknown. enabled(2) Speaker control is enabled. low(4) Speaker control volume is low. medium(8) Speaker control volume is medium. high(16) Speaker control volume is high. Table 1075. Network Interface (NIF) Wakeup on LAN Capabilities Unique Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown.
bootFromhardDriveFirstCapable (4) Setup BIOS can boot from an IDE hard drive first. bootFromDisketteORHardDrive FirstCapable(6) Setup BIOS can boot from a diskette or an IDE hard drive first. bootFromDeviceListCapable(8) Setup BIOS can boot from a device list. bootFromCDROMFirstCapable(16) Setup BIOS can boot from a CD first. allFirstCapable(30) Setup BIOS can boot by any of the preceding methods first. Table 1078.
passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 1081. BIOS Password Control Settings Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) Setup BIOS password state is unknown. passwordControlEnabled(2) Setup BIOS has password changes enabled.
lpt2Capable(8) Setup BIOS can support parallel port 2. lpt2andEnableCapable(10) Setup BIOS has enabled parallel port 2. lpt3Capable(16) Setup BIOS can support parallel port 3. lpt3andEnableCapable(18) Setup BIOS has enabled parallel port 3. allParallelPortCapable(30) Setup BIOS can support any of the three parallel ports. Table 1085.
enableCapable(2) Setup BIOS can enable the serial port. com1Capable(4) Setup BIOS can support serial port 1. enableAndCom1Capable(6) Setup BIOS can enable serial port 1. com2Capable(8) Setup BIOS can support serial port 2. enableAndCom2Capable(10) Setup BIOS is capable of enabling serial port 2. com3Capable(16) Setup BIOS can support serial port 3. enableAndCom3Capable(18) Setup BIOS is capable of enabling serial port 3. com4Capable(32) Setup BIOS can support serial port 4.
Table 1089. IDE Control Capabilities Variable Name: DellideControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) IDE control capabilities are unknown. ideControlAutoConfigOrEnable Capable(2) IDE controller is autoconfigurable or enable capable. Table 1090. Diskette Control Settings Variable Name: DellDisketteControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Diskette control state is unknown.
integer(1) Value type is integer. string(2) Value type is string. enumeration(3) Value type is enumeration. orderedList(4) Value type is ordered list.
Local Response Agent Group 17 The Local Response Agent Group provides information about various attributes of your system’s local response agent (LRA). The LRA allows systems managers to predetermine how a system running the server administrator responds to a particular event type, such as the loss of redundancy in a specific component or the elevation of temperature in a chassis. Systems managers can configure the LRA to respond to an event type with a specific action.
Syntax LRAGlobalSettingsTableEntry Access Not accessible Index lRAGlobalchassisIndex Table 1096. LRA Global Chassis Index Name lRAGlobalchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1097. LRA Global State Name lRAGlobalState Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.2 Description Defines the state of the LRA global settings.
Description Defines the set of thermal shutdown capabilities that are supported by the LRA. Syntax DellLRAThermalShutdownCapabilitiesUnique Access Read-only Table 1101. LRA Global Thermal Shutdown State Settings Unique Name lRAGlobalThermalShutdownStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.6 Description Defines the set of thermal shutdown state and settings that the local response agent supports.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1105. LRA Action Table Action Number Index Name lRAActionTableActionNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.2 Description Defines the LRA action number index.
Syntax DisplayString (SIZE (0..256) Access Read-write Table 1107. LRA Action Table Settings Unique Name lRAActionTableSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.4 Description Defines the LRA settings. Syntax DellLocalResponseAgentSettingsUnique (Local Response Agent Settings Unique) Access Read-write Local Response Agent Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 1108.
warningCapable(4) The LRA can carry out chassis-determined action(s) when a warning condition is detected. enableOnWarningCapable(6) The LRA enables activation of chassisdetermined action(s) when a warning condition is detected. failureCapable(8) The LRA can carry out chassis-determined action(s) when a failure condition is detected. enableOnFailureCapable(10) The LRA enables activation of chassisdetermined action(s) when a failure condition is detected.
Cost of Ownership Group 18 The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can use these management information base (MIB) objects to obtain accurate and complete measurements of the cost of each computer asset in your organization.
Syntax CooTableEntry Access Not accessible Index coochassisIndex Table 1113. COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only Table 1114. COO State Name cooState Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.2 Description Defines the acquisition state of the system. Syntax DellStateSettings Access Read-only Table 1115.
Syntax DellDateName Access Read-write Table 1118. COO Acquisition Purchase Order Name cooAquisitionPurchaseOrder Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.6 Description Defines the purchase order number of the system. Syntax DellUnsigned32BitRange Access Read-write Table 1119. COO Acquisition Purchase Date Name Name cooAquisitionPurchaseDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.7 Description Defines the purchase date and time of the system.
Access Read-only Table 1123. COO Cost Center Information Vendor Name Name cooCostCenterInformationVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.11 Description Defines the cost center name of the system. Syntax DellCostofOwnershipString Access Read-write Table 1124. COO User Information User Name Name cooUserInformationUserName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12 Description Defines the name of the user for this system.
Access Read-write Table 1128. COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-write Table 1129. COO Ownership Code Name cooOwnershipCode Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17 Description Defines the ownership code for this system.
Access Read-write Table 1133. COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system. Syntax DellCooHourDayDurationType (See COO Hour Day Duration Type) Access Read-write Table 1134. COO Training Name Name cooTrainingName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.22 Description Defines the training that the user has for this system.
Access Read-write Table 1138. COO Outsourcing Provider Fee Name Name cooOutsourcingProviderFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26 Description Defines any additional outsourcing charge for service. Syntax DellCostofOwnershipString Access Read-write Table 1139. COO Outsourcing Provider Service Level Name Name cooOutsourcingProviderServiceLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.27 Description Defines the service level agreement for the system.
Access Read-write Table 1143. COO Box Central Processing Unit (CPU) Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.31 Description Defines the name of the CPU serial number for the system. Syntax DellCostofOwnershipString Access Read-write Table 1144. COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system.
Access Read-write Table 1148. COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-write Table 1149. COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system.
Description Defines the COO Service Contract Table. Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible Table 1153. COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1 Description Defines the COO Service Contract Table entry. Syntax CooServiceContractTableEntry Access Not accessible Index cooServiceContractchassisIndex , cooServiceContractIndex Table 1154.
Table 1157. COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed. Syntax DellBoolean Access Read-write Table 1158. COO Service Contract Type Name Name cooServiceContractTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.5 Description Defines the name of the service contract type for this system.
Syntax cooCostEventLogTableEntry Access Not accessible Index cooCostEventLogchassisIndex , cooCostEventLogIndex Table 1162. COO Cost Event Log Chassis Index Name cooCostEventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1163. COO Cost Event Log Index Name cooCostEventLogIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.
Table 1166. COO Cost Event Log Duration Type Name cooCostEventLogDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.5 Description Defines the duration type of the event for this system. Syntax DellCOOHourDayDurationType (See COO Hour Day Duration Type) Access Read-write Table 1167. COO Cost Event Log Description Name Name cooCostEventLogDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.6 Description Defines the name of the event description.
Table 1170. COO Warranty Chassis Index Name cooWarrantychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-write Table 1171. COO Warranty Index Name cooWarrantyIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.2 Description Defines the index of the warranty for this system. Syntax DellObjectRange Access Read-only Table 1172. COO Warranty State Name cooWarrantyState Object ID 1.3.6.
Table 1175. COO Warranty End Date Name Name cooWarrantyEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.6 Description Defines the warranty end date for this system. Syntax DellDateName Access Read-write Table 1176. COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7 Description Defines the cost of the warranty for this system.
Table 1179. COO Lease Information Chassis Index Name cooLeaseInformationchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1180. COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system. Syntax DellObjectRange Access Read-only Table 1181.
Table 1184. COO Lease Information Lease Rate Factor Name cooLeaseInformationLeaseRateFactor Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.6 Description Defines the rate factor for the lease on this system. Syntax DellUnsigned32BitRange Access Read-write Table 1185. COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system.
Access Not accessible Table 1189. COO Schedule Number Table Entry Name cooScheduleNumberTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1 Description Defines the COO Schedule Number Information Table entry. Syntax CooScheduleNumberTableEntry Access Not accessible Index cooScheduleNumberchassisIndex , cooScheduleNumberIndex Table 1190. COO Schedule Number Chassis Index Name cooScheduleNumberchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.
Description Defines the lease information index number to reference the schedule number. Syntax DellUnsigned32BitRange Access Read-write Table 1194. COO Schedule Number Description Name Name cooScheduleNumberDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.5 Description Describes the schedule number information. Syntax DellCostofOwnershipString Access Read-write COO Options Table Table 1195. COO Options Table Name cooOptionsTable Object ID 1.3.6.1.4.1.674.10892.1.1600.
Access Read-only Table 1198. COO Options Index Name cooOptionsIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.2 Description Defines the index (one-based) of the option information for this system. Syntax DellObjectRange Access Read-only Table 1199. COO Options State Name cooOptionsState Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.3 Description Defines the option information state for this system. Syntax DellStateSettings Access Read-only Table 1200.
Syntax SEQUENCE OF CooMaintenanceTableEntry Access Not accessible Table 1203. COO Maintenance Table Entry Name cooMaintenanceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1 Description Defines the COO Maintenance Table entry. Syntax CooMaintenanceTableEntry Access Not accessible Index cooMaintenancechassisIndex , cooMaintenanceIndex Table 1204. COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.
Table 1207. COO Maintenance Start Date Name Name cooMaintenanceStartDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.4 Description Defines the start date for maintenance on this system. Syntax DellDateName Access Read-write Table 1208. COO Maintenance End Date Name Name cooMaintenanceEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.5 Description Defines the end date for maintenance on this system. Syntax DellDateName Access Read-write Table 1209.
Access Not accessible Table 1212. COO Repair Table Entry Name cooRepairTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1 Description Defines the COO Repair Table entry. Syntax CooRepairTableEntry Access Not accessible Index cooRepairchassisIndex , cooRepairIndex Table 1213. COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis.
Description Defines the number of repairs that this system has undergone. Syntax DellCostofOwnershipString Access Read-write Table 1217. COO Repair Vendor Name Name cooRepairVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.5 Description Defines the name of the vendor that repairs this system. Syntax DellStateSettings Access Read-only COO Support Information Table Table 1218. COO Support Information Table Name cooSupportInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.
Access Read-only Table 1221. COO Support Information Index Name cooSupportInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.2 Description Defines the index (one-based) for this system’s support information. Syntax DellObjectRange Access Read-only Table 1222. COO Support Information State Name cooSupportInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.3 Description Defines the support information state for this system.
Access Read-write Table 1226. COO Support Information Fix Type Name Name cooSupportInformationFixTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.7 Description Defines the method used to fix the problem. Syntax DellCostofOwnershipString Access Read-write COO Trouble Ticket Table The MIB objects in the Trouble Ticket Table enable you to track details of any trouble tickets that you open for your system. Table 1227. COO Trouble Ticket Table Name cooTroubleTicketTable Object ID 1.3.6.1.4.
Table 1230. COO Trouble Ticket Index Name cooTroubleTicketIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.2 Description Defines the index (one-based) of the system’s trouble ticket information. Syntax DellObjectRange Access Read-only Table 1231. COO Trouble Ticket State Name cooTroubleTicketState Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.3 Description Defines the trouble ticket information state for this system. Syntax DellStateSettings Access Read-only Table 1232.
unknown(2) The ownership code is unknown. owned(3) The ownership code is owned. leased(4) The ownership code is leased. rented(5) The ownership code is rented. offOfLease(6) The ownership code is off of lease. transfer(7) The ownership code is transfer. Table 1235. COO Hour Day Duration Type Variable Name: DellCooHourDayDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. hours(2) Duration time type is in hours.
Remote Access Group 19 The Remote Access Group provides information about the remote access hardware that may be present in your system. In addition to providing general information about the capabilities and settings of the remote access hardware, this group provides information about administrative users, SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration, and dial-out destinations.
Access Read-only Table 1241. Remote Access Adapter Index Name remoteAccessAdapterIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.2 Description Defines the index (one-based) of the remote access hardware. Syntax DellObjectRange Access Read-only Table 1242. Remote Access Type Name remoteAccessType Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.3 Description Defines the type of remote access hardware. Syntax DellRemoteAccessType (Remote Access Type) Access Read-only Table 1243.
Table 1246. Remote Access Product Info Name Name remoteAccessProductInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.7 Description Defines the name of the product providing the remote access functionality. Syntax DellDisplayString Access Read-only Table 1247. Remote Access Description Info Name Name remoteAccessDescriptionInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.8 Description Defines the description of the product providing the remote access functionality.
Description Defines the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Table 1252. Remote Access NIC Static Netmask Address Name remoteAccessNICStaticNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.26 Description Defines the netmask for the static IP address to be used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-write Table 1253.
Description Defines the IP address currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Table 1257. Remote Access NIC Current Netmask Address Name remoteAccessNICCurrentNetmaskAddress Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.31 Description Defines the netmask currently being used by the integrated NIC provided by the remote access hardware. Syntax IpAddress Access Read-only Table 1258.
Table 1261. Remote Access Type Variable Name:DellRemoteAccessType Data Type:Integer Possible Data Values Meaning of Data Value remoteAccessType IsOther(1) The remote access type is not one of the following: remoteAccessType IsUnknown(2) The remote access type is unknown. remoteAccessType IsDRACIII(3) The remote access type is DRAC III. remoteAccessType IsERA(4) The remote access type is ERA. Table 1262.
hardReset(4) The remote access hardware performs a hard reset. softReset(8) The remote access hardware performs a soft reset. gracefulReset(16 ) The remote access hardware shuts down and perform a soft reset. defaultConfigRes et(32) The remote access hardware resets to its default settings. shutdown(64) The remote access hardware shuts down. Table 1264.
none(0) The remote access hardware has no LAN capabilities. unknownCapabilit ies(1) The remote access hardware LAN capabilities are unknown. nicCapable(2) The remote access hardware has a network interface controller (NIC). nicDHCPCapable(4 ) The remote access hardware NIC can use DHCP to obtain an IP address. Table 1267.
smtpEmailEnable d(2) The remote access hardware SMTP client is enabled for sending e-mail. tftpRemoteFloppy Enabled(4) The remote access hardware TFTP client is enabled for remote floppy boot. tftpRemoteFwUpda teEnabled(8) The remote access hardware TFTP client is enabled for remote firmware update. Table 1270.
numericPagerCapa ble(8) The admin user supports numeric paging. alphaPagerCapabl e(16) The admin user supports alphanumeric paging. emailCapable(32) The admin user supports e-mail. privilegeCapabl e(64) The admin user supports user privileges configuration. Table 1273. Remote User Admin State Settings Variable Name:DellRemoteUserAdminStateSettings Data Type:Integer Possible Data Values Meaning of Data Value none(0) The admin user has no state settings.
numericPagerTes t(2) A numeric pager test is performed for the admin user. alphaPagerTest(4 ) An alphanumeric pager test is performed for the admin user. emailTest(8) An e-mail test is performed for the admin user. Table 1276.
Table 1279. Remote SNMP Trap State Settings Variable Name:DellRemoteSNMPTrapStateSettings Data Type:Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no state settings. unknown(1) The SNMP trap destination state settings are unknown. enabled(2) The SNMP trap destination is enabled. notReady(4) The SNMP trap destination is in the not ready state. Table 1280.
dialInCapable(8) The dial-up functionality can support the dial-in feature. dialOutCapable(1 6) The dial-up functionality can support the dial-out feature. dialInDHCPCapabl e(32) The dial-up functionality can support using DHCP to obtain an IP address for the dial-in feature. dialInAuthAnyCap able(64) The dial-up functionality can support any authentication type (including clear text) for the dial-in feature.
remoteDialUpIsOt her(1) The remote dial type is not one of the following: remoteDialUpIsUn known(2) The remote dial type is unknown. remoteDialUpIsTo ne(3) The remote dial type is tone. remoteDialUpIsPu lse(4) The remote dial type is pulse. Table 1285. Remote User Dial-In State Capabilities Variable Name:DellRemoteUserDialInStateCapabilities Data Type:Integer Possible Data Values Meaning of Data Value none(0) The dial-in user has no state capabilities.
none(0) The dial-out destination has no state capabilities. unknownCapabilit ies(1) The dial-out destination state capabilities are unknown. enableCapable(2) The dial-out destination can be disabled or enabled. notReadyCapable( 4) The dial-out destination can be in the not ready state. dialOutPPPAuthAn yCapable(8) The dial-out destination can support any authentication type (including clear text) for PPP.
20 Cluster Group Clustering combines multiple systems in such a way that they provide services a single system cannot. Clustering enhances higher availability, scalability, and management. Higher availability is achieved by using failover clusters, in which resources can automatically move between two or more systems in the event of a failure. Scalability is achieved by balancing the load of an application across several computer systems.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1292. Cluster Index Name clusterIndex Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.2 Description Defines the index (one-based) of the cluster. Syntax DellObjectRange Access Read-only Table 1293. Cluster State Capabilities Name clusterStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.3 Description Defines the state capabilities of the cluster.
Table 1297. Cluster Type Description Name Name clusterTypeDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.7 Description Defines the description name for the type of the cluster. Syntax DellString Access Read-only Table 1298. Cluster Name Name clusterName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.8 Description Defines the name of the cluster.
Baseboard Management Controller Group 21 The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system.
, bmcIndex Table 1302. BMC Chassis Index Name bmcChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1303. BMC Index Name bmcIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.2 Description Defines the index (one-based) of the BMC. Syntax DellObjectRange Access Read-only Table 1304. BMC State Capabilities Name bmcStateCapabilities Object ID 1.3.6.1.4.1.674.10892.
Table 1307. BMC Display Name Name bmcDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.6 Description Defines the display name of the BMC. Syntax DellString Access Read-only Table 1308. BMC Description Name Name bmcDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.7 Description Defines the description of the BMC. Syntax DisplayString (SIZE (0..255)) Access Read-only Table 1309. BMC IPMI Version Name Name bmcIPMIVersionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.
Description Defines the module name for the BMC. The module name is present only on certain systems, such as modular systems. Syntax DellString Access Read-only Table 1313. BMC IPv4 URL Name Name bmcIPv4URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.12 Description Defines the IPv4 URL for the BMC. The URL is not present on all systems. Syntax DisplayString (SIZE (0..1024)) Access Read-only Table 1314. BMC IPv6 URL Name Name bmcIPv6URLName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.
, bmcSerialInterfaceIndex Table 1317. BMC Serial Interface Chassis Index Name bmcSerialInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1318. BMC Serial Interface BMC Index Name bmcSerialInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.2 Description Defines the index (one-based) of the associated BMC.
Table 1322. BMC Serial Interface Status Name bmcSerialInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.6 Description Defines the status of the BMC serial interface. Syntax DellStatus Access Read-only Table 1323. BMC Serial Interface Channel Number Name bmcSerialInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.7 Description Defines the BMC channel number of the BMC serial interface. Syntax DellUnsigned8BitRange Access Read-only Table 1324.
Description Defines the bit rate of the BMC serial interface. Syntax DellBMCSerialBitRateType Access Read-only Baseboard Management Controller LAN Interface Table Table 1328. BMC LAN Interface Name bmcLANInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.30 Description Defines the Baseboard Management Controller (BMC) LAN Interface Table. Syntax SEQUENCE OF BmcLANInterfaceTableEntry Access Not accessible Table 1329.
Access Read-only Table 1332. BMC LAN Interface Index Name bmcLANInterfaceIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.3 Description Defines the index (one-based) of the BMC LAN interface. Syntax DellObjectRange Access Read-only Table 1333. BMC LAN Interface State Capabilities Name bmcLANInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.4 Description Defines the state capabilities of the BMC LAN interface.
Table 1337. BMC LAN Interface IP Address Source Name bmcLANInterfaceIPAddressSource Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.8 Description Defines the source type of the IP address of the BMC LAN interface. Syntax DellBMCLANIPAddressSourceType Access Read-only Table 1338. BMC LAN Interface IP Address Name bmcLANInterfaceIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.9 Description Defines the IP address of the BMC LAN interface. Syntax IpAddress Access Read-only Table 1339.
Description Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface. Syntax DisplayString (SIZE (0..32)) Access Read-only Baseboard Management Controller Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 1343. Baseboard Management Controller Variable Name:DellBMCSerialConnectionModeCapabilities Data Type:Integer These values are bit masks; therefore, combination values are possible.
Table 1345. BMC Serial Flow Control Type Variable Name:DellBMCSerialFlowControlType Data Type:Integer Possible Data Values Meaning of Data Value -- none(0) No flow control used. rtscts(1) RTS/CTS (hardware) flow control used. xonXoff(2) XON/XOFF flow control used. Table 1346.
iDRAC6(10) Controller type is Integrated Dell Remote Access Controller 6. iDRAC6Modular(11) Controller type is Integrated Dell Remote Access Controller 6 (Modular). iDRAC6BMC(13) Controller type is Integrated Dell Remote Access Controller 6 (BMC mode). iDRAC7(16) Controller type is Integrated Dell Remote Access Controller 7. iDRAC7Modular(17) Controller type is Integrated Dell Remote Access Controller 7 (Modular).
Field Replaceable Unit Group 22 A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the system to a repair facility. The Field Replaceable Unit Group provides information about the field replaceable units that may be present in your system. Field Replaceable Unit Group Tables The objects in the FRU group define information such as manufacturer, serial number, part number and revision for field replaceable units. The following MIB tables define the FRU group.
Table 1352. FRU Index Name fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2 Description Defines the index (one-based) of the FRU. Syntax DellObjectRange Access Read-only Table 1353. FRU Information Status Name fruInformationStatus Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.3 Description Defines the status of the FRU table entry. Syntax DellStatus Access Read-only Table 1354. FRU Information State Name fruInformationState Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.
Description Defines the serial number of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1358. FRU Part Number Name Name fruPartNumberName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.8 Description Defines the part number of the FRU Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1359. FRU Revision Name Name fruRevisionName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.9 Description Defines the revision of the FRU. Syntax DisplayString (SIZE (0..
Possible Data Values Meaning of Data Value ok(1) FRU information is okay. notSupported(2) FRU information is not supported. notAvailable(3) FRU information is not available. checksumInvalid(4) FRU information checksum is invalid. corrupted(5) FRU information is corrupted.
Storage Management Group 23 The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software. • Storage Management Event Group—SNMP traps.
Syntax Integer Access Read-only Table 1365. Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.3 Description Identifies the manufacturer of the Storage Management software. Syntax DisplayString Access Read-only Table 1366. Software Product Name softwareProduct Object ID 1.3.6.1.4.1.674.10893.1.20.4 Description Identifies product information for the Storage Management software. Syntax DisplayString Access Read-only Table 1367.
Table 1369. Description Name description Object ID 1.3.6.1.4.1.674.10893.1.20.100.2 Description Provides a short description of this management software. Syntax DisplayString Access Read-only Table 1370. Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.3 Description Identifies the name of the management software manufacturer. Syntax DisplayString Access Read-only Table 1371. Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.
Syntax Integer Access Read-only Table 1374. Agent Time Stamp Name agentTimeStamp Object ID 1.3.6.1.4.1.674.10893.1.20.110.3 Description Identifies the last time that the agent values have been updated. Universal time in seconds since UTC 1/1/70. Syntax Integer Access Read-only Table 1375. Agent Get Timeout Name agentGetTimeout Object ID 1.3.6.1.4.1.674.10893.1.20.110.
Table 1378. Agent Hostname Name agentHostname Object ID 1.3.6.1.4.1.674.10893.1.20.110.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1379. Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.8 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1380. Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.
Table 1383. Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Table 1384. Agent Global System Status Name agentGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.13 Description Global health information for the subsystem managed by the Storage Management software.
Access Read-only Table 1386. Agent Smart Thermal Shutdown Name agentSmartThermalShutdown Object ID 1.3.6.1.4.1.674.10893.1.20.110.15 Description Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S enclosures.
• Battery Connection Table — describes the connection between each battery on the managed system and its controller. Each controller number in the table corresponds to that controller instance in the Controller Table. Controller Table This table describes available properties for each controller on the managed system. The following object sets up the Controller Table. Table 1387. Controller Table Name controllerTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.
Syntax DisplayString Access Read-only Table 1391. Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's (re)seller's name. Syntax DisplayString Access Read-only Table 1392. Controller Type Name controllerType Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1394. Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Name controllerRebuildRateInPercent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.7 Description Identifies the percent of the compute cycles dedicated to rebuilding failed array disks.
Access Read-only Table 1398. Controller Physical Device Count Name controllerPhysicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.11 Description Identifies the number of physical devices on the controller channel including both disks and the controller. Syntax Integer Access Read-only Table 1399. Controller Logical Device Count Name controllerLogicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.12 Description Identifies the number of virtual disks on the controller.
Access Read-only Table 1403. Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16 Description Identifies the size of memory on the controller that is less than a megabyte. This combined with the controllerMemorySizeInMB is the total size of the memory. This attribute is only supported on Adaptec controllers. Syntax Integer Access Read-only Table 1404. Controller Drive Channel Count Name controllerDriveChannelCount Object ID 1.3.6.
Access Read-only Table 1408. Controller C0 Port 0 ID Name controllerC0Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1409. Controller C0 Target Name controllerC0Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.22 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1410.
Access Read-only Table 1413. Controller C1 Port 0 World Wide Name Name controllerC1Port0WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.26 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1414. Controller C1 Port 0 Name Name controllerC1Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.27 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Access Read-only Table 1418. Controller C1 Operating System Controller Name controllerC1OSController Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.31 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1419. Controller Battery State C1 Name controllerC1BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.32 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Access Read-only Table 1423. Controller Battery Charge Count Name controllerBatteryChargeCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.36 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1424. Controller Roll-Up Status Name controllerRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.37 Description Indicates severity of the controller state.
Table 1426. Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.39 Description Durable unique ID for this controller. Syntax DisplayString Access Read-only Table 1427. Controller Alarm State Name controllerAlarmState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.40 Description Indicates state, or setting for the controller's alarm. Possible values: 1: Enabled 2: Disabled 3: Not Applicable Syntax Integer Access Read-only Table 1428.
Possible values: 1: Enabled 2: Disabled 3: Active (enabled and active) 99: Not Applicable Syntax Integer Access Read-only Table 1431. Controller Minimum Firmware Version Name controllerMinFWVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.44 Description The minimum firmware version for Storage Management to support the controller. Syntax DisplayString Access Read-only Table 1432. Controller Minimum Driver Version Name controllerMinDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.
Table 1435. Controller Reconstruct Rate Name controllerReconstructRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.48 Description The rate for reconstruct on the controller. Syntax Integer Access Read-write Table 1436. Controller Patrol Read Rate Name controllerPatrolReadRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.49 Description The rate for patrol read on the controller. Syntax Integer Access Read-only Table 1437. Controller BGI Rate Name controllerBGIRate Object ID 1.3.6.
Table 1440. Controller Patrol Read State Name controllerPatrolReadState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.53 Description The state of the patrol read. Possible values: 1: Stopped - not running 2: Ready - ready to start 4: Active - is running 8: Aborted - has aborted Syntax Integer Access Read-only Table 1441. Controller Patrol Read Iterations Name controllerPatrolReadIterations Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Description Indicates encryption capability of the controller. Value: 1 - Capable, 99 - Not Applicable Syntax Integer Access Read-only Name controllerEncryptionKeyPresent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.58 Description Indicates presence of encryption key for the controller. Value: 1 - Yes, 0 - No, 99 - Not Applicable Syntax Integer Access Read-only Table 1445. Controller Persistent Hot Spare Name controllerPersistentHotSpare Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1448. Controller Spin Down Time Interval Name controllerSpinDownTimeInterval Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.62 Description Shows the duration in minutes after which, the unconfigured or hot spare drives is spun down to power save mode. Value: 30 to 1440 NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-write Table 1449. Controller Encryption Mode Name controllerEncryptionMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Description Indicates controller capability for automatic power saving. Value: 0 - Disabled, 1 Enabled, 99 - Undetermined Syntax Integer Access Read-only Table 1453. Controller Configured Drives SpinUp Time Name controllerConfiguredDrivesSpinUpTime Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.67 Description Indicates configured drives spin up start time. Value: 1:00 AM to 12:59 PM, 9999 Undetermined Syntax DisplayString Access Read-only Table 1454.
Table 1456. Channel Table Name channelTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.2 Description Defines the channel table. Syntax SEQUENCE OF ChannelEntry Access Not accessible Table 1457. Channel Entry Name channelEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1 Description Defines the channel table entry. Syntax ChannelEntry Access Not accessible Index channelNumber Table 1458. Channel Number Name channelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
2: Failed 3: Online 4: Offline - The I/O has paused. 6: Degraded Syntax Integer Access Read-only Table 1461. Channel Severity Name channelSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1462. Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1465. Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8 Description The status of the channel itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1466.
Table 1468. Channel Bus Type Name channelBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.11 Description The bus type of the channel. Possible values: 1: SCSI 2: IDE 3: Fibre Channel 4: Serial Storage Architecture (SSA) 6: Universal Serial Bus (USB) 7: SATA 8: SAS 9: PCIe Syntax Integer Access Read-only Enclosure Table This table describes available properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Table 1469.
Description Identifies the instance number of the enclosure entry. Syntax Integer Access Read-only Table 1472. Enclosure Name Name enclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.2 Description Identifies the enclosure's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1473. Enclosure Vendor Name enclosureVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.3 Description Identifies the enclosure's (re)seller's name.
Syntax Integer Access Read-only Table 1476. Enclosure ID Name enclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.6 Description Represents unique id for an enclosure. Syntax DisplayString Access Read-only Table 1477. Enclosure Processor Version Name enclosureProcessorVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1478.
Access Read-only Table 1481. Enclosure Split Bus Part Number Name enclosureSplitBusPartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.11 Description Identifies the enclosure's split bus part number. Syntax DisplayString Access Read-only Table 1482. Enclosure Product ID Name enclosureProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.12 Description Identifies the enclosure's product identification. This also corresponds to the enclosure type.
Access Read-only Table 1486. Enclosure Type Name enclosureType Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.16 Description Indicates the type of the enclosure. Possible values: 1: Internal 2: Dell PowerVault 200S (PowerVault 201S) 3: Dell PowerVault 210S (PowerVault 211S) 4: Dell PowerVault 220S (PowerVault 221S) 5: Dell PowerVault 660F 6: Dell PowerVault 224F 7: Dell PowerVault 660F/PowerVault 224F 8: Dell MD1000 9: Dell MD1120 Syntax DisplayString Access Read-only Table 1487.
Table 1489. Enclosure Channel Number Name enclosureChannelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.19 Description Identifies the channel number, or bus, to which the enclosure is connected. Syntax Integer Access Read-only Table 1490. Enclosure Alarm Name enclosureAlarm Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20 Description Identifies the current status of the enclosure's alarm (PowerVault 220S and PowerVault 221S only.
Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1494. Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24 Description The status of the enclosure itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1495.
Table 1497. Enclosure SCSI Rate Name enclosureSCSIRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.27 Description Actual SCSI rate in the enclosure. Syntax DisplayString Access Read-only Table 1498. Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28 Description The part number of the enclosure. Syntax DisplayString Access Read-only Table 1499. Enclosure Serial Number Name enclosureSerialNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.
Table 1502. Enclosure Total Slots Name enclosureTotalSlots Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.32 Description Shows the total number of physical slots in a storage enclosure; it includes total count of occupied and empty slots. NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-only Table 1503. Enclosure Empty Slot Count Name enclosureEmptySlotCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Table 1506. Array Disk Number Name arrayDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.1 Description Identifies the instance number of the array disk entry. Syntax Integer Access Read-only Table 1507. Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 Description Identifies the name of the array disk as represented in Storage Management. Syntax DisplayString Access Read-only Table 1508. Array Disk Vendor Name arrayDiskVendor Object ID 1.3.6.
24: Rebuild 25: No Media - CD-ROM or removable disk has no media. 26: Formatting - In the process of formatting. 28: Diagnostics - Diagnostics are running. 34: Predictive Failure 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers. 39: Foreign 40: Clear 41: Unsupported 53: Incompatible 56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached read-only state. Syntax Integer Access Read-only Table 1510.
Table 1513. Array Disk Revision Name arrayDiskRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.8 Description Identifies the firmware version of the array disk. Syntax DisplayString Access Read-only Table 1514. Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs. Syntax DisplayString Access Read-only Table 1515.
Table 1518. Array Disk Largest Contiguous Free Space in Megabytes Name arrayDiskLargestContiguousFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.13 Description The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte. Syntax Integer Access Read-only Table 1519. Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Access Read-only Table 1523. Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.18 Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte. This size plus the arrayDiskUsedSpaceInMB is the total amount of used space on the array disk. Syntax Integer Access Read-only Table 1524. Array Disk Free Space in Megabytes Name arrayDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.
8: SAS 9: PCIe Syntax Integer Access Read-only Table 1527. Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare. Possible states: 1: Disk is a member of a virtual disk 2: Disk is a member of a disk group 3: Disk is a global hot spare 4: Disk is a dedicated hot spare 5: Not a spare 99: Not applicable Syntax Integer Access Read-only Table 1528.
2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1530. Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.25 Description Identifies the operating system device name for this disk. Syntax DisplayString Access Read-only Table 1531. Array Disk Nexus ID Name arrayDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.26 Description Indicates the durable unique ID for this array disk.
Table 1534. Array Disk Negotiated Speed Name arrayDiskNegotiatedSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.29 Description Indicates the speed at which the drive is actually running in MPS (megabytes per second). Syntax Integer Access Read-only Table 1535. Array Disk Capable Speed Name arrayDiskCapableSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.30 Description Indicates the maximum speed at which the drive is capable of negotiating in MPS (megabytes per second).
Description Indicates the week (1 through 53) in which this disk was manufactured. Syntax DisplayString Access Read-only Table 1539. Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 Description Indicates the four digit year in which this disk was manufactured. Syntax DisplayString Access Read-only Table 1540. Array Disk Media Type Name arrayDiskMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Table 1543. Array Disk Alta Product Id Name arrayDiskAltaProductId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.38 Description Provides product ID for Alta interposer. Syntax Octet String Access Read-only Table 1544. Array Disk Alta Revision Id Name arrayDiskAltaRevisionId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.39 Description Provides revision ID for Alta interposer. Syntax Octet String Access Read-only Table 1545.
Access Read-only Table 1548. Array Disk Drive Write Cache Name arrayDiskDriveWriteCache Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.43 Description Indicates drive write cache capability for PCIe SSD devices. Value: 1 - Enabled, 0 Disabled, 99 - Undetermined/NotApplicable Syntax Integer Access Read-only Table 1549. Array Disk Model Number Name arrayDiskModelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.44 Description Provides PCIe SSD device model number.
-1: Not Available / Not Applicable 1: Drive Health Good 2: Approaching Warranty Coverage Expiry 3: Warranty Coverage Expired 4: Approaching Read Only 5: Read Only Syntax INTEGER Access Read-only Table 1553. Array Disk Read Only Name arrayDiskReadOnly Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.48 Description Provides the read only attribute for PCIe SSD. Possible Values: Yes, No, Not Applicable Syntax DisplayString Access Read-only Table 1554.
Syntax SEQUENCE OF ArrayDiskEnclosureConnectionEntry Access Not accessible Table 1556. Array Disk Enclosure Connection Entry Name arrayDiskEnclosureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1 Description Defines the array disk enclosure connection table entry. Syntax x Syntax ArrayDiskEnclosureConnectionEntry Access Not accessible Index x Index arrayDiskEnclosureConnectionNumber Table 1557.
Description Identifies the name of the enclosure as represented in Storage Management to which this array disk belongs. Syntax DisplayString Access Read-only Table 1561. Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.5 Description Identifies the instance number in the enclosureTable of the enclosure to which this array disk belongs. Syntax Integer Access Read-only Table 1562.
NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management. The following object sets up the Array Disk Channel Connection Table. Table 1564. Array Disk Channel Connection Table Name arrayDiskChannelConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.6 Description Defines the array disk channel connection table. Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Table 1565.
Fan Table This table describes available properties for each fan on the managed system. The following object sets up the Fan Table. Table 1573. Fan Table Name fanTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.7 Description Defines the fan table. Syntax SEQUENCE OF FanEntry Access Not accessible Table 1574. Fan Entry Name fanEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1 Description Defines the fan table entry. Syntax FanEntry Access Not accessible Index fanNumber Table 1575.
Description Identifies the fan's (re)seller's name. Syntax DisplayString Access Read-only Table 1578. Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 Description Identifies the current state of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing Syntax Integer Access Read-only Table 1579. Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.
Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1582. Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1583. Fan Probe Maximum Warning Name fanProbeMaximumWarning Object ID 1.3.6.1.
Table 1586. Fan1 Part Number Name fan1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12 Description Identifies the part number of the fan in the enclosure. Syntax DisplayString Access Read-only Table 1587. Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.13 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1588.
4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1590. Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for this fan. Syntax DisplayString Access Read-only Table 1591. Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 Description Indicates the revision number of the fan in the enclosure.
Access Not accessible Index fanConnectionNumber Table 1594. Fan Connection Number Name fanConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1 Description Identifies the instance number of the fan connection entry. Syntax Integer Access Read-only Table 1595. Fan Connection Fan Name Name fanConnectionFanName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.2 Description Identifies the name of the fan in this connection as represented in Storage Management.
Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs. Syntax Integer Access Read-only Power Supply Table Table 1599. Power Supply Table Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10892.1.600.12 Description Defines the Power Supply Table. Syntax PowerSupplyTableEntry Access Not accessible Table 1600. Power Supply Table Entry Name powerSupplyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.12.
Description Defines the capabilities of the power supply. Syntax DellPowerSupplyStateCapabilitiesUnique (Power Supply State Capabilities Unique) Access Read-only Table 1604. Power Supply State Settings Unique Name powerSupplyStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.4 Description Defines the state and settings of the power supply. Syntax DellPowerSupplyStateSettingsUnique (Power Supply State Settings Unique) Access Read-write Table 1605.
Access Read-only Table 1609. Power Supply Input Voltage Name powerSupplyInputVoltage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.9 Description Defines the input voltage to the power supply in volts. Syntax DellSigned32BitRange Access Read-only Table 1610. Power Supply Power Unit Index Reference Name powerSupplypowerUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.10 Description Defines the index to the associated system power unit in this chassis.
Table 1614. Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14 Description Defines the rated input wattage of the power supply (in tenths of Watts.) Syntax DellSigned32BitRange Access Read-only Power Supply Connection Table This table describes the connection between each power supply on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table.
Description Identifies the name of the power supply in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1619. Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.3 Description Identifies the instance number of the power supply in the powerSupplyTable in the connection. Syntax Integer Access Read-only Table 1620.
Temperature Probe Table Table 1623. Temperature Probe Table Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10892.1.700.20 Description Defines the Temperature Probe Table. Syntax TemperatureProbeTableEntry Access Not accessible Table 1624. Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.20.1 Description Defines the Temperature Probe Table entry.
Syntax DellStateCapabilities Access Read-only Table 1628. Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-write Table 1629. Temperature Probe Status Name temperatureProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.5 Description Defines the status of the temperature probe in tenths of degrees Celsius.
Syntax DellString Access Read-only Table 1633. Temperature Probe Upper Nonrecoverable Threshold Name temperatureProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.9 Description Defines the value of the temperature probe’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 1634. Temperature Probe Upper Critical Threshold Name temperatureProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Access Read-only Table 1638. Temperature Probe Lower Nonrecoverable Threshold Name temperatureProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.14 Description Defines the value of the temperature probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 1639. Temperature Probe Probe Capabilities Name temperatureProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Table 1642. Temperature Probe Connection Entry Name temperatureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1 Description Defines the temperature probe connection table entry. ber Syntax TemperatureConnectionEntry Access Not accessible Index temperatureConnectionNumber Table 1643. Temperature Probe Connection Number Name temperatureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.
Syntax DisplayString Access Read-only Table 1647. Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.5 Description Identifies the instance number of the enclosure in the enclosureTable to which this temperature probe belongs. Syntax Integer Access Read-only Enclosure Management Module Table This table describes available properties for each enclosure management module on the managed system.
Table 1651. Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.2 Description Identifies the enclosure management module's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1652. Enclosure Management Module Vendor Name enclosureManagementModuleVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.3 Description Identifies the enclosure management module's (re)seller's name.
Table 1655. Enclosure Management Module Part Number Name enclosureManagementModulePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.6 Description Identifies the part number of the enclosure memory module. Syntax Display String Access Read-only Table 1656. Enclosure Management Module Type Name enclosureManagementModuleType Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.7 Description Identifies the type of the enclosure management module.
Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1660. Enclosure Management Module Component Status Name enclosureManagementModuleComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.11 Description The status of the enclosure management module itself without the propagation of any contained component status.
Enclosure Management Module Connection Table This table describes the connection between each enclosure management module on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the enclosure Table. The following object sets up the Enclosure Management Module Connection Table. Table 1663. Enclosure Management Module Connection Table Name enclosureManagementModuleConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.
Table 1667. Enclosure Management Module Connection EMM Number Name enclosureManagementModuleConnectionEMMNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.3 Description Identifies the instance number in the enclosureManagementModuleTable of the enclosure memory module in this connection. Syntax Integer Access Read-only Table 1668. Enclosure Management Module Connection Enclosure Name Name enclosureManagementModuleConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.
Access Not accessible Index batteryChassisIndex , batteryIndex Table 1672. Battery Chassis Index Name batteryChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.1 Description Defines the index (one-based) of the chassis that contains the battery. Syntax DellObjectRange Access Read-only Table 1673. Battery Index Name batteryIndex Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.2 Description Defines the index (one-based) of the battery.
Table 1677. Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.6 Description Defines the reading of the battery. Syntax DellBatteryReading (Battery Reading) Access Read-only Table 1678. Battery Location Name Name batteryLocationName Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.7 Description Defines the location of the battery.
Description Identifies the instance number of the battery connection entry. Syntax Integer Access Read-only Table 1682. Battery Connection Battery Name Name batteryConnectionBatteryName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.2 Description Identifies the name of the battery in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1683. Battery Connection Battery Number Name batteryConnectionBatteryNumber Object ID 1.3.6.1.4.1.674.10893.
The following object sets up the Tape Drive Table. Table 1686. Tape Drive Table Name tapeDriveTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.17 Description A table of listed Tape Drives The number of entries is related to number of Tape Drives discovered in the system. The maximum number of entries is implementation dependent. NOTE: The properties in this table may not be applicable to all entries. Syntax SEQUENCE OF TapeDriveEntry Access Not accessible Table 1687.
Syntax DisplayString Access Read-only Table 1691. Tape Drive Product ID Name tapeDriveProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.4 Description The model number of the tape drive. Syntax DisplayString Access Read-only Table 1692. Tape Drive Nexus ID Name tapeDriveNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.5 Description Durable unique ID for this tape drive Syntax DisplayString Access Read-only Table 1693.
Syntax INTEGER Access Read-only Logical Devices Group The Logical Devices Management Information Base (MIB) group provides information about the logical devices managed by the Dell Storage Management Software and their relationships to each other.This group and all of its associated tables and objects are not supported on Microsoft Windows Advanced Server Limited Edition 64-bit operating system (Windows.Net-64) on a Dell PowerEdge 7150.
Syntax INTEGER Access Read-only Table 1699. Virtual Disk Name Name virtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.2 Description Identifies the virtual disk's label generated by Storage Management or entered by the user. Syntax DisplayString Access Read-only Table 1700. Virtual Device Disk Name Name virtualDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.3 Description Identifies the device name used by this virtual disk's member disks.
54: Degraded Redundancy Syntax INTEGER Access Read-only Table 1702. Virtual Disk Severity Name virtualDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax INTEGER Access Read-only Table 1703. Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Table 1706. Virtual Disk Free Space in Bytes Name virtualDiskFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.9 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1707. Virtual Disk Write Policy Name virtualDiskWritePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.10 Description Indicates whether the controller's write cache are used when writing to a virtual disk.
Table 1709. Virtual Disk Cache Policy Name virtualDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12 Description Indicates whether the controller's cache is used when reading from or writing to a virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not Applicable Syntax INTEGER Access Read-only Table 1710. Virtual Disk Layout Name virtualDiskLayout Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.13 Description Indicates the virtual disk's RAID type.
Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1714. Virtual Disk Target ID Name virtualDiskTargetID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.17 Description Unique ID for the virtual disk. Syntax INTEGER Access Read-only Table 1715. Virtual Disk LUN ID Name virtualDiskLunID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.18 Description This entry is obsolete.
Description The status of the virtual disk itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1718. Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21 Description Durable unique ID for this virtual disk. Syntax DisplayString Access Read-only Table 1719.
Table 1721. Virtual Disk Encrypted Name virtualDiskEncrypted Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.24 Description Indicates if virtual disk is encrypted. Value: 0 - No, 1 - Yes, 99 - Unknown Syntax INTEGER Access Read-only Table 1722. Virtual Disk is CacheCade Name virtualDiskIsCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.25 Description Indicates if this virtual disk is configured as CacheCade.
Description A table of managed virtual disk partitions. The number of entries is related to number of partitions discovered in the system. The maximum number of entries is implementation dependent. NOTE: The properties in this table may not be applicable to all entries. Syntax SEQUENCE OF VirtualDiskPartitionEntry Access Not-Accessible Table 1726. Virtual Disk Partition Entry Name virtualDiskPartitionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.
Access Read-only Table 1730. Virtual Disk Partition Size Name virtualDiskPartitionSize Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.4 Description Size of the partition in GB. Syntax INTEGER Access Read-only Table 1731. Virtual Disk Partition Fluid Cache Status Name virtualDiskPartitionFluidCacheStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.5 Description Indicates if the partition has associated fluid cache. Syntax OCTET STRING Access Read-only Table 1732.
Description An entry in the Fluid Cache table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax FluidCacheEntry Access Not-Accessible Table 1735. Fluid Cache Number Name fluidCacheNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.1 Description Instance number of this fluid cache entry. Syntax INTEGER Access Read-only Table 1736. Fluid Cache Name Name fluidCacheName Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.
Syntax OCTET STRING Access Read-only Table 1740. Fluid Cache License Duration Name fluidCacheLicenseDuration Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.6 Description Indicates the duration of the license validity. Syntax OCTET STRING Access Read-Only Table 1741. Fluid Cache License Capacity Name fluidCacheLicenseCapacity Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.7 Description Indicates the capacity of the license of fluid cache subsystem.
Table 1745. Fluid Cache License Product ID Name fluidCacheLicenseProductId Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.11 Description Indicates the product ID of the license of the fluid cache susbsytem. Syntax OCTET STRING Access Read-only Table 1746. Fluid Cache License Date Sold Name fluidCacheLicenseDateSold Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.12 Description Indicates the date on which the license for the fluid cache subsystem is sold.
Description Indicates the unique ID of the fluid cache component. Syntax OCTET STRING Access Read-only Fluid Cache Disk Table 1751. Fluid Cache Disk Table Name fluidCacheDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.5 Syntax SEQUENCE OF FluidCacheDiskEntry Access Not-Accessible Table 1752. Fluid Cache Disk Entry Name fluidCacheDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1 Syntax FluidCacheDiskEntry Access Not-Accessible Table 1753.
Access Read-only Table 1756. Fluid Cache Disk Backend Device Type Name fluidCacheDiskBackendDeviceType Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.4 Description This displays the type of the backend device beneath the fluid cache disk. Values are as below 773 denotes VirtualDisk 791 denotes Partition Syntax INTEGER Access Read-only Table 1757. Fluid Cache Disk Backend Device Name Name fluidCacheDiskBackendDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.
Description Configured Mode of the FluidCache. The values are : • • • 0 - Writeback mode 1 - Writethrough mode 2 - PassThrough mode Syntax INTEGER Access Read-Only Table 1761. Fluid Cache Disk Nexus Name fluidCacheDiskNexus Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.9 Description Durable Unique ID of the fluidcache disk. Syntax OCTET STRING Access Read-Write Table 1762. Fluid Cache Disk Status Name fluidCacheDiskStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.
Syntax FluidCachePoolEntry Access Not-Accessible Table 1765. Fluid Cache Pool Number Name fluidCacheDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.1 Description Instance number of the fluid cache pool entry. Syntax INTEGER Access Read-only Table 1766. Fluid Cache Pool Store Count Name fluidCachePoolStoreCount Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.2 Description Number of flash devices that are part of the fluid cache pool. Syntax INTEGER Access Read-only Table 1767.
Table 1770. Fluid Cache Pool High Availability State Name fluidCachePoolHighAvailabilityState Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.6 Description Indicates if the fluid cache pool is operating in high availability mode. Syntax OCTET STRING Access Read-Only Table 1771. Fluid Cache Pool Nexus Name fluidCachePoolNexus Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.7 Description Durable unique ID of the fluid cache pool entry. Syntax OCTET STRING Access Read-only Table 1772.
Access Not accessible Table 1774. Array Disk Logical Connection Entry Name arrayDiskLogicalConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1 Description Defines the array disk logical connection table entry. Syntax ArrayDiskLogicalConnectionEntry Access Not accessible Index arrayDiskLogicalConnectionNumber Table 1775. Array Disk Logical Connection Number Name arrayDiskLogicalConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.
Access Read-only Table 1779. Array Disk Logical Connection Virtual Disk Number Name arrayDiskLogicalConnectionVirtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.5 Description Identifies the instance number of the virtual disk to which this array disk belongs. Syntax Integer Access Read-only Table 1780. Array Disk Logical Connection Disk Name Name arrayDiskLogicalConnectionDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.
Table 1783. Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.2 Description Storage Management event message text describing the alert. Syntax DisplayString Access Read-only Table 1784. Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.3 Description Additional information identifying the location of the object causing the alert. Syntax DisplayString Access Read-only Table 1785.
Table 1788. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Current status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Table 1789. Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.8 Description Previous status of object causing the alert if applicable.
Change Management Group 24 The Change Management Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. NOTE: On systems running Linux, the optional srvadmin-cm RPM package must be installed for Dell OpenManage Server Administrator to respond to SNMP queries in this group. See the Server Administrator Installation Guide for more information.
Device Group Table The following object sets up the Device Group Table. Table 1793. Device Table Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table. Syntax SEQUENCE OF DeviceEntry Access Not accessible Table 1794. Device Entry Name deviceEntry Object ID 1.3.6.1.4.1.674.10899.1.5.1 Description Defines a device entry. Syntax DeviceEntry Access Not accessible Table 1795. Device Index Name deviceIndex Object ID 1.3.6.1.4.1.674.10899.1.5.1.
Table 1798. Device Vendor ID Name deviceVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.4 Description Defines the ID for the vendor supplying the device. Syntax Octet String Access Read-only Table 1799. Device ID Name deviceDeviceID Object ID 1.3.6.1.4.1.674.10899.1.5.1.5 Description Defines the ID for the device. Syntax Octet String Access Read-only Table 1800. Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.
Table 1802. Application Table Name applicationTable Object ID 1.3.6.1.4.1.674.10899.1.6 Description Defines a table of application information for the system. Syntax Defines a table of application information for the system. Access Not accessible Table 1803. Application Entry Name applicationEntry Object ID 1.3.6.1.4.1.674.10899.1.6.1 Description Defines an application entry. Syntax ApplicationEntry Access Read-only Table 1804. Application Index Name aplicationIndex Object ID 1.3.
Description Identifies the version of the application. Syntax DisplayString Access Read-only Table 1808. Application Display String Name aplicationDisplayString Object ID 1.3.6.1.4.1.674.10899.1.6.1.5 Description A user visible display string that describes the application. Syntax DisplayString Access Read-only Table 1809. Application Sub-Component ID Name applicationSubComponentID Object ID 1.3.6.1.4.1.674.10899.1.6.1.6 Description The sub-component ID for the application.
Dell Remote Access Controller Out-of-Band Group 25 The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB attributes provide product information for the chassis management controller: Table 1810. DRsProductName Name drsProductName Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Access Read-only Table 1814. DRsProductVersion Name drsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only Table 1815. DRsChassisServiceTag Name drsChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.6 Description Defines the Service Tag of the chassis. Syntax DellString Access Read-only Table 1816. DRsProductURL Name drsProductURL Object ID 1.3.6.1.4.1.674.10892.
Table 1819. DRsProductChassisName Name drsProductChassisName Object ID 1.3.6.1.4.1.674.10892.2.1.1.10 Description Defines the name of the chassis. Syntax DellString Access Read-only Table 1820. DRsSystemServiceTag Name drsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only Table 1821. DRsProductSystemAssetTag Name drsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Description Defines the data center locator of the chassis. Syntax DellString Access Read-only Table 1825. DRsProductChassisAisle Name drsProductChassisAisle Object ID 1.3.6.1.4.1.674.10892.2.1.1.16 Description Defines the aisle locator of the chassis. Syntax DellString Access Read-only Table 1826. DRsProductChassisRack Name drsProductChassisRack Object ID 1.3.6.1.4.1.674.10892.2.1.1.17 Description Defines the rack locator of the chassis.
Table 1830. DRsProductChassisSystemID Name drsProductChassisSystemID Object ID 1.3.6.1.4.1.674.10892.2.1.1.21 Description Defines the system ID of the chassis. Syntax INTEGER Access Read-only Table 1831. DRsFirmwareVersion Name drsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description Defines the firmware version of a chassis management controller 1. Syntax DellString Access Read-only Table 1832. DRsiKVMFirmwareVersion Name drsiKVMFirmwareVersion Object ID 1.3.6.1.4.1.
Table 1835. DRsGlobalCurrStatus Name drsGlobalCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.1 Description Defines the overall chassis status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1836. DRsIOMCurrStatus Name drsIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.2 Description Defines the IOM subsystem status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1837.
Table 1840. DRsFanCurrStatus Name drsFanCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.6 Description Defines the fan subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1841. DRsBladeCurrStatus Name drsBladeCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.7 Description Defines the blade subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1842.
Table 1845. DRsCMAmbientTemperature Name drsCMCAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.11 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis management card. Syntax DellTemperatureReading Access Read-only Table 1846. DRsCMProcessorTemperature Name drsCMCProcessorTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.12 Description Defines the temperature reading (in degrees Celsius) for the chassis management card processor.
Table 1850. DRsRedPrevStatus Name drsRedPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.4 Description Defines the previous redundancy status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 1851. DRsPowerPrevStatus Name drsPowerPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.5 Description Defines the previous power subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 1852.
Table 1855. DRsCMCPrevStatus Name drsCMCPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.9 Description Defines the CMC health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1856. DRsGlobalChangeTime Name drsGlobalChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.1 Description Defines the timestamp of the most recent global status change. Syntax TimeTicks Access Read-only Table 1857. DRsIOMChangeTime Name drsIOMChangeTime Object ID 1.
Description Defines the timestamp of the most recent power health status change. Syntax TimeTicks Access Read-only Table 1861. DRsFanChangeTime Name drsFanChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.6 Description Defines the timestamp of the most recent fan health status change. Syntax TimeTicks Access Read-only Table 1862. DRsBladeChangeTime Name drsBladeChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.
Description Defines the CMC power table. Syntax SEQUENCE OF DrsCMCPowerTableEntry Access Not-accessible Table 1866. DRsCMC Power Table Entry Name drsCMCPowerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.1.1 Description Defines the CMC power table entry. Syntax DrsCMCPowerTableEntry Access Not-accessible Table 1867. DRsCMC PSUTable Name drsCMCPSUTable Object ID 1.3.6.1.4.1.674.10892.2.4.2 Description Defines the CMC PSU table.
Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only Table 1871. DRsIdlePower Name drsIdlePower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3 Description Defines the power (in watts) required by the chassis infrastructure, along with the minimum power requirements for all systems currently turned on.
Syntax DellTimestamp Access Read-only Table 1876. DRsWattsPeakUsage Name drsWattsPeakUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.8 Description Defines the chassis peak power usage (in watts) since last reset. Syntax DellPowerReading Access Read-only Table 1877. DRsWattsPeakTime Name drsWattsPeakTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.9 Description Defines the timestamp of the most recent chassis peak power usage. Syntax DellTimestamp Access Read-only Table 1878.
Table 1881. DRsWattsReading Name drsWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13 Description Defines the instantaneous chassis power usage (in watts). Syntax DellPowerReading Access Read-only Table 1882. DRsAmpsReading Name drsAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14 Description Defines the instantaneous chassis current usage (in watts).
Table 1886. DRsPSUMonitoringCapable Name drsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.4 Description Defines the monitoring capabilities or the absence of a PSU in this location. Syntax DellCMCPSUCapable Access Read-only Table 1887. DRsPSUVoltsReading Name drsPSUVoltsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.5 Description Defines the instantaneous PSU voltage reading. Syntax DellPowerReading Access Read-only Table 1888.
Table 1891. DRsCMCServerTableEntry Name drsCMCServerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.5.1.1 Description Defines the CMC server table entry. Syntax DrsCMCServerTableEntry Access Not-Accessible CMC Server Information The following MIB tables provide CMC server information being monitored by the chassis management controller. Table 1892. DRsServerIndex Name drsServerIndex Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.
Access Read-only Table 1896. DRsServerSlotNumber Name drsServerSlotNumber Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.5 Description Defines the chassis slot number of the CMC server. Syntax DellString Access Read-only Chassis Alert The following MIB tables provide information on the chassis management controller alerts. Table 1897. DRsCASubSystem Name drsCASubSystem Object ID 1.3.6.1.4.1.674.10892.2.20.10.1 Description Defines the subsystem name of the CMC Alert.
Access Read-only Table 1901. DrsCAMessage Name drsCAMessage Object ID 1.3.6.1.4.1.674.10892.2.20.10.5 Description Defines the CSSD message of the CMC alert. Syntax DellString Access Read-only Chassis Alert 2 Table 1902. DRsCA2MessageID Name drsCA2MessageID Object ID 1.3.6.1.4.1.674.10892.2.21.10.1 Description Defines the message ID of the alert. Syntax DisplayString Access Read-only Table 1903. DrsCA2Message Name drsCA2Message Object ID 1.3.6.1.4.1.674.10892.2.21.10.
Table 1905. DrsCA2AlertStatus Name drsCA2AlertStatus Object ID 1.3.6.1.4.1.674.10892.2.21.10.4 Description Defines the status of the alert. Syntax DellStatus Access Read-only Table 1906. DrsCA2FQDD Name drsCA2FQDD Object ID 1.3.6.1.4.1.674.10892.2.21.10.5 Description Defines the fully qualified device descriptor of device causing the alert. Syntax DisplayString Access Read-only Legacy Alerting The following MIB tables provide information on the RAC legacy alerting. Table 1907.
Table 1910. DRsAlertCurrentStatus Name drsAlertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.4 Description Current status of object causing the alert. Syntax DellStatus Access Read-only Table 1911. DRsAlertPreviousStatus Name drsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5 Description Previous status of object causing the alert. Syntax DellStatus Access Read-only Table 1912. DRsAlertData Name drsAlertData Object ID 1.3.6.1.4.1.674.10892.2.5000.10.
26 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Table 1914. Table Index OID Variable Name alertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2 Description Specifies the object identifier for the index attribute in the table that contains the object causing the alert. Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object. Syntax OBJECT IDENTIFIER Table 1915. Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.1.5000.10.
Syntax DisplayString Table 1920. System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.4.5000.10.8 Description Specifies fully qualified domain name of the system generating the alert. Syntax DisplayString Table 1921. Service Tag Variable Name alertServiceTag Object ID 1.3.6.1.4.1.674.10892.4.5000.10.9 Description Specifies the system service tag of the system generating the alert. Syntax DisplayString Table 1922.
Description Line Item Explanation Chassis intrusion state: Specifies the chassis intrusion state (open or closed), for example: Chassis intrusion state: Open Chassis location: Specifies the name of the chassis that generated the message, for example: Chassis location: Main System Chassis Configuration error type: Specifies the type of configuration error that occurred, for example: Configuration error type: Revision mismatch Current s
Description Line Item Explanation Possible memory module event cause: Specifies a list of possible causes for the memory module event, for example: Possible memory module event cause: Single bit warning error rate exceeded Single bit error logging disabled Power Supply type: Specifies the type of power supply, for example: Power Supply type: VRM Pre-failure state was: Specifies the status of the previous memory message, for example: Pre-failure state wa
RAC Traps This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC). All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section Traps . The trap variables are sent in the order in which they are listed. NOTE: The PowerEdge M1000e CMC and PowerEdge VRTX CMC do not generate the traps in this section.
TrapID Name 1017 Description Severity Category Cause Supporte d by RAC Platform alertDrscSEL The RAC system Major 80 percentFull event log is 80% full Status RAC detected system event log is 80% full. All 1018 alertDrscSEL The RAC system Major 90 percentFull event log is 90% full Status RAC detected system event log is 90% full. All 1018 alertDrscSEL The RAC system Major 90 percentFull event log is 90% full Status RAC detected system event log is 90% full.
drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag and drsGlobalCurrStatus. The trap variables are defined in the Dell Remote Access Controller Out-of-Band Group section. System Trap Group The System Trap Group contains traps that fall under the System event category. Table 1926. Amperage Probe Traps TrapID Description Category SubCategory Severity Current sensor reading is within Status Events range.
Table 1929. CMC Traps TrapID Description Category SubCategory Severity Chassis Management Controller detected a warning. Status Events CMC Minor Chassis Management Controller detected an error. Error Events CMC Critical Description Category SubCategory Severity Fan information. Status Events Fan Informational Fan warning. Status Events Fan Minor Fan failure.
Table 1933. Link Status Traps TrapID Description Category SubCategory Severity Link status information. Status Events Link Status Informational Link status failure or critical event. Error Events Link Status Critical Description Category SubCategory Severity Power supply has returned to normal. Status Events Power Supply Informational Power supply has detected a warning. Status Events Power Supply Minor Power supply has detected a failure.
Table 1937. Security Event Traps TrapID Description Category SubCategory Severity Security information. Status Events Security Informational Security failure or critical event. Error Events Security Critical Category SubCategory Severity Status Events System Event Log Informational System Event Log warning. Status Events System Event Log Minor System Event Log failure or critical event.
Table 1941. Voltage Probe Traps TrapID Description Category SubCategory Severity Voltage sensor reading is within range. Status Events Voltage Informational Voltage sensor has detected a warning value. Status Events Voltage Minor Voltage sensor has detected a failure value. Error Events Voltage Critical Category Subcategory Severity Storage battery information. Error Events Battery Informational Storage battery warning. Error Events Battery Minor Storage battery failure.
TrapID Description Category Subcategory Severity Storage enclosure warning. Error Events Enclosure Minor Storage enclosure failure. Error Events Enclosure Critical Description Category Subcategory Severity Storage fan information. Error Events Fan Informational Storage fan warning. Status Events Fan Minor Storage fan failure. Error Events Fan Critical alert2StorageEnclosureWarning 4338 alert2StorageEnclosureFailure 4337 Table 1945.
Table 1948. Storage Management Status Traps TrapID Description Category Subcategory Severity Error Events Storage Management Informational Storage Management has Error Events detected a device independent warning condition. There is no global status change associated with this trap.
TrapID Description Category Subcategory Severity 4353 Storage Virtual disk failure. Error Events Virtual Disk Critical Audit Traps The Audit Trap group contains traps that fall under the Audit event category. Table 1951. Audit CMC Traps TrapID Description Category SubCategory Severity Chassis Management Controller audit information. Status Events CMC Informational Chassis Management Controller audit warning.
Table 1954. Configuration IO Virtualization Traps TrapID Description Category SubCategory Severity Status Events IO Virtualization Informational Description Category SubCategory Severity Test trap generated by CMC in response to a user request. Status Events Test Informational alert2IOVConfigurationInformation 10747 IO virtualization configuration information. Table 1955.
TrapID Description Severity 131328 Under-Voltage Warning (Lower Non Critical - going low) Warning 131456 Under-Voltage Warning Cleared Information 131330 Under-Voltage Problem (Lower Critical - going low) Critical 131458 Under-Voltage Problem Cleared Information 131335 Over-Voltage Warning (Upper Non Critical - going high) Warning 131463 Over-Voltage Warning Cleared Information 131337 Over-Voltage Problem (Upper Critical - going high) Critical 131465 Over-Voltage Problem Cleared In
TrapID Description Severity 487297 CPU Thermal Trip (Over Temperature Shutdown) Cleared Information 487168 CPU Internal Error Critical 487296 CPU Information Internal Error Cleared 487173 CPU Configuration Error Critical 487301 CPU Configuration Error Cleared Information 487175 CPU Presence (Processor Presence detected) Information 487303 CPU Not Present (Processor Not Present) Critical 487170 CPU BIST (Built In Self Test) Failure Critical 487298 CPU BIST (Built In Self Test) Failure
TrapID Description Severity 1076996 System Event Log (SEL) Full (Logging Disabled) Critical 2322176 ASR (Automatic System Recovery) Timer Expired Critical 2322177 ASR (Automatic System Recovery) Reset Occurred Critical 2322178 ASR (Automatic System Recovery) Power Down Occurred Critical 2322179 ASR (Automatic System Recovery) Power Cycle Occurred Critical 531
Storage Management Alert Reference 27 Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up. If you stop the Disk Management Service, then alert monitoring and logging stops.
Table 1956. Storage Management Alert Severity Alert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation. Warning/Non-critical A component requires attention. This alert indicates a potential problem, but does not necessarily mean that the system has currently lost data or is nonfunctional.
Trap Variables The Storage Management SNMP traps use a set of variables that are included with every trap. Below mentioned variables are the Traditional Varbinds: Table 1957. Message ID Event Name messageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.1 Description Storage Management alert (event) message number. Syntax INTEGER Access Read-only Table 1958. Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
Syntax DisplayString Access Read-only Table 1962. Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Table 1963. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Current status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Table 1964.
Description Hostname of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 1967. Enhanced Service Tag Event Name serviceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.11 Description Service Tag of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 1968. Enhanced Chassis Service Tag Event Name chassisServiceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
iDRAC7 MIB 28 The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 7 (iDRAC7). This MIB provides management data that allows you to monitor devices and software on a system via an out-of-band connection to the iDRAC7 of a system. NOTE: As of iDRAC7 firmware release r1.30.30 (which corresponds to the release of Dell OpenManage Server Administrator Version 7.
SNMP Operations Supported SNMP version GET, GETNEXT, GETBULK SNMP v1 , v2c and v3 TRAP SNMP v1 and SNMP v2c NOTE: iDRAC7 does not support the SNMP SET operation for any data NOTE: As of iDRAC7 firmware release r1.30.30, iDRAC7 supports SNMP query operations (GET, GETNEXT, GETBULK) via the SNMPv3 protocol, in addition to supporting query operations via the SNMP v1 and SNMP v2c protocols. More specifically, iDRAC7 now supports the SNMP User Security Model (USM).
Description This attribute defines the product name of a remote access card. Syntax StringType Access Read-only Table 1970. RAC Name Name racShortName Object ID 1.3.6.1.4.1.674.10892.5.1.1.2.0 Description This attribute defines the short product name of a remote access card. Syntax StringType Access Read-only Table 1971. RAC Description Name racDescription Object ID 1.3.6.1.4.1.674.10892.5.1.1.3.0 Description This attribute defines the product description of a remote access card.
Table 1975. RAC Type Name racType Object ID 1.3.6.1.4.1.674.10892.5.1.1.7.0 Description This attribute defines the type of a remote access card. Syntax RacTypeEnum Access Read-only Table 1976. RAC Firmware Version Name racFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.8.0 Description This attribute defines the firmware version of a remote access card.
Description This attribute defines the service tag of the system. Syntax StringType Access Read-only Table 1980. System Express Service Code Name systemExpressServiceCode Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. Syntax StringType Access Read-only Table 1981. System Asset Tag Name systemAssetTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0 Description. This attribute defines the asset tag of the system.
Table 1985. System Data Center Name Name systemDataCenterName Object ID 1.3.6.1.4.1.674.10892.5.1.3.8.0 Description This attribute defines the Data Center locator of the system. Syntax StringType Access Read-only Table 1986. System Aisle Name Name systemAisleName Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.0 Description This attribute defines the Aisle locator of the system. Syntax StringType Access Read-only Table 1987. System Rack Name Name systemRackName Object ID 1.3.6.1.4.1.674.
Description This attribute defines the system ID of the system. Syntax Unsigned16BitRange Access Read-only Table 1991. System OS Version Name systemOSVersion Object ID 1.3.6.1.4.1.674.10892.5.1.3.14.0 Description This attribute defines the version of the operating system that the host is running. Syntax StringType Access Read-only Table 1992. System Room Name Name systemRoomName Object ID 1.3.6.1.4.1.674.10892.5.1.3.15.
Table 1995. Global System Status Name globalSystemStatus Object ID 1.3.6.1.4.1.674.10892.5.2.1.0 Description This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only Table 1996. System LCD Status Name systemLCDStatus Object ID 1.3.6.1.4.1.674.10892.5.2.2.0 Description This attribute defines the system status as it is reflected by the LCD front panel.
NOTE: See the iDRAC7 MIB file for details of the tables supported under the Storage Details Group. iDRAC7 Traps The iDRAC7 generates events that result in Simple Network Management Protocol (SNMP) traps and/or entries in the iDRAC7 Lifecycle Log. This section describes the traps, also known as alerts, generated by the iDRAC7. The iDRAC7 generates events in response to changes in the status of sensors and other monitored parameters.
Syntax StringType Table 2001. Alert Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.5.3.1.3.0 Description Current status of object causing the alert, if applicable. Syntax ObjectStatusEnum Access Read-only Table 2002. Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.4.0 Description Service tag of the system. Syntax DisplayString (SIZE (0..16)) Table 2003.
the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes. Syntax StringType Table 2007. Alert Chassis Service Tag Variable Name alertChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.5.3.1.9.0 Description For blade systems, the service tag of the enclosing chassis. For rack and tower systems, this varbind will be empty (zero length). Syntax DisplayString (SIZE (0..
TrapID Description Category SubCategory Severity Battery is low. System Health Battery Event Minor Battery has failed or battery is absent. System Health Battery Event Critical Category SubCategory Severity System Health Processor Informational Processor device status has detected a warning. System Health Processor Minor Processor device status has detected a failure. System Health Processor Critical Description Category SubCategory Severity Processor device is absent.
TrapID Description Category SubCategory Severity Fiber Channel warning. System Health Fiber Channel Minor Fiber Channel failure or critical event. System Health Fiber Channel Critical Category SubCategory Severity System Health Hardware Config Informational System Health Hardware Config Minor System Health Hardware Config Critical Description Category SubCategory Severity Memory device informational event.
TrapID Description Category SubCategory Severity 2089 Network failure or critical event. System Health NIC Config Critical SubCategory Severity An OS graceful stop occurred; or System Health an OS graceful shut-down occurred. OS Event Informational A critical stop occurred during OS load; or a runtime critical stop occurred. System Health OS Event Critical Description Category SubCategory Severity An informational event was detected for a PCI device.
Table 2021. BIOS POST Trap TrapID Description Category SubCategory Severity System BIOS detected a failure. System Health BIOS POST Critical Description Category SubCategory Severity Power supply has returned to normal. System Health Power Supply Informational Power supply has detected a warning. System Health Power Supply Minor Power supply has detected a failure. System Health Power Supply Critical Description Category SubCategory Severity Power supply is absent.
Table 2025. Redundancy Traps TrapID Description Category SubCategory Severity Redundancy information. System Health Redundancy Informational Redundancy is degraded. System Health Redundancy Minor Redundancy is lost.
TrapID Description Category SubCategory Severity 2489 Integrated Dual SD Module redundancy is lost. System Health IDSDM Redundancy Critical Description Category SubCategory Severity Security information. System Health Security Event Informational Security failure or critical event. System Health Security Event Critical Table 2029. Security Event Traps TrapID Security Information 2387 Security Failure 2385 Table 2030.
TrapID Description Category SubCategory Severity Temperature Statistics Critical Category SubCategory Severity vFlash Media device information. System Health vFlash Event Informational vFlash Media device warning. System Health vFlash Event Minor vFlash Media device failure. System Health vFlash Event Critical Description Category SubCategory Severity vFlash Media device is absent.
Storage Trap Group The Storage Trap Group contains traps that fall under the Storage event category of iDRAC7. Storage traps are traps generated in response to events related to the external storage subsystem of the system in which iDRAC7 resides. Table 2036. Battery Traps TrapID Description Category SubCategory Severity Battery state has returned to normal; or battery presence has been detected. Storage Battery Event Informational Battery is low.
TrapID Description Category SubCategory Severity 4202 Fan warning. Storage Fan Event Minor Fan failure. Storage Fan Event Critical Description Category SubCategory Severity Storage Physical Disk Informational Physical disk warning. Storage Physical Disk Minor Physical disk failure. Storage Physical Disk Critical Description Category SubCategory Severity Storage Power Supply Informational Power supply warning. Storage Power Supply Minor Power supply failure.
Table 2043. Temperature Probe Traps TrapID Description Category SubCategory Severity Storage Temperature Informational Storage Temperature Minor Temperature probe failure. Storage Temperature Critical Description Category SubCategory Severity Virtual disk information. Storage Virtual Disk Informational Virtual disk warning. Storage Virtual Disk Minor Virtual disk failure. Storage Virtual Disk Critical Storage Temperature Probe Information 4211 Temperature probe information.
Table 2046. iDRAC IP Address Change Trap TrapID Description Category SubCategory Severity iDRAC IP address has changed. Audit DRAC IP Address Informational Description Category SubCategory Severity License information. Audit Licensing Informational License warning. Audit Licensing Minor License failure. Audit Licensing Critical Category SubCategory Severity Audit System Info Informational iDRAC IP Address Change 8499 Table 2047.
Standard Data Type Definitions 29 This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib , dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
unknownCapabilities(1) The object’s capabilities are unknown. enableCapable(2) The object can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The object is not ready. enableAndNotReadyCapable (6) Enable and not ready capable. Table 2051. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled.
ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical. critical(5) The object’s status is critical (failure). nonRecoverable(6) The object’s status is nonrecoverable (dead). Table 2054. Dell Status Redundancy Variable Name: DellStatusRedundancy Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s redundancy status is unknown. full(3) The object is fully redundant.
The DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information sent back by this subagent has the most significant byte of the information as the first byte. For example, the hex address 0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ... Byte 1 Byte 2 Byte 3 Byte 4. Full Dates Variable Name: DellDateName Data Type: DisplayString DisplayString (SIZE (25)) Full dates are defined in the ASCII format: yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.
SNMP Sample Output 30 This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB).
'\02\02\02\02\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.25.1 = '\03\03\03\03\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.26.1 = '\02\02\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.28.1 = '\03\03\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.42.1 = 3 1.3.6.1.4.1.674.
1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.4.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.5.1.1 cleared' 1.3.6.1.4.1.674.10892.1.300.40.1.6.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.7.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.8.1.1 '20050513100047.