Release Notes

During systems management software installation on managed systems or management stations, if the
Prerequisite checker displays a blank Internet Explorer screen, the probable cause is a corrupted Internet
Explorer installation. In such cases, browsing to any site displays the message: The requested lookup
key was not found in any active activation context.
Resolution: Ensure that you install Internet Explorer correctly before installing your systems
management software.
Issue 5:
Description: MSI reference counts affected for Intel SNMP agent install.
MSI reference counting takes effect if you install the Intel SNMP agent using the MSI provided by Intel,
and then installs the Intel SNMP agent again using the Server Administrator installer.
Resolution: The Intel SNMP agent is not uninstalled during installation of the MSI; you must remove both
installers from the system to remove the agent.
Known Issues on Linux
Issue 1:
Description: SBUU modifies .bash_profile. (152668)
Systems Build and Update Utility adds a script to the .bash_profile file of the root user that prompts the
installation of systems management software. This script may interfere with remote client applications
that authenticate using the root user account on the system, but cannot handle user prompts.
Resolution: To fix this, edit the .bash_profile file and comment the line: "[ ${SHLVL}...."
Versions Affected: 7.4 and earlier
Issue 2:
Description: Dependency issue during install. (303464)
During an installation, if the libstdc++.so.5 is needed by srvadmin-<
component
> fails, dependency
error is displayed.
Resolution: Install the compatibility libraries from the Linux distribution. To install a compatibility library,
use the following command: rpm -ivh compat-libstdc++*.rpm
Versions Affected: 7.4.1 and earlier
Issue 6:
Description: Unable to upgrade Server Instrumentation in Interactive mode when older Server
Instrumentation is installed from the custom folders. (062800) (062355)
The installation of Server Instrumentation will not be successful, if you have earlier, initially installed
Server Instrumentation using the custom folder and later try to upgrade it manually.
Resolution:
It is recommended that you avoid mixing install methods. Mixing install methods will
cause loss of functionality and the upgrade will be unsuccessful. For example, if you have