Server Administrator 7.4.
Release Type and Definition Server Administrator This document contains updated information for the "Server Administrator User's Guide" and any other technical documentation included with Server Administrator. NOTE: System Management software, including the Server Administrator (Server Administrator), is available only on the "Systems Management Tools and Documentation" DVD.
Software Requirements • Supported operating system and web browser. • TCP/IP connection on the managed system and the remote system to facilitate remote system management. • Supported systems management protocol standard. For more information, see "Supported Systems Management Protocol Standards". • The Server Administrator Remote Access Controller service requires remote access controller (RAC) to be installed on the managed system.
• Support for displaying and setting the JRE version. See Secure Port System. • Support for displaying Node Id in System/Server Module Summary information. See Server Administrator Command Line Interface Guide or online help. • Support for new values for form factor aligning to iDRAC values. See Server Administrator Command Line Interface Guide or online help. • Added support for Software RAID controllers (PERC S110) on systems running the Windows Server 2012 R2 operating system.
Fixes The following problems were reported in earlier releases of Server Administrator and have been corrected in this release: • BITS032251: OME show "The task was cancelled for the target device" with stopped execution state during OMSAPush • BITS040212: Migrated DF489665 Max Config: OM on ESXi 4.
• BITS083254: OMSA deploy fails on SLES10 SP4 and SLES11 system • BITS083480: Attempt to install OMSA using MSP task pass when target does not have OMSA installed • BITS083854: Disk Cache Policy setting in create VD via advanced wizard coming Enabled by default for SAS Drives BITS088267: OM 7.2 displays HDD manufacture name instead of Dell immediately after startup Important Notes Notes for Server Administrator On 12G systems with iDRAC7 1.30.
• CMC USB ports attached with blade is not enumerated by Server Administrator. • Except for AC power cord traps, SNMP traps for server instrumentation are not generated when the state of the device sensor changes from unknown to normal. While migrating the chassis of a PowerEdge M520, M620, or M820 server running Windows operating system from M1000e to VRTX chassis, reboot the server after the new drivers are detected and installed.
• BITS072069: On ESX/ESXi Operating Systems, Server Administrator configuration changes are not persisted after an unclean shutdown. o If the server abruptly reboots, configuration changes to Server Administrator Preferences are not retained on VMware ESX or ESXi operating systems. Once an hour, VMware runs a scheduled backup to update any configuration changes to the installed applications (VIBs). For more information, refer to the Knowledge Base article at - http://Kb.vmware.
• After a "Reset to Defaults" operation of the Integrated Remote Access Controller, the first user configuration operation fails if it is a single-user configuration item (such as enabling or disabling a user or changing user name). Always change a combination of two-user configuration items (such as enabling or disabling a user and changing user name) concurrently during your first configuration operation.
• All unsecured HTTP requests to Server Administrator receive an invalid response. Server Administrator runs only one instance of the Web server, which is secure. Make all connections through https:// : . Any "http://: " request for connection with the server receives an invalid response. • If the browser used with Server Administrator does not display a page or perform an action, make sure that the browser is in online mode.
Administrator reports the two platform event filters related to power monitoring as "System Power Probe Warning" and "System Power Probe Failure". These two filters are not supported on these systems. That is, you can view and configure these filters, but no action is taken. • DF185770: Primary User Telephone Number does not accept symbols. On Server Administrator, under Asset Information->System Information->Primary User Telephone Number configuration allows only alphanumeric characters.
• BITS04016: In case of Boot/HDD/UEFI sequence, if they are read-only, then toggle buttons (+ and -) and submit button are not visible. On BIOS setup page, dependencies may exist between the various attributes for Bios settings. Setting an attribute value may change the state of the dependent attributes to non-editable or editable. For example, changing the Boot Mode to UEFI from the Boot Settings page does not allow you to configure the Boot or Hard-Disk Drive Sequence in the BIOS Boot Settings page.
• The DSM Server Administrator Connection Service may hang on system startup if both Oracle and VERITAS Backup Exec are installed on the system. To manually start the DSM Server Administrator Connection Service on a system running Windows, click "Start-> Programs-> Administrative Tools-> Service", right-click "DSM Server Administrator Connections Services" and select "Start".
o • "http://support.microsoft.com/default.aspx?scid=kb;en-us;317541" There are two options to avoid these errors from being written to the Event log: o Uninstall the "Update Root certificates" component as described in the first knowledge base article mentioned above. NOTE: This procedure may affect other programs as discussed in the article. o Install the Server Administrator certificate as a trusted certificate.
the Service Control Manager logs the following message to the System log: "The DSM Server Administrator Data Manager Service is marked as an interactive service. However, the system is configured to not allow interactive services. This service may not function properly." This change allows the DSM Server Administrator Data Manager Service to execute interactive applications properly for an Alert Action.
"omconfig rac authentication" • Due to fluctuations in the watchdog timer, the "Last Crash Screen" may not be captured when the Automatic System Recovery is set to a value of less than 30 seconds. To ensure correct functioning of the "Last Crash Screen" feature, set the System Reset Timer to at least 30 seconds. • DF132894: The cfgDNSServer1 and cfgDNSServer2 properties of group cfgLanNetworking may be set to identical values while swapping addresses.
-i " where is the index of the user database entry to be modified and is the new password. • Depending on your network and proxy configurations and whether you are using Mozilla browser, you may need to enter the exact IP address of the RAC controller you are trying to access in the "No Proxy for" field of your browser. Perform the following steps: 1. Open your Mozilla browser. 2. Click "Edit". 3. Click "Preferences". 4. Click "Advanced" in the left sidebar. 5.
recorded is reached, the existing oldest logs are overwritten. But for 11G servers or below, when the maximum limit is reached, the information logging is stopped. • DF523827: On Citrix XenServer 6.0, if the Alert on Console alert action is configured from the Server Administrator CLI or GUI, the alert message may not be displayed in a readable format. • DF530134: On VMware ESX 4.
3. Configure NetDMA to disable state by running following command: netsh int tcp set global NetDMA=disabled Limitations Known Limitations and Workarounds for Storage Management Service • With Chinese or Japanese language browser settings, using the Storage Management Service Advanced Create VDisk Wizard may occasionally result in text overflowing to the bottom of the side-by-side blue text boxes. • View slot occupancy report shows 4 HDD slots on backplanes with just two HDD slots for any server.
• Hot plug of enclosures takes time to enumerate the enclosure and its components. During this time, there will be a delay in the response time of tasks, such as displaying the physical disks on the physical disk page and in the virtual disk selection page. • All virtual disks from the SAS/iR controller display the name "IR Virtual Disk" on the "Preview" page. On successful import, another name is assigned to these virtual disks and the "IR Virtual Disk" name is not displayed on the "Preview" page.
• When issuing certain "omconfig storage" CLI commands with "Power User" privileges, the "Error! User has insufficient privileges to run command: omconfig" message may be displayed. You must be logged on as an Administrator to perform these actions. • Using the Storage Management Service "Advanced Create VDisk Wizard" may occasionally result in a vertical scrollbar of less than normal width. If this occurs, resizing the Server Administrator window causes the vertical scrollbar to be redrawn correctly.
system meets the firmware requirement or not, by checking the application log files for notifications on outdated firmware. At runtime, On SCSI controllers, Storage Management displays the firmware version at runtime while on SAS controllers it displays the firmware and driver versions. Installation Procedure For complete installation instructions, see the "Server Administrator Installation Guide".
• "The Web server on 1311 allows scripts to read sensitive configuration and / or XML files." • "The Web server on 1311 allows to delete "/" which implies that the Webserver will allow a remote user to delete the files in root on the server." • "The web server on 1311 may be susceptible to a 'www Infinite Request' attack." • "It is possible to make the remote thttpd server execute arbitrary code by sending a request like: GET If-Modified-Since:AAA[...
Controller Firmware/BIOS PERC 5/E 5.2.2-0076 PERC 5/i Integrated 5.2.3-0074 PERC 5/i Adapter 5.2.3-0074 SAS 5/iR Integrated 00.10.51.00/ 06.12.05.00 SAS 5/iR Adapter 00.10.51.00/ 06.12.05.00 SAS 5/i Integrated 00.10.51.00/ 06.12.05.00 SAS 5/E Adapter 00.10.51.00/ 06.12.05.00 PERC 6/E Adapter 6.3.1-0003 PERC 6/i Integrated 6.3.1-0003 PERC 6/i Adapter 6.3.1-0003 SAS 6/iR Integrated 00.25.47.00 06.22.03.00 SAS 6/iR Adapter 00.25.47.00 06.22.03.00 SAS 6/int. Modular 00.25.47.00 06.22.
PERC H730 Adaptor 25.2.1.0011 PERC H730 Mini 25.2.1.0011 Blades 25.2.1.0011 PERC H730 Mini 25.2.1.0011 PERC H830 Adaptor 25.2.1.0011 PERC H330 Adaptor 25.2.1.0008 PERC H330 Mini 25.2.1.0008 PERC H330 Mini Blades 25.2.1.0008 PERC H330 Embedded 25.2.1.
LSI 1030 on a PowerEdge 1750 Not Applicable Not Applicable Not Applicable Not Applicable PERC H800 Adapter 4.31.1.32 4.31.1.64 4.31.1.64 Native PERC H700 Integrated 4.31.1.32 4.31.1.64 4.31.1.64 Native PERC H700 Adapter 4.31.1.32 4.31.1.64 4.31.1.64 Native PERC H700 Modular 4.31.1.32 4.31.1.64 4.31.1.64 Native PERC H200 Adapter 2.0.35.10 2.0.35.10 2.0.35.10 Native PERC H200 Integrated 2.0.35.10 2.0.35.10 2.0.35.10 Native PERC H200 Modular 2.0.35.10 2.0.35.10 2.0.35.
PERC H730 Mini Blades 6.601.00.00 6.601.00.00 6.601.00.00 6.601.00.00 PERC H730 Mini Monolithic 6.601.00.00 6.601.00.00 6.601.00.00 6.601.00.00 PERC H830 Adaptor 6.601.00.00 6.601.00.00 6.601.00.00 6.601.00.00 PERC H330Adaptor 6.601.00.00 6.601.00.00 6.601.00.00 6.601.00.00 PERC H330 Mini Monolithic 6.601.00.00 6.601.00.00 6.601.00.00 6.601.00.00 PERC H330 Mini Blades 6.601.00.00 6.601.00.00 6.601.00.00 6.601.00.00 PERC H330 Embedded 6.601.00.00 6.601.00.00 6.601.00.00 6.
Modular LSI 1020 on 1600SC Native Native Native LSI 1030 on Power Edge 1750 Native Native Native PERC H800 Adapter Native Native Native PERC H700 Integrated Native Native Native PERC H700 Adapter Native Native Native PERC H700 Modular Native Native Native PERC H200 Adapter Native Native Native PERC H200 Integrated Native Native Native PERC H200 Modular Native Native Native 6Gbps SAS HBA Native 5.2.220.
Adapter PERC H730P Mini Blades Native Native Native PERC H730P Native Native Native Native Native Native Native Native Native Native Native Native Native Native Native Native Native Native PERC H330 Mini Blades Native Native Native PERC H330 Native Native Native Native Native Native Mini Monolithic PERC H730 Adapter PERC H730 Mini Blades PERC H730 Mini Monolithic PERC H830 Adapter PERC H330 Adapter Mini Monolithic PERC H330 Embedded Installation and Configuration Notes N
Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws. Dell™ and the Dell logo are trademarks of Dell Inc. in the United States and/or other jurisdictions. All other marks and names mentioned herein may be trademarks of their respective companies.