Command Line Interface Guide

Index
Source
At present, source=snmptraps is a required name=value pair because SNMP is currently the only
supported source of event notification for the system’s components.
omconfig system events source=snmptraps
or
omconfig servermodule events source=snmptraps
Type
Type refers to the name of the component(s) involved in the event. The following table displays the valid
parameters for system event types.
Table 44. System Event Type Parameters
name=value pair Description
type=accords Configures events for AC power cords.
type=battery Configures events for battery.
type=all Configures events for all device types.
type=fanenclosures Configures events for fan enclosures.
type=fans Configures events for fans.
type=intrusion Configures events for chassis intrusion.
type=log Configures events for logs.
type=memory Configures events for memory.
type=powersupplies Configures events for power supplies.
type=redundancy Configures events for redundancy.
type=systempower Configures events for system power.
type=temps Configures events for temperatures.
type=volts Configures events for voltages.
type=systempeakpower Configures events for system peak power.
type=removableflashme
dia
Configures events for removable flash media.
Severity
In the context of configuring events, severity determines how severe an event is, before Server
Administrator notifies you of the event for a component type. When there are multiple components of
the same type in the same system chassis, you can specify whether you want notification for event
severity according to the number of the component by using the index=<n> parameter. The following
table displays the valid severity parameters.
111