Reference Guide

Field Description
Cache Device Supported
Type
Type of static random access memory (SRAM) that the device can
support.
Cache Device Current Type Type of the currently installed SRAM that the cache is supporting.
External Socket Name Silk
Screen Name
Name printed on the system board next to the socket.
Error Correction Type Identifies the type of error checking and correction (ECC) that this
memory can perform. Examples are correctable ECC or uncorrectable
ECC.
Omreport Chassis Pwrmanagement Or Omreport Mainsystem
Pwrmanagement
Use the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement command to view
the power budget cap and power management profiles of the system. The values display either in Watts
or BTU/Hr based on the configuration. Type:
omreport chassis pwrmanagement
or
omreport mainsystem pwrmanagement
NOTE: To maintain consistency across the commands, the output format of this command and the
subsequent command levels has changed. So, you may have to change the user scripts as
applicable.
NOTE: The omreport chassis pwrmanagement or omreport mainsystem pwrmanagement
command is applicable on PowerEdge 11G systems that support Power Management Bus (PMBus)
and that have hot-swappable power supplies and not systems that have a fixed, non-redundant
power supply installed.
The output of the omreport chassis pwrmanagement or omreport mainsystem pwrmanagement
command lists each of the valid parameters. The following table lists the available settings.
Table 11. Valid Parameters Of Omreport Chassis Pwrmanagement Or Omreport Mainsystem
Pwrmanagement
name=value pair Description
unit=<watt | btuphr>
Displays power in the user-specified units.
config=budget
Displays power budget information.
config=profile
Displays power profiles information.
NOTE: On PowerEdge 12G systems, profile
option is SysProfile and is grouped under
System Profile Settings of the BIOS setup
group. For more information, see BIOS Setup
Settings on PowerEdge 12G systems.
39