Reference Guide

example, the probe that is being configured is probe 0. The first command sets only the minimum
threshold; the second sets the minimum and maximum thresholds:
omconfig chassis fans index=0 minwarnthresh=4580
or
omconfig mainsystem fans index=0 minwarnthresh=4580
omconfig chassis fans index=0 minwarnthresh=4580 maxwarnthresh=9160
or
omconfig mainsystem fans index=0 minwarnthresh=4580 maxwarnthresh=9160
When you issue the command and the system sets the values you specify, the following message is
displayed:
Fan probe warning threshold(s) set successfully.
NOTE: You cannot set the minimum and maximum warning thresholds for the fan probe on
PowerEdge 9G system.
Omconfig Chassis Frontpanel Or Omconfig Mainsystem Frontpanel
Use the omconfig chassis frontpanel or omconfig mainsystem frontpanel command to:
configure the power button and the Nonmasking Interrupt (NMI) button
configure the LCD to display:
No information
Custom information
Default system information
Service tag, system name
Remote access MAC addresses
System power
Remote access IP address
Ambient temperature of the system
Remote access IPv4 address
Remote access IPv6 address
Specify and configure the LCD line number
View the encryption state report of the LCD
Configure LCD to indicate an active remote session when the Kernel-based Virtual Machine (KVM) is
available
NOTE: You can configure the Power and NMI buttons only if they are present on the system.
The following table displays the valid parameters for the command:
84