Dell OpenManage SNMP Reference Guide Version 7.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 2014 Dell Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual property laws.
Contents 1 Introduction............................................................................................................... 9 What’s New in This Release.................................................................................................................. 9 Supported SNMP Versions.................................................................................................................. 10 Introduction to the SNMP Reference Guide...................................................
System Resource Group..................................................................................................................... 87 System Resource Group Tables....................................................................................................87 System Resource Group Variable Values................................................................................... 100 Power Group.......................................................................................................
Field Replaceable Unit Group.......................................................................................................... 366 Field Replaceable Unit Group Tables......................................................................................... 366 Field Replaceable Unit Group Variable Values...........................................................................369 3 Storage Management Group.............................................................................
Inventory Collector Product Information........................................................................................ 477 5 Chassis Management Controller Group.........................................................479 Product Information......................................................................................................................... 479 Chassis Status..........................................................................................................................
iDRAC7 Supported SNMP Versions.................................................................................................. 527 iDRAC7 SNMP Data Security Features............................................................................................. 528 iDRAC7 Out-of-Band Group............................................................................................................ 528 RAC Information Group.........................................................................................
Introduction 1 This reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is applicable for Dell OpenManage Version 7. NOTE: This guide contains information that may also be applicable to earlier OpenManage supported platforms. This introduction is divided into two sections. The first section, Introduction to the SNMP Reference Guide, explains the SNMP Reference Guide design.
See Physical Memory Array Table for more information. – Added the following new varbind for: Baseboard Management Controller Group • * Added new MIB varbind for BMC Blade Form Factor. * Added variable values for Dell Blade Form Factor Type.
MIB Name Agent / Hardware Supported Purpose of the MIB instrumentation software. This is the primary MIB for PowerEdge systems. dcs3fru.mib Server Administrator Provides the information about the system Field Replaceable Unit (FRU) to SNMP management applications. dcstorag.mib Server Administrator Storage Management Provides the information about the storage hardware components and RAID configurations monitored by Server Administrator. iDRAC-SMIv1.
group number>, where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 1.
Section Topics MIB Group Numbers 18 Cost of Ownership Group — defines variables for tracking data on the system’s service contract, lease, repair records, trouble tickets, and so on 1600 20 Cluster Group — defines variables for systems that operate as a cluster 1800 21 Baseboard Management Controller Group — provides information about the Baseboard Management Controller (BMC) that may be present in your system.
1.3.6.1.4.1.674.10892.1. where is the MIB group number assigned to the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group. Table 3.
Table 5. Server Administrator Change Management MIB Sections in This Guide Section Topics MIB Group Number 24 Change Management Group describes the inventory data provided by the Change Management MIB that allows users to monitor devices and software present on a particular managed computer chassis 10899 Dell Remote Access Controller Out-of-Band MIB The Dell Remote Access Controller Out-of-Band MIB (filename dellRAC.
Basic Terminology It is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all essential terms used in describing the Server Administrator MIBs. For definitions on all essential terms and acronyms, see the Glossary available on the Dell Support website at dell.com/ support/manuals.
Table 8. UUID Table Name uUIDTable Object ID 1.3.6.1.4.1.674.10892.1.300.20 Description Defines the UUID table. Syntax SEQUENCE OF UUIDTableEntry Access Not accessible Table 9. UUID Table Entry Name uUIDTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.20.1 Description Defines the UUID table entry. Syntax UUIDTableEntry Access Not accessible Index uUIDIndex , uUIDchassisIndex Table 10. UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
Access Read-only Table 13. UUID Value Name uUIDValue Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.4 Description Defines the value of the UUID for this chassis. Syntax Octet String (SIZE[16]) Access Read-only Read-only Section Organization Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each section depends on the complexity of each MIB group. The first section provides a high-level introduction to the MIB group.
• The Server Administrator CIM Reference Guide documents the Common Information Model (CIM) provider, an extension of the standard management object format (MOF) file. The ServerAdministrator CIM provider documents supported classes of management objects. • The Glossary provides information on the terms used in this document.
Management Information Base Object Identifiers Each data class within a Management Information Base (MIB) is defined by an Object Identifier (OID). OIDs are unique across all MIBs. An OID consists of a series of digits separated by periods. The OID functions in a similar fashion to a phone number. The phone number 011-512-471-0000 uniquely identifies a single phone. The phone number can be broken down into a number of components to uniquely identify a phone.
system and network management data is not confidential, this limited security is acceptable for Get types of requests. On the other hand, this security is not acceptable for Set types of operations where an SNMP request could power off a system, reconfigure a redundant array of independent disks (RAID) card, and so on. Dell has chosen not to support SNMP Set operations for this reason. NOTE: The default SNMP agent configuration usually includes a SNMP community name such as public.
Server Administrator Group 2 The Server Administrator group comprises of the following sections: • Instrumentation MIB Version Group • Systems Management Software Group • System State Group • Chassis Information Group • Operating System Group • System Resource Group • Power Group • Thermal Group • Remote Flash BIOS Group • Port Group • Device Group • Slot Group • Memory Group • BIOS Setup Control Group • Local Response Agent Group • Cost of Ownership Group • Remote Access
Description Defines the major version number of the version of this MIB supported by the systems management software. For example, if the MIB version is 1.2.3, the major version number is 1. A major version number change indicates a major change in object functionality. Syntax DellUnsigned8BitRange Access Read-only Management Information Base Minor Version Number Name mIBMinorVersionNumber Object ID 1.3.6.1.4.1.674.10892.1.1.2.
To manage a system locally using Server Administrator, type the following in the address field of your browser: https://localhost:<1311 or user-specified port number> To manage a system remotely using Server Administrator, type one of the following in the address field of your browser: https://:<1311 or user specified port number> or https://:<1311 or user specified port number> Systems Management Software The following objects describe the fields for server administrator systems ma
Table 19. Systems Management Software Supported Protocol Name systemManagementSoftwareSupportedProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.5 Description Defines the systems management standards (SNMP or CIM) supported by the systems management software. Syntax SMSSupportedTypes (Systems Management Software Supported Standards) Access Read-only Table 20. Systems Management Software Preferred Protocol Name systemManagementSoftwarePreferredProtocol Object ID 1.3.6.1.4.1.674.10892.1.100.
Table 24. Systems Management Software Global Version Name Name systemManagementSoftwareGlobalVersionName Object ID 1.3.6.1.4.1.674.10892.1.100.10 Description Defines the global version of the systems management software. Syntax DellString Access Read-only Table 25. Systems Management Software Feature Flags Name systemManagementSoftwareFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.100.11 Description Defines the features of the systems management software.
supportsSNMPandDMI(3) This system supports SNMP and DMI. supportsCIMOM(4) This system supports CIM. supportsSNMPandCIMOM(5 ) This system supports SNMP and CIM. Table 29. Systems Management Software Feature Flags Variable Name: SMSFeatureFlags . Data Type: Integer Possible Data Values Meaning of Data Value none(0) The Systems Management Software features are not enabled. webOneToOneManagementP referred(1) The web 1:1 management preferred feature is enabled Table 30.
For example, systemStatePowerSupplyStatusCombined provides the rolled up status of all power supplies for the chassis. The variables in List 2 provide the health status of each component of the corresponding subsystem. Each octet of the value represents a component. If a power supply fails, the corresponding entry in systemStatePowerSupplyStatusDetails, systemStatePowerSupplyStatusCombined, systemStateChassisStatus and systemStateGlobalSystemStatus transitions to critical.
• systemStateSDCardUnitStatusList • systemStateSDCardDeviceStatusList System State Table The following object sets up the System State Table: Table 31. System State Table Name systemStateTable Object ID 1.3.6.1.4.1.674.10892.1.200.10 Description Defines the System State Table. Syntax SEQUENCE OF SystemStateTableEntry Access Not accessible Table 32. System State Table Entry Name systemStateTableEntry Object ID 1.3.6.1.4.1.674.10892.1.200.10.
Table 35. System State Chassis State Name systemStateChassisState Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.3 Description Defines the system state of this chassis. Syntax DellStateSettings Access Read-only Table 36. System State Chassis Status Name systemStateChassisStatus Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.4 Description Defines the system status of this chassis. Syntax DellStatus Access Read-only Table 37.
Description Defines the status of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific power unit. The first byte returned represents the status of the first power unit, the second byte returned represents the status of the second power unit, and so on. The bytes have the same definition type as DellStatusRedundancy. Syntax Octet String Access Read-only Table 40.
Table 43. System State Voltage State Details Name systemStateVoltageStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11 Description Defines the state of all voltage probes in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the status of a specific voltage probe. The first byte returned represents the status of the first voltage probe, the second byte returned represents the status of the second voltage probe, and so on.
Table 47. System State Amperage Status Combined Name systemStateAmperageStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.15 Description Defines the status of all amperage probes in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus. Syntax DellStatus Access Read-only Table 48. System State Amperage Status Details Name systemStateAmperageStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Access Read-only Table 51. System State Cooling Unit State Details Name systemStateCoolingUnitstateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.19 Description Defines the state of all cooling units in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of a specific cooling unit.
the status of a specific cooling device. The first byte returned represents the status of the first cooling device, the second byte returned represents the status of the second cooling device, and so on. The bytes have the same definition type as DellStatus. Syntax Octet String Access Read-only Table 55. System State Temperature State Details Name systemStateTemperatureStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.
Table 58. System State Memory Device State Details Name systemStateMemoryDeviceStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26 Description Defines the state of all memory devices in this chassis. The results are returned as a binary octet string. Each byte of the octet string represents the state of the specific memory device. The first byte returned represents the state of the first memory device, the second byte returned represents the status of the second memory device, and so on.
second intrusion detection device, and so on. The bytes have the same definition type as DellStateSettings. Syntax Octet String Access Read-only Table 62. System State Chassis Intrusion Status Combined Name systemStateChassisIntrusionStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.30 Description Defines the intrusion status of all intrusion detection devices in this chassis. The result is returned as a combined status value. The value has the same definition type as DellStatus.
Syntax DellStatusRedundancy Access Read-only Table 66. System State AC Power Switch Status Details Name systemStateACPowerSwitchStatusDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.34 Description Defines the individual status of all AC power switches in this chassis. The first byte returned represents the status of the first AC power switch, the second byte returned represents the status of the second AC power switch, and so on. Syntax Octet String Access Read-only Table 67.
Access Read-only Table 70. System State Redundant Memory Unit State Details Name systemStateRedundantMemoryUnitStateDetails Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38 Description Defines the state of all redundant memory units in this chassis. The results are returned as a binary octet string, each byte of the octet string represents the state of the specific object. The first byte returned represents the state of the first object, and so on.
Table 74. System State Power Unit Status Combined Name systemStatePowerUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.42 Description Defines the combined status of all power units of this chassis. Syntax DellStatus Access Read-only Table 75. System State Power Unit Status List Name systemStatePowerUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.43 Description Lists the status of each power unit of this chassis.
Table 78. System State AC Power Switch Status Combined Name systemStateACPowerSwitchStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.46 Description Defines the combined status of all AC power switches of this chassis. Syntax DellStatus Access Read-only Table 79. System State AC Power Switch Status List Name systemStateACPowerSwitchStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.47 Description Lists the status of each AC power switch of this chassis.
Table 82. System State Processor Device Status Combined Name systemStateProcessorDeviceStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.50 Description Defines the combined status of all processor devices of this chassis. Syntax DellStatus Access Read-only Table 83. System State Processor Device Status List Name systemStateProcessorDeviceStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.51 Description Lists the status of each processor device of this chassis.
Table 86. System State SD Card Unit Status Combined Name systemStateSDCardUnitStatusCombined Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.54 Description Defines the combined status of all SD Card units of this chassis. Syntax DellStatus Access Read-only Table 87. System State SD Card Unit Status List Name systemStateSDCardUnitStatusList Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.55 Description Lists the status of each SD Card unit of this chassis.
chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS), and so on.
Table 93. Chassis State Capabilities Name chassisStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.2 Description Defines the capabilities of the chassis. Syntax DellStateCapabilities Access Read-only Table 94. Chassis State Settings Name chassisStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.3 Description Defines the state settings for the chassis. Syntax DellStateSettings Access Read-only Table 95. Chassis Status Name chassisStatus Object ID 1.3.6.1.4.1.674.
Table 98. Chassis Name Name chassisName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.7 Description Defines the user-assigned chassis name of the chassis. Syntax DellString Access Read-only Table 99. Chassis Manufacturer Name Name chassisManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.8 Description Defines the manufacturer’s name for this chassis. Syntax DellString Access Read-only Table 100. Chassis Model Name Name chassisModelName Object ID 1.3.6.1.4.1.674.10892.1.300.
Description Defines the asset tag name for this chassis. Syntax DellUnsigned8BitRange Access Read-only Table 104. Chassis ID Extension Name chassisIDExtension Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.13 Description Defines the SMBIOS machine ID of this chassis. Syntax DellUnsigned16BitRange Access Read-only Table 105. Chassis System Class Name chassisSystemClass Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.14 Description Defines the chassis class of this chassis.
Table 109. Chassis System Location Name Name chassisSystemLocationName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.18 Description Defines the user-assigned location for this chassis. Syntax DellString Access Read-only Table 110. Chassis System Primary User Name Name chassisSystemPrimaryUserName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.19 Description Defines the user-assigned primary user name for this chassis. Syntax DellString Access Read-only Table 111.
Table 114. Chassis Fan Control Settings Unique Name chassisFanControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.23 Description Defines the readings and settings of the fan control hardware in the chassis. Syntax DellFanControlSettings Access Read-only Table 115. Chassis LED Control Capabilities Unique Name chassisLEDControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.24 Description Defines the capabilities of the LED control function in the chassis.
Table 119. Chassis Identify Flash Control Capabilities Name chassisIdentifyFlashControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28 Description Specifies whether the chassis front-panel LED can be set to flash. Syntax DellChassisIdentifyControlCapabilities (See Chassis Identification Control Capabilities) Access Read-only Table 120. Chassis Identify Flash Control Settings Name chassisIdentifyFlashControlSettings Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Table 124. Chassis Watchdog Control Capabilities Unique Name chassiswatchDogControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.33 Description Defines the capabilities of the watchdog timer object. Syntax DellWatchDogControlCapabilities (See Watchdog Control Capabilities) Access Read-only Table 125. Chassis Watchdog Control Settings Unique Name chassiswatchDogControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.
Table 129. Chassis Power Button Control Capabilities Unique Name chassisPowerButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.38 Description Defines the capabilities of the power button control function. Syntax DellPowerButtonControlCapabilities (See Power Button Control Capabilities) Access Read-only Table 130. Chassis Power Button Control Settings Unique Name chassisPowerButtonControlSettingsUnique Object ID . 1.3.6.1.4.1.674.10892.1.300.10.1.
Table 134. Chassis Reseller System ID Name chassisResellerSystemID Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.43 Description Defines the chassis reseller system ID. Syntax DellUnsigned16BitRange Access Read-only Table 135. Chassis NMI Button Control Capabilities Unique Name chassisNMIButtonControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.44 Description Defines the capabilities of the NMI button control function.
Table 139. Chassis System Revision Name Name chassisSystemRevisionName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.48 Description Defines the revision name of the system, if applicable. Syntax DellString Access Read-only Table 140. Chassis Express Service Code Name Name chassisExpressServiceCodeName Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.49 Description Defines the express service code of the chassis. Syntax DellString Access Read-only Table 141.
, uUIDchassisIndex Table 144. UUID Chassis Index Name uUIDchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 145. UUID Index Name uUIDIndex Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.2 Description Defines the index of the UUID in a specified chassis. Syntax DellObjectRange Access Read-only Table 146. UUID Type Name uUIDType Object ID 1.3.6.1.4.1.674.10892.1.300.20.1.
Table 148. POST Log Table Name postLogTable Object ID 1.3.6.1.4.1.674.10892.1.300.30 Description Defines the POST Log Table. Syntax SEQUENCE OF PostLogTableEntry Access Not accessible Table 149. POST Log Table Entry Name postLogTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.30.1 Description Defines the POST Log Table entry. Syntax PostLogTableEntry Access Not accessible Index postLogchassisIndex , postLogRecordIndex Table 150.
Access Read-only Table 153. POST Log State Settings Unique Name postLogStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.4 Description Defines the state of the object that is writing the POST log. Syntax DellStateSettingsLogUnique Access Read-only Table 154. POST Log Record Name postLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.30.1.5 Description Defines the data for the specified chassis and record index in the POST log being returned. Syntax DisplayString (SIZE (0..
Syntax EventLogTableEntry Access Not accessible Index eventLogchassisIndex , eventLogRecordIndex Table 158. Event Log Chassis Index Name eventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 159. Event Log Record Index Name eventLogRecordIndex Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.2 Description Defines the record index of the event log.
Table 162. Event Log Record Name eventLogRecord Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.5 Description Defines the data for the specified chassis and log record index in the event log being returned. Syntax DisplayString Access Read-only Table 163. Event Log Format Name eventLogFormat Object ID 1.3.6.1.4.1.674.10892.1.300.40.1.6 Description Defines the format of the event log. Syntax DellLogFormat (See Log Format) Access Read-only Table 164.
Description Defines the System BIOS Table. Syntax SEQUENCE OF SystemBIOSTableEntry Access Not accessible Table 167. System BIOS Table Entry Name systemBIOSTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.50.1 Description Defines the System BIOS Table entry. Syntax SystemBIOSTableEntry Access Not accessible Index systemBIOSchassisIndex , systemBIOSIndex Table 168. System BIOS Chassis Index Name systemBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.
Table 171. System BIOS State Settings Name systemBIOSStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.4 Description Defines the state of the system BIOS of this object. Syntax DellStateSettings Access Read-only Table 172. System BIOS Status Name systemBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.5 Description Defines the status of the system BIOS of this object. Syntax DellStatus Access Read-only Table 173. System BIOS Size Name systemBIOSSize Object ID 1.3.6.1.4.
Table 176. System BIOS Starting Address Name systemBIOSStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.9 Description Defines the starting address of the system BIOS. A zero (0) indicates that the address is unknown. Syntax DellUnsigned64BitRange Access Read-only Table 177. System BIOS Ending Address Name systemBIOSEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.10 Description Defines the ending address of the system BIOS. A zero (0) indicates that the address is unknown.
Bit 3 BIOS Characteristics Not Supported Bit 4 ISA is supported Bit 5 MCA is supported Bit 6 EISA is supported Bit 7 PCI is supported Bit 8 PC Card (PCMCIA) is supported Bit 9 Plug and Play is supported Bit 10 APM is supported Bit 11 BIOS is Upgradeable (Flash) Bit 12 BIOS shadowing is allowed Bit 13 VL-VESA is supported Bit 14 ESCD support is available Bit 15 Boot from CD is supported Bit 16 Selectable Boot is supported Bit 17 BIOS ROM is socketed Bit 18 Boot From PC Card
Syntax Bit 30 Int 10h, CGA/Mono Video Services are supported Bit 31 NEC PC-98 Bit 32 -47Reserved Bit 48 Built-in NIC supports Magic Packet Bit 49 System supports Wake-on-LAN Bit 50 System supports chassis intrusion Bit 51 Built-in NIC supports patternmatching Bit 52 System BIOS supports a 7character service tag Bit 53 -63 Reserved DellUnsigned64BitRange Table 180. System BIOS Characteristics Ext 1 Name systemBIOSCharacteristicsExt1 Object ID 1.3.6.1.4.1.674.10892.1.300.50.1.
Bit Position Meaning if Set Bit 0 BIOS Boot Specification supported Bit 1 Function key-initiated Network Service boot supported Bit 2 Targeted Content Distribution supported Bit 3 7Reserved Syntax DellUnsigned8BitRange Access Read-only Firmware Table Table 182. Firmware Table Name firmwareTable Object ID 1.3.6.1.4.1.674.10892.1.300.60 Description Defines the Firmware Table. Syntax SEQUENCE OF FirmwareTableEntry Access Not accessible Table 183.
Table 185. Firmware Index Name firmwareIndex Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.2 Description Defines the index (one-based) of the firmware in this chassis. Syntax DellObjectRange Access Read-only Table 186. Firmware State Capabilities Name firmwareStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.3 Description Defines the capabilities of the firmware states. Syntax DellStateCapabilities Access Read-only Table 187.
Table 190. Firmware Type Name firmwareType Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.7 Description Defines the type of the firmware. Syntax DellFirmwareType Access Read-only Table 191. Firmware Type Name Name firmwareTypeName Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.8 Description Defines the name of firmware type. Syntax DellString Access Read-only Table 192. Firmware Update Capabilities Name firmwareUpdateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.300.60.1.
Table 195. Intrusion Table Name intrusionTable Object ID 1.3.6.1.4.1.674.10892.1.300.70 Description Defines the Intrusion Table. Syntax SEQUENCE OF IntrusionTableEntry Access Not accessible Table 196. Intrusion Table Entry Name intrusionTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.70.1 Description Defines the Intrusion Table entry. Syntax IntrusionTableEntry Access Not accessible Index intrusionchassisIndex , intrusionIndex Table 197.
Table 200. Intrusion State Settings Name intrusionStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.4 Description Defines the settings of the intrusion object. Syntax DellStateSettings Access Read-only Table 201. Intrusion Status Name intrusionStatus Object ID 1.3.6.1.4.1.674.10892.1.300.70.1.5 Description Defines the status of the intrusion object. Syntax DellStatus Access Read-only Table 202. Intrusion Reading Name intrusionReading Object ID 1.3.6.1.4.1.674.10892.1.300.70.
Table 205. Baseboard Table Name baseBoardTable Object ID 1.3.6.1.4.1.674.10892.1.300.80 Description Defines the Baseboard Table. Syntax SEQUENCE OF BaseBoardTableEntry Access Not accessible Table 206. Baseboard Table Entry Name baseBoardTableEntry Object ID 1.3.6.1.4.1.674.10892.1.300.80.1 Description Defines the Baseboard Table entry. Syntax BaseBoardTableEntry Access Not accessible Index baseBoardChassisIndex , baseBoardIndex Table 207.
Table 210. Baseboard State Settings Name baseBoardStateSettings Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.4 Description Defines the state settings of the baseboard. Syntax DellStateSettings Access Read-only Table 211. Baseboard Status Name baseBoardStatus Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.5 Description Defines the status of the baseboard. Syntax DellStatus Access Read-only Table 212. Baseboard Feature Flags Name baseBoardFeatureFlags Object ID 1.3.6.1.4.1.674.10892.1.300.
Description Defines the location name of the baseboard. Syntax DellString Access Read-only Table 216. Baseboard Manufacturer Name Name baseBoardManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.10 Description Defines the baseboard manufacturer’s name. Syntax DellString Access Read-only Table 217. Baseboard Product Name Name baseBoardProductName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.11 Description Defines the baseboard product’s name.
Table 221. Baseboard Asset Tag Name Name baseBoardAssetTagName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.15 Description Defines the baseboard asset tag name. Syntax DellString Access Read-only Table 222. Baseboard Express Service Code Name Name baseBoardExpressServiceCodeName Object ID 1.3.6.1.4.1.674.10892.1.300.80.1.16 Description Defines the express service code of the baseboard.
lapTop(9) The chassis type is a laptop. noteBook(10) The chassis type is a notebook. handHeld(11) The chassis type is a handheld. dockingStation(1 2) The chassis type is a docking station. allInOne(13) The chassis type is an all-in-one. subNoteBook(14) The chassis type is a subnotebook. spaceSaving(15) The chassis type is a spacesaver. lunchBox(16) The chassis type is a lunch box. mainSystemChassi s(17) The chassis type is the main system chassis.
lowSpeedCapable( 2) The fan can be set to low speed. highSpeedCapabl e(4) The fan can be set to high speed. lowOrhighSpeedCa pable(6) The fan can be set to low or high speed. Table 227. Front-Panel LED Control Capabilities Variable Name : DellLEDControlCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The LED control capabilities are unknown. alertOnErrorCapa ble(2) The LED control can be set to alert on an error condition.
resetCapable(8) The hard-drive fault LED can be reset. Table 230. Hard-Drive Fault LED Control Settings Variable Name : DellHDFaultLEDControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The LEDs do not have any fault settings capabilities. unknown(1) The hard-drive fault LEDs’ state is unknown. enabled(2) The hard-drive fault LEDs’ state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).
unknown(1) The chassis identification control’s state is unknown.. enabled(2) The chassis identification control’s state is disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReady(4) The chassis identification control’s state is not ready. identifyChassis( The chassis identification control’s LEDs may 8) be returned to (normal) 0, or (identify chassis) 1.
manualPowerOffWi The operator can power off without thoutOSSh operating system shutdown. utdownCapable(12 8) manualPowerCycle The operator can power cycle with operating WithOSShu system shutdown. tdownCapable(256 ) manualPowerCycle The operator can power cycle without WithoutOS operating system shutdown. ShutdownCapable( 512) Table 234. Host Control Settings Variable Name : DellHostControlSettings NOTE: An operator can manually cause these actions using SNMP.
automaticPowerOf Watchdog controls can be set to fCapable(16) automatically power off host. automaticAllExce Watchdog controls can be set to ptNotificationCa automatically perform all functions except p able(27) notification capable. automaticFullyCa Watchdog controls can be set to pable(31) automatically perform all functions. Table 236.
enableCapable(2) The power button can be enabled (online) or disabled (offline). Table 239. Power Button Control Settings Variable Name : DellPowerButtonControlSettings Data Type: Integer Possible Data Values Meaning of Data Value none(0) The power button has no settings capabilities. unknown(1) The power button settings are unknown. enabled(2) The power button state is enabled. disabled(4) The power button state is disabled. Table 240.
Table 243. Baseboard Type Variable Name : DellBaseBoardType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The baseboard type is unknown. other(2) The baseboard type is not one of the following types. serverBlade(3) The baseboard type is a server blade. connectivitySwit The baseboard type is a connectivity switch. ch(4) systemManagement The baseboard type is a system management Module(5) module. processorModule( The baseboard type is a processor module.
Table 245. Firmware Type Variable Name : DellFirmwareType Data Type: Integer Possible Data Values Meaning of Data Value other(1) The firmware type is other than following values. unknown(2) The firmware type is unknown. systemBIOS(3) The firmware type is System BIOS embeddedSystemMa The firmware type is Embedded System nagementContro Management Controller. ller(4) powerSupplyParal The firmware type is Power Supply Paralleling lelingBoard(5) Board.
Data Type: Integer Possible Data Values Meaning of Data Value NOTE: These values are bit fields, so combination values are possible. no features(0) This baseboard has no feature flags. boardIsHostingBo This baseboard is a hosting board. ard(1) boardRequiresDau This baseboard requires at least one daughter ghterBoard (2) board or auxiliary card. boardIsRemovabl e(4) This baseboard is removable. boardIsReplaceab This baseboard is replaceable. le(8) boardIsHotSwappa This baseboard is hot swappable.
Table 249. Operating System Memory Chassis Index Name operatingSystemMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 250. Operating System Memory State Capabilities Name operatingSystemMemoryStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.2 Description Defines the capabilities of the operating system memory.
Table 254. Operating System Memory Available Physical Size Name operatingSystemMemoryAvailablePhysicalSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.6 Description Defines the available physical memory size in kilobytes. Syntax DellUnsigned32BitRange Access Read-only Table 255. Operating System Memory Total Page File Size Name operatingSystemMemoryTotalPageFileSize Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.7 Description Defines the total page file memory size in kilobytes.
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.11 Description This attribute defines the total physical memory for the operating system memory in KBytes. Syntax DellUnsigned64BitRange Access Read-only System Resource Group The Management Information Base (MIB) variables presented in this section enable you to track various attributes of your system resources.
Table 262. System Resource Map Chassis Index Name systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 263. System Resource Map Index Name systemResourceMapIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.2 Description Defines the index of system resource maps in this chassis. Syntax DellObjectRange Access Read-only Table 264.
Description Defines the type of this system map. Syntax DellSystemResourceMapType (System Resource Map Type) Access Read-only System Resource Owner Table Table 268. System Resource Owner Table Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.10892.1.500.20 Description Defines the System Resource Owner Table. Syntax SEQUENCE OF SystemResourceOwnerTableEntry Access Not accessible Table 269. System Resource Owner Table Entry Name systemResourceOwnerTable Object ID 1.3.6.1.4.1.674.
Table 272. System Resource Owner State Capabilities Name systemResourceOwnerStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.3 Description Defines the capabilities of this system resource owner. Syntax DellStateCapabilities Access Read-only Table 273. System Resource Owner State Settings Name systemResourceOwnerStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.4 Description Defines the state settings of this system resource owner.
Description Defines the description name of the system resource owner. Syntax DellString Access Read-only Table 278. System Resource Owner Interface Instance Name systemResourceOwnerInterfaceInstance Object ID 1.3.6.1.4.1.674.10892.1.500.20.1.9 Description Defines the associated system resource owner interface instance in this chassis. Syntax DellObjectRange Access Read-only System Resource Input/Output (I/O) Port Table Table 279.
Table 282. System Resource I/O Port Index Name systemResourceIOPortIndex Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.2 Description Defines the index (one-based) of the system resource I/O ports in this chassis. Syntax DellObjectRange Access Read-only Table 283. System Resource I/O Port State Capabilities Name systemResourceIOPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.3 Description Defines the capabilities of the system resource I/O port.
Table 287. System Resource I/O Port Share Disposition Name systemResourceIOPortShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.7 Description Defines the share disposition of the system resource I/O port. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 288. System Resource I/O Port Starting Address Name systemResourceIOPortStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.500.30.1.
, systemResourceMemoryIndex Table 292. System Resource Memory Chassis Index Name systemResourceMemorychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 293. System Resource Memory Index Name systemResourceMemoryIndex Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.2 Description Defines the index of system resource memory in this chassis.
Name systemResourceMemoryOwnerIndexReference Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.6 Description Defines the index to the associated system resource owner in this chassis. Syntax DellObjectRange Access Read-only Table 297. System Resource Memory Share Disposition Name systemResourceMemoryShareDisposition Object ID 1.3.6.1.4.1.674.10892.1.500.40.1.7 Description Defines the share disposition of the system resource memory.
System Resource Interrupt Table Table 301. System Resource Interrupt Table Name systemResourceInterruptTable Object ID 1.3.6.1.4.1.674.10892.1.500.50 Description Defines the System Resource Interrupt Table. Syntax SEQUENCE OF SystemResourceInterruptTableEntry Access Not accessible Table 302. System Resource Interrupt Table Entry Name systemResourceInterruptTableEntry Object ID 1.3.6.1.4.1.674.10892.1.500.50.1 Description Defines the System Resource Interrupt Table entry.
Access Read-only Table 306. System Resource Interrupt State Settings Name systemResourceInterruptStateSettings Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.4 Description Defines the state of this system resource interrupt. Syntax DellStateSettings Access Read-only Table 307. System Resource Interrupt Status Name systemResourceInterruptStatus Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.5 Description Defines the status of this system resource interrupt.
Table 311. System Resource Interrupt Type Name systemResourceInterruptType Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.9 Description Defines the interrupt type of the system resource interrupt. Syntax DellResourceInterruptType (Resource Interrupt Type) Access Read-only Table 312. System Resource Interrupt Trigger Name systemResourceInterruptTrigger Object ID 1.3.6.1.4.1.674.10892.1.500.50.1.10 Description Defines the interrupt trigger of the system resource interrupt.
Table 316. System Resource DMA Index Name systemResourceDMAIndex Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.2 Description Defines the index of system resource DMAs in this chassis. Syntax DellObjectRange Access Read-only Table 317. System Resource DMA State Capabilities Name systemResourceDMAStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.3 Description Defines the capabilities of this system resource DMA. Syntax DellStateCapabilities Access Read-only Table 318.
Description Defines the share disposition of the system resource DMA. Syntax DellResourceShareDisposition (Resource Share Disposition) Access Read-only Table 322. System Resource DMA Maximum Transfer Size Name systemResourceDMAMaximumTransferSize Object ID 1.3.6.1.4.1.674.10892.1.500.60.1.8 Description Defines the maximum size of a memory transfer in bytes for the system resource DMA. Syntax DellUnsigned32BitRange Access Read-only Table 323.
Table 326. Resource Owner Interface Type Variable Name: DellResourceOwnerInterfaceType Data Type: Integer Possible Data Values Meaning of Data Value typeIsOther(1) The interface type is not one of the following: typeIsUnknown(2) The interface type is unknown. typeIsInternal(3) The interface type is internal. typeIsISA(4) The interface type is an Industry Standard Architecture (ISA) bus. typeIsEISA(5) The interface type is an Extended Industry Standard Architecture (EISA) bus.
memoryIsF24(16) The resource memory is F24. Table 329. Resource Interrupt Type Variable Name: DellResourceInterruptType Data Type: Integer Possible Data Values Meaning of Data Value interruptIsLevelSensit ive(1) The interrupt type is level sensitive. interruptIsLatched(2) The interrupt type is latched. Table 330.
dmaTransferWidthIs16Bi ts(4) The DMA transfer width is 16 bits. dmaTransferWidthIs32Bi ts(5) The DMA transfer width is 32 bits. dmaTransferWidthIs64Bi ts(6) The DMA transfer width is 64 bits. dmaTransferWidthIs128B its(7) The DMA transfer width is 128 bits. Power Group The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and voltage and amperage probes.
Access Read-only Index powerUnitchassisIndex, powerUnitIndex Table 335. Power Unit Chassis Index Name powerUnitchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 336. Power Unit Index Name powerUnitIndex Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.2 Description Defines the index of the power unit in this chassis. Syntax DellObjectRange Access Read-only Table 337.
Table 340. Power Supply Count for Redundancy Name powerSupplyCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.6 Description Defines the total number of power supplies required for this power unit to have redundancy. Syntax DellString Access Read-only Table 341. Power Unit Name Name powerUnitName Object ID 1.3.6.1.4.1.674.10892.1.600.10.1.7 Description Defines the name of the power unit in this chassis. Syntax DellString Access Read-only Table 342.
Table 345. Power Supply Chassis Index Name powerSupplychassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 346. Power Supply Index Name powerSupplyIndex Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.2 Description Defines the index of power supply. Syntax DellObjectRange Access Read-only Table 347.
Table 350. Power Supply Output Watts Name powerSupplyOutputWatts Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.6 Description Defines the maximum sustained output wattage of the power supply in tenths of watts. Syntax DellSigned32BitRange Access Read-only Table 351. Power Supply Type Name powerSupplyType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.7 Description Defines the type of power supply. Syntax DellPowerSupplyType (Power Supply Type Definitions) Access Read-only Table 352.
Description Defines the state reported by the power supply sensor, and supplements the state and settings of the power supply. Syntax DellPowerSupplySensorState (Power Supply Sensor State) Access Read-only Table 356. Power Supply Configuration Error Type Name powerSupplyConfigurationErrorType Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.12 Description Defines the type of configuration error reported by the power supply sensor.
Description Defines the Voltage Probe Table entry. Syntax VoltageProbeTableEntry Access Not accessible Index voltageProbechassisIndex, voltageProbeIndex Table 361. Voltage Probe Chassis Index Name voltageProbechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 362. Voltage Probe Index Name voltageProbeIndex Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
Access Read-only Table 366. Voltage Probe Reading Name voltageProbeReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.6 Description Defines the value of the voltage probe reading. The value is an integer representing the voltage in millivolts that the probe is reading. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Table 367. Voltage Probe Type Name voltageProbeType Object ID 1.3.6.
Access Read-only Table 371. Voltage Probe Upper Noncritical Threshold Name voltageProbeUpperNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.11 Description Defines the user-assigned value of the voltage probe’s upper noncritical threshold. Syntax DellSigned32BitRange Access Read-only Table 372. Voltage Probe Lower Noncritical Threshold Name voltageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.
Table 376. Voltage Probe Discrete Reading Name voltageProbeDiscreteReading Object ID 1.3.6.1.4.1.674.10892.1.600.20.1.16 Description Defines the reading for a voltage probe of type voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe.
Description Defines the index of amperage probes in this chassis. Syntax DellObjectRange Access Read-only Table 381. Amperage Probe State Capabilities Name amperageProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.3 Description Defines the capabilities of the amperage probe. Syntax DellStateCapabilities Access Read-only Table 382. Amperage Probe State Settings Name amperageProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.
amperageProbeTypeIsSystemWatts, the value returned for this attribute is the amperage that the probe is reading in Milliamps. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, a value is not returned for this attribute. Syntax DellSigned32BitRange Access Read-only Table 385. Amperage Probe Type Name amperageProbeType Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.7 Description Defines the type of the amperage probe. Syntax DellAmperageProbeType Access Read-only Table 386.
Description Defines the user-assigned value of the amperage probe’s upper critical threshold. Syntax DellSigned32BitRange Access Read-only Table 390. Amperage Probe Lower Noncritical Threshold Name amperageProbeLowerNonCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.600.30.1.12 Description Defines the user-assigned value of the amperage probe’s lower noncritical threshold. Syntax DellSigned32BitRange Access Read-only Table 391.
When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for amperageProbeType is amperageProbeTypeIsDiscrete, the value returned for this attribute is the discrete reading for the probe. Syntax DellAmperageDiscreteReading (Amperage Probe Discrete Reading) Access Read-only AC Power Switch Table Table 395. AC Power Switch Table Name aCPowerSwitchTable Object ID 1.3.6.1.4.1.674.10892.1.600.
Table 399. AC Power Switch Capabilities Name aCPowerSwitchCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.3 Description Defines the capabilities of this AC power switch. Syntax DellACPowerSwitchCapabilities Access Read-only Table 400. AC Power Switch Settings Name aCPowerSwitchSettings Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.4 Description Defines the settings of this AC power switch. Syntax DellACPowerSwitchSettings Access Read-only Table 401.
Description Defines the redundancy mode of this AC power switch. Syntax DellACPowerSwitchRedundancyMode Access Read-only Table 405. AC Power Switch Status Name aCPowerSwitchStatus Object ID 1.3.6.1.4.1.674.10892.1.600.40.1.9 Description Defines the status of this AC power switch. Syntax DellStatus Access Read-only AC Power Cord Table Table 406. AC Power Cord Table Name aCPowerCordTable Object ID 1.3.6.1.4.1.674.10892.1.600.42 Description Defines the AC Power Cord Table.
Table 409. AC Power Cord Index Name aCPowerCordIndex Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.2 Description Defines the index (one-based) of this AC power cord. Syntax DellObjectRange Access Read-only Table 410. AC Power Cord State Capabilities Name aCPowerCordStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.42.1.3 Description Defines the capabilities of this AC power cord. Syntax DellACPowerCordStateCapabilities Access Read-only Table 411.
Description Defines the location name of this AC power cord. Syntax DellString Access Read-only Battery Table Table 415. Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Table 416. Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.1 Description Defines the Battery Table Entry.
Access Read-only Table 420. Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-only Table 421. Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Description Defines the status of the battery. Syntax DellStatus Access Read-only Table 422. Battery Reading Name batteryReading Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.
Table 425. Power Usage Table Entry Name powerUsageTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.60.1 Description Defines the Power Usage Table Entry. Syntax PowerUsageTableEntry Access Not accessible Index powerUsageChassisIndex , powerUsageIndex Table 426. Power Usage Chassis Index Name powerUsageChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 427.
Table 430. Power Usage Status Name powerUsageStatus Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.5 Description Defines the status of the power usage information. Syntax DellStatus Access Read-only Table 431. Power Usage Entity Name Name powerUsageEntityName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.6 Description Defines the name of the entity associated with this power usage information. Syntax DellString Access Read-only Table 432.
Table 435. Power Usage Peak Watts Start Date Name Name powerUsagePeakWattsStartDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.10 Description Defines the date and time at which the data collection started for the value reported by the powerUsagePeakWatts attribute. Syntax DellDateName Access Read-only Table 436. Power Usage Peak Watts Reading Date Name Name powerUsagePeakWattsReadingDateName Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Table 440. Power Usage Idle Power Name powerUsageIdlePower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.15 Description Defines the system idle power (in Watts). This is the minimum power the system can consume based on the current hardware configuration. Syntax DellUnsigned32BitRange Access Read-only Table 441. Power Usage Max Potential Power Name powerUsageMaxPotentialPower Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.16 Description Defines the maximum potential power (in Watts) of the system.
Table 445. Power Usage Instantaneous Headroom Name powerUsageInstantaneousHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.20 Description Defines the system instantaneous headroom (in Watts). This is the theoretical maximum power drawn by the power supply minus instantaneous power draw. Syntax DellUnsigned32BitRange Access Read-only Table 446. Power Usage Peak Headroom Name powerUsagePeakHeadroom Object ID 1.3.6.1.4.1.674.10892.1.600.60.1.
Table 450. Power Profile Index Name powerProfileIndex Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.2 Description Defines the index (one-based) of the power profile information. Syntax DellObjectRange Access Read-only Table 451. Power Profile Supported Profiles Name powerProfileSupportedProfiles Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.3 Description Defines the supported power profiles. Syntax DellPowerProfileType Access Read-only Table 452.
Table 455. Power Profile Custom Memory Management Capabilities Name powerProfileCustomMemoryManagementCapabilities Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.7 Description Defines the custom memory power and performance management capabilities that are available for the Custom power profile. Syntax DellMemoryPowerPerformanceManagementType Access Read-only Table 456. Power Profile Custom Memory Management Capabilities Name powerProfileCustomMemoryManagementSetting Object ID 1.3.6.1.4.1.674.
onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The power supply’s capabilities are not ready. Table 460. Power Supply State Settings Unique Variable Name: DellPowerSupplyStateSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The power supply’s capabilities are unknown.
powerSupplyTypeIsSwitching(4) The power supply type is a switching power supply. powerSupplyTypeIsBattery(5) The power supply type is a battery. powerSupplyTypeIsUPS(6) The power supply type is an uninterruptable power supply. powerSupplyTypeIsConverter(7) The power supply type is a power converter power supply. powerSupplyTypeIsRegulator(8) The power supply type is a regulator power supply. powerSupplyTypeIsAC(9) The power supply type is an AC power supply.
processorMissing(3) The power supply configuration error type is processor missing. Table 464. Voltage Probe Type Variable Name: DellVoltageType Data Type: Integer Possible Data Values Meaning of Data Value voltageProbeTypeIsOther(1) The voltage probe type is not one of the following: voltageProbeTypeIsUnknown(2) The voltage probe type is unknown (not known or not monitored). voltageProbeTypeIs1Point5Volt (3) The voltage probe type is a 1.5-volt (V) probe.
Table 466. Amperage Probe Definitions Variable Name: DellAmperageType Data Type: Integer Possible Data Values Meaning of Data Value amperageProbeTypeIsOther(1) The amperage probe type is not one of the following: amperageProbeTypeIsUnknown(2) The amperage probe type is unknown (not known or not monitored). amperageProbeTypeIs1Point5Volt(3) The amperage probe type is a 1.5-ampere (A) probe. amperageProbeTypeIs3Point3volt(4) The amperage probe type is a 3.3-A probe.
amperageProbeTypeIsSystemWatts(26) The amperage probe type is system probe with reading in Watts. Table 467. Amperage Probe Discrete Reading Variable Name: DellAmperageDiscreteReading Data Type: Integer Possible Data Values Meaning of Data Value amperageIsGood(1) The amperage probe discrete reading is good. amperageIsBad(2) The amperage probe discrete reading is bad. Table 468.
nonRedundant(1) The AC power switch is not expecting redundancy. redundant(2) The AC power switch is expecting redundancy. Table 471. AC Power Cord State Capabilities Variable Name: DellACPowerCordStateCapabilities Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) The AC power cord’s capabilities are unknown. onlineCapable(2) The AC power cord can be disabled (offline) or enabled (online). notReadyCapable(4) The AC power cord’s capabilities are not ready. Table 472.
NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value none(0) No power cap capabilities are available. enable(1) Power cap can be enabled. disable(2) Power cap can be disabled. Table 475. Power Cap Setting Variable Name: DellPowerCapSetting Data Type: Integer Possible Data Values Meaning of Data Value disabled(0) Power cap is disabled. enabled(1) Power cap is enabled. Table 476.
systemDBPM(8) CPU power and performance management type is System Demand Based Power Management. Table 478. Memory Power Performance Management Type Variable Name: DellMemoryPowerPerformanceManagementType Data Type: Integer NOTE: These values are bit masks, so combination values are possible. Possible Data Values Meaning of Data Value maxPerformance(1) Memory power and performance management type is Maximum Performance. mhz1333(2) Memory power and performance is 1333 MHz. .
• Temperature Probe Table Cooling Unit Table Table 480. Cooling Unit Table Name coolingUnitTable Object ID 1.3.6.1.4.1.674.10892.1.700.10 Description Defines the Cooling Unit Table. Syntax TableEntry Access Not accessible Table 481. Cooling Unit Table Entry Name coolingUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.10.1 Description Defines the Cooling Unit Table entry. Syntax TableEntry Access Not accessible Index coolingUnitchassisIndex , coolingUnitIndex Table 482.
Access Read-only Table 485. Cooling Unit State Settings Name coolingUnitStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.4 Description Defines the state and settings of the cooling unit. Syntax DellStateSettings Access Read-only Table 486. Cooling Unit Redundancy Status Name coolingUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.700.10.1.5 Description Defines the redundancy status of the cooling unit. Syntax DellStatusRedundancy Access Read-only Table 487.
Cooling Device Table Table 490. Cooling Device Table Name coolingDeviceTable Object ID 1.3.6.1.4.1.674.10892.1.700.12 Description Defines the Cooling Device Table. Syntax CoolingDeviceTableEntry Access Not accessible Table 491. Cooling Device Table Entry Name coolingDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.12.1 Description Defines the Cooling Device Table entry.
Access Read-only Table 495. Cooling Device State Settings Name coolingDeviceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.4 Description Defines the state and settings of the cooling device. Syntax DellStateSettings Access Read-only Table 496. Cooling Device Status Name coolingDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.5 Description Defines the status of the cooling device. Syntax DellStatusProbe Access Read-only Table 497.
Access Read-only Table 500. Cooling Device Upper Nonrecoverable Threshold Name coolingDeviceUppernonrecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.9 Description Defines the value of the fan’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 501. Cooling Device Upper Critical Threshold Name coolingDeviceUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.10 Description Defines the value of the fan’s upper critical threshold.
Table 505. Cooling Device Lower Nonrecoverable Threshold Name coolingDeviceLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.14 Description Defines the value of the fan’s lower nonrecoverable threshold. Syntax DellSigned32BRead-onlyitRange Access Read-only Table 506. Cooling Device Cooling Unit Index Reference Name coolingDevicecoolingUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.700.12.1.
Temperature Probe Table Table 510. Temperature Probe Table Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10892.1.700.20 Description Defines the Temperature Probe Table. Syntax TemperatureProbeTableEntry Access Not accessible Table 511. Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.20.1 Description Defines the Temperature Probe Table entry.
Access Read-only Table 515. Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-only Table 516. Temperature Probe Status Name temperatureProbeStatus Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.5 Description Defines the status of the temperature probe in tenths of degrees Celsius.
Syntax DellString Access Read-only Table 520. Temperature Probe Upper Nonrecoverable Threshold Name temperatureProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.9 Description Defines the value of the temperature probe’s upper nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 521. Temperature Probe Upper Critical Threshold Name temperatureProbeUpperCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Access Read-only Table 525. Temperature Probe Lower Nonrecoverable Threshold Name temperatureProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.14 Description Defines the value of the temperature probe’s lower nonrecoverable threshold. Syntax DellSigned32BitRange Access Read-only Table 526. Temperature Probe Probe Capabilities Name temperatureProbeProbeCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
coolingDeviceTypeIsABlower(4) The cooling device type is a centrifugal blower. coolingDeviceTypeIsAChipFan(5) The cooling device type is a fan on an integrated circuit. coolingDeviceTypeIsACabinetFan(6) The cooling device type is a cabinet fan. coolingDeviceTypeIsAPowerSupplyFan(7) The cooling device type is a power supply fan. coolingDeviceTypeIsAHeatPipe(8) The cooling device type is a heat pipe. coolingDeviceTypeIsRefrigeration(9) The cooling device type is an integrated refrigeration unit.
Possible Data Values Meaning of Data Value temperatureProbeTypeIsOther(1) The temperature probe subtype is not one of the following: temperatureProbeTypeIsUnknown(2) The temperature probe subtype is unknown (not known or not monitored). temperatureProbeTypeIsAmbientESM(3) The temperature probe is for ambient Embedded Systems Management (ESM). temperatureProbeTypeIsDiscrete(16) The temperature probe subtype is a temperature probe with discrete reading. Table 532.
Access Not accessible Index remoteFlashBIOSchassisIndex, remoteFlashBIOSIndex Table 535. Remote Flash BIOS Chassis Index Name remoteFlashBIOSchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 536. Remote Flash BIOS Index Name remoteFlashBIOSIndex Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.2 Description Defines the index to the remote BIOS update hardware on this system.
Table 539. Remote Flash BIOS Status Name remoteFlashBIOSStatus Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.5 Description Defines the status of the remote BIOS update hardware on this system. Syntax DellRemoteFlashBIOSStateStatus Access Read-only Table 540. Remote Flash BIOS Last BIOS Date Name Name remoteFlashBIOSLastBIOSDateName Object ID 1.3.6.1.4.1.674.10892.1.900.10.1.6 Description Defines the date of the last BIOS update. Syntax DellDateName Access Read-only Table 541.
unknown(1) The remote flash BIOS’s capabilities are unknown. enableCapable(2) The remote flash BIOS can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The remote flash BIOS can be set to indicate not ready. cancelCapable(8) Flash of BIOS can be canceled. enableAndCancelCapable(10) Flash of BIOS can be enabled or canceled. Table 544.
completionCodeIsNoExternalPower(10) An external power adapter must be connected. completionCodeIsNo12VoltSet(11) 12 volts (V) could not be set. completionCodeIsNo12VoltRemoval(12) 12 V could not be removed. completionCodeIsFlashMemoryFailed (13) A flash memory failure occurred. completionCodeIsGeneralFailure(14) A general failure occurred. completionCodeIsDataMiscompare(15) A data miscompare error occurred. completionCodeIsNoImageFound(16) The flash BIOS image could not be found in memory.
Description Defines the Pointing Port Table entry. Syntax PointingPortTableEntry Access Not accessible Index pointingPortchassisIndex , pointingPortIndex Table 548. Pointing Port Chassis Index Name pointingPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 549. Pointing Port Index Name pointingPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.10.1.
Table 552. Pointing Port Status Name pointingPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.10.5 Description Defines the status of the pointing port. Syntax DellStatus Access Read-only Table 553. Pointing Port Security State Name pointingPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.10.6 Description Defines the security settings of the pointing port. Syntax DellPortSecurityState Access Read-only Table 554.
Keyboard Port Table Table 557. Keyboard Port Table Name keyboardPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.20 Description Defines the Keyboard Port Table. Syntax IntegerKeyboardPortTableEntry Access Not accessible Table 558. Keyboard Port Table Entry Name keyboardPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1 Description Defines the Keyboard Port Table entry.
Description Defines the capabilities of the keyboard port. Syntax DellStateCapabilities Access Read-only Table 562. Keyboard Port State Settings Name keyboardPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.4 Description Defines the state and settings of the keyboard port. Syntax DellStateSettings Access Read-only Table 563. Keyboard Port Status Name keyboardPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.5 Description Defines the status of the keyboard port.
Syntax DellString Access Read-only Table 567. Keyboard Port BIOS Connector Type Name keyboardPortBIOSConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.20.1.9 Description Defines the BIOS connector type of the keyboard port. Syntax DellGenericPortConnectorType Access Read-only Processor Port Table Table 568. Processor Port Table Name processorPortTable Object ID 1.3.6.1.4.1.674.10892.1.1000.30 Description Defines the Processor Port Table.
Table 571. Processor Port Index Name processorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2 Description Defines the index of the processor ports in this chassis. Syntax DellObjectRange Access Read-only Table 572. Processor Port State Capabilities Name processorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.3 Description Defines the capabilities of the processor port. Syntax DellStateCapabilities Access Read-only Table 573.
Table 576. Processor Port Connector Type Name processorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.7 Description Defines the connector type of the processor port. Syntax DellProcessorPortConnectorType (See Processor Port Connector Types) Access Read-only Table 577. Processor Port Name Name processorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.30.1.8 Description Defines name of the processor port. Syntax DellString Access Read-only Table 578.
Index memoryDevicePortchassisIndex , memoryDevicePortIndex Table 581. Memory Device Port Chassis Index Name memoryDevicePortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 582. Memory Device Port Index Name memoryDevicePortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.2 Description Defines the index of the memory device port in this chassis.
Syntax DellStatus Access Read-only Table 586. Memory Device Port Security State Name memoryDevicePortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.6 Description Defines the security settings of the memory device port. Syntax DellPortSecurityState Access Read-only Table 587. Memory Device Port Connector Type Name memoryDevicePortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.7 Description Defines the connector type of the memory device port.
Syntax DellUnsigned32BitRange Access Read-only Table 591. Memory Device Port Physical Memory Card Index Reference Name memoryDevicePortPhysicalMemoryCardIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1000.40.1.11 Description Defines the index (one-based) of the Physical Memory Card Table entry for the physical memory card with the same chassis index that this memory device port is associated with (if any). Syntax DellUnsigned32BitRange Access Read-only Monitor Port Table Table 592.
Table 595. Monitor Port Index Name monitorPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2 Description Defines the index of the monitor ports in this chassis. Syntax DellObjectRange Access Read-only Table 596. Monitor Port State Capabilities Name monitorPortStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.3 Description Defines the capabilities of the monitor port. Syntax DellStateCapabilities Access Read-only Table 597.
Table 600. Monitor Port Connector Type Name monitorPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7 Description Defines the connector type of the monitor port. Syntax DellMonitorPortConnectorTypes (See Monitor Port Connector Types) Access Read-only Table 601. Monitor Port Name Name monitorPortName Object ID 1.3.6.1.4.1.674.10892.1.1000.50.1.8 Description Defines the name of the monitor port. Syntax DellString Access Read-only Table 602.
, sCSIPortIndex Table 605. SCSI Port Chassis Index Name sCSIPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.1 Description Defines the index (one-based) of this chassis Syntax DellObjectRange Access Read-only Table 606. SCSI Port Index Name sCSIPortIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.2 Description Defines the index of the SCSI ports in this chassis. Syntax DellObjectRange Access Read-only Table 607.
Access Read-only Table 610. SCSI Port Security State Name sCSIPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.6 Description Defines the security settings of the SCSI port. Syntax DellPortSecurityState Access Read-only Table 611. SCSI Port Connector Type Name sCSIPortConnectorType Object ID 1.3.6.1.4.1.674.10892.1.1000.60.1.7 Description Defines the connector type of the SCSI port.
Access Not accessible Table 615. Parallel Port Table Entry Name parallelPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1 Description Defines the Parallel Port Table entry. Syntax ParallelPortTableEntry Access Not accessible Index parallelPortchassisIndex , parallelPortIndex Table 616. Parallel Port Chassis Index Name parallelPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.1 Description Defines the index (one-based) of this chassis.
Description Defines the state and settings of the parallel port. Syntax DellStateSettings Access Read-only Table 620. Parallel Port Status Name parallelPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.5 Description Defines the status of the parallel port. Syntax DellStatus Access Read-only Table 621. Parallel Port Security State Name DellPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.6 Description Defines the security state of the parallel port.
Syntax DellParallelPortConnectorPinout Access Read-only Table 625. Parallel Port Capabilities Unique Name parallelPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.10 Description Defines the capabilities of the parallel port. Syntax DellParallelPortConnectorPinout Access Read-only Table 626. Parallel Port Base I/O Address Name parallelPortBaseIOAddress Object ID 1.3.6.1.4.1.674.10892.1.1000.70.1.
Syntax IntegerSerialPortTableEntry Access Not accessible Table 630. Serial Port Table Entry Name serialPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1 Description Defines the Serial Port Table entry. Syntax SerialPortTableEntry Access Not accessible Index serialPortchassisIndex , serialPortIndex Table 631. Serial Port Chassis Index Name serialPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.1 Description Defines the index (one-based) of this chassis.
Table 634. Serial Port State Settings Name serialPortStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.4 Description Defines the state and settings of the serial port. Syntax DellStateSettings Access Read-only Table 635. Serial Port Status Name serialPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.5 Description Defines the status of the serial port. Syntax DellStatus Access Read-only Table 636. Serial Port Security State Name serialPortSecurityState Object ID 1.3.6.
Table 639. Serial Port Maximum Speed Name serialPortMaximumSpeed Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9 Description Defines the maximum speed the serial interface can support in bits per second (bps). Syntax DellUnsigned32BitRange Access Read-only Table 640. Serial Port Capabilities Unique Name serialPortCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1000.80.1.10 Description Defines additional capabilities of the serial port.
Access Not accessible Table 644. USB Port Table Entry Name uSBPortTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1 Description Defines the USB Port Table entry. Syntax USBPortTableEntry Access Not accessible Index uSBPortchassisIndex , uSBPortIndex Table 645. USB Port Chassis Index Name uSBPortchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 646.
Access Read-only Table 649. USB Port Status Name uSBPortStatus Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.5 Description Defines the state of the USB port. Syntax DellStatus Access Read-only Table 650. USB Port Security State Name uSBPortSecurityState Object ID 1.3.6.1.4.1.674.10892.1.1000.90.1.6 Description Defines the security settings of the USB port. Syntax DellPortSecurityState Access Read-only Table 651. USB Port Connector Type Name uSBPortConnectorType Object ID 1.3.6.1.4.
connectorPortTypeIsOther( 1) The pointing port connector type is not one of the following: connectorPortTypeIsUnknow n(2) The pointing port connector type is unknown. connectorPortTypeIsSeria l(3) The pointing port connector type is serial. connectorPortTypeIsPS2(4) The pointing port connector type is a Personal System/2 (PS/2). connectorPortTypeIsInfrar ed(5) The pointing port connector type is infrared. connectorPortTypeIsHPHIL( 6) The pointing port connector type is HP-HIL.
connectorPortTypeIsAccessBusUSB(9) The keyboard port connector type is bus USB. connectorPortTypeIsPC98(10) The keyboard port connector type is PC-98. Table 655. Processor Port Connector Types Variable Name : DellProcessorPortConnectorType Data Type: Integer Possible Data Values Meaning of Data Value connectorPortTypeIsOther(1) The processor port connector type is not one of the following: connectorPortTypeIsUnknown(2) The processor port connector type is unknown.
connectorPortTypeIsZIP(7) The memory device port connector type is a ZIP. connectorPortTypeIsAProprietaryCard(8) The memory device port connector type is a proprietary card. connectorPortTypeIsDIMM(9) The memory device port connector type is a dual in-line memory module (DIMM). connectorPortTypeIsTSOP(10) The memory device port connector type is a TSOP. connectorPortTypeIsARowOfChips(11) The memory device port connector type is a row of chips.
about type, settings, configuration, manufacturer, address or location, and if applicable, the speed of the device.
Table 661. Pointing Device Chassis Index Name pointingDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 662. Pointing Device Index Name pointingDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.2 Description Defines the index of the pointing device in this chassis. Syntax DellObjectRange Access Read-only Table 663.
Description Defines the index to the pointing port in this chassis. Syntax DellObjectRange Access Read-only Table 667. Pointing Device Type Name pointingDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.7 Description Defines the type of the pointing device. Syntax DellPointingDeviceType (See Pointing Device Type) Access Read-only Table 668. Pointing Device Number of Buttons Name pointingDeviceNumberofButtons Object ID 1.3.6.1.4.1.674.10892.1.1100.10.1.
Table 671. Keyboard Device Chassis Index Name keyboardDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 672. Keyboard Device Index Name keyboardDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.2 Description Defines the index of the keyboard device for this chassis. Syntax DellObjectRange Access Read-only Table 673.
Description Defines the index to the associated the keyboard port in this chassis. Syntax DellStatus Access Read-only Table 677. Keyboard Device Type Name Name keyboardDeviceTypeName Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.7 Description Defines the name of the keyboard type. Syntax DellString Access Read-only Table 678. Keyboard Device Layout Name Name keyboardDeviceLayoutName Object ID 1.3.6.1.4.1.674.10892.1.1100.20.1.8 Description Defines the name of the keyboard layout.
Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 682. Processor Device Index Name processorDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.2 Description Defines the index of the processor device in this chassis. Syntax DellObjectRange Access Read-only Table 683. Processor Device State Capabilities Name processorDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.
Table 687. Processor Device Type Name processorDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7 Description Defines the type of processor device. Syntax DellProcessorDeviceType (See Processor Device Type) Access Read-only Table 688. Processor Device Manufacturer Name Name processorDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.8 Description Defines the name of manufacturer of the processor device. Syntax DellString Access Read-only Table 689.
Description Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 693. Processor Device External Clock Speed Name processorDeviceExternalClockSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.13 Description Defines the speed of the external clock (the front-side bus speed) for the processor device in MHz. A zero (0) indicates that the speed is unknown.
Description Defines the number of processor cores detected for the processor device. Syntax DellUnsigned32BitRange Access Read-only Table 698. Processor Device Core Enabled Count Name processorDeviceCoreEnabledCount Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.18 Description Defines the number of processor cores enabled for the processor device. Syntax DellUnsigned32BitRange Access Read-only Table 699. Processor Device Thread Count Name processorDeviceThreadCount Object ID 1.3.6.1.4.1.
Table 701. Processor Device Extended Capabilities Name processorDeviceExtendedCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21 Description This attribute defines extended capabilities of the processor device. This attribute is a bit field where a bit has the meaning defined below when set to 1 (one).
Table 704. Processor Device Model Name Name processorDeviceModelName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24 Description Defines the model of the processor device. Syntax DellString Access Read-only Table 705. Processor Device Stepping Name Name processorDeviceSteppingName Object ID 1.3.6.1.4.1.674.10892.1.1100.30.1.25 Description Defines the stepping of the processor device. Syntax DellString Access Read-only Processor Device Status Table Table 706.
Table 709. Processor Device Status Index Name processorDeviceStatusIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2 Description Defines the index (one-based) of the processor device status probe. Syntax DellObjectRange Access Read-only Table 710. Processor Device Status State Capabilities Name processorDeviceStatusStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.3 Description Defines the state capabilities of the processor device status probe.
Description Defines the location name of the processor device status probe. Syntax DellString Access Read-only Table 715. Processor Device Status Port Index Reference Name processorDeviceStatusPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.32.1.8 Description Defines the index (one-based) of the associated processor port in the same chassis. Syntax DellObjectRange Access Read-only Cache Device Table Table 716. Cache Device Table Name cacheDeviceTable Object ID 1.3.6.1.4.1.674.
Table 719. Cache Device Index Name cacheDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2 Description Defines the index of the cache device in this chassis. Syntax DellObjectRange Access Read-only Table 720. Cache Device State Capabilities Name cacheDeviceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.3 Description Description Defines the capabilities of the cache device. Syntax DellStateCapabilities Access Read-only Table 721.
Description Defines the type of cache device. Syntax DellCacheDeviceType (See Cache Device Type) Access Read-only Table 725. Cache Device Location Name cacheDeviceLocation Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.8 Description Defines the location of the cache device. Syntax DellCacheDeviceLocation (See Cache Device Location) Access Read-only Table 726. Cache Device Status State Name cacheDeviceStatusState Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.
Access Read-only Table 730. Cache Device Current Size Name cacheDeviceCurrentSize Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13 Description Defines the current size of the cache device in KB. A zero (0) indicates that the size is unknown. Syntax DellUnsigned32BitRange Access Read-only Table 731. Cache Device Speed Name cacheDeviceSpeed Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.14 Description Defines the speed of the cache device in nanoseconds.
Table 735. Cache Device Associativity Name cacheDeviceAssociativity Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.18 Description Defines the type of associativity in use by the cache device. Syntax DellCacheDeviceAssociativity (See Cache Device Associativity) Access Read-only Table 736. Cache Device Supported Type Name cacheDeviceSupportedType Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.19 Description Defines the type of static random-access memory (SRAM) that the cache device can support.
, memoryDeviceIndex Table 740. Memory Device Chassis Index Name memoryDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 741. Memory Device Index Name memoryDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.2 Description Defines the index of the memory device in this chassis. Syntax DellObjectRange Access Read-only Table 742.
Table 745. Memory Device Memory Port Index Reference Name memoryDeviceMemoryPortIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6 Description Defines the index of the memory port of which this memory device is part. Syntax DellObjectRange Access Read-only Table 746. Memory Device Type Name memoryDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.7 Description Defines the type of the memory device.
Access Read-only Table 750. Memory Device Type Details Name memoryDeviceTypeDetails Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11 Description Defines the detailed type of the memory device. Syntax DellMemoryDeviceTypeDetails (See Memory Device Type Details) Access Read-only Table 751. Memory Device Form Factor Name memoryDeviceFormFactor Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.12 Description Defines the form factor of the memory device.
Access Read-only Table 755. Memory Device Total Bus Width Name memoryDeviceTotalBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16 Description Defines the total number of bits, including ECC, used by the memory device. Syntax DellUnsigned32BitRange Access Read-only Table 756. Memory Device Total Data Bus Width Name memoryDeviceTotalDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.17 Description Defines the total number of data bits used by the memory device.
Table 759. Memory Device Failure Modes Name memoryDeviceFailureModes Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20 Description Defines the failure modes of the memory device when the memoryDeviceStatus attribute is not OK. It is a bit field that can be used to report more than one type of failure mode by using a combination of the defined bit masks. Syntax DellMemoryDeviceFailureModes Access Read-only Table 760. Memory Device Manufacturer Name Name memoryDeviceManufacturerName Object ID 1.3.
Table 764. Memory Device Speed Name Name memoryDeviceSpeedName Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25 Description This attribute defines the speed of the memory device in string format with units specified in string. Syntax DellString Access Read-only Table 765. Memory Device Rank Name memoryDeviceRank Object ID 1.3.6.1.4.1.674.10892.1.1100.50.1.26 Description 1100.0050.0001.0026 — This attribute defines the Rank of the memory device (DIMM). Zero indicates an unknown.
Access Not accessible Table 768. Memory Device Mapped Address Table Entry Name memoryDeviceMappedAddressTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1 Description Defines the Memory Device Mapped Address Table entry. Syntax MemoryDeviceMappedAddressTableEntry Access Not accessible Index memoryDeviceMappedAddresschassisIndex , memoryDeviceMappedAddressIndex Table 769. Memory Device Mapped Address Chassis Index Name memoryDeviceMappedAddresschassisIndex Object ID 1.3.6.1.4.1.674.
Syntax DellStateSettings Access Read-only Table 773. Memory Device Mapped Address Status Name memoryDeviceMappedAddressStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.5 Description Defines the status of the memory device mapped address. Syntax DellStatus Access Read-only Table 774. Memory Device Index Reference Name memoryDeviceIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Syntax DellUnsigned32BitRange Access Read-only Table 778. Memory Device Mapped Address Starting Address Name memoryDeviceMappedAddressStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.10 Description Defines the physical starting address in KB of the memory device mapped address. Syntax DellUnsigned64BitRange Access Read-only Table 779. Memory Device Mapped Address Ending Address Name memoryDeviceMappedAddressEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.
Table 782. Generic Device Chassis Index Name genericDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 783. Generic Device Index Name genericDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.2 Description Defines the index of the generic device in this chassis. Syntax DellObjectRange Access Read-only Table 784.
Description Defines the index of the system slot into which this generic device is plugged. Syntax DellObjectRange Access Read-only Table 788. Generic Device Type Name genericDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.7 Description Defines the type of the generic device. Syntax DellGenericDeviceType (See Generic Device Type) Access Read-only Table 789. Generic Device Name Name genericDeviceName Object ID 1.3.6.1.4.1.674.10892.1.1100.70.1.
Table 792. PCI Device Chassis Index Name pCIDevicechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 793. PCI Device Index Name pCIDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.2 Description Defines the index (one-based) of the PCI device in this chassis. Syntax DellObjectRange Access Read-only Table 794.
Description Defines the index number of the system slot that this PCI device is in. Syntax DellObjectRange Access Read-only Table 798. PCI Device Data Bus Width Name pCIDeviceDataBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.7 Description Defines the bus width of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only Table 799. PCI Device Manufacturer Name Name pCIDeviceManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.1100.80.1.
PCI Device Configuration Space Table Table 803. PCI Device Configuration Space Table Name pCIDeviceConfigurationSpaceTable Object ID 1.3.6.1.4.1.674.10892.1.1100.82 Description Defines the PCI Device Configuration Table. Syntax SEQUENCE OF PCIDeviceConfigurationSpaceTableEntry Access Not accessible Table 804. PCI Device Configuration Space Table Entry Name pCIDeviceConfigurationSpaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.82.
Access Read-only Table 808. PCI Device Configuration Space State Settings Name pCIDeviceConfigurationSpaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.4 Description Defines the state of the PCI device configuration. Syntax DellStateSettings Access Read-only Table 809. PCI Device Configuration Space Status Name pCIDeviceConfigurationSpaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.5 Description Defines the status of the PCI device configuration.
Table 813. PCI Device Configuration Space Function Number Name pCIDeviceConfigurationSpaceFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.9 Description Defines the function number of the PCI device in this chassis. Syntax DellUnsigned32BitRange Access Read-only Table 814. PCI Device Configuration Space Header Name pCIDeviceConfigurationSpaceHeader Object ID 1.3.6.1.4.1.674.10892.1.1100.82.1.10 Description Defines the common configuration space header of the PCI device.
Access Read-only Table 818. Network Device Index Name networkDeviceIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2 Description Defines the index (one-based) of the network device. Syntax DellObjectRange Access Read-only Table 819. Network Device Status Name networkDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.3 Description Defines the status of the network device. Syntax DellStatus Access Read-only Table 820.
Table 823. Network Device Vendor Name Name networkDeviceVendorName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.7 Description Defines the name of the vendor of the network device. Syntax DellString Access Read-only Table 824. Network Device Service Name Name networkDeviceServiceName Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.8 Description Defines the service name of the network device. Syntax DellString Access Read-only Table 825.
Description Defines the IP subnet mask for the IP address currently assigned to the network device. Syntax IpAddress Access Read-only Table 829. Network Device Default Gateway IP Address Name networkDeviceDefaultGatewayIPAddress Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.13 Description Defines the IP address of the default gateway for the network device. Syntax IpAddress Access Read-only Table 830. Network Device DHCP Server IP Address Name networkDeviceDHCPServerIPAddress Object ID 1.
Syntax DellUnsigned8BitRange Access Read-only Table 834. Network Device PCI Device Number Name networkDevicePCIDeviceNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18 Description Defines the PCI device number of the network device. Syntax DellUnsigned8BitRange Access Read-only Table 835. Network Device PCI Function Number Name networkDevicePCIFunctionNumber Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19 Description Defines the PCI function number of the network device.
Table 839. Network Device TOE Capability Flags Name networkDeviceTOECapabilityFlags Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.23 Description Defines the TCP/IP Offload Engine (TOE) capability flags of the network device. Syntax DellNetworkDeviceTOECapabilityFlags (See Network Device TOE Capability Flags) Access Read-only Table 840. Network Device TOE Enabled Name networkDeviceTOEEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.
Table 844. Network Device iSCSI Enabled Name networkDeviceiSCSIEnabled Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.28 Description Defines if iSCSI is enabled for the network device. Syntax DellBoolean Access Read-only Managed System Services Device Table Table 845. Managed System Services Device Table Name Object ID 1.3.6.1.4.1.674.10892.1.1100.100 Description Defines the Managed System Services Device Table.
Access Read-only Table 849. Managed System Services Device Status Name managedSystemServicesDeviceStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.3 Description Defines the status of the managed system services device. Syntax DellStatus Access Read-only Table 850. Managed System Services Device Type Name managedSystemServicesDeviceType Object ID 1.3.6.1.4.1.674.10892.1.1100.100.1.4 Description Defines the type of the managed system services device.
Access Not accessible Table 854. SD Card Unit Table Entry Name sdCardUnitTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1 Description Defines the SD Card Unit Table Entry. Syntax SdCardUnitTableEntry Access Not accessible Index sdCardUnitChassisIndex , sdCardUnitIndex Table 855. SD Card Unit Chassis Index Name sdCardUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card unit.
Access Read-only Table 859. SD Card Unit Redundancy Status Name sdCardUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.5 Description Defines the redundancy status of the SD Card unit. Syntax DellStatusRedundancy Access Read-only Table 860. SD Card Unit Count For Redundancy Name sdCardUnitCountForRedundancy Object ID 1.3.6.1.4.1.674.10892.1.1100.110.1.6 Description Defines the total number of SD Card devices required for this SD Card unit to have full redundancy.
Table 864. SD Card Device Table Entry Name sdCardDeviceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1 Description Defines the SD Card Device Table Entry. Syntax SdCardDeviceTableEntry Access Not accessible Index sdCardDeviceChassisIndex , sdCardDeviceIndex Table 865. SD Card Device Chassis Index Name sdCardDeviceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.1 Description Defines the index (one-based) of the chassis that contains the SD Card device.
Table 869. SD Card Device Config Capabilities Name sdCardDeviceConfigCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.5 Description Defines the configuration capabilities of the SD Card device. Syntax DellSDCardDeviceConfigCapabilities Access Read-only Table 870. SD Card Device Config Settings Name sdCardDeviceConfigSettings Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.6 Description Defines the configuration settings of the SD Card device.
Description Defines the storage size in MB (megabytes) of the SD card for the SD Card device. Syntax DellUnsigned32BitRange Access Read-only Table 875. SD Card Device Unit Index Reference Name sdCardDeviceUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1100.112.1.11 Description Defines the index to the associated SD Card unit if the SD Card device is part of a SD Card unit. Syntax DellObjectRange Access Read-only Table 876.
deviceTypeIsATrack Ball(4) Device type is a track ball. deviceTypeIsATrack Point(5) Device type is a track point. deviceTypeIsAGlide Point(6) Device type is a glide point. deviceTypeIsATouch Pad(7) Device type is a touch pad. Table 879. Processor Device Status State Variable Name:DellProcessorDeviceStatusState Data Type:Integer Possible Data Values Meaning of Data Value other(1) Processor device type is not one of the following: unknown(2) Device type is unknown.
Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) The processor device type is not one of the following values: deviceTypeIsUnkno The processor device type is unknown. wn(2) deviceTypeIsCPU(3 The processor device type is a central ) processing unit. deviceTypeIsMathP The processor device type is a math rocessor(4) processor. deviceTypeIsDSP(5 The processor device type is a digital signal ) processor. deviceTypeIsAVide The processor device is a video processor.
processorUpgradeI Upgrade is by Slot M. sBySlotM(12) processorUpgradeI Upgrade is by Socket 423. sByScoket423(13) processorUpgradeI Upgrade is by Socket A (Socket 462). sBySocketA(14) processorUpgradeI Upgrade is by Socket 478. sBySocket478(15) processorUpgradeI Upgrade is by Socket 754. sBySocket754(16) processorUpgradeI Upgrade is by Socket 940. sBySocket940(17) processorUpgradeI Upgrade is by Socket 939. sBySocket939(18) processorUpgradeI Upgrade is by Socket mPGA604.
deviceFamilyIs802 The processor family is 80286. 86(4) deviceFamilyIs803 The processor family is 80386. 86(5) deviceFamilyIs804 The processor family is 80486. 86(6) deviceFamilyIS808 The processor family is 8087. 7(7) deviceFamilyIs802 The processor family is 80287. 87(8) deviceFamilyIs803 The processor family is 80387. 87(9) deviceFamilyIs804 The processor family is 80487. 87(10) deviceFamilyIsPen The processor family is Intel Pentium. tium(11) deviceFamilyIsPen The processor family is Pentium Pro.
deviceFamilyIsK6( The processor family is K6. 26) deviceFamilyIsK6- The processor family is K6-2. 2(27) deviceFamilyIsK6- The processor family is K6-3. 3(28) deviceFamilyIsAMD The processor family is AMD Athlon. Athlon(29) deviceFamilyIsAMD The processor family is AMD2900. 2900(30) deviceFamilyIsK6- The processor family is K6-2+. 2Plus(31) deviceFamilyIsPow The processor family is Power PC. erPC(32) deviceFamilyIsPow The processor family is Power PC 601.
deviceFamilyIsAlp The processor family is Alpha 21164. ha21164(51) deviceFamilyIsAlp The processor family is Alpha 21164PC. ha21164PC(52) deviceFamilyIsAlp The processor family is Alpha 21164a. ha21164a(53) deviceFamilyIsAlp The processor family is Alpha 21264. ha21264(54) deviceFamilyIsAlp The processor family is Alpha 21364. ha21364(55) deviceFamilyIsAMD The processor family is AMD Turion II Ultra TurionIIUltra Dual-Core Mobile M Processor Family.
deviceFamilyIsmic The processor family is microSPARC II. roSPARCII(82) deviceFamilyIsmic The processor family is microSPARC IIep. roSPARCIIep (83) deviceFamilyIsUlt The processor family is UltraSPARC. raSPARC(84) deviceFamilyIsUlt The processor family is UltraSPARC II. raSPARCII(85) deviceFamilyIsUlt The processor family is UltraSPARC IIi. raSPARCIIi(86) deviceFamilyIsUlt The processor family is UltraSPARC III. raSPARCIII(87) deviceFamilyIsUlt The processor family is UltraSPARC IIIi.
deviceFamilyIsAMD The processor family is AMD Turion 64 Turion64Mobile(13 Mobile Technology. 4) deviceFamilyIsDua The processor family is Dual-Core AMD lCoreAMDOpter Opteron. on(135) deviceFamilyIsAMD The processor family is AMD Athlon 64 X2 Athlon64X2Dual Dual-Core. Core(136) deviceFamilyIsAMD The processor family is AMD Turion 64 X2 Turion64X2Mob Mobile Technology. ile(137) deviceFamilyIsQua The processor family is Quad-Core AMD dCoreAMDOpter Opteron.
deviceFamilyIsQua The processor family is Quad-Core Intel dCoreIntelXeon320 Xeon processor 3200 Series. 0(161) deviceFamilyIsDua The processor family is Dual-Core Intel Xeon lCoreIntelXeon300 processor 3000 Series. 0(162) deviceFamilyIsQua The processor family is Quad-Core Intel dCoreIntelXeon530 Xeon processor 5300 Series. 0(163) deviceFamilyIsDua The processor family is Dual-Core Intel Xeon lCoreIntelXeon510 processor 5100 Series.
deviceFamilyIsM2( The processor family is M2. 177) deviceFamilyIsInt The processor family is Intel Pentium 4 HT elPentium4HT processor. (179) deviceFamilyIsAS4 The processor family is AS400. 00(180) deviceFamilyIsAMD The processor family is AMD Athlon XP. AthlonXP(182) deviceFamilyIsAMD The processor family is AMD Athlon MP. AthlonMP(183) deviceFamilyIsAMD The processor family is AMD Duron. Duron(184) deviceFamilyIsInt The processor family is Intel Pentium M.
deviceFamilyIsInt The processor family is Intel Core i7 elCorei7(198) processor. deviceFamilyIsDua The processor family is Dual-Core Intel lCoreIntelCel Celeron Processor. eron(199) deviceFamilyIsIBM The processor family is IBM390. 390(200) deviceFamilyIsG4( The processor family is G4. 201) deviceFamilyIsG5( The processor family is G5. 202) deviceFamilyIsESA The processor family is ESA/390 G6. 390G6(203) deviceFamilyIszAr The processor family is z/Architectur base.
deviceFamilyIsDua The processor family is Dual-Core Intel Xeon lCoreIntelXeo processor 7xxx Series. n7xxx(221) deviceFamilyIsQua The processor family is Quad-Core Intel dCoreIntelXeo Xeon processor 7xxx Series. n7xxx(222) deviceFamilyIsMul The processor family is Multi-Core Intel tiCoreIntelXe Xeon processor 7xxx Series. on7xxx(223) deviceFamilyIsMul The processor family is Multi-Core Intel tiCoreIntelXe Xeon processor 3400 Series.
deviceFamilyIsAMD The processor family family is AMD Opteron Opteron4200 (61) 4200 Series Processor. Table 884. Cache Device Type Variable Name:DellCacheDeviceType Data Type:Integer Possible Data Values Meaning of Data Value deviceTypeIsOthe r(1) System cache type is not one of the following: deviceTypeIsUnkno System cache type is unknown. wn(2) deviceTypeIsInstr System cache type is instruction. uction(3) deviceTypeIsData( System cache type is data.
deviceWritePolicy Device write policy is write through. IsWriteThrough(4) deviceWritePolicy Device write policy varies by address. IsVariesByAddres s(5) deviceWritePolicy Device write policy is determined by I/O IsDeterminedByIO( query. 6) Table 887. Cache Device Status State Variable Name:DellCacheDeviceStatusState Data Type:Integer Possible Data Values Meaning of Data Value other(1) Device state is not one of the following: unknown(2) Device state is unknown. enabled(3) Device is enabled.
deviceAssociativi Device associativity is not one of the tyIsOther(1) following: deviceAssociativi Device associativity is unknown. tyIsUnknown(2) deviceAssociativi Device is direct mapped. tyIsDirectMapped( 3) deviceAssociativi Device is two-way set associative. tyIsTwoWaySetAsso ciative(4) deviceAssociativi Device is four-way set associative. tyIsFourWaySetAss o ciative(5) deviceAssociativi Device is fully associative. tyIsFullyAssociat ive (6) deviceAssociativi Device is eight-way set associative.
deviceLocationIsI Device location is internal. nternal(3) deviceLocationIsE Device location is external. xternal(4) Table 891. Cache Device Static Random-Access Memory (SRAM) Type Variable Name:DellCacheDeviceSRAMType Data Type:Integer Possible Data Values Meaning of Data Value deviceSRAMTypeIsO Device SRAM type is not one of the ther(1) following: deviceSRAMTypeIsU Device SRAM type is unknown. nknown(2) deviceSRAMTypeIsN Device SRAM type is nonburst.
deviceFormFactorI Device form factor is a proprietary card. sAProprietaryCar d(8) deviceFormFactorI Device form factor is DIMM. sDIMM(9) deviceFormFactorI Device form factor is TSOP. sTSOP(10) deviceFormFactorI Device form factor is a row of chips. sARowOfChips(11) deviceFormFactorI Device form factor is RIMM. sRIMM(12) deviceFormFactorI Device form factor is SODIMM. sSODIMM(13) deviceFormFactorI Device form factor is SRIMM. sSRIMM(14) deviceFormFactorI Device form factor is FB-DIMM. sFBDIMM(15) Table 893.
deviceTypeIsEPRO M(12) Device type is EPROM. deviceTypeIsCDRA M(13) Device type is CDRAM. deviceTypeIs3DRA M(14) Device type is 3DRAM. deviceTypeIsSDRA M(15) Device type is SDRAM. deviceTypeIsSGRA M(16) Device type is SGRAM. deviceTypeIsRDRA M(17) Device type is RDRAM. deviceTypeIsDDR(1 Device type is DDR. 8) deviceTypeIsDDR2( Device type is DDR2. 19) deviceTypeIsDDR2F Device type is DDR2 FB-DIMM. BDIMM(20) deviceTypeIsDDR3( Device type is DDR3. 24) deviceTypeIsFBD2( Device type is FBD2.
deviceTypeDetailI The detailed device type is CMOS. sCMOS(256) deviceTypeDetailI The detailed device type is EDO. sEDO(512) deviceTypeDetailI The detailed device type is Window DRAM. sWindowDRAM (1024) deviceTypeDetailI The detailed device type is Cache DRAM. sCacheDRAM (2048) deviceTypeDetailI The detailed device type is Non-volatile. sNonVolatile (4096) deviceTypeDetailI The detailed device type is registered. sRegistered (8192) deviceTypeDetailI The detailed device type is nonregistered.
Memory device has no faults. (0) eccSingleBitCorre Memory device has exceeded the ctionWarningRate( Correctable Memory Event warning rate. 1) eccSingleBitCorre Memory device has exceeded the ctionFailureRate( Correctable Memory Event failure rate. 2) eccMultiBitFault( Memory device has encountered an 4) Uncorrectable Memory Event. eccSingleBitCorre Correctable Memory Event logging for ctionLoggingDisab memory device has been disabled.
noTeam(1) Device is not part of any team. teamingEnabled(2) Teaming is enabled. adapterFaultToler Adapter fault tolerance teaming mode. anceMode(4) loadBalancingMod e(8) Load balancing teaming mode. Table 899. Network Device TOE Capability Flags Variable Name:DellNetworkDeviceTOECapabilityFlags Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for TOE capability is not supported.
Table 901. Network Device iSCSI Capability Flags Variable Name:DellNetworkDeviceiSCSICapabilityFlags Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) Querying for iSCSI capability is not supported. unknown(1) Querying for iSCSI capability is supported but query returned an error. available(2) Device has iSCSI capability. notAvailable(4) Device does not have iSCSI capability.
none(0) SD card device has none of the following capabilities. sdCapable(1) SD media can be enabled. vFlashCapable(2) Virtual Flash (vFlash) can be enabled. Table 905. SD Card Device Config Settings Variable Name:DellSDCardDeviceConfigSettings Data Type:Integer NOTE: These values are bit fields, so combination values are possible. Possible Data Values Meaning of Data Value none(0) SD card device has none of the following settings. sdEnabled(1) SD media is enabled.
offline(8) Device is offline. failed(16) Device is failed. active(32) Device is active. bootable(64) Device is bootable. writeProtect(128) Device is write-protected. standby(256) Device is in standby mode. Slot Group The Slot Group provides information about the types of slots that your system supports. This management information base (MIB) group also provides information about the voltages, capabilities, states, and settings that are possible for these slots.
Syntax DellObjectRange Access Read-only Table 911. System Slot Index Name systemSlotIndex Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2 Description Defines the index (one-based) of the system slot in this chassis. Syntax DellObjectRange Access Read-only Table 912. System Slot State Capabilities Unique Name systemSlotStateCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.3 Description Defines the capabilities of the system slot.
Access Read-only Table 916. System Slot Type Name systemSlotType Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7 Description Defines the type of the system slot. Syntax DellSystemSlotType (System Slot Type) Access Read-only Table 917. System Slot External Slot Name Name systemSlotSlotExternalSlotName Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.8 Description Defines the external connector name of the system slot. Syntax DellString Access Read-only Table 918.
Access Read-only Table 921. System Slot Hot-Plug Bus Width Name systemSlotHotPlugBusWidth Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12 Description Defines the bus width of the hot-plug system slot. Syntax DellSystemSlotHotPlugBusWidth (Hot-Plug Bus Width) Access Read-only Table 922. System Slot Hot-Plug Slot Speed Name systemSlotHotPlugSlotSpeed Object ID 1.3.6.1.4.1.674.10892.1.1200.10.1.13 Description Defines the slot speed in megahertz of the hot-plug system slot.
systemSlotHotPlugCanSignal Attention(8) The system slot attention state (and corresponding LED) can be set. systemSlotHotPlugCanSignal PowerFault(16) Power on fault (and corresponding LED) can be detected due to a short or overcurrent. systemSlotHotPlugCanSignal AdapterPresent(32) Adapter (card) present in slot (may not be powered) can be detected. systemSlotHotPlugCanSignal PowerButtonPressed(64) The system slot power button can be pressed to signal a toggle of the power state.
systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) is on. systemSlotHotPlugHasPowerFaulted (16) Power on fault (and corresponding LED) was detected due to a short or overcurrent. systemSlotHotPlugAdapterIsPresent (32) Adapter (card) present in slot (may not be powered). systemSlotHotPlugAdapterPresentAnd PoweredOn(36) Adapter (card) present in slot and powered.
systemSlotIsISA(3) The system slot is Industry Standard Architecture (ISA). systemSlotIsMCA(4) The system slot is Micro Channel Architecture (MCA). systemSlotIsEISA(5) The system slot is Extended Industry Standard Architecture (EISA). systemSlotIsPCI(6) The system slot is Peripheral Component Interconnect (PCI). systemSlotIsPCMCIA(7) .
systemSlotIsPCIExpressGen2(171) The system slot type is PCI Express Gen 2. systemSlotIsPCIExpressGen2X1(172) The system slot type is PCI Express Gen 2 x1. systemSlotIsPCIExpressGen2X2(173) . The system slot type is PCI Express Gen 2 x2 systemSlotIsPCIExpressGen2X4(174) The system slot type is PCI Express Gen 2 x4. systemSlotIsPCIExpressGen2X8(175) The system slot type is PCI Express Gen 2 x8. systemSlotIsPCIExpressGen2X16(176) The system slot type is PCI Express Gen 2 x16. Table 927.
Table 930. Hot-Plug Bus Width Variable Name: DellSystemSlotHotPlugBusWidth Data Type: Integer Possible Data Values Meaning of Data Value busWidthIsOther(1) The system slot bus width is not one of following: busWidthIsUnknown(2) The system slot bus width is unknown. busWidthIs8bits(3) The system slot bus width is 8 bits. busWidthIs16bits(4) The system slot bus width is 16 bits. busWidthIs32bits(5) The system slot bus width is 32 bits. busWidthIs64bits(6) The system slot bus width is 64 bits.
Physical Memory Array Table The physical memory array is the entire physical memory of a system.
Syntax DellObjectRange Access Read-only Table 934. Physical Memory Array Index Name physicalMemoryArrayIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.2 Description Defines the index (one-based) of the physical memory array in this chassis. Syntax DellObjectRange Access Read-only Table 935. Physical Memory Array State Capabilities Name physicalMemoryArrayStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.3 Description Defines the capabilities of the physical memory array.
Syntax DellPhysicalMemoryArrayUse (See Physical Memory Array ECC Type Definitions) Access Read-only Table 939. Physical Memory Array Error Checking and Correcting (ECC) Type Name physicalMemoryArrayECCType Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.7 Description Defines the ECC type used by the physical memory array. Syntax DellPhysicalMemoryArrayECCType (See Physical Memory Array ECC Type Definitions) Access Read-only Table 940.
Table 943. Physical Memory Array In Use Number Sockets Name physicalMemoryArrayInUseNumberSockets Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.11 Description Defines the total number of memory sockets in use by the physical memory array. Syntax DellUnsigned32BitRange Access Read-only Table 944. Physical Memory Array ECC Error Nonrecoverable Threshold Name physicalMemoryArrayECCErrorNonRecoverbeThreshold Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.
Syntax DellObjectRange Access Read-only Table 948. Physical Memory Array Extended Maximum Size NOTE: This attribute replaces the physicalMemoryArrayMaximumSize. Name physicalMemoryArrayExtendedMaximumSize Object ID 1.3.6.1.4.1.674.10892.1.1300.10.1.16 Description This attribute defines the maximum size in Bytes of the physical memory array. Syntax DellUnsigned64BitRange Access Read-only Physical Memory Array Mapped Table The physical memory array is divided into memory array mapped addresses.
Syntax DellObjectRange Access Read-only Table 952. Physical Memory Array Mapped Index Name physicalMemoryArrayMappedIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.2 Description Defines the index (one-based) of the memory array mapped address in this chassis. Syntax DellObjectRange Access Read-only Table 953. Physical Memory Array Mapped State Capabilities Name physicalMemoryArrayMappedStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.
Syntax DellObjectRange Access Read-only Table 957. Physical Memory Array Mapped Starting Address Name physicalMemoryArrayMappedStartingAddress Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.7 Description Defines the physical starting address in KB of the memory array mapped address. Syntax DellUnsigned64BitRange Access Read-only Table 958. Physical Memory Array Mapped Ending Address Name physicalMemoryArrayMappedEndingAddress Object ID 1.3.6.1.4.1.674.10892.1.1300.20.1.
Access Not accessible Table 961. Physical Memory Configuration Table Entry Name physicalMemoryConfigTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1 Description Defines the Physical Memory Configuration Table entry. Syntax PhysicalMemoryConfigTableEntry Access Not accessible Index physicalMemoryConfigChassisIndex , physicalMemoryConfigIndex Table 962. Physical Memory Configuration Chassis Index Name physicalMemoryConfigChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.
Table 965. Physical Memory Configuration State Settings Name physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4 Description Defines the state settings of the physical memory configuration. Syntax DellPhysicalMemoryConfigStateSettings Access Read-only Table 966. Physical Memory Configuration Status Name physicalMemoryConfigStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.5 Description Defines the status of the physical memory configuration.
Table 970. Physical Memory Configuration MOM Settings Name physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9 Description Defines the Memory Operating Mode settings of the physical memory. Syntax DellPhysicalMemoryConfigMOMSettings Access Read-only Physical Memory Logging Table This table defines the conditions for logging system memory events. The following object sets up the Physical Memory Logging Table: Table 971.
Description Defines the index (one-based) of the physical memory logging. Syntax DellObjectRange Access Read-only Table 975. Physical Memory Logging Capabilities Name physicalMemoryLoggingCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1300.40.1.3 Description Defines the capabilities of the physical memory logging. Syntax DellPhysicalMemoryLoggingCapabilities Access Read-only Table 976. Physical Memory Logging Settings Name physicalMemoryLoggingSettings Object ID 1.3.6.1.4.1.674.10892.1.
Description Defines the Redundant Memory Unit Table entry. Syntax RedundantMemoryUnitTableEntry Access Not accessible Index redundantMemoryUnitChassisIndex , redundantMemoryUnitIndex Table 980. Redundant Memory Unit Chassis Index Name redundantMemoryUnitChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.1 Description Defines the index (one-based) of the chassis associated with the redundant memory unit. Syntax DellObjectRange Access Read-only Table 981.
Table 984. Redundant Memory Unit Redundancy Status Name redundantMemoryUnitRedundancyStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5 Description Defines the redundancy status of the redundant memory unit. Syntax DellStatusRedundancy Access Read-only Table 985. Redundant Memory Unit Name Name redundantMemoryUnitName Object ID 1.3.6.1.4.1.674.10892.1.1300.50.1.6 Description Defines the name of the redundant memory unit. Syntax DellString Access Read-only Table 986.
Syntax PhysicalMemoryCardTableEntry Access Not accessible Index physicalMemoryCardChassisIndex , physicalMemoryCardIndex Table 989. Physical Memory Card Chassis Index Name physicalMemoryCardChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 990. Physical Memory Card Index Name physicalMemoryCardIndex Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.
Table 993. Physical Memory Card Status Name physicalMemoryCardStatus Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.5 Description Defines the status of the Physical Memory Card. Syntax DellStatus Access Read-only Table 994. Physical Memory Card Name Name physicalMemoryCardName Object ID 1.3.6.1.4.1.674.10892.1.1300.60.1.6 Description Defines the name of the Physical Memory Card. Syntax DellString Access Read-only Table 995.
Syntax DellObjectRange Access Read-only Memory Group Variable Values This section includes definitions for server administrator-specific variable values used in this section. Table 998. Physical Memory Array Location Variable Name: DellPhysicalMemoryArrayLocation Data Type: Integer Possible Data Values Meaning of Data Value memoryArrayLocationIsOther(1) The memory array location is not one of the following: memoryArrayUseIsUnknown(2) The memory array use is unknown.
Possible Data Values Meaning of Data Value memoryArrayECCTypeIsOther(1) There is not one of the following: memoryArrayECCTypeIsUnknown(2) The memory array ECC type is unknown. memoryArrayECCTypeIsNone(3) The memory array ECC type is none. memoryArrayECCTypeIsParity(4) The memory array ECC type is parity. memoryArrayECCTypeIsSingleBitECC(5) The memory array ECC type is Correctable Memory Event ECC. memoryArrayECCTypeIsMultiBitECC(6) The memory array ECC type is Uncorrectable Memory Event ECC.
If set to 0 (zero) There are no redundant memory capabilities. unknownCapabilities(1) Redundant capabilities are unknown. The redundant capabilities are: spareCapable(2) Spare redundant memory feature is supported. mirrorCapable(4) Mirror redundant memory feature is supported. spareAndMirrorCapable(6) Spare and mirror redundant memory features are supported. raidCapable(8) Redundant Array of Independent disks (RAID) redundant memory feature is supported.
If set to 0 (zero) There are no logging settings enabled. unknown Capabilities(1) Logging capabilities are unknown. The logging settings are: enabled(2) Logging is disabled (0), or enabled (1). BIOS Setup Control Group Basic Input/Output System (BIOS) Setup Control Group variables provide information about the functions that the BIOS performs in your system.
Syntax BiosSetUpControlTableEntry Access Not accessible Index biosSetUpControlchassisIndex Table 1008. BIOS Setup Control Chassis Index Name biosSetUpControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1009. BIOS Setup Control (BSUC) Pointing Device Control Capabilities Name bSUCpointingDeviceControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Syntax DellString Access Read-only Table 1013. BIOS Setup Control Numeric Lock Control Capabilities Name bSUCnumLockControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.6 Description Defines the capabilities of the numeric lock. Syntax DellStateCapabilities Access Read-only Table 1014. BIOS Setup Control Numeric Lock Control Settings Name bSUCnumLockControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.7 Description Defines the state of the numeric lock.
Access Read-only Table 1018. BIOS Setup Control Processor Serial Number Control Settings Name bSUCprocessorSerialNumberControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.11 Description Defines the state of the processor serial number. Syntax DellStateSettings Access Read-only Table 1019. BIOS Setup Control Processor Serial Number Control Status Name bSUCprocessorSerialNumberControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Access Read-only Table 1023. BIOS Setup Control Speaker Control Status Name bSUCspeakerControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16 Description Defines the status of speaker control. Syntax DellStatus Access Read-only Table 1024. BIOS Setup Control Speaker Control Name Name bSUCspeakerControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.17 Description Defines the setup BIOS name of the speaker control. Syntax DellString Access Read-only Table 1025.
Syntax DellStatus Access Read-only Table 1028. BIOS Setup Control NIF Wakeup on LAN Control Name Name bSUCnIFwakeonLanControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.21 Description Defines the setup BIOS name of the NIF Wakeup on LAN. Syntax DellString Access Read-only Table 1029. BIOS Setup Control Boot Sequence Control Capabilities Unique Name bSUCbootSequenceControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.
Syntax DellString Access Read-only Table 1033. BIOS Setup Control Administrator Password Control Capabilities Unique Name bSUCadministratorPasswordControlCapabilities Unique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.26 Description Defines the capabilities of the administrator password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only Table 1034.
current administrator password immediately preceding this password change. Syntax DellString Access Read-only Table 1038. BIOS Setup Control User Password Control Capabilities Unique Name bSUCuserPasswordControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.31 Description Defines the capabilities of user password control. Syntax DellBIOSPasswordControlCapabilitiesUnique Access Read-only Table 1039.
Description Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user password immediately preceding this password change. Syntax DellString Access Read-Only Table 1043. BIOS Setup Control TPM Security Control Capabilities Name bSUCtpmSecurityControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.10.1.36 Description Defines the BIOS setup control capabilities of Trusted Platform Module (TPM) security.
SCSI Control Table Table 1047. SCSI Control Table Name sCSIControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.20 Description Defines the Small Computer System Interface (SCSI) Control Table. Syntax SCSIControlTableEntry Access Not accessible Table 1048. SCSI Control Table Entry Name sCSIControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1 Description x Defines the SCSI Control Table entry.
Access Read-only Table 1052. SCSI Control Settings Name sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4 Description Defines the state of the SCSI controller. Syntax DellStateSettings Access Read-only Table 1053. SCSI Control Status Name sCSIControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.5 Description Defines the status of the SCSI controller. Syntax DellStatus Access Read-only Table 1054. SCSI Control Name Name sCSIControlName Object ID 1.3.6.1.4.1.
, parallelPortControlIndex Table 1057. Parallel Port Control Chassis Index Name parallelPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1058. Parallel Port Control Index Name parallelPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.2 Description Defines the index (one-based) of the parallel port in this chassis.
Access Read-only Table 1062. Parallel Port Control Name Name parallelPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6 Description Defines the setup BIOS name of the parallel port. Syntax DellString Access Read-only Table 1063. Parallel Port Control Mode Capabilities Unique Name parallelPortControlModeCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.30.1.7 Description Defines the mode capabilities of the parallel port.
, serialPortControlIndex Table 1067. Serial Port Control Chassis Index Name serialPortControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1 Description Defines index (one-based) of this chassis. Syntax DellObjectRange Access read-only Table 1068. Serial Port Control Index Name serialPortControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.2 Description Defines the index (one-based) of the serial port in this chassis. Syntax DellObjectRange Access read-only Table 1069.
Table 1072. Serial Port Control Name Name serialPortControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6 Description Defines the setup BIOS name of the serial port. Syntax DellString Access Read-only USB Control Table These objects enable you to track the attributes of your Universal Serial Bus (USB). Table 1073. USB Control Table Name usbControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.50 Description Defines the USB Table.
Access Read-only Table 1077. USB Control Capabilities Name usbControlCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3 Description Defines the capabilities of the USB. Syntax DellStateCapabilities Access Read-only Table 1078. USB Control Settings Name usbControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.50.1.4 Description Defines the control settings for the USB. Syntax DellStateSettings Access Read-only Table 1079.
Access Not accessible Table 1082. IDE Control Table Entry Name ideControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1 Description Defines the IDE Control Table entry. Syntax IdeControlTableEntry Access Not accessible Index ideControlchassisIndex , ideControlIndex Table 1083. IDE Control Chassis Index Name ideControlchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.1 Description Defines the index (one-based) of this chassis.
Access Read-only Table 1087. IDE Control Status Name ideControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5 Description Defines the status for the IDE controller. Syntax DellStatus Access Read-only Table 1088. IDE Control Name Name ideControlName Object ID 1.3.6.1.4.1.674.10892.1.1400.60.1.6 Description Defines the setup BIOS name for the IDE controller. Syntax DellStatus Access Read-only Diskette Control Table Table 1089.
Access Read-only Table 1092. Diskette Control Index Name disketteControlIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2 Description Defines the index of the diskette controllers in this chassis. Syntax DellObjectRange Access Read-only Table 1093. Diskette Control Capabilities Unique Name disketteControlCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.70.1.3 Description Defines the capabilities of the diskette controller.
Table 1097. Network Interface Control Table Name networkInterfaceControlTable Object ID 1.3.6.1.4.1.674.10892.1.1400.80 Description Defines the Network Interface Control Table. Syntax NetworkInterfaceControlTableEntry Access Not accessible Table 1098. Network Interface Control Table Entry Name networkInterfaceControlTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1 Description Defines the Network Interface Control Table entry.
Access Read-only Table 1102. Network Interface Control Settings Unique Name networkInterfaceControlSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.4 Description Defines the control settings for the NIC. Syntax DellNetworkInterfaceControlSettingsUnique (See Network Interface Control Settings) Access Read-only Table 1103. Network Interface Control Status Name networkInterfaceControlStatus Object ID 1.3.6.1.4.1.674.10892.1.1400.80.1.5 Description Defines the status of the NIC.
Syntax BiosSettingTableEntry Access Not accessible Index biosSettingChassisIndex , biosSettingIndex Table 1107. BIOS Setting Chassis Index Name biosSettingChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.1 Description Defines the index (one based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1108. BIOS Setting Index Name biosSettingIndex Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.2 Description Defines the index (one based) of the BIOS setting.
Syntax DellBIOSSettingValueType Access Read-only Table 1112. BIOS Setting Current Value Name biosSettingCurrentValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.6 Description Defines the current value of the BIOS setting. Syntax DisplayString Access Read-only Table 1113. BIOS Setting Pending Value Name biosSettingPendingValue Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.7 Description Defines the pending value of the BIOS setting. Syntax DisplayString Access Read-only Table 1114.
Table 1117. BIOS Setting Group Display Name Name biosSettingGroupDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.11 Description Defines the display name of the BIOS setting group for the BIOS setting. Syntax DisplayString Access Read-only Table 1118. BIOS Setting FQDD Name biosSettingFQDD Object ID 1.3.6.1.4.1.674.10892.1.1400.90.1.12 Description Fully Qualified Device Descriptor (FQDD) for the BIOS setting.
medium(8) Speaker control volume is medium. high(16) Speaker control volume is high. Table 1121. Network Interface (NIF) Wakeup on LAN Capabilities Unique Variable Name: DellNIFwakeonLanControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS Wakeup on LAN capabilities are unknown. enableCapable(2) Setup BIOS is capable of enabling the NIF Wakeup on LAN. addInCardCapable(4) Setup BIOS is capable of enabling Wakeup on LAN by option card.
bootFromDisketteORHardDrive FirstCapable(6) Setup BIOS can boot from a diskette or an IDE hard drive first. bootFromDeviceListCapable(8) Setup BIOS can boot from a device list. bootFromCDROMFirstCapable(16) Setup BIOS can boot from a CD first. allFirstCapable(30) Setup BIOS can boot by any of the preceding methods first. Table 1124.
passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper. Table 1127. BIOS Password Control Settings Variable Name: DellBIOSPasswordControlSettingsUnique Data Type: Integer Possible Data Values Meaning of Data Value passwordControlSettingsUnknown(1) Setup BIOS password state is unknown. passwordControlEnabled(2) Setup BIOS has password changes enabled.
lpt1Capable(4) Setup BIOS can support parallel port 1. lpt1andEnableCapable(6) Setup BIOS has enabled parallel port 1. lpt2Capable(8) Setup BIOS can support parallel port 2. lpt2andEnableCapable(10) Setup BIOS has enabled parallel port 2. lpt3Capable(16) Setup BIOS can support parallel port 3. lpt3andEnableCapable(18) Setup BIOS has enabled parallel port 3. allParallelPortCapable(30) Setup BIOS can support any of the three parallel ports. Table 1131.
Table 1133. Serial Port Control Capabilities Variable Name: DellSerialPortControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Setup BIOS serial port capabilities are unknown. enableCapable(2) Setup BIOS can enable the serial port. com1Capable(4) Setup BIOS can support serial port 1. enableAndCom1Capable(6) Setup BIOS can enable serial port 1. com2Capable(8) Setup BIOS can support serial port 2.
com4(32) Setup BIOS has selected serial port 4. com4Enabled(34) Setup BIOS has enabled serial port 4. comPortsAutoConfig(64) Setup BIOS has selected autoconfiguration of serial ports. enabledAndAutoConfig(66) Setup BIOS has enabled autoconfiguration of serial ports. Table 1135. IDE Control Capabilities Variable Name: DellideControlCapabilitiesUnique Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) IDE control capabilities are unknown.
unknown(1) Network interface state is unknown. enabled(2) Network interface is enabled. enabledWithoutPXE(4) Network interface is enabled without PXE. Table 1139. BIOS Setting Value Type Variable Name: DellBIOSSettingValueType Data Type: Integer Possible Data Values Meaning of Data Value integer(1) Value type is integer. string(2) Value type is string. enumeration(3) Value type is enumeration. orderedList(4) Value type is ordered list.
Description Defines the LRA Global Settings Table. Syntax SEQUENCE OF LRAGlobalSettingsTableEntry Access Not accessible Table 1141. LRA Global Settings Table Entry Name lRAGlobalSettingsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1 Description Defines the LRA Global Settings Table entry. Syntax LRAGlobalSettingsTableEntry Access Not accessible Index lRAGlobalchassisIndex Table 1142. LRA Global Chassis Index Name lRAGlobalchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.10.
Table 1145. LRA Global Settings Capabilities Unique Name lRAGlobalSettingsCapabilitiesUnique Object ID 1.3.6.1.4.1.674.10892.1.1500.10.1.4 Description Defines the set of global capabilities that all local response agents may or may not allow to be set or reset. Syntax DellLocalResponseAgentCapabilitiesUnique (LRA Capabilities Definitions) Access Read-only Table 1146. LRA Global Thermal Shutdown Capabilities Unique Name lRAGlobalThermalShutdownCapabilitiesUnique Object ID 1.3.6.1.4.1.674.
Table 1149. LRA Action Table Entry Name lRAActionTableTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1 Description Defines the LRA Action Table entry. Syntax LRAActionTableTableEntry Access Not accessible Index lRAActionTablechassisIndex , lRAActionTableActionNumberIndex Table 1150. LRA Action Table Chassis Index Name lRAActionTablechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.1 Description Defines the index (one-based) of this chassis.
• • • • • 1554 — log full action definition 1603 — processor warning action definition 1604 — processor failure action definition 1703 — battery warning action definition 1704 — battery failure action definition Syntax DellUnsigned16BitRange Access Read-only Table 1152. LRA Action Table User Application Name Name lRAActionTableUserApplicationName Object ID 1.3.6.1.4.1.674.10892.1.1500.20.1.
rebootCapable(16) The LRA can reboot the system. powerCycleCapable(32) The LRA is capable of a system power cycle. powerOFFCapable(64) The LRA can shut the system power off. executeApplicationCapable(256) The LRA can execute a user mode application. lraFullyCapable(383) The LRA has all of the preceding capabilities. Table 1155.
powerOFF(64) LRA is set to issue a system power off. executeApplication(256) LRA is set to start a user mode application. allLRASettingsUnique(383) LRA is set to all LRA settings combinations. Cost of Ownership Group The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others.
Access Not accessible Index coochassisIndex Table 1159. COO Chassis Index Name coochassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1 Description Defines the index (one-based) of this chassis. Syntax CooTableEntry Access Read-only Table 1160. COO State Name cooState Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.2 Description Defines the acquisition state of the system. Syntax DellStateSettings Access Read-only Table 1161.
Access Read-only Table 1164. COO Acquisition Purchase Order Name cooAquisitionPurchaseOrder Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.6 Description Defines the purchase order number of the system. Syntax DellUnsigned32BitRange Access Read-only Table 1165. COO Acquisition Purchase Date Name Name cooAquisitionPurchaseDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.7 Description Defines the purchase date and time of the system. Syntax DellDateName Access Read-only Table 1166.
Access Read-only Table 1169. COO Cost Center Information Vendor Name Name cooCostCenterInformationVendorName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.11 Description Defines the cost center name of the system. Syntax DellCostofOwnershipString Access Read-only Table 1170. COO User Information User Name Name cooUserInformationUserName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.12 Description Defines the name of the user for this system.
Access Read-only Table 1174. COO Extended Warranty Provider Name Name cooExtendedWarrantyProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16 Description Defines the name of the extended warranty provider for this system. Syntax DellCostofOwnershipString Access Read-only Table 1175. COO Ownership Code Name cooOwnershipCode Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.17 Description Defines the ownership code for this system.
Access Read-only Table 1179. COO Deployment Duration Type Name cooDeploymentDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21 Description Defines the deployment time units for this system. Syntax DellCooHourDayDurationType (See COO Hour Day Duration Type) Access Read-only Table 1180. COO Training Name Name cooTrainingName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.22 Description Defines the training that the user has for this system.
Access Read-only Table 1184. COO Outsourcing Provider Fee Name Name cooOutsourcingProviderFeeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26 Description Defines any additional outsourcing charge for service. Syntax DellCostofOwnershipString Access Read-only Table 1185. COO Outsourcing Provider Service Level Name Name cooOutsourcingProviderServiceLevelName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.27 Description Defines the service level agreement for the system.
Access Read-only Table 1189. COO Box Central Processing Unit (CPU) Serial Number Name Name cooBoxCPUSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.31 Description Defines the name of the CPU serial number for the system. Syntax DellCostofOwnershipString Access Read-only Table 1190. COO Operating System Upgrade Type Name Name cooOperatingSystemUpgradeTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.32 Description Defines the name of the operating system on this system.
Access Read-only Table 1194. COO Depreciation Duration Type Name cooDepreciationDurationType Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36 Description Defines the unit of time for the depreciation of this system. Syntax DellCooMonthYearDurationType Access Read-only Table 1195. COO Depreciation Percentage Name cooDepreciationPercentage Object ID 1.3.6.1.4.1.674.10892.1.1600.10.1.37 Description Defines the percentage of depreciation for this system.
Description Defines the COO Service Contract Table. Syntax SEQUENCE OF CooServiceContractTableEntry Access Not accessible Table 1199. COO Service Contract Table Entry Name cooServiceContractTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1 Description Defines the COO Service Contract Table entry. Syntax CooServiceContractTableEntry Access Not accessible Index cooServiceContractchassisIndex , cooServiceContractIndex Table 1200.
Table 1203. COO Service Contract Was Renewed Name cooServiceContractWasRenewed Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4 Description Specifies whether the service contract for this system was renewed. Syntax DellBoolean Access Read-only Table 1204. COO Service Contract Type Name Name cooServiceContractTypeName Object ID 1.3.6.1.4.1.674.10892.1.1600.20.1.5 Description Defines the name of the service contract type for this system.
Access Not accessible Index cooCostEventLogchassisIndex , cooCostEventLogIndex Table 1208. COO Cost Event Log Chassis Index Name cooCostEventLogchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1209. COO Cost Event Log Index Name cooCostEventLogIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.2 Description Defines the index (one-based) of the cost event log.
Description Defines the duration type of the event for this system. Syntax DellCOOHourDayDurationType (See COO Hour Day Duration Type) Access Read-only Table 1213. COO Cost Event Log Description Name Name cooCostEventLogDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1600.30.1.6 Description Defines the name of the event description.
Access Read-only Table 1217. COO Warranty Index Name cooWarrantyIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.2 Description Defines the index of the warranty for this system. Syntax DellObjectRange Access Read-only Table 1218. COO Warranty State Name cooWarrantyState Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.3 Description Defines the state of the warranty for this system. Syntax DellStateSettings Access Read-only Table 1219.
Access Read-only Table 1222. COO Warranty Cost Name cooWarrantyCost Object ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7 Description Defines the cost of the warranty for this system. Syntax DellUnsigned32BitRange Access Read-only COO Lease Information Table The COO lease information MIB objects enable you to track information about your lessor, lease duration, and lease type for each system. Table 1223. COO Lease Information Table Name cooLeaseInformationTable Object ID 1.3.6.1.4.1.674.10892.1.
Table 1226. COO Lease Information Index Name cooLeaseInformationIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2 Description Defines the index of the lease information for this system. Syntax DellObjectRange Access Read-only Table 1227. COO Lease Information State Name cooLeaseInformationState Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.3 Description Defines the lease information state for this system. Syntax DellStateSettings Access Read-only Table 1228.
Table 1231. COO Lease Information End Date Name Name cooLeaseInformationEndDateName Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7 Description Defines the end date for the lease on this system. Syntax DellDateName Access Read-only Table 1232. COO Lease Information Fair Market Value Name cooLeaseInformationFairMarketValue Object ID 1.3.6.1.4.1.674.10892.1.1600.50.1.8 Description Defines the fair market value of this system. Syntax DellUnsigned32BitRange Access Read-only Table 1233.
, cooScheduleNumberIndex Table 1236. COO Schedule Number Chassis Index Name cooScheduleNumberchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1237. COO Schedule Number Index Name cooScheduleNumberIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.60.1.2 Description Defines the index of the schedule number information. Syntax DellObjectRange Access Read-only Table 1238.
Syntax DellCostofOwnershipString Access Read-only COO Options Table Table 1241. COO Options Table Name cooOptionsTable Object ID 1.3.6.1.4.1.674.10892.1.1600.70 Description Defines the COO Options Table. Syntax SEQUENCE OF CooOptionsTableEntry Access Not accessible Table 1242. COO Options Table Entry Name cooOptionsTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1 Description Defines the COO Options Table entry.
Table 1245. COO Options State Name cooOptionsState Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.3 Description Defines the option information state for this system. Syntax DellStateSettings Access Read-only Table 1246. COO Options Lease Information Index Reference Name cooOptionsLeaseInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.70.1.4 Description Defines the lease information index of the option information for this system.
Index cooMaintenancechassisIndex , cooMaintenanceIndex Table 1250. COO Maintenance Chassis Index Name cooMaintenancechassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1251. COO Maintenance Index Name cooMaintenanceIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.2 Description Defines the index of this system’s maintenance information.
Syntax DellDateName Access Read-only Table 1255. COO Maintenance Provider Name Name cooMaintenanceProviderName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.6 Description Defines the maintenance provider’s name. Syntax DellStateSettings Access Read-only Table 1256. COO Maintenance Restrictions Name Name cooMaintenanceRestrictionsName Object ID 1.3.6.1.4.1.674.10892.1.1600.80.1.7 Description Defines the maintenance agreement restrictions.
Table 1259. COO Repair Chassis Index Name cooRepairchassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1 Description Defines the index (one-based) of this chassis. Syntax DellObjectRange Access Read-only Table 1260. COO Repair Index Name cooRepairIndex Object ID 1.3.6.1.4.1.674.10892.1.1600.90.1.2 Description Defines the index (one-based) of the repair information for this system. Syntax DellObjectRange Access Read-only Table 1261.
COO Support Information Table Table 1264. COO Support Information Table Name cooSupportInformationTable Object ID 1.3.6.1.4.1.674.10892.1.1600.100 Description Defines the COO Support Information Table. Syntax SEQUENCE OF cooSupportInformationTableEntry Access Not accessible Table 1265. COO Support Information Table Entry Name cooSupportInformationTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1 Description Defines the COO Support Information Table entry.
Description Defines the support information state for this system. Syntax DellStateSettings Access Read-only Table 1269. COO Support Information Is Outsourced Name cooSupportInformationIsOutsourced Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.4 Description Specifies whether the support for this system is outsourced or not. Syntax DellBoolean Access Read-only Table 1270. COO Support Information Type Name cooSupportInformationType Object ID 1.3.6.1.4.1.674.10892.1.1600.100.1.
Table 1273. COO Trouble Ticket Table Name cooTroubleTicketTable Object ID 1.3.6.1.4.1.674.10892.1.1600.110 Description Defines the COO Trouble Ticket Table. Syntax SEQUENCE OF cooTroubleTicketTableEntry Access Not accessible Table 1274. COO Trouble Ticket Table Entry Name cooTroubleTicketTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1 Description Defines the COO Trouble Ticket Table entry.
Access Read-only Table 1278. COO Trouble Ticket Support Information Index Reference Name cooTroubleTicketSupportInformationIndexReference Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.4 Description Defines the support information index that references the trouble ticket. Syntax DellUnsigned32BitRange Access Read-only Table 1279. COO Trouble Ticket Number Name Name cooTroubleTicketNumberName Object ID 1.3.6.1.4.1.674.10892.1.1600.110.1.
unknown(1) Duration time type is unknown. hours(2) Duration time type is in hours. days(3) Duration time type is in days. Table 1282. COO Day Month Duration Type Variable Name: DellCooDayMonthDurationType Data Type: Integer Possible Data Values Meaning of Data Value unknown(1) Duration time type is unknown. days(3) Duration time type is in days. months(4) Duration time type is in months. Table 1283.
Access Not accessible Table 1285. Remote Access Table Entry Name remoteAccessTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1 Description Defines the Remote Access Table entry. Syntax RemoteAccessTableEntry Access Not accessible Index remoteAccessChassisIndex , remoteAccessAdapterIndex Table 1286. Remote Access Chassis Index Name remoteAccessChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Access Read-only Table 1290. Remote Access State Settings Name remoteAccessStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5 Description Defines the state setting of the remote access hardware. Syntax DellStateSettings Access Read-only Table 1291. Remote Access Status Name remoteAccessStatus Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.6 Description Defines the status of the remote access hardware. Syntax DellStatus Access Read-only Table 1292.
Table 1295. Remote Access Local Area Network (LAN) Capabilities Name remoteAccessLANCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14 Description Defines the LAN capabilities of the remote access hardware. Syntax DellRemoteAccessLANCapabilities (Remote Access Local Area Network (LAN) Capabilities) Access Read-only Table 1296. Remote Access LAN Settings Name remoteAccessLANSettings Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Table 1300. Remote Access Personal Computer Memory Card International Association (PCMCIA) Info Name Name remoteAccessPCMCIAInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.28 Description Defines the information for the PCMCIA device used by the remote access hardware. Syntax DisplayString Access Read-only Table 1301. Remote Access Miscellaneous Information Name Name remoteAccessMiscInfoName Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.
Table 1305. Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP) Name remoteAccessNICCurrentInfoFromDHCP Object ID 1.3.6.1.4.1.674.10892.1.1700.10.1.33 Description Defines whether DHCP was used to obtain the NIC information currently being used by the integrated NIC provided by the remote access hardware. Syntax DellBoolean Access Read-only Table 1306. Remote Access Remote Connect URL Name remoteAccessRemoteConnectURL Object ID 1.3.6.1.4.1.674.10892.1.1700.10.
logResetCapable( 2) The remote access hardware can reset its integrated logs. hardResetCapabl e(4) The remote access hardware can perform a hard reset. softResetCapabl e(8) The remote access hardware can perform a soft reset. gracefulResetCap able(16) The remote access hardware can gracefully shut down and perform a soft reset. defaultConfigRes etCapable(32) The remote access hardware can reset to its default settings. shutdownCapable( 64) The remote access hardware can shut down. Table 1309.
extPwrSupplyMoni torIfConn ectedCapable(2) The remote access hardware can be set to monitor the external power supply, if connected. extPwrSupplyMoni torAlways EnabledCapable(4 ) The remote access hardware can be set to always monitor the external power supply. Table 1311. Remote Access Monitor Settings Variable Name:DellRemoteAccessMonitorSettings Data Type:Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no monitor settings.
unknown(1) The remote access hardware LAN settings are unknown. nicEnabled(2) The remote access hardware NIC is enabled. nicDHCPEnabled(4 ) The remote access hardware NIC uses DHCP to obtain an IP address. Table 1314. Remote Access Host Capabilities Variable Name:DellRemoteAccessHostCapabilities Data Type:Integer Possible Data Values Meaning of Data Value none(0) The remote access hardware has no host capabilities. unknownCapabilit ies(1) The remote access hardware host capabilities are unknown.
unknownCapabilit ies(1) The remote access hardware out-of-band SNMP capabilities are unknown. oobSNMPAgentCapa ble(2) The remote access hardware has an out-ofband SNMP agent. oobSNMPTrapsCapa ble(4) The remote access hardware can send outof-band SNMP traps. Table 1317.
none(0) The admin user has no state settings. unknown(1) The admin user state settings are unknown. enabled(2) The admin user is enabled. notReady(4) The admin user is in the not ready state. numericPagerEnab led(8) Numeric paging is enabled for the admin user. alphaPagerEnable d(16) Alphanumeric paging is enabled for the admin user. emailEnabled(32) E-mail is enabled for the admin user. Table 1320.
other(1) The remote user admin alpha protocol type is not one of the following: unknown(2) The remote user admin alpha protocol type is unknown. alpha7E0(3) The remote user admin alpha protocol type is 7E0. alpha8N1(4) The remote user admin alpha protocol type is 8N1. Table 1323.
enabled(2) The SNMP trap destination is enabled. notReady(4) The SNMP trap destination is in the not ready state. Table 1326. Remote SNMP Trap Control Capabilities Variable Name:DellRemoteSNMPTrapControlCapabilities Data Type:Integer Possible Data Values Meaning of Data Value none(0) The SNMP trap destination has no control capabilities. unknownCapabilit ies(1) The SNMP trap destination control capabilities are unknown.
dialInDHCPCapabl e(32) The dial-up functionality can support using DHCP to obtain an IP address for the dial-in feature. dialInAuthAnyCap able(64) The dial-up functionality can support any authentication type (including clear text) for the dial-in feature. dialInAuthEncryp tedCapable(128) The dial-up functionality can support encrypted passwords (CHAP) authentication for the dial-in feature.
remoteDialUpIsOt her(1) The remote dial type is not one of the following: remoteDialUpIsUn known(2) The remote dial type is unknown. remoteDialUpIsTo ne(3) The remote dial type is tone. remoteDialUpIsPu lse(4) The remote dial type is pulse. Table 1331. Remote User Dial-In State Capabilities Variable Name:DellRemoteUserDialInStateCapabilities Data Type:Integer Possible Data Values Meaning of Data Value none(0) The dial-in user has no state capabilities.
Data Type:Integer Possible Data Values Meaning of Data Value none(0) The dial-out destination has no state capabilities. unknownCapabilit ies(1) The dial-out destination state capabilities are unknown. enableCapable(2) The dial-out destination can be disabled or enabled. notReadyCapable( 4) The dial-out destination can be in the not ready state. dialOutPPPAuthAn yCapable(8) The dial-out destination can support any authentication type (including clear text) for PPP.
systems. Simpler management is achieved by using virtual servers, as opposed to managing each individual computer system. Cluster Group The Cluster Group defines attributes such as the number of systems in the cluster, capabilities of the cluster, type of cluster, and name of the cluster. Cluster Table The following table defines the attributes of the cluster. Table 1335. Cluster Table Name clusterTable Object ID 1.3.6.1.4.1.674.10892.1.1800.10 Description Defines the Cluster Table.
Access Read-only Table 1339. Cluster State Capabilities Name clusterStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.3 Description Defines the state capabilities of the cluster. Syntax DellStateCapabilities Access Read-only Table 1340. Cluster State Settings Name clusterStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.4 Description Defines the state settings of the cluster. Syntax DellStateSettings Access Read-only Table 1341.
Table 1344. Cluster Name Name clusterName Object ID 1.3.6.1.4.1.674.10892.1.1800.10.1.8 Description Defines the name of the cluster. Syntax DellString Access Read-only Cluster Group Variable Values This section includes definitions for Server Administrator-specific variable values used in this section. Table 1345. Cluster Type Variable Name:DellClusterType Data Type:Integer Possible Data Values Meaning of Data Value unknown(1) The cluster type is unknown.
Syntax SEQUENCE OF BmcTableEntry Access Not accessible Table 1347. BMC Table Entry Name bmcTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1 Description Defines the Baseboard Management Controller (BMC) Table Entry. Syntax BmcTableEntry Access Not accessible Index bmcChassisIndex , bmcIndex Table 1348. BMC Chassis Index Name bmcChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.1 Description Defines the index (one-based) of the associated chassis.
Syntax DellStateSettings Access Read-only Table 1352. BMC Status Name bmcStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5 Description Defines the status of the BMC. Syntax DellStatus Access Read-only Table 1353. BMC Display Name Name bmcDisplayName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.6 Description Defines the display name of the BMC. Syntax DellString Access Read-only Table 1354. BMC Description Name Name bmcDescriptionName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.
Table 1357. BMC Type Name bmcType Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.10 Description Defines the type of the BMC. Syntax DellManagementControllerType Access Read-only Table 1358. BMC Module Name Name bmcModuleName Object ID 1.3.6.1.4.1.674.10892.1.1900.10.1.11 Description Defines the module name for the BMC. The module name is present only on certain systems, such as modular systems. Syntax DellString Access Read-only Table 1359.
Baseboard Management Controller Serial Interface Table 1362. BMC Serial Interface Table Name bmcSerialInterfaceTable Object ID 1.3.6.1.4.1.674.10892.1.1900.20 Description Defines the BMC Serial Interface Table. Syntax SEQUENCE OF BmcSerialInterfaceTableEntry Access Not accessible Table 1363. BMC Serial Interface Table Entry Name bmcSerialInterfaceTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1 Description Defines the BMC Serial Interface Table Entry.
Syntax DellObjectRange Access Read-only Table 1367. BMC Serial Interface State Capabilities Name bmcSerialInterfaceStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.4 Description Defines the state capabilities of the BMC serial interface. Syntax DellStateCapabilities Access Read-only Table 1368. BMC Serial Interface State Settings Name bmcSerialInterfaceStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.
Table 1372. BMC Serial Interface Connection Mode Settings Name bmcSerialInterfaceConnectionModeSettings Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.9 Description Defines the connection mode settings of the BMC serial interface. Syntax DellBMCSerialConnectionModeSettings Access Read-only Table 1373. BMC Serial Interface Flow Control Name bmcSerialInterfaceFlowControl Object ID 1.3.6.1.4.1.674.10892.1.1900.20.1.10 Description Defines the flow control type of the BMC serial interface.
, bmcLANInterfaceBMCIndex , bmcLANInterfaceIndex Table 1377. BMC LAN Interface Chassis Index Name bmcLANInterfaceChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.1 Description Defines the index (one-based) of the associated chassis. Syntax DellObjectRange Access Read-only Table 1378. BMC LAN Interface BMC Index Name bmcLANInterfaceBMCIndex Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.2 Description Defines the index (one-based) of the associated BMC.
Access Read-only Table 1382. BMC LAN Interface Status Name bmcLANInterfaceStatus Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.6 Description Defines the status of the BMC LAN interface. Syntax DellStatus Access Read-only Table 1383. BMC LAN Interface Channel Number Name bmcLANInterfaceChannelNumber Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.7 Description Defines the BMC channel number of the BMC LAN interface. Syntax DellUnsigned8BitRange Access Read-only Table 1384.
Table 1387. BMC LAN Interface Default Gateway Address Name bmcLANInterfaceDefaultGatewayAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.11 Description Defines the IP address of the default gateway for the BMC LAN interface. Syntax IpAddress Access Read-only Table 1388. BMC LAN Interface MAC Address Name bmcLANInterfaceMACAddress Object ID 1.3.6.1.4.1.674.10892.1.1900.30.1.12 Description Defines the MAC address of the BMC LAN interface.
directPPP(16) BMC serial interface supports Direct PPP mode. directTerminal(32) BMC serial interface supports Direct Terminal mode. Table 1391. BMC Serial Connection Mode Settings Variable Name:DellBMCSerialConnectionModeSettingsDellBMCSeria lConnectionModeCapabilities Data Type:Integer These values are bit masks; therefore, combination values are possible. Possible Data Values Meaning of Data Value -- none(0) No modes enabled. modemBasic(1) Modem Basic mode is enabled.
Table 1394. BMC LAN IP Address Source Type Variable Name:DellBMCLANIPAddressSourceType Data Type:Integer Possible Data Values Meaning of Data Value -- unspecified(0) Source is unspecified. static(1) IP address is static. dhcp(2) Dynamic Host Configuration Protocol (DHCP) used to obtain IP address. biosOrSystemSoftware(3) BIOS or system software provided IP Address. other(4) Other protocol used to obtain IP address. Table 1395.
formFactorTypeIsDualWidth HalfHeight(2) Form Factor Type is DualWidthHalfHeight. formFactorTypeIsSingleWid thFullHeight(3) Form Factor Type is SingleWidthFullHeight. formFactorTypeIsDualWidth FullHeight(4) Form Factor Type is DualWidthFullHeight. formFactorTypeIsSingleWid thQuarterHeight(5) Form Factor Type is SingleWidthQuarterHeight. formFactorTypeIs1UHalfWid th(6) Form Factor Type is 1UHalfWidth. formFactorTypeIs1UQuarter Width(7) Form Factor Type is 1UQuarterWidth.
, fruIndex Table 1399. FRU Chassis Index Name fruChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1 Description Defines the index (one-based) of the chassis containing the FRU. Syntax DellObjectRange Access Read-only Table 1400. FRU Index Name fruIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.2 Description Defines the index (one-based) of the FRU. Syntax DellObjectRange Access Read-only Table 1401. FRU Information Status Name fruInformationStatus Object ID 1.3.6.1.4.1.
Table 1404. FRU Manufacturer Name Name fruManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.6 Description Defines the manufacturer of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1405. FRU Serial Number Name Name fruSerialNumberName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.7 Description Defines the serial number of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only Table 1406. FRU Part Number Name Name fruPartNumberName Object ID 1.3.
Description Defines the asset tag of the FRU. Syntax DisplayString (SIZE (0..64)) Access Read-only Field Replaceable Unit Group Variable Values This section includes definitions for server administrator-specific variable values. Table 1410. FRU Information State Variable Name: DellFRUInformationState Data Type: Integer Possible Data Values Meaning of Data Value ok(1) FRU information is okay. notSupported(2) FRU information is not supported. notAvailable(3) FRU information is not available.
Storage Management Group 3 The Storage Management Group is composed of the following: • Storage Management Group—information about the software product and system status. • Storage Management Information Group—properties about the Simple Network Management Protocol (SNMP) agent. • Global Data Group—system status. • Physical Devices Group—physical devices managed by the software. • Logical Devices Group—logical devices managed by the software. • Storage Management Event Group—SNMP traps.
4: Unknown Syntax Integer Access Read-only Table 1413. Software Manufacturer Name softwareManufacturer Object ID 1.3.6.1.4.1.674.10893.1.20.3 Description Identifies the manufacturer of the Storage Management software. Syntax DisplayString Access Read-only Table 1414. Software Product Name softwareProduct Object ID 1.3.6.1.4.1.674.10893.1.20.4 Description Identifies product information for the Storage Management software. Syntax DisplayString Access Read-only Table 1415.
Table 1417. Description Name description Object ID 1.3.6.1.4.1.674.10893.1.20.100.2 Description Provides a short description of this management software. Syntax DisplayString Access Read-only Table 1418. Agent Vendor Name agentVendor Object ID 1.3.6.1.4.1.674.10893.1.20.100.3 Description Identifies the name of the management software manufacturer. Syntax DisplayString Access Read-only Table 1419. Agent Version Name agentVersion Object ID 1.3.6.1.4.1.674.10893.1.20.100.
Syntax Integer Access Read-only Table 1422. Agent Time Stamp Name agentTimeStamp Object ID 1.3.6.1.4.1.674.10893.1.20.110.3 Description Identifies the last time that the agent values have been updated. Universal time in seconds since UTC 1/1/70. Syntax Integer Access Read-only Table 1423. Agent Get Timeout Name agentGetTimeout Object ID 1.3.6.1.4.1.674.10893.1.20.110.
Table 1426. Agent Hostname Name agentHostname Object ID 1.3.6.1.4.1.674.10893.1.20.110.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1427. Agent IP Address Name agentIPAddress Object ID 1.3.6.1.4.1.674.10893.1.20.110.8 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1428. Agent Software Status Name agentSoftwareStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.
Table 1431. Agent Management Software URL Name Name agentManagementSoftwareURLName Object ID 1.3.6.1.4.1.674.10893.1.20.110.12 Description Identifies the Universal Resource Locator (URL) of the systems management software. Syntax DisplayString Access Read-only Table 1432. Agent Global System Status Name agentGlobalSystemStatus Object ID 1.3.6.1.4.1.674.10893.1.20.110.13 Description Global health information for the subsystem managed by the Storage Management software.
Syntax DellStatus Access Read-only Table 1434. Agent Smart Thermal Shutdown Name agentSmartThermalShutdown Object ID 1.3.6.1.4.1.674.10893.1.20.110.15 Description Indicates the status of smart thermal shutdown for PowerVault 220S and PowerVault 221S enclosures.
• EMM Connection Table — describes the connection between each EMM on the managed system and its enclosure. Each enclosure number in the table corresponds to that enclosure instance in the Enclosure Table. • Battery Table — describes available properties for each controller battery on the managed system. • Battery Connection Table — describes the connection between each battery on the managed system and its controller.
Description Identifies the name of the controller in this subsystem as represented in Storage Management. Includes the controller type and instance. For example: PERC 3/QC 1. Syntax DisplayString Access Read-only Table 1439. Controller Vendor Name controllerVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.3 Description Identifies the controller's (re)seller's name. Syntax DisplayString Access Read-only Table 1440. Controller Type Name controllerType Object ID 1.3.6.1.4.1.674.10893.1.
Access Read-only Table 1442. Controller Severity Name controllerSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Name controllerRebuildRateInPercent Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.7 Description Identifies the percent of the compute cycles dedicated to rebuilding failed array disks.
Syntax Integer Access Read-only Table 1446. Controller Physical Device Count Name controllerPhysicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.11 Description Identifies the number of physical devices on the controller channel including both disks and the controller. Syntax Integer Access Read-only Table 1447. Controller Logical Device Count Name controllerLogicalDeviceCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Description Identifies the size of memory in megabytes on the controller. If this size is 0, it is less than a megabyte. This attribute is only supported on Adaptec controllers. Syntax Integer Access Read-only Table 1451. Controller Memory Size in Bytes Name controllerMemorySizeInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.16 Description Identifies the size of memory on the controller that is less than a megabyte.
Access Read-only Table 1455. Controller C0 Port 0 Name Name controllerC0Port0Name Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.20 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1456. Controller C0 Port 0 ID Name controllerC0Port0ID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.21 Description This entry is obsolete. Fibre channel is not supported in Storage Management.
Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1460. Controller C0 Battery State Name controllerC0BatteryState Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.25 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1461. Controller C1 Port 0 World Wide Name Name controllerC1Port0WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1464. Controller C1 Target Name controllerC1Target Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.29 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1465. Controller C1 Channel Name controllerC1Channel Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.30 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax Integer Access Read-only Table 1466.
Syntax DisplayString Access Read-only Table 1469. Controller C0 Port 1 World Wide Name Name controllerC0Port1WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.34 Description This entry is obsolete. Fibre channel is not supported in Storage Management. Syntax DisplayString Access Read-only Table 1470. Controller C1 Port 1 World Wide Name Name controllerC1Port1WWN Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.35 Description This entry is obsolete.
Syntax DellStatus Access Read-only Table 1473. Controller Component Status Name controllerComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.38 Description Indicates the status of the controller itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1474. Controller Nexus ID Name controllerNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.
Description Indicates currently installed driver version of the controller Syntax DisplayString Access Read-only Table 1477. Controller PCI Slot Name controllerPCISlot Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.42 Description Indicates the PCI slot number or embedded number for controllers on the motherboard Syntax DisplayString Access Read-only Table 1478. Controller Cluster Mode Name controllerClusterMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Access Read-only Table 1481. Controller SCSI Initiator ID Name controllerSCSIInitiatorID Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.46 Description The SCSI ID of the initiator. Syntax Integer Access Read-only Table 1482. Controller Channel Count Name controllerChannelCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.47 Description The number of channels on the controller. Syntax Integer Access Read-only Table 1483.
Access Read-only Table 1486. Controller Check Consistency Rate Name controllerCheckConsistencyRate Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.51 Description The rate for check consistency on the controller. Syntax Integer Access Read-only Table 1487. Controller Patrol Read Mode Name controllerPatrolReadMode Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.52 Description Identifies the patrol read mode.
Table 1490. Controller Storport Driver Version Name controllerStorportDriverVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.55 Description Provides current Windows OS storport driver version. Not applicable for Linux. Syntax Octet String Access Read-only Table 1491. Controller Minimum Required Storport Version Name controllerMinimumRequiredStorportVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.56 Description Provides minimum required storport driver version for Windows OS only.
Access Read-only Table 1494. Controller Spin Down Unconfigured Drives Name controllerSpinDownUnconfiguredDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.60 Description Indicates controller capability to put unconfigured drives in power save mode. Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined /Not applicable Syntax Integer Access Read-only Table 1495. Controller Spin Down Hot Spare Drives Name controllerSpinDownHotSpareDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Table 1498. Controller CacheCade Name controllerCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.64 Description Indicates if the controller is CacheCade capable or not. Value: 1 Capable, 0 - Not Capable, 99 - Undetermined Syntax Integer Access Read-only Table 1499. Controller Spin Down Configured Drives Name controllerSpinDownConfiguredDrives Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.65 Description Indicates controller capability to spin down configured physical disks.
Description Indicates configured drives spin up time interval in hours. This value is added with configured drives start time to arrive at time window in which configured drives are always spin up. Value: 1 .. 24, 9999 - Undetermined Syntax Integer Access Read-only Table 1503. Controller Preserved Cache Name controllerPreservedCache Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.69 Description Indicates if preserved cache is present on the controller.
Table 1506. Channel Entry Name channelEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1 Description Defines the channel table entry. Syntax ChannelEntry Access Not accessible Index channelNumber Table 1507. Channel Number Name channelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.1 Description Identifies the instance number of the channel entry. Syntax Integer Access Read-only Table 1508. Channel Name Name channelName Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
Table 1510. Channel Severity Name channelSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1511. Channel Termination Name channelTermination Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.5 Description Identifies the type of SCSI termination on this channel. Termination is required for proper operation of this channel.
Syntax DellStatus Access Read-only Table 1514. Channel Component Status Name channelComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8 Description The status of the channel itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1515. Channel Nexus ID Name channelNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.
3: Fibre Channel 4: Serial Storage Architecture (SSA) 6: Universal Serial Bus (USB) 7: SATA 8: SAS 9: PCIe Syntax Integer Access Read-only Enclosure Table This table describes available properties for each enclosure on the managed system. The following object sets up the Enclosure Table. Table 1518. Enclosure Table Name enclosureTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.3 Description Defines the enclosure table. Syntax SEQUENCE OF EnclosureEntry Access Not accessible Table 1519.
Description Identifies the enclosure's name as represented in Storage Management. Syntax DisplayString Access Read-only Table 1522. Enclosure Vendor Name enclosureVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.3 Description Identifies the enclosure's (re)seller's name. Syntax DisplayString Access Read-only Table 1523. Enclosure State Name enclosureState Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Syntax DisplayString Access Read-only Table 1526. Enclosure Processor Version Name enclosureProcessorVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.7 Description This entry is obsolete for Storage Management. Syntax DisplayString Access Read-only Table 1527. Enclosure Service Tag Name enclosureServiceTag Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.8 Description The enclosure identification used when consulting customer support.
Access Read-only Table 1531. Enclosure Product ID Name enclosureProductID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.12 Description Identifies the enclosure's product identification. This also corresponds to the enclosure type. Syntax DisplayString Access Read-only Table 1532. Enclosure Kernel Version Name enclosureKernelVersion Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.13 Description This entry is obsolete for Storage Management.
2: Dell PowerVault 200S (PowerVault 201S) 3: Dell PowerVault 210S (PowerVault 211S) 4: Dell PowerVault 220S (PowerVault 221S) 5: Dell PowerVault 660F 6: Dell PowerVault 224F 7: Dell PowerVault 660F/PowerVault 224F 8: Dell MD1000 9: Dell MD1120 Syntax DisplayString Access Read-only Table 1536. Enclosure Processor2 Version Name enclosureProcessor2Version Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.17 Description This entry is obsolete for Storage Management.
Table 1539. Enclosure Alarm Name enclosureAlarm Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20 Description Identifies the current status of the enclosure's alarm (PowerVault 220S and PowerVault 221S only.) Possible values: 1: Disabled 2: Enabled Syntax Integer Access Read-only Table 1540. Enclosure Backplane Part Number Name enclosureBackplanePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.21 Description Identifies the part number of the enclosure's backplane.
Access Read-only Table 1543. Enclosure Component Status Name enclosureComponentStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24 Description The status of the enclosure itself without the propagation of any contained component status. Possible values: 1: Other 2: Unknown 3: OK 4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1544. Enclosure Nexus ID Name enclosureNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.
Table 1547. Enclosure Part Number Name enclosurePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28 Description The part number of the enclosure. Syntax DisplayString Access Read-only Table 1548. Enclosure Serial Number Name enclosureSerialNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.29 Description Serial number of the enclosure. Syntax DisplayString Access Read-only Table 1549. Enclosure SAS Address Name enclosureSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.
NOTE: A value of 9999 indicates that the feature is not available. Syntax Integer Access Read-only Table 1552. Enclosure Empty Slot Count Name enclosureEmptySlotCount Object ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.33 Description Shows the number of empty physical disk slots in a storage enclosure.
Access Read-only Table 1556. Array Disk Name Name arrayDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2 Description Identifies the name of the array disk as represented in Storage Management. Syntax DisplayString Access Read-only Table 1557. Array Disk Vendor Name arrayDiskVendor Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.3 Description The array disk's manufacturer's name. Syntax DisplayString Access Read-only Table 1558. Array Disk State Name arrayDiskState Object ID 1.
34: Predictive Failure 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers. 39: Foreign 40: Clear 41: Unsupported 53: Incompatible 56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached read-only state. Syntax Integer Access Read-only Table 1559. Array Disk Severity Name arrayDiskSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5 Description This entry is obsolete for Storage Management.
Syntax DisplayString Access Read-only Table 1563. Array Disk Enclosure ID Name arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9 Description Identifies the SCSI ID of the enclosure processor to which this array disk belongs. Syntax DisplayString Access Read-only Table 1564. Array Disk Channel Name arrayDiskChannel Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.10 Description Identifies the bus to which this array disk is connected.
Description The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte. Syntax Integer Access Read-only Table 1568. Array Disk Largest Contiguous Free Space in Bytes Name arrayDiskLargestContiguousFreeSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.14 Description The size of the largest contiguous free space on this array disk in bytes that is less than a megabyte.
Table 1572. Array Disk Used Space in Bytes Name arrayDiskUsedSpaceInBytes Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.18 Description Identifies the size in bytes of the used space on the array disk that is smaller than a megabyte. This size plus the arrayDiskUsedSpaceInMB is the total amount of used space on the array disk. Syntax Integer Access Read-only Table 1573. Array Disk Free Space in Megabytes Name arrayDiskFreeSpaceInMB Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Syntax Integer Access Read-only Table 1576. Array Disk Spare State Name arrayDiskSpareState Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22 Description Identifies the status of the array disk as a spare. Possible states: 1: Disk is a member of a virtual disk 2: Disk is a member of a disk group 3: Disk is a global hot spare 4: Disk is a dedicated hot spare 5: Not a spare 99: Not applicable Syntax Integer Access Read-only Table 1577.
4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1579. Array Disk Device Name Name arrayDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.25 Description Identifies the operating system device name for this disk. Syntax DisplayString Access Read-only Table 1580. Array Disk Nexus ID Name arrayDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.26 Description Indicates the durable unique ID for this array disk.
Description Indicates the speed at which the drive is actually running in MPS (megabytes per second). Syntax Integer Access Read-only Table 1584. Array Disk Capable Speed Name arrayDiskCapableSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.30 Description Indicates the maximum speed at which the drive is capable of negotiating in MPS (megabytes per second). Syntax Integer Access Read-only Table 1585. Array Disk Smart Alert Indication Name arrayDiskSmartAlertIndication Object ID 1.3.6.
Table 1588. Array Disk Manufacture Year Name arrayDiskManufactureYear Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34 Description Indicates the four digit year in which this disk was manufactured. Syntax DisplayString Access Read-only Table 1589. Array Disk Media Type Name arrayDiskMediaType Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.35 Description The Media type of the array disk. Possible Values: 1:unknown 2:hdd 3:ssd Syntax INTEGER Access Read-only Table 1590.
Syntax Octet String Access Read-only Table 1593. Array Disk Alta Revision Id Name arrayDiskAltaRevisionId Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.39 Description Provides revision ID for Alta interposer. Syntax Octet String Access Read-only Table 1594. Array Disk Encryption Capable Name arrayDiskEncryptionCapable Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.40 Description Indicates if physical disk is encryption capable.
Description Indicates drive write cache capability for PCIe SSD devices. Value: 1 Enabled, 0 - Disabled, 99 - Undetermined/NotApplicable Syntax Integer Access Read-only Table 1598. Array Disk Model Number Name arrayDiskModelNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.44 Description Provides PCIe SSD device model number. Syntax DisplayString Access Read-only Table 1599. Array Disk Life Remaining Name arrayDiskLifeRemaining Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Syntax INTEGER Access Read-only Table 1602. Array Disk Read Only Name arrayDiskReadOnly Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.48 Description Provides the read only attribute for PCIe SSD. Possible Values: Yes, No, Not Applicable Syntax DisplayString Access Read-only Table 1603. Array Disk Remaining Rated Write Endurance Name arrayDiskRemainingRatedWriteEndurance Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Access Read-only Table 1606. Array Disk Max Link Width Name arrayDiskMaxLinkWidth Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.52 Description Provides the information regarding Max Link Width of array disk. Possible Values: 0–8 Syntax INTEGER Access Read-only Table 1607. Array Disk Negotiated Link Width Name arrayDiskNegotiatedLinkWidth Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.53 Description Provides the information regarding Negotiated Link Width of array disk.
Description Defines the array disk enclosure connection table entry. Syntax Syntax ArrayDiskEnclosureConnectionEntry Access Not accessible Index Index arrayDiskEnclosureConnectionNumber Table 1610. Array Disk Enclosure Connection Number Name arrayDiskEnclosureConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.1 Description Identifies the instance number of the array disk enclosure connection entry. Syntax Integer Access Read-only Table 1611.
Table 1614. Array Disk Enclosure Connection Enclosure Number Name arrayDiskEnclosureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.5 Description Identifies the instance number in the enclosureTable of the enclosure to which this array disk belongs. Syntax Integer Access Read-only Table 1615. Array Disk Enclosure Connection Controller Name Name arrayDiskEnclosureConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.
NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management. The following object sets up the Array Disk Channel Connection Table. Table 1617. Array Disk Channel Connection Table Name arrayDiskChannelConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.6 Description Defines the array disk channel connection table. Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry Access Not accessible Table 1618.
Fan Table This table describes available properties for each fan on the managed system. The following object sets up the Fan Table. Table 1626. Fan Table Name fanTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.7 Description Defines the fan table. Syntax SEQUENCE OF FanEntry Access Not accessible Table 1627. Fan Entry Name fanEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1 Description Defines the fan table entry. Syntax FanEntry Access Not accessible Index fanNumber Table 1628.
Description Identifies the fan's (re)seller's name. Syntax DisplayString Access Read-only Table 1631. Fan State Name fanState Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.4 Description Identifies the current state of the fan. Possible states: 0: Unknown 1: Ready 2: Failed 3: Online 4: Offline 6: Degraded 21: Missing Syntax Integer Access Read-only Table 1632. Fan Severity Name fanSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.
Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1635. Fan Probe Minimum Critical Name fanProbeMinimumCritical Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.8 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1636. Fan Probe Maximum Warning Name fanProbeMaximumWarning Object ID 1.3.6.1.
Table 1639. Fan1 Part Number Name fan1PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12 Description Identifies the part number of the fan in the enclosure. Syntax DisplayString Access Read-only Table 1640. Fan 2 Part Number Name fan2PartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.13 Description This entry is obsolete. This setting is not supported by fans managed under Storage Management. Syntax DisplayString Access Read-only Table 1641.
4: Non-critical 5: Critical 6: Non-recoverable Syntax DellStatus Access Read-only Table 1643. Fan Nexus ID Name fanNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.16 Description Durable unique ID for this fan. Syntax DisplayString Access Read-only Table 1644. Fan Revision Name fanRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.17 Description Indicates the revision number of the fan in the enclosure.
Access Not accessible Index fanConnectionNumber Table 1647. Fan Connection Number Name fanConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1 Description Identifies the instance number of the fan connection entry. Syntax Integer Access Read-only Table 1648. Fan Connection Fan Name Name fanConnectionFanName Object ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.2 Description Identifies the name of the fan in this connection as represented in Storage Management.
Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs. Syntax Integer Access Read-only Power Supply Table Table 1652. Power Supply Table Name powerSupplyTable Object ID 1.3.6.1.4.1.674.10892.1.600.12 Description Defines the Power Supply Table. Syntax PowerSupplyTableEntry Access Not accessible Table 1653. Power Supply Table Entry Name powerSupplyTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.12.
Description Defines the capabilities of the power supply. Syntax DellPowerSupplyStateCapabilitiesUnique (Power Supply State Capabilities Unique) Access Read-only Table 1657. Power Supply State Settings Unique Name powerSupplyStateSettingsUnique Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.4 Description Defines the state and settings of the power supply. Syntax DellPowerSupplyStateSettingsUnique (Power Supply State Settings Unique) Access Read-only Table 1658.
Syntax DellString Access Read-only Table 1662. Power Supply Input Voltage Name powerSupplyInputVoltage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.9 Description Defines the input voltage to the power supply in volts. Syntax DellSigned32BitRange Access Read-only Table 1663. Power Supply Power Unit Index Reference Name powerSupplypowerUnitIndexReference Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.10 Description Defines the index to the associated system power unit in this chassis.
Access Read-only Table 1667. Power Supply Rated Input Wattage Name powerSupplyRatedInputWattage Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14 Description Defines the rated input wattage of the power supply (in tenths of Watts.) Syntax DellSigned32BitRange Access Read-only Power Supply Connection Table This table describes the connection between each power supply on the managed system and its enclosure.
Table 1671. Power Supply Connection Power Supply Name Name powerSupplyConnectionPowerSupplyName Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.2 Description Identifies the name of the power supply in this connection as represented in Storage Management. Syntax DisplayString Access Read-only Table 1672. Power Supply Connection Power Supply Number Name powerSupplyConnectionPowerSupplyNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.
NOTE: Available above 1.04 firmware version. Syntax DisplayString Access Read-only Temperature Probe Table Table 1676. Temperature Probe Table Name temperatureProbeTable Object ID 1.3.6.1.4.1.674.10892.1.700.20 Description Defines the Temperature Probe Table. Syntax TemperatureProbeTableEntry Access Not accessible Table 1677. Temperature Probe Table Entry Name temperatureProbeTableEntry Object ID 1.3.6.1.4.1.674.10892.1.700.20.1 Description Defines the Temperature Probe Table entry.
Table 1680. Temperature Probe State Capabilities Name temperatureProbeStateCapabilities Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.3 Description Defines the capabilities of the temperature probe. Syntax DellStateCapabilities Access Read-only Table 1681. Temperature Probe State Settings Name temperatureProbeStateSettings Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.4 Description Defines the state and settings of the temperature probe. Syntax DellStateSettings Access Read-only Table 1682.
Access Read-only Table 1685. Temperature Probe Location Name Name temperatureProbeLocationName Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.8 Description Defines the location of the temperature probe in this chassis. Syntax DellString Access Read-only Table 1686. Temperature Probe Upper Nonrecoverable Threshold Name temperatureProbeUpperNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Table 1690. Temperature Probe Lower Critical Threshold Name temperatureProbeLowerCriticalThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.13 Description Defines the value of the temperature probe’s lower critical threshold. Syntax DellSigned32BitRange Access Read-only Table 1691. Temperature Probe Lower Nonrecoverable Threshold Name temperatureProbeLowerNonRecoverableThreshold Object ID 1.3.6.1.4.1.674.10892.1.700.20.1.
Table 1694. Temperature Probe Connection Table Name temperatureConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.12 Description Defines the temperature probe connection table. Syntax SEQUENCE OF TemperatureConnectionEntry Access Not accessible Table 1695. Temperature Probe Connection Entry Name temperatureConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1 Description Defines the temperature probe connection table entry.
Syntax Integer Access Read-only Table 1699. Temperature Probe Connection Enclosure Name Name temperatureConnectionEnclosureName Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.4 Description Identifies the name of the enclosure as represented in Storage Management to which this temperature probe belongs. Syntax DisplayString Access Read-only Table 1700. Temperature Probe Connection Enclosure Number Name temperatureConnectionEnclosureNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.12.1.
Index enclosureManagementModuleNumber Table 1703. Enclosure Management Module Number Name enclosureManagementModuleNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.1 Description Identifies the instance number of the enclosure management module entry. Syntax Integer Access Read-only Table 1704. Enclosure Management Module Name Name enclosureManagementModuleName Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
Access Read-only Table 1707. Enclosure Management Module Severity Name enclosureManagementModuleSeverity Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.5 Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and ComponentStatus for each device. Syntax Integer Access Read-only Table 1708. Enclosure Management Module Part Number Name enclosureManagementModulePartNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
Table 1711. Enclosure Management Module Maximum Speed Name enclosureManagementModuleMaxSpeed Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.9 Description Identifies the maximum bus speed of the enclosure management module. Syntax DisplayString Access Read-only Table 1712. Enclosure Management Module Roll-Up Status Name enclosureManagementModuleRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.10 Description Severity of the enclosure management module state.
Table 1714. Enclosure Management Module Nexus ID Name enclosureManagementModuleNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.12 Description Durable unique ID for this EMM. Syntax DisplayString Access Read-only Table 1715. Enclosure Management Module Revision Name enclosureManagementModuleRevision Object ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.13 Description Identifies the revision number of the enclosure management module.
Table 1718. Enclosure Management Module Connection Number Name enclosureManagementModuleConnectionNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.1 Description Identifies the instance number of the enclosure memory module connection entry. Syntax Integer Access Read-only Table 1719. Enclosure Management Module Connection EMM Name Name enclosureManagementModuleConnectionEMMName Object ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.
Description Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs. Syntax Integer Access Read-only Battery Table Table 1723. Battery Table Name batteryTable Object ID 1.3.6.1.4.1.674.10892.1.600.50 Description Defines the Battery Table. Syntax SEQUENCE OF BatteryTableEntry Access Not accessible Table 1724. Battery Table Entry Name batteryTableEntry Object ID 1.3.6.1.4.1.674.10892.1.600.50.
Description Defines the state capabilities of the battery. Syntax DellStateCapabilities Access Read-only Table 1728. Battery State Settings Name batteryStateSettings Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.4 Description Defines the state settings of the battery. Syntax DellStateSettings Access Read-only Table 1729. Battery Status Name batteryStatus Object ID 1.3.6.1.4.1.674.10892.1.600.50.1.5 Description Defines the status of the battery.
Table 1732. Battery Connection Table Name batteryConnectionTable Object ID 1.3.6.1.4.1.674.10893.1.20.130.16 Description Defines the battery connection table. Syntax SEQUENCE OF BatteryConnectionEntry Access Not accessible Table 1733. Battery Connection Entry Name batteryConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1 Description Defines the battery connection table entry.
Access Read-only Table 1737. Battery Connection Controller Name Name batteryConnectionControllerName Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.4 Description Identifies the name of the controller as represented in Storage Management to which this battery belongs. Syntax DisplayString Access Read-only Table 1738. Battery Connection Controller Number Name batteryConnectionControllerNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.
Access Not accessible Table 1741. Tape Drive Number Name tapeDriveNumber Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.1 Description Instance number of this tape drive entry. Syntax INTEGER Access Read-only Table 1742. Tape Drive Name Name tapeDriveName Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.2 Description The name of the tape drive as represented in Storage Management. Syntax DisplayString Access Read-only Table 1743. Tape Drive Vendor Name tapeDriveVendor Object ID 1.3.6.
Access Read-only Table 1746. Tape Drive Bus Type Name tapeDriveBusType Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.6 Description The bus type of the tape drive. Possible values: 8. SAS Syntax INTEGER Access Read-only Table 1747. Tape Drive SAS Address Name tapeDriveSASAddress Object ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.7 Description The specified SAS address if this is a SAS tape drive. Syntax DisplayString Access Read-only Table 1748.
Virtual Disk Table This table describes available properties for each virtual disk on the managed system. The following object sets up the Virtual Disk Table. Table 1749. Virtual Disk Table Name virtualDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.1 Description Defines the virtual disk table. Syntax SEQUENCE OF VirtualDiskEntry Access Not accessible Table 1750. Virtual Disk Entry Name virtualDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.
Table 1753. Virtual Device Disk Name Name virtualDiskDeviceName Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.3 Description Identifies the device name used by this virtual disk's member disks. Syntax DisplayString Access Read-only Table 1754. Virtual Disk State Name virtualDiskState Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.4 Description Identifies the current state of this virtual disk. Possible states: 0: Unknown 1: Ready - The disk is accessible and has no known problems.
Access Read-only Table 1756. Virtual Disk Length in Megabytes Name virtualDiskLengthInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.6 Description Identifies the size of this virtual disk in megabytes. If this size is 0, it is smaller than a megabyte. Syntax INTEGER Access Read-only Table 1757. Virtual Disk Length in Bytes Name virtualDiskLengthBytes Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Description Indicates whether the controller's write cache are used when writing to a virtual disk. Possible values: 1: Enabled - Adaptec Write Cache Enabled Protected 2: Disabled - Adaptec Write Cache Disabled 3: LSI Write Back 4: LSI Write Through 5: Enabled Always (Adaptec only) 6: Enabled Always (SAS only) 9: Not Applicable Syntax INTEGER Access Read-only Table 1761. Virtual Disk Read Policy Name virtualDiskReadPolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.
Description Indicates the virtual disk's RAID type. Possible values: 1: Concatenated 2: RAID-0 3: RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAID-50 19: Concatenated RAID 1 24: RAID-60 25: CacheCade Syntax INTEGER Access Read-only Table 1764. Virtual Disk Current Stripe Size in Megabytes Name virtualDiskCurStripeSizeInMB Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.14 Description Identifies the stripe size of this virtual disk in megabytes. If this size is 0, it is smaller than a megabyte.
Table 1768. Virtual Disk LUN ID Name virtualDiskLunID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.18 Description This entry is obsolete. This property is not supported by virtual disks managed under Storage Management. Syntax INTEGER Access Read-only Table 1769. Virtual Disk Roll-Up Status Name virtualDiskRollUpStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.19 Description Severity of the virtual disk state. This is the combined status of the virtual disk and its components.
Table 1771. Virtual Disk Nexus ID Name virtualDiskNexusID Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21 Description Durable unique ID for this virtual disk. Syntax DisplayString Access Read-only Table 1772. Virtual Disk Array Disk Type Name virtualDiskArrayDiskType Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.22 Description Identifies the type of array (physical) disks used to create the virtual disk.
Table 1775. Virtual Disk is CacheCade Name virtualDiskIsCacheCade Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.25 Description Indicates if this virtual disk is configured as CacheCade. Value: 1 - Yes, 0 - No, 99 - Undetermined Syntax INTEGER Access Read-only Table 1776. Virtual Disk Disk Cache Policy Name virtualDiskDiskCachePolicy Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.26 Description Indicates disk cache policy of the logical device.
Description A table of managed virtual disk partitions. The number of entries is related to number of partitions discovered in the system. The maximum number of entries is implementation dependent. NOTE: The properties in this table may not be applicable to all entries. Syntax SEQUENCE OF VirtualDiskPartitionEntry Access Not-Accessible Table 1780. Virtual Disk Partition Entry Name virtualDiskPartitionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.
Access Read-only Table 1784. Virtual Disk Partition Size Name virtualDiskPartitionSize Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.4 Description Size of the partition in GB. Syntax INTEGER Access Read-only Table 1785. Virtual Disk Partition Fluid Cache Status Name virtualDiskPartitionFluidCacheStatus Object ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.5 Description Indicates if the partition has associated fluid cache. Syntax OCTET STRING Access Read-only Table 1786.
Description An entry in the Fluid Cache table. A row in this table cannot be created or deleted by SNMP operations on columns of the table. Syntax FluidCacheEntry Access Not-Accessible Table 1789. Fluid Cache Number Name fluidCacheNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.1 Description Instance number of this fluid cache entry. Syntax INTEGER Access Read-only Table 1790. Fluid Cache Name Name fluidCacheName Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.
Description Indicates the Entitlement Identifier for the license of the fluid cache subsystem. Syntax OCTET STRING Access Read-only Table 1794. Fluid Cache License Duration Name fluidCacheLicenseDuration Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.6 Description Indicates the duration of the license validity. Syntax OCTET STRING Access Read-Only Table 1795. Fluid Cache License Capacity Name fluidCacheLicenseCapacity Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.
Access Read-only Table 1799. Fluid Cache License Product ID Name fluidCacheLicenseProductId Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.11 Description Indicates the product ID of the license of the fluid cache susbsytem. Syntax OCTET STRING Access Read-only Table 1800. Fluid Cache License Date Sold Name fluidCacheLicenseDateSold Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.12 Description Indicates the date on which the license for the fluid cache subsystem is sold.
Table 1804. Fluid Cache Nexus Name fluidCacheNexus Object ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.16 Description Indicates the unique ID of the fluid cache component. Syntax OCTET STRING Access Read-only Fluid Cache Disk Table 1805. Fluid Cache Disk Table Name fluidCacheDiskTable Object ID 1.3.6.1.4.1.674.10893.1.20.140.5 Syntax SEQUENCE OF FluidCacheDiskEntry Access Not-Accessible Table 1806. Fluid Cache Disk Entry Name fluidCacheDiskEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.
Valid values are 2 - Active, otherwise Inactive Syntax INTEGER Access Read-only Table 1810. Fluid Cache Disk Backend Device Type Name fluidCacheDiskBackendDeviceType Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.4 Description This displays the type of the backend device beneath the fluid cache disk. Values are as below 773 denotes VirtualDisk 791 denotes Partition Syntax INTEGER Access Read-only Table 1811.
Table 1814. Fluid Cache Disk Configured Mode Name fluidCacheDiskConfiguredMode Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.8 Description Configured Mode of the FluidCache. The values are : • • • 0 - Writeback mode 1 - Writethrough mode 2 - PassThrough mode Syntax INTEGER Access Read-Only Table 1815. Fluid Cache Disk Nexus Name fluidCacheDiskNexus Object ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.9 Description Durable Unique ID of the fluidcache disk.
Table 1818. Fluid Cache Pool Entry Name fluidCachePoolEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1 Syntax FluidCachePoolEntry Access Not-Accessible Table 1819. Fluid Cache Pool Number Name fluidCacheDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.1 Description Instance number of the fluid cache pool entry. Syntax INTEGER Access Read-only Table 1820. Fluid Cache Pool Store Count Name fluidCachePoolStoreCount Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.
Syntax INTEGER Access Read-only Table 1824. Fluid Cache Pool High Availability State Name fluidCachePoolHighAvailabilityState Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.6 Description Indicates if the fluid cache pool is operating in high availability mode. Syntax OCTET STRING Access Read-Only Table 1825. Fluid Cache Pool Nexus Name fluidCachePoolNexus Object ID 1.3.6.1.4.1.674.10893.1.20.140.6.1.7 Description Durable unique ID of the fluid cache pool entry.
Description Defines the array disk logical connection table. Syntax SEQUENCE OF arrayDiskLogicalConnectionEntry Access Not accessible Table 1828. Array Disk Logical Connection Entry Name arrayDiskLogicalConnectionEntry Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1 Description Defines the array disk logical connection table entry. Syntax ArrayDiskLogicalConnectionEntry Access Not accessible Index arrayDiskLogicalConnectionNumber Table 1829.
Table 1832. Array Disk Logical Connection Virtual Disk Name Name arrayDiskLogicalConnectionVirtualDiskName Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.4 Description Identifies the name of the virtual disk to which this array disk belongs. Syntax DisplayString Access Read-only Table 1833. Array Disk Logical Connection Virtual Disk Number Name arrayDiskLogicalConnectionVirtualDiskNumber Object ID 1.3.6.1.4.1.674.10893.1.20.140.3.1.
Description Storage Management event message number. Syntax Integer Access Read-only Table 1837. Description Event Name descriptionEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.2 Description Storage Management event message text describing the alert. Syntax DisplayString Access Read-only Table 1838. Location Event Name locationEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.3 Description Additional information identifying the location of the object causing the alert.
Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Table 1842. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.7 Description Current status of object causing the alert, if applicable. Syntax DellStatus Access Read-only Table 1843. Previous Status Event Name previousStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.8 Description Previous status of object causing the alert if applicable.
Change Management Group 4 The Change Management Group lets you monitor information about the Dell devices and software that are present on a particular managed computer chassis. This information is collected during an inventory scan. NOTE: On systems running Linux, the optional srvadmin-cm RPM package must be installed for Dell OpenManage Server Administrator to respond to SNMP queries in this group. See the Server Administrator Installation Guide for more information.
Device Group Table The following object sets up the Device Group Table. Table 1847. Device Table Name deviceTable Object ID 1.3.6.1.4.1.674.10899.1.5 Description Defines the Device Table. Syntax SEQUENCE OF DeviceEntry Access Not accessible Table 1848. Device Entry Name deviceEntry Object ID 1.3.6.1.4.1.674.10899.1.5.1 Description Defines a device entry. Syntax DeviceEntry Access Not accessible Table 1849. Device Index Name deviceIndex Object ID 1.3.6.1.4.1.674.10899.1.5.1.
Table 1852. Device Vendor ID Name deviceVendorID Object ID 1.3.6.1.4.1.674.10899.1.5.1.4 Description Defines the ID for the vendor supplying the device. Syntax Octet String Access Read-only Table 1853. Device ID Name deviceDeviceID Object ID 1.3.6.1.4.1.674.10899.1.5.1.5 Description Defines the ID for the device. Syntax Octet String Access Read-only Table 1854. Device Sub ID Name deviceSubID Object ID 1.3.6.1.4.1.674.10899.1.5.1.
Table 1856. Application Table Name applicationTable Object ID 1.3.6.1.4.1.674.10899.1.6 Description Defines a table of application information for the system. Syntax Defines a table of application information for the system. Access Not accessible Table 1857. Application Entry Name applicationEntry Object ID 1.3.6.1.4.1.674.10899.1.6.1 Description Defines an application entry. Syntax ApplicationEntry Access Read-only Table 1858. Application Index Name aplicationIndex Object ID 1.3.
Description Identifies the version of the application. Syntax DisplayString Access Read-only Table 1862. Application Display String Name aplicationDisplayString Object ID 1.3.6.1.4.1.674.10899.1.6.1.5 Description A user visible display string that describes the application. Syntax DisplayString Access Read-only Table 1863. Application Sub-Component ID Name applicationSubComponentID Object ID 1.3.6.1.4.1.674.10899.1.6.1.6 Description The sub-component ID for the application.
Chassis Management Controller Group 5 Dell Remote Access Controller Out-of-Band Group The Dell Remote Access Controller Out-of-Band MIB contains information for both Chassis Management Controller (CMC) and RAC Legacy Alerting. This MIB consists of information for the following groups: Product Information The following MIB attributes provide product information for the chassis management controller: Table 1864. DRsProductName Name drsProductName Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Access Read-only Table 1868. DRsProductVersion Name drsProductVersion Object ID 1.3.6.1.4.1.674.10892.2.1.1.5 Description Defines the product version of a chassis management controller. Syntax DellString Access Read-only Table 1869. DRsChassisServiceTag Name drsChassisServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.6 Description Defines the Service Tag of the chassis. Syntax DellString Access Read-only Table 1870. DRsProductURL Name drsProductURL Object ID 1.3.6.1.4.1.674.10892.
Table 1873. DRsProductChassisName Name drsProductChassisName Object ID 1.3.6.1.4.1.674.10892.2.1.1.10 Description Defines the name of the chassis. Syntax DellString Access Read-only Table 1874. DRsSystemServiceTag Name drsSystemServiceTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.11 Description Defines the service tag of a system. Syntax DellString Access Read-only Table 1875. DRsProductSystemAssetTag Name drsProductSystemAssetTag Object ID 1.3.6.1.4.1.674.10892.2.1.1.
Description Defines the data center locator of the chassis. Syntax DellString Access Read-only Table 1879. DRsProductChassisAisle Name drsProductChassisAisle Object ID 1.3.6.1.4.1.674.10892.2.1.1.16 Description Defines the aisle locator of the chassis. Syntax DellString Access Read-only Table 1880. DRsProductChassisRack Name drsProductChassisRack Object ID 1.3.6.1.4.1.674.10892.2.1.1.17 Description Defines the rack locator of the chassis.
Table 1884. DRsProductChassisSystemID Name drsProductChassisSystemID Object ID 1.3.6.1.4.1.674.10892.2.1.1.21 Description Defines the system ID of the chassis. Syntax INTEGER Access Read-only Table 1885. DRsFirmwareVersion Name drsFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.2.1.2.1 Description Defines the firmware version of a chassis management controller 1. Syntax DellString Access Read-only Table 1886. DRsiKVMFirmwareVersion Name drsiKVMFirmwareVersion Object ID 1.3.6.1.4.1.
Table 1889. DRsGlobalCurrStatus Name drsGlobalCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.1 Description Defines the overall chassis status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1890. DRsIOMCurrStatus Name drsIOMCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.2 Description Defines the IOM subsystem status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1891.
Table 1894. DRsFanCurrStatus Name drsFanCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.6 Description Defines the fan subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1895. DRsBladeCurrStatus Name drsBladeCurrStatus Object ID 1.3.6.1.4.1.674.10892.2.3.1.7 Description Defines the blade subsystem health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1896.
Table 1899. DRsCMAmbientTemperature Name drsCMCAmbientTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.11 Description Defines the ambient temperature reading (in degrees Celsius) for the chassis management card. Syntax DellTemperatureReading Access Read-only Table 1900. DRsCMProcessorTemperature Name drsCMCProcessorTemperature Object ID 1.3.6.1.4.1.674.10892.2.3.1.12 Description Defines the temperature reading (in degrees Celsius) for the chassis management card processor.
Table 1904. DRsRedPrevStatus Name drsRedPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.4 Description Defines the previous redundancy status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 1905. DRsPowerPrevStatus Name drsPowerPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.5 Description Defines the previous power subsystem health status recorded by the chassis management card. Syntax DellStatus Access Read-only Table 1906.
Table 1909. DRsCMCPrevStatus Name drsCMCPrevStatus Object ID 1.3.6.1.4.1.674.10892.2.3.2.9 Description Defines the CMC health status being monitored by the chassis management card. Syntax DellStatus Access Read-only Table 1910. DRsGlobalChangeTime Name drsGlobalChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.1 Description Defines the timestamp of the most recent global status change. Syntax TimeTicks Access Read-only Table 1911. DRsIOMChangeTime Name drsIOMChangeTime Object ID 1.
Description Defines the timestamp of the most recent power health status change. Syntax TimeTicks Access Read-only Table 1915. DRsFanChangeTime Name drsFanChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.6 Description Defines the timestamp of the most recent fan health status change. Syntax TimeTicks Access Read-only Table 1916. DRsBladeChangeTime Name drsBladeChangeTime Object ID 1.3.6.1.4.1.674.10892.2.3.3.
Description Defines the CMC power table. Syntax SEQUENCE OF DrsCMCPowerTableEntry Access Not-accessible Table 1920. DRsCMC Power Table Entry Name drsCMCPowerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.4.1.1 Description Defines the CMC power table entry. Syntax DrsCMCPowerTableEntry Access Not-accessible Table 1921. DRsCMC PSUTable Name drsCMCPSUTable Object ID 1.3.6.1.4.1.674.10892.2.4.2 Description Defines the CMC PSU table.
Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently turned on. Syntax DellPowerReading Access Read-only Table 1925. DRsIdlePower Name drsIdlePower Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.3 Description Defines the power (in watts) required by the chassis infrastructure, along with the minimum power requirements for all systems currently turned on.
Description Defines the timestamp of the most recent chassis power accumulator reset. Syntax DellTimestamp Access Read-only Table 1930. DRsWattsPeakUsage Name drsWattsPeakUsage Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.8 Description Defines the chassis peak power usage (in watts) since last reset. Syntax DellPowerReading Access Read-only Table 1931. DRsWattsPeakTime Name drsWattsPeakTime Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.
Syntax DellTimestamp Access Read-only Table 1935. DRsWattsReading Name drsWattsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.13 Description Defines the instantaneous chassis power usage (in watts). Syntax DellPowerReading Access Read-only Table 1936. DRsAmpsReading Name drsAmpsReading Object ID 1.3.6.1.4.1.674.10892.2.4.1.1.14 Description Defines the instantaneous chassis current usage (in watts).
Access Read-only Table 1940. DRsPSUMonitoringCapable Name drsPSUMonitoringCapable Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.4 Description Defines the monitoring capabilities or the absence of a PSU in this location. Syntax DellCMCPSUCapable Access Read-only Table 1941. DRsPSUVoltsReading Name drsPSUVoltsReading Object ID 1.3.6.1.4.1.674.10892.2.4.2.1.5 Description Defines the instantaneous PSU voltage reading. Syntax DellPowerReading Access Read-only Table 1942.
Syntax SEQUENCE OF DrsCMCServerTableEntry Access Not-Accessible Table 1945. DRsCMCServerTableEntry Name drsCMCServerTableEntry Object ID 1.3.6.1.4.1.674.10892.2.5.1.1 Description Defines the CMC server table entry. Syntax DrsCMCServerTableEntry Access Not-Accessible CMC Server Information The following MIB tables provide CMC server information being monitored by the chassis management controller. Table 1946. DRsServerIndex Name drsServerIndex Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.
Table 1949. DRsServerSlotName Name drsServerSlotName Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.4 Description Defines the slot name of the CMC server. Syntax DellString Access Read-only Table 1950. DRsServerSlotNumber Name drsServerSlotNumber Object ID 1.3.6.1.4.1.674.10892.2.5.1.1.5 Description Defines the chassis slot number of the CMC server. Syntax DellString Access Read-only Chassis Alert The following MIB tables provide information on the chassis management controller alerts.
Table 1954. DrsCASSChangeTime Name drsCASSChangeTime Object ID 1.3.6.1.4.1.674.10892.2.20.10.4 Description Defines the time stamp of the most recent change of the alerting subsystem. Syntax TimeTicks Access Read-only Table 1955. DrsCAMessage Name drsCAMessage Object ID 1.3.6.1.4.1.674.10892.2.20.10.5 Description Defines the CSSD message of the CMC alert. Syntax DellString Access Read-only Chassis Alert 2 Table 1956. DRsCA2MessageID Name drsCA2MessageID Object ID 1.3.6.1.4.1.674.
Syntax DellString Access Read-only Table 1959. DrsCA2AlertStatus Name drsCA2AlertStatus Object ID 1.3.6.1.4.1.674.10892.2.21.10.4 Description Defines the status of the alert. Syntax DellStatus Access Read-only Table 1960. DrsCA2FQDD Name drsCA2FQDD Object ID 1.3.6.1.4.1.674.10892.2.21.10.5 Description Defines the fully qualified device descriptor of device causing the alert.
Syntax Octet String Access Read-only Table 1964. DRsAlertCurrentStatus Name drsAlertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.4 Description Current status of object causing the alert. Syntax DellStatus Access Read-only Table 1965. DRsAlertPreviousStatus Name drsAlertPreviousStatus Object ID 1.3.6.1.4.1.674.10892.2.5000.10.5 Description Previous status of object causing the alert. Syntax DellStatus Access Read-only Table 1966.
6 SNMP Traps SNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the Get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion.
Syntax DisplayString Table 1968. Table Index OID Variable Name alertTableIndexOID Object ID 1.3.6.1.4.1.674.10892.1.5000.10.2 Description Specifies the object identifier for the index attribute in the table that contains the object causing the alert. Uniquely identifies the object causing the alert and can be used to correlate different alerts caused by the same object. Syntax OBJECT IDENTIFIER Table 1969. Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.1.5000.10.
Table 1973. Message ID Variable Name alertMsgID Object ID 1.3.6.1.4.1.674.10892.4.5000.10.7 Description Specifies the enhanced message ID for the object generating the alert. Syntax DisplayString Table 1974. System FQDN Variable Name alertSystemFQDN Object ID 1.3.6.1.4.1.674.10892.4.5000.10.8 Description Specifies fully qualified domain name of the system generating the alert. Syntax DisplayString Table 1975. Service Tag Variable Name alertServiceTag Object ID 1.3.6.1.4.1.674.10892.4.
Description Line Item Explanation Memory device: DIMM_1A Serial number: 11111111 Memory device: DIMM_1B Serial number: 22222222 Specifies any additional power supply information pertaining to the event, for example: Power supply input AC is off, Power supply POK (power OK) signal is not normal, Power supply is turned off Battery sensor status: Specifies the status reported by the battery sensor, for example: Battery sensor status: Predictive failure
Description Line Item Explanation Memory device bank location: Specifies the name of the memory bank in the system that generated the message, for example: Memory device bank location: Bank_1 Memory device location: Specifies the location of the memory module in the chassis, for example: Memory device location: DIMM_A Number of devices required for full redundancy: Specifies the number of power supply or cooling devices required to achieve full
Understanding Trap Severity Traps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical components for values such as amperage, voltage, and temperature.
TrapID Name Description Severity Category Cause Support ed by RAC Platfor m exceeded a threshold 1015 alertDrscSE L Warning The RAC has detected a new event in the System Event Log with Severity: Warning Major Error RAC detected a new All system event log with warning severity (detailed log info is in drsAlert Message varbind).
drsCASSPrevStatus, drsCASSChangeTime and drsCAMessage. The trap variables are defined in the Dell Remote Access Controller Out-of-Band Group section. Table 1979. PowerEdge M1000e CMC traps TrapID Name Description Severity Category 2000 alertCMCTestTrap CMC has generated a test trap. Informational Error Events 2002 alertCMCNormalTrap CMC reported a returnto-normal or informational event. Normal Error Events 2003 alertCMCWarningTra CMC reported a warning Warning p event.
Table 1981. Battery Traps TrapID Description Category SubCategory Severity Battery state has returned to Status Events normal; or battery presence had been detected. Battery Information al Battery is low. Status Events Battery Minor Battery has failed or battery is absent. Error Events Battery Critical Description Category SubCategory Severity Cable failure. Error Events Cable Critical Description Category SubCategory Severity Chassis Management Controller detected a warning.
Table 1985. Hardware Configuration Traps TrapID Description Category SubCategory Severity Status Events Hardware Configuration Information al Status Events Hardware Configuration Minor Error Events Hardware Configuration Critical Category SubCategory Severity Status Events IO Virtualization Minor Error Events IO Virtualization Critical Category SubCategory Severity Link status information. Status Events Link Status Information al Link status failure or critical event.
TrapID Description Category SubCategory Severity Power Supply Critical alert2PowerSupplyFailure 2185 Power supply has detected a Error Events failure. Table 1989. Power Supply Absent Trap TrapID Description Category SubCategory Severity Power supply is absent. Error Events Power Supply Critical Category SubCategory Severity Status Events Redundancy Information al Redundancy is degraded. Status Events Redundancy Minor Redundancy is lost.
TrapID Description Category SubCategory Severity 2377 System Event Log failure or critical event.
Table 1996.
TrapID Description Category Subcategory Severity Storage fan failure. Error Events Fan Critical alert2StorageFanFailure 4201 Table 2000. Storage Physical Disk Traps TrapID Description Category Subcategory Severity Error Events Physical Disk Information al Error Events Physical Disk Minor Storage physical disk failure.
TrapID Description Category Subcategory Severity Storage Management Critical Category Subcategory Severity Error Events Temperature Probe Information al Error Events Temperature Probe Minor Error Events Temperature Probe Critical Category Subcategory Severity Error Events Virtual Disk Information al Error Events Virtual Disk Minor Error Events Virtual Disk Critical status change associated with this trap.
Table 2005. Audit CMC Traps TrapID Description Category SubCategory Severity Chassis Management Status Events Controller audit information. CMC Information al Chassis Management Controller audit warning. Status Events CMC Minor Chassis Management Controller audit failure or critical event. Error Events CMC Critical Description Category SubCategory Severity License information. Status Events License Information al License warning. Status Events License Minor License failure.
Table 2008. Configuration IO Virtualization Traps TrapID Description Category SubCategory Severity Status Events IO Virtualization Information al Description Category SubCategory Severity Test trap generated by CMC in response to a user request. Status Events Test Information al alert2IOVConfigurationInformation 10747 IO virtualization configuration information. Table 2009.
TrapID Description Severity 65801 Over-Temperature Problem (Upper Critical - going high) Critical 65929 Over-Temperature Problem Cleared Information 131328 Under-Voltage Warning (Lower Non Critical - going low) Warning 131456 Under-Voltage Warning Cleared Information 131330 Under-Voltage Problem (Lower Critical - going low) Critical 131458 Under-Voltage Problem Cleared Information 131335 Over-Voltage Warning (Upper Non Critical - going high) Warning 131463 Over-Voltage Warning Clear
TrapID Description Severity 2715393 Battery Failure Critical 2715521 Battery Failure Cleared Information 487169 CPU Thermal Trip (Over Temperature Shutdown) Critical 487297 CPU Thermal Trip (Over Temperature Shutdown) Cleared Information 487168 CPU Internal Error Critical 487296 CPU Internal Error Cleared Information 487173 CPU Configuration Error Critical 487301 CPU Configuration Error Cleared Information 487175 CPU Presence (Processor Presence detected) Information 487303 CPU N
TrapID Description Severity 552707 Power Supply AC Lost Critical 552835 Power Supply AC Restored Information 789249 Memory Redundancy has been Lost Critical 789248 Memory redundancy has returned to Normal Information 1076994 System Event Log (SEL) Cleared Information 1076996 System Event Log (SEL) Full (Logging Disabled) Critical 2322176 ASR (Automatic System Recovery) Timer Expired Critical 2322177 ASR (Automatic System Recovery) Reset Occurred Critical 2322178 ASR (Automatic Sy
Storage Management Alert Reference 7 Storage Management’s alert or event management features let you monitor the health of storage resources such as controllers, connectors, array disks, and virtual disks. Alert Monitoring and Logging The Storage Management Service performs alert monitoring and logging. By default, the Storage Management Service starts when the managed system starts up. If you stop the Disk Management Service, then alert monitoring and logging stops.
Table 2010. Storage Management Alert Severity Alert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for informational purposes and does not indicate an error condition. For example, the alert may indicate the normal start or stop of an operation. Warning/Non-critical A component requires attention. This alert indicates a potential problem, but does not necessarily mean that the system has currently lost data or is nonfunctional.
NOTE: Storage Management supports trap forwarding on both 32-bit and 64-bit operating systems. Trap Variables The Storage Management SNMP traps use a set of variables that are included with every trap. Below mentioned variables are the Traditional Varbinds: Table 2011. Message ID Event Name messageIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.1 Description Storage Management alert (event) message number. Syntax INTEGER Access Read-only Table 2012.
Table 2015. Object OID Event Name objectOIDEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.5 Description MIB OID of the object causing the alert. Syntax DisplayString Access Read-only Table 2016. Object Nexus Event Name objectNexusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.6 Description Durable, unique ID of the object causing the alert. Syntax DisplayString Access Read-only Table 2017. Current Status Event Name currentStatusEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.
Access Read-only Table 2020. Enhanced System FQDN Event Name systemFQDNEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.10 Description Hostname of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 2021. Enhanced Service Tag Event Name serviceTagEvent Object ID 1.3.6.1.4.1.674.10893.1.20.200.11 Description Service Tag of object causing the alert if applicable. Syntax DisplayString Access Read-only Table 2022.
storage management messages, see the Dell OpenManage Server Administrator Messages Reference Guide available on the Dell Support website at dell.com/support/manuals.
iDRAC7 MIB 8 The Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRACSMIv2.mib) is the MIB supported by the Integrated Dell Remote Access Controller 7 (iDRAC7). This MIB provides management data that allows you to monitor devices and software on a system via an out-ofband connection to the iDRAC7 of a system. NOTE: iDRAC7 firmware release r1.30.30 or later, the iDRAC7 MIB file is published in both types of SMI (Structure of Managed Information) notations: SMIv1 and SMIv2.
SNMP Operations Supported SNMP version GET, GETNEXT, GETBULK SNMP v1, v2c and v3 TRAP SNMP v1 and SNMP v2c NOTE: iDRAC7 does not support the SNMP SET operation for any data NOTE: iDRAC7 firmware release r1.30.30 or later supports SNMP query operations (GET, GETNEXT, GETBULK) via the SNMPv3 protocol. In addition to supporting query operations via the SNMP v1 and SNMP v2c protocols, SNMP User Security Model (USM) is supported. iDRAC7 SNMP Data Security Features iDRAC7 firmware release r1.30.
Description This attribute defines the product name of a remote access card. Syntax StringType Access Read-only Table 2024. RAC Name Name racShortName Object ID 1.3.6.1.4.1.674.10892.5.1.1.2.0 Description This attribute defines the short product name of a remote access card. Syntax StringType Access Read-only Table 2025. RAC Description Name racDescription Object ID 1.3.6.1.4.1.674.10892.5.1.1.3.0 Description This attribute defines the product description of a remote access card.
Access Read-only Table 2029. RAC Type Name racType Object ID 1.3.6.1.4.1.674.10892.5.1.1.7.0 Description This attribute defines the type of a remote access card. Syntax RacTypeEnum Access Read-only Table 2030. RAC Firmware Version Name racFirmwareVersion Object ID 1.3.6.1.4.1.674.10892.5.1.1.8.0 Description This attribute defines the firmware version of a remote access card.
Table 2033. System Service Tag Name systemServiceTag Object ID 1.3.6.1.4.1.674.10892.5.1.3.2.0 Description This attribute defines the service tag of the system. Syntax StringType Access Read-only Table 2034. System Express Service Code Name systemExpressServiceCode Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0 Description This attribute defines the express service code of the system. Syntax StringType Access Read-only Table 2035. System Asset Tag Name systemAssetTag Object ID 1.3.6.1.
Description This attribute defines the form factor of the system. Syntax SystemFormFactorEnum Access Read-only Table 2039. System Data Center Name Name systemDataCenterName Object ID 1.3.6.1.4.1.674.10892.5.1.3.8.0 Description This attribute defines the Data Center locator of the system. Syntax StringType Access Read-only Table 2040. System Aisle Name Name systemAisleName Object ID 1.3.6.1.4.1.674.10892.5.1.3.9.0 Description This attribute defines the Aisle locator of the system.
Table 2044. System System ID Name systemSystemID Object ID 1.3.6.1.4.1.674.10892.5.1.3.13.0 Description This attribute defines the system ID of the system. Syntax Unsigned16BitRange Access Read-only Table 2045. System OS Version Name systemOSVersion Object ID 1.3.6.1.4.1.674.10892.5.1.3.14.0 Description This attribute defines the version of the operating system that the host is running. Syntax StringType Access Read-only Table 2046. System Room Name Name systemRoomName Object ID 1.
Status Group The Status Group objects provide status information about the system and storage. Table 2049. Global System Status Name globalSystemStatus Object ID 1.3.6.1.4.1.674.10892.5.2.1.0 Description This attribute defines the overall rollup status of all components in the system being monitored by the remote access card. Syntax ObjectStatusEnum Access Read-only Table 2050. System LCD Status Name systemLCDStatus Object ID 1.3.6.1.4.1.674.10892.5.2.2.
Storage Details Group The Storage Details Group contains tables that provide detailed information about the external storage subsystem of the system in which iDRAC7 resides. NOTE: See the iDRAC7 MIB file for details of the tables supported under the Storage Details Group. iDRAC7 Traps The iDRAC7 generates events that result in Simple Network Management Protocol (SNMP) traps and/or entries in the iDRAC7 Lifecycle Log. This section describes the traps, also known as alerts, generated by the iDRAC7.
Access Read-only Table 2054. Alert Message Variable Name alertMessage Object ID 1.3.6.1.4.1.674.10892.5.3.1.2.0 Description Message describing the alert. Syntax StringType Table 2055. Alert Current Status Variable Name alertCurrentStatus Object ID 1.3.6.1.4.1.674.10892.5.3.1.3.0 Description Current status of object causing the alert, if applicable. Syntax ObjectStatusEnum Access Read-only Table 2056. Alert System Service Tag Variable Name alertSystemServiceTag Object ID 1.3.6.1.4.
Table 2060. Alert Message Arguments Variable Name alertMessageArguments Object ID 1.3.6.1.4.1.674.10892.5.3.1.8.0 Description Concatenated set of strings representing the message arguments of the event. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string are preprocessed and changed to single quotes. Syntax StringType Table 2061.
Table 2064. Battery Traps TrapID Description Category SubCategory Severity Battery state has returned to System Health normal; or battery presence had been detected. Battery Event Information al Battery is low. System Health Battery Event Minor Battery has failed or battery is absent.
TrapID Description Category SubCategory Severity 2153 Fan failure. System Health Fan Event Critical Description Category SubCategory Severity Fiber Channel information. System Health Fiber Channel Information al Fiber Channel warning. System Health Fiber Channel Minor Fiber Channel failure or critical event.
Table 2071. NIC Traps TrapID Description Category SubCategory Severity Network information. System Health NIC Config Information al Network warning. System Health NIC Config Minor Network failure or critical event. System Health NIC Config Critical Description Category SubCategory Severity An OS graceful stop occurred; or an OS graceful shut-down occurred.
TrapID Description Category SubCategory Severity Physical disk warning. System Health Physical Disk Minor Physical disk failure. System Health Physical Disk Critical Description Category SubCategory Severity System BIOS detected a failure. System Health BIOS POST Critical Description Category SubCategory Severity Power supply has returned to normal. System Health Power Supply Information al Power supply has detected a System Health warning.
TrapID Description Category SubCategory Severity 2273 The system halted because system power exceeds capacity; or the system performance degraded because power draw exceeds the power threshold. System Health Power Usage Critical Description Category SubCategory Severity Redundancy information. System Health Redundancy Information al Redundancy is degraded. System Health Redundancy Minor Redundancy is lost.
Table 2082. Integrated Dual SD Module Redundancy Traps TrapID Description Category SubCategory Severity System Health IDSDM Redundancy Information al System Health IDSDM Redundancy Minor System Health IDSDM Redundancy Critical Description Category SubCategory Severity Security information. System Health Security Event Information al Security failure or critical event.
TrapID Description Category SubCategory Severity 2162 Temperature sensor has detected a warning value.
Table 2089. Voltage Probe Traps TrapID Description Category SubCategory Severity Voltage sensor reading is within range. System Health Voltage Information al Voltage sensor has detected System Health a warning value. Voltage Minor Voltage sensor has detected System Health a failure value.
Table 2092. Enclosure Traps TrapID Description Category SubCategory Severity Storage Storage Enclosr Information al Storage Storage Enclosr Minor Enclosure failure. Storage Storage Enclosr Critical Description Category SubCategory Severity Fan information. Storage Fan Event Information al Fan warning. Storage Fan Event Minor Fan failure.
TrapID Description Category SubCategory Severity 4233 Power supply failure. Storage Power Supply Critical Category SubCategory Severity Storage Information al Storage Minor Storage Critical Category SubCategory Severity Storage Temperature Information al Storage Temperature Minor Storage Temperature Critical Category SubCategory Severity Storage Virtual Disk Information al Storage Virtual Disk Minor Storage Virtual Disk Critical Table 2096.
Updates Trap Group The Updates Trap Group contains traps that fall under the Updates event category of iDRAC7. Updates traps are traps generated in response to events related to firmware/driver upgrades/downgrades. NOTE: Currently there are no Update traps. Audit Trap Group The Audit Trap Group contains traps that fall under the Audit event category of iDRAC7.
Configuration Trap Group The Configuration Trap Group contains traps that fall under the Configuration event category of the iDRAC7. Configuration traps are traps generated in response to events related to hardware configuration changes and software configuration changes. TrapID Description Category SubCategory The iDRAC generated a test trap event in response to a user request.
Standard Data Type Definitions 9 This appendix contains definitions for data types that are standard in most contexts across the information technology industry. These are the most common data types for describing variable values defined in the 10892.mib , dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific variable values are defined in the last section of the section in which they are introduced.
unknownCapabilities(1) The object’s capabilities are unknown. enableCapable(2) The object can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value). notReadyCapable(4) The object is not ready. enableAndNotReadyCapable (6) Enable and not ready capable. Table 2105. Dell State Settings Variable Name: DellStateSettings Data Type: Integer Possible Data Values Meaning of Data Value if set to zero(0) The object has no settings capabilities and its state is disabled.
ok(3) The object’s status is OK. nonCritical(4) The object’s status is warning, noncritical. critical(5) The object’s status is critical (failure). nonRecoverable(6) The object’s status is nonrecoverable (dead). Table 2108. Dell Status Redundancy Variable Name: DellStatusRedundancy Data Type: Integer Possible Data Values Meaning of Data Value other(1) The object’s status is not one of the following: unknown(2) The object’s redundancy status is unknown. full(3) The object is fully redundant.
the hex address 0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ... Byte 1 Byte 2 Byte 3 Byte 4. Full Dates Variable Name: DellDateName Data Type: DisplayString DisplayString (SIZE (25)) Full dates are defined in the ASCII format: yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuufff where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm are the minutes, and ss are the seconds.
SNMP Sample Output 10 This appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the Instrumentation management information base (MIB) sample output from the Simple Network Management Protocol (SNMP) covers the first four groups of the Instrumentation management information base (MIB).
1.3.6.1.4.1.674.10892.1.200.10.1.23.1 = '\02\02\02\02\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.25.1 = '\03\03\03\03\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.26.1 = '\02\02\02\02' 1.3.6.1.4.1.674.10892.1.200.10.1.27.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.28.1 = '\03\03\03\03' 1.3.6.1.4.1.674.10892.1.200.10.1.29.1 = '\02' 1.3.6.1.4.1.674.10892.1.200.10.1.30.1 = 3 1.3.6.1.4.1.674.10892.1.200.10.1.31.1 = '\03' 1.3.6.1.4.1.674.10892.1.200.10.1.41.1 = 3 1.3.6.1.4.1.674.
1.3.6.1.4.1.674.10892.1.300.40.1.1.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.4.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.5.1.1 cleared' 1.3.6.1.4.1.674.10892.1.300.40.1.6.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.7.1.1 1.3.6.1.4.1.674.10892.1.300.40.1.8.1.1 '20050513100047.